Leonard M. Hanssen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Leonard M. Hanssen has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Sergey N. Mekhontsev
Optical Technology Division, National Institute of Standards and Technology, Gaithersburg, USA
3 shared publicationsAlexander V. Prokhorov
Optical Technology Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publicationsB Wilthan
National Institute of Standards and Technology, Applied Chemicals and Materials Division, 325 Broadway, MS 647.01, Boulder, CO 80305 USA, USA
2 shared publicationsJ. Zeng
Utah State Univ. (United States)
2 shared publicationsVladimir B. Khromchenko
Optical Technology Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publicationsA. V. Prokhorov
Space Dynamics Laboratory
1 shared publication
Latest Publications
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03001
Infrared spectral normal emittance/emissivity comparison
The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03001
Infrared spectral normal emittance/emissivity comparison
The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 5 June 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8706
Evaluation of dome-input geometry for pyroelectric detectors
Dome-input pyroelectric radiometers with different black coatings were developed to extend the spectral responsivity scale from near infrared (NIR) to 20 μm. The reflective dome with shiny gold-coating has been known to be an efficient light trap to enhance the detector absorptance and to minimize spectral responsivity variation. The enhancement of spectral responsivity using reflective dome relies on optical characterization of black coating on detector, reflectance of dome reflector, and input aperture dimension, etc. We report a comparison of spectral responsivity of dome-input pyroelectric radiometers measured with/without dome-trap from 2.4 μm to 14 μm using the Infrared Spectral Comparator Facility (IRSCF) at NIST. The results show 4 % to 8 % gain of responsivity for two dome-input pyroelectric detectors, with reduced structure of spectral responsivity. The uncertainty of dome-input pyroelectric radiometer calibrations is approximately 2 % (k = 2).
- 5 June 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8706
Evaluation of dome-input geometry for pyroelectric detectors
Dome-input pyroelectric radiometers with different black coatings were developed to extend the spectral responsivity scale from near infrared (NIR) to 20 μm. The reflective dome with shiny gold-coating has been known to be an efficient light trap to enhance the detector absorptance and to minimize spectral responsivity variation. The enhancement of spectral responsivity using reflective dome relies on optical characterization of black coating on detector, reflectance of dome reflector, and input aperture dimension, etc. We report a comparison of spectral responsivity of dome-input pyroelectric radiometers measured with/without dome-trap from 2.4 μm to 14 μm using the Infrared Spectral Comparator Facility (IRSCF) at NIST. The results show 4 % to 8 % gain of responsivity for two dome-input pyroelectric detectors, with reduced structure of spectral responsivity. The uncertainty of dome-input pyroelectric radiometer calibrations is approximately 2 % (k = 2).
- 2 October 2011
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 32 (11-12) , 2623-2632
A Determination Study of the Cavity Emissivity of the Eutectic Fixed Points Co–C, Pt–C, and Re–C
- 2 October 2011
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 32 (11-12) , 2623-2632
A Determination Study of the Cavity Emissivity of the Eutectic Fixed Points Co–C, Pt–C, and Re–C
- 2 June 2009
- Published by IOP Publishing in Metrologia
- Vol. 46 (4) , S155-S159
Extension of the NIST spectral responsivity scale to the infrared using improved-NEP pyroelectric detectors
- 2 June 2009
- Published by IOP Publishing in Metrologia
- Vol. 46 (4) , S155-S159
Extension of the NIST spectral responsivity scale to the infrared using improved-NEP pyroelectric detectors
- 19 September 2008
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (10) , 1972-1978
Validation of the Infrared Emittance Characterization of Materials Through Intercomparison of Direct and Indirect Methods
- 19 September 2008
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (10) , 1972-1978
Validation of the Infrared Emittance Characterization of Materials Through Intercomparison of Direct and Indirect Methods
- 5 December 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 29 (1) , 352-369
Evaluation of Blackbody Cavity Emissivity in the Infrared Using Total Integrated Scatter Measurements
- 5 December 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 29 (1) , 352-369
Evaluation of Blackbody Cavity Emissivity in the Infrared Using Total Integrated Scatter Measurements
- 16 October 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (6) , 2128-2144
Radiative Properties of Blackbody Calibration Sources:Recent Advances in Computer Modeling
- 16 October 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (6) , 2128-2144
Radiative Properties of Blackbody Calibration Sources:Recent Advances in Computer Modeling
- 30 May 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (2) , 566-580
Use of a High-Temperature Integrating Sphere Reflectometer for Surface-Temperature Measurements
- 30 May 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (2) , 566-580
Use of a High-Temperature Integrating Sphere Reflectometer for Surface-Temperature Measurements
- 1 July 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (19) , 3196-3204
Integrating-sphere system and method for absolute measurement of transmittance, reflectance, and absorptance of specular samples
An integrating-sphere system has been designed and constructed for multiple optical properties measurement in the IR spectral range. In particular, for specular samples, the absolute transmittance and reflectance can be measured directly with high accuracy and the absorptance can be obtained from these by simple calculation. These properties are measured with a Fourier transform spectrophotometer for several samples of both opaque and transmitting materials. The expanded uncertainties of the measurements are shown to be less than 0.003 (absolute) over most of the detector-limited working spectral range of 2 to 18 µm. The sphere is manipulated by means of two rotation stages that enable the ports on the sphere to be rearranged in any orientation relative to the input beam. Although the sphere system is used for infrared spectral measurements, the measurement method, design principles, and features are generally applicable to other wavelengths as well.
- 1 July 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (19) , 3196-3204
Integrating-sphere system and method for absolute measurement of transmittance, reflectance, and absorptance of specular samples
An integrating-sphere system has been designed and constructed for multiple optical properties measurement in the IR spectral range. In particular, for specular samples, the absolute transmittance and reflectance can be measured directly with high accuracy and the absorptance can be obtained from these by simple calculation. These properties are measured with a Fourier transform spectrophotometer for several samples of both opaque and transmitting materials. The expanded uncertainties of the measurements are shown to be less than 0.003 (absolute) over most of the detector-limited working spectral range of 2 to 18 µm. The sphere is manipulated by means of two rotation stages that enable the ports on the sphere to be rearranged in any orientation relative to the input beam. Although the sphere system is used for infrared spectral measurements, the measurement method, design principles, and features are generally applicable to other wavelengths as well.