PTPeter Tomasulo

Peter Tomasulo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Tomasulo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • H. Kamel

    Blood Systems, Inc., Scottsdale, AZ, USA

    3 shared publications
  • M. Bravo

    Blood Systems, Inc., Scottsdale, AZ, USA

    3 shared publications
  • B. Custer

    Blood Systems, Inc., Scottsdale, AZ, USA

    2 shared publications
  • Hany Kamel

    From Blood Systems, Inc., Scottsdale, Arizona; Blood Systems Research Institute, San Francisco, California; the University of Washington, Seattle, Washington; and the University of California, San Francisco, California

    2 shared publications
  • Brian Custer

    From Blood Systems, Inc., Scottsdale, Arizona; Blood Systems Research Institute, San Francisco, California; the University of Washington, Seattle, Washington; and the University of California, San Francisco, California

    1 shared publication
  • G. F. Giordano

    United Blood Services, Scottsdale, AZ, USA

    1 shared publication

Latest Publications

  • Predicting improvement in detection of bacteria in apheresis platelets by maintaining constant component sampling proportion

    by Peter A. Tomasulo, Stephen J. Wagner

    In spite of interventions, approximately 1000 per 1,000,000 platelet (PLT) collections are contaminated with bacteria at collection. The current prestorage culture procedure at some blood centers is to inoculate a fixed volume from the collection bag (4-8 mL) regardless of collection volume. The sensitivity of early testing varies with the percent of collection volume sampled. We applied the Poisson model to determine whether sampling larger volumes might increase detection at pertinent contamination levels. The intervention was testing a fixed proportion of the collection volume from single, double, and triple collections. The Poisson model was applied to blood center data to calculate weighted average detection. Model 1 consisted of inoculating 3.2% of the collection volume from single, 1.6% from double, and 1.2% from triple PLT procedures (8 mL in each case). Model 2 consisted of inoculating 3.8% of the collection volume from all PLT procedures. Volume-related and non-volume-related contamination mechanisms were evaluated. Testing constant proportions of the collection volume (Model 2) increases percent detection over testing constant volumes (Model 1) (68% vs. 41% detection if contamination is 30 colony-forming units (CFUs)/collection bag and 17% vs. 9% detection if contamination is 5 CFUs/collection bag). At low levels of contamination (approx. 5 CFUs/bag), the intervention might double the number of contaminated units detected. Based on the application of the Poisson model to detection of bacteria in PLT concentrates, inoculating cultures with slightly consistent proportions of the collection volume should lead to a reduction in false negative tests and in the number of contaminated units transfused.


  • The reintroduction of nonleukoreduced blood: would patients and clinicians agree?

    by Lizabeth Rosenbaum, Peter Tomasulo, Karen Shoos Lipton, Paul Ness


  • Factors associated with fainting – before, during and after whole blood donation

    by M. Bravo, H. Kamel, B. Custer, P. Tomasulo

    Background  Whole blood (WB) donation encompasses several periods during which some donors faint. Identification of factors associated with fainting during each period should guide intervention strategies. Reducing faint reactions may reduce donor injuries and disability.Methods  Blood donation was divided into three periods: Period 1 – registration; Period 2 – phlebotomy; and Period 3 – post‐phlebotomy. Period 3 consists of two sub‐periods (3A – on‐site and 3B – off‐site). For each Period, stratified rates of fainting in relation to various donor and donation characteristics were calculated and multivariable logistic regression analyses to identify factors associated with fainting were conducted. Donor injuries in each period were also analysed.Results  Of the 956 766 donors registered in 2007, 554 534 (58%) donated WB. There were 43 fainting episodes and two injuries in Period 1 and 1520 faints and 73 injuries in Periods 2 and 3. Regression analyses showed that youth and donor first‐time status are associated with fainting in all periods; but most significantly in Period 1. Small estimated blood volume is notably not a factor in Period 1 but is significant in Periods 2 and 3. The highest injury rate is seen in Period 3A (0·07 and 0·09/1000 donations) for male and female donors, respectively.Conclusions  Variability in factors associated with fainting across defined periods of the donation process suggest differing underlying mechanisms and the possibility that interventions for the reactions most associated with injury during each time period can be designed. The highest rate of injury per donation occurred in ambulating donors.


  • Interventions to reduce the vasovagal reaction rate in young whole blood donors

    by Peter Tomasulo, Hany Kamel, Marjorie Bravo, Robert C. James, Brian Custer

    BACKGROUND: There have been multiple reports concerning the predictors of fainting reactions in blood donors, but few attempts to reduce the rates of fainting reactions with concomitant rigorous attempts to monitor the success of the interventions.STUDY DESIGN AND METHODS: We used a retrospective observational cohort study design, comparing the likelihood of reaction from 213,031 allogeneic whole blood donations made by 17‐ to 22‐year‐old donors in two separate 12‐month periods before and after the implementation of interventions to reduce reactions. The interventions were 1) a limit on the maximum percentage of estimated blood volume young donors could donate, 2) encouraging applied muscle tension during donation, and 3) providing approximately 500 mL of water before donation. Reactions were defined by severity and time in relation to the end of phlebotomy and documented according to standard procedures. Data analysis included comparison of stratified reaction rates and multivariable logistic regression analysis.RESULTS: The interventions decreased the aggregate reaction rates in male and female donors by 24% (p < 0.0001). There was a 25% decrease in delayed reactions (p = 0.0006) and a 38% decrease in off‐site reactions (p = 0.001) in female donors. The impact of the three interventions together on reaction rate was greater than the combined impact of exercises and water provision. Multivariable modeling showed that the interventions reduced reactions but did not prevent their occurrence in identified higher risk groups.CONCLUSION: The interventions to reduce vasovagal reactions in whole blood donors were effective. Future efforts to reduce reactions in blood donors can build on the strengths and avoid the weaknesses identified while conducting and analyzing the data from this study.


  • Open Access

    Time course of vasovagal syncope with whole blood donation

    by P. Tomasulo, M. Bravo, H. Kamel

    Background  Improving the safety of the donation experience will reduce donor injuries and increase donations, donation frequency and donor satisfaction. Understanding the physiology of donor reactions supports selection of effective interventions to reduce risk.Aims  The examination of the time course of donor vasovagal syncopal reactions (VVS) to determine when most reactions occur supports the development of appropriate theories about cause of the majority of the reactions and the application of interventions to reduce the risk of a significant number of reactions.Materials and Methods  A database of more than 900 000 donor registrations and more than 500 000 whole blood donation events was examined for the time course of VVS reactions by reviewing the onset time of the reactions. The donor experience was divided into three periods based on the theory that the risk of reaction depends on different factors in each of the periods. The time course was analyzed using frequency distribution counts stratified by donation status and separately by gender.Results  There were 956 766 registrations, 554 513 attempted whole blood donations, 536 907 complete donations and 17 606 incomplete donations. The mean draw time of a complete donation was 8.21 (95% CI, 8.2–8.21) min and for an incomplete donation was 8.91 (95% CI, 8.8–9.01) min. The reaction rate for Period 1 (before venipuncture) was 0.045/1000 registrations; for Period 2 (venipuncture to 4 min post‐venipuncture) and Period 3 (4 min post venipuncture to last reported VVS reaction ‐265 min), the reaction rate was 3.5/1000 for women and 1.5/1000 for men. There was a steady increase in the reaction rate during phlebotomy and the rate peaked at the time of needle removal. After needle removal there were peaks in the VVS rate at 5 and 9 min. The reaction rate declined steadily thereafter.Discussion  The peak reaction rates occur within a time period of 10 min beginning 1 min before needle removal. The reactions which have the most significant risk of donor injury occur later than this and often occur after the donor leaves the donation site. Approximately 10% of VVS reactions in male donors and 25% of VVS reactions in female donors occur more than 15 min after the needle is removed. The latest VVS reaction was reported to have begun at about 4.5 h after needle withdrawal.Conclusion  It is our thought that preventive interventions for reactions which occur during phlebotomy might be slightly different from the preventive measure aimed at reducing risk to donors after assuming upright posture. Once the donor stands up, relative hypovolemia plays a greater role and interventions should be aimed at preventing changes in blood pressure due to hypovolemia during this period.


  • A healthy donor or unsuspecting patient

    by Hany Kamel, Peter Tomasulo


  • Open Access

    Faint and pre‐faint reactions in whole blood donors: predictive value of pre‐donation measurements

    by P. Tomasulo, B. Custer, T. B. Wiltbank, M. Bravo, G. F. Giordano, H. Kamel