Takashi Ida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takashi Ida has a total of 283 co-authors. Here are the top co-authors by number of shared publications:
Daiki Hattan
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
4 shared publicationsShoki Ono
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
4 shared publications- Hideto Yamada
NGK SPARK PLUG CO., LTD. 1 , 2808 Iwasaki, Komaki, Aichi 485-8510, Japan
3 shared publications Katsuhiro Nomura
Inorganic Functional Materials Research Institute, National Institute of Advanced Industrial Science and Technology, Anagahora, Shimoshidami, Moriyama, Nagoya, Aichi 463-8560, Japan
3 shared publicationsTakehiro Yoshida
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
3 shared publicationsYoshinobu Takatsu
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
3 shared publications
Latest Publications
- Open Access
- 10 March 2025
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 40 (2) , 105-113
Deconvolutional treatment about sample transparency aberration interfered by opaque and translucent sample holders in Bragg–Brentano geometry
Sample transparency aberration in Bragg–Brentano geometry affected by interference with opaque and translucent sample holders has been formulated. The formulation for an opaque sample holder should be classified to 5 cases, depending on the apparent diffraction angle, beam width, specimen width, and specimen thickness. The cumulants of the aberration function for a translucent sample holder with an arbitrary linear attenuation coefficient can numerically be evaluated by a Gauss–Legendre quadrature. The use of a function defined by the convolution of truncated exponential and rectangular functions has been tested as the model for the aberration function. A double deconvolutional treatment (DCT) designed to cancel the effects of the first and third order cumulants of the aberration function has been applied to the XRD data of Si standard powder, NIST SRM640d. The diffraction peak profile in the data treated by the DCT method certainly shows improved symmetry. The main features of the symmetrized peak profile in the DCT data have been simulated by instrumental and specimen parameters. It is suggested that the current analytical method could be utilized for texture analysis, if the manufacturer of an XRD instrument should supply a more accurate information about the instrument.
- 10 March 2025
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 40 (2) , 105-113
Open AccessDeconvolutional treatment about sample transparency aberration interfered by opaque and translucent sample holders in Bragg–Brentano geometry
Sample transparency aberration in Bragg–Brentano geometry affected by interference with opaque and translucent sample holders has been formulated. The formulation for an opaque sample holder should be classified to 5 cases, depending on the apparent diffraction angle, beam width, specimen width, and specimen thickness. The cumulants of the aberration function for a translucent sample holder with an arbitrary linear attenuation coefficient can numerically be evaluated by a Gauss–Legendre quadrature. The use of a function defined by the convolution of truncated exponential and rectangular functions has been tested as the model for the aberration function. A double deconvolutional treatment (DCT) designed to cancel the effects of the first and third order cumulants of the aberration function has been applied to the XRD data of Si standard powder, NIST SRM640d. The diffraction peak profile in the data treated by the DCT method certainly shows improved symmetry. The main features of the symmetrized peak profile in the DCT data have been simulated by instrumental and specimen parameters. It is suggested that the current analytical method could be utilized for texture analysis, if the manufacturer of an XRD instrument should supply a more accurate information about the instrument.
- 5 June 2023
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 38 (2) , 81-89
Powder X-ray diffraction intensities of corundum calculated by conventional and density functional theory methods and extracted by deconvolutional treatment on experimental data
Least-squares analysis on the diffraction intensity values certified for NIST SRM676a and SRM1976c α -Al 2 O 3 (corundum) have shown that the intensities of SRM1976c can be simulated by the March-Dollase preferred orientation model along the (001)-direction. Diffraction intensities of randomly oriented corundum crystallites have been calculated from electron density data obtained by conventional and density functional theory (DFT) calculations, on the assumption of independent and similar atomic displacements for Al and O atoms. The results of DFT calculations support that the strongest peak of randomly oriented α -Al 2 O 3 crystalline powder should be 113-reflection, though the intensities simulated by DFT calculations are not closer to NIST SRM676a intensities than those expected for a fully ionized model ${\rm Al}_2^{3 + } {\rm O}_3^{2-}$ . Diffraction data of two types of relatively fine (nominally 2–3 μm and ca 0.3 μm) α -Al 2 O 3 powder have been collected and processed by a deconvolutional treatment (DCT). Integrated peak intensities extracted from the DCT data by an individual peak profile fitting method also support that the 113-reflection is the strongest reflection of randomly oriented α -Al 2 O 3 crystalline powder.- 5 June 2023
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 38 (2) , 81-89
Powder X-ray diffraction intensities of corundum calculated by conventional and density functional theory methods and extracted by deconvolutional treatment on experimental data
Least-squares analysis on the diffraction intensity values certified for NIST SRM676a and SRM1976c α -Al 2 O 3 (corundum) have shown that the intensities of SRM1976c can be simulated by the March-Dollase preferred orientation model along the (001)-direction. Diffraction intensities of randomly oriented corundum crystallites have been calculated from electron density data obtained by conventional and density functional theory (DFT) calculations, on the assumption of independent and similar atomic displacements for Al and O atoms. The results of DFT calculations support that the strongest peak of randomly oriented α -Al 2 O 3 crystalline powder should be 113-reflection, though the intensities simulated by DFT calculations are not closer to NIST SRM676a intensities than those expected for a fully ionized model ${\rm Al}_2^{3 + } {\rm O}_3^{2-}$ . Diffraction data of two types of relatively fine (nominally 2–3 μm and ca 0.3 μm) α -Al 2 O 3 powder have been collected and processed by a deconvolutional treatment (DCT). Integrated peak intensities extracted from the DCT data by an individual peak profile fitting method also support that the 113-reflection is the strongest reflection of randomly oriented α -Al 2 O 3 crystalline powder.- 2 May 2022
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 37 (1) , 13-21
Convolution and deconvolutional treatment on sample transparency aberration in Bragg–Brentano geometry
Exact and approximate mathematical models for the effects of sample transparency on the powder diffraction intensity data are examined. Application of the formula based on the first-order approximation about the deviation angle is justified for realistic measurement and computing systems. The effects of sample transparency are expressed by double convolution formulas applying two different scale transforms, including three parameters, goniometer radius R , penetration depth μ −1 , and thickness of the sample t . The deconvolutional treatment automatically recovers the lost intensity and corrects the peak shift and asymmetric deformation of peak profile caused by the sample transparency.
- 2 May 2022
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 37 (1) , 13-21
Convolution and deconvolutional treatment on sample transparency aberration in Bragg–Brentano geometry
Exact and approximate mathematical models for the effects of sample transparency on the powder diffraction intensity data are examined. Application of the formula based on the first-order approximation about the deviation angle is justified for realistic measurement and computing systems. The effects of sample transparency are expressed by double convolution formulas applying two different scale transforms, including three parameters, goniometer radius R , penetration depth μ −1 , and thickness of the sample t . The deconvolutional treatment automatically recovers the lost intensity and corrects the peak shift and asymmetric deformation of peak profile caused by the sample transparency.
- Open Access
- 2 November 2021
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 36 (4) , 222-232
Continuous series of symmetric peak profile functions determined by standard deviation and kurtosis
A mathematical system for modeling the effects of symmetrized instrumental aberrations has been developed. The system is composed of the truncated Gaussian, sheared Gaussian, and Rosin-Rammler-type functions. The shape of the function can uniquely be determined by the standard deviation and kurtosis. A practical method to evaluate the convolution with the Lorentzian function and results of application to the analysis of experimental powder diffraction data are briefly described.
- 2 November 2021
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 36 (4) , 222-232
Open AccessContinuous series of symmetric peak profile functions determined by standard deviation and kurtosis
A mathematical system for modeling the effects of symmetrized instrumental aberrations has been developed. The system is composed of the truncated Gaussian, sheared Gaussian, and Rosin-Rammler-type functions. The shape of the function can uniquely be determined by the standard deviation and kurtosis. A practical method to evaluate the convolution with the Lorentzian function and results of application to the analysis of experimental powder diffraction data are briefly described.
- 7 September 2021
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 36 (3) , 169-175
Equatorial aberration for powder diffraction data collected by continuous-scan integration of a silicon strip X-ray detector
The application of continuous-scan integration to collect X-ray diffraction data with a Si strip X-ray detector (CSI-SSXD) introduces additional effects on the peak shift and deformation of peak shape caused by the equatorial aberration. A deconvolutional method to correct the effects of equatorial aberration in CSI-SSXD data is proposed in this study. There are four critical angles related to the effects of spillover of the incident X-ray beam from the specimen face in the CSI-SSXD data. Exact values of cumulants of the equatorial aberration function are efficiently evaluated by 4 × 4 point two-dimensional Gauss–Legendre integral. A naïve two-step deconvolutional method has been applied to remove the effects of the first and third-order cumulants of the equatorial aberration function from the observed CSI-SSXD data. The performance of the algorithm has been tested by analyses of CSI-SSXD data of three LaB 6 powder specimens with the widths of 20, 10, and 5 mm, collected with a diffractometer with the goniometer radius of 150 mm.
- 7 September 2021
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 36 (3) , 169-175
Equatorial aberration for powder diffraction data collected by continuous-scan integration of a silicon strip X-ray detector
The application of continuous-scan integration to collect X-ray diffraction data with a Si strip X-ray detector (CSI-SSXD) introduces additional effects on the peak shift and deformation of peak shape caused by the equatorial aberration. A deconvolutional method to correct the effects of equatorial aberration in CSI-SSXD data is proposed in this study. There are four critical angles related to the effects of spillover of the incident X-ray beam from the specimen face in the CSI-SSXD data. Exact values of cumulants of the equatorial aberration function are efficiently evaluated by 4 × 4 point two-dimensional Gauss–Legendre integral. A naïve two-step deconvolutional method has been applied to remove the effects of the first and third-order cumulants of the equatorial aberration function from the observed CSI-SSXD data. The performance of the algorithm has been tested by analyses of CSI-SSXD data of three LaB 6 powder specimens with the widths of 20, 10, and 5 mm, collected with a diffractometer with the goniometer radius of 150 mm.
- 15 July 2020
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 35 (3) , 166-177
Application of deconvolutional treatment to powder diffraction data collected with a Bragg-Brentano diffractometer with a contaminated Cu target and a Ni filter
A deconvolutional method for preprocessing powder diffraction data has been improved. The cumulants of instrumental aberration functions of Bragg-Brentano (Parrish) diffractometer calculated up to the fourth order are presented. The treatments of axial-divergence aberration and the effective spectroscopic profile of the source X-ray have been simplified from those used in previous methods. The current method has been applied to powder diffraction data collected with a Cu-target X-ray tube, used over 20 years, and a Ni-foil K β filter.
- 15 July 2020
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 35 (3) , 166-177
Application of deconvolutional treatment to powder diffraction data collected with a Bragg-Brentano diffractometer with a contaminated Cu target and a Ni filter
A deconvolutional method for preprocessing powder diffraction data has been improved. The cumulants of instrumental aberration functions of Bragg-Brentano (Parrish) diffractometer calculated up to the fourth order are presented. The treatments of axial-divergence aberration and the effective spectroscopic profile of the source X-ray have been simplified from those used in previous methods. The current method has been applied to powder diffraction data collected with a Cu-target X-ray tube, used over 20 years, and a Ni-foil K β filter.
- 5 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (3) , 679-685
Equatorial aberration of powder diffraction data collected with an Si strip X-ray detector by a continuous-scan integration method
Exact and approximate mathematical formulas of equatorial aberration for powder diffraction data collected with an Si strip X-ray detector in continuous-scan integration mode are presented. An approximate formula is applied to treat the experimental data measured with a commercial powder diffractometer.
- 5 May 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (3) , 679-685
Equatorial aberration of powder diffraction data collected with an Si strip X-ray detector by a continuous-scan integration method
Exact and approximate mathematical formulas of equatorial aberration for powder diffraction data collected with an Si strip X-ray detector in continuous-scan integration mode are presented. An approximate formula is applied to treat the experimental data measured with a commercial powder diffractometer.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 80-87
Deconvolution–convolution treatment on powder diffraction data collected with Cu Kα X-ray and Ni Kβ filter
A method to remove small Cu Kβ peaks and step structures caused by Ni K -edge absorption as well as Cu Kα 2 sub-peaks from powder diffraction intensity data measured with Cu-target X-ray source and Ni-foil filter is proposed. The method is based on deconvolution–convolution treatment applying scale transform of abscissa, Fourier transform, and a realistic spectroscopic model for the source X-ray. The validity of the method has been tested by analysis of the powder diffraction data of a standard LaB 6 powder (NIST SRM660a) sample, collected with the combination of Cu Kα X-ray source, Ni-foil Kβ filter, flat powder specimen and one-dimensional Si strip detector. The diffraction intensity data treated with the method have certainly shown background intensity profile without Cu Kβ peaks and Ni K -edge step structures.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 80-87
Deconvolution–convolution treatment on powder diffraction data collected with Cu Kα X-ray and Ni Kβ filter
A method to remove small Cu Kβ peaks and step structures caused by Ni K -edge absorption as well as Cu Kα 2 sub-peaks from powder diffraction intensity data measured with Cu-target X-ray source and Ni-foil filter is proposed. The method is based on deconvolution–convolution treatment applying scale transform of abscissa, Fourier transform, and a realistic spectroscopic model for the source X-ray. The validity of the method has been tested by analysis of the powder diffraction data of a standard LaB 6 powder (NIST SRM660a) sample, collected with the combination of Cu Kα X-ray source, Ni-foil Kβ filter, flat powder specimen and one-dimensional Si strip detector. The diffraction intensity data treated with the method have certainly shown background intensity profile without Cu Kβ peaks and Ni K -edge step structures.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 121-133
Improvement of deconvolution–convolution treatment of axial-divergence aberration in Bragg–Brentano geometry
An improved method to correct observed shift and asymmetric deformation of diffraction peak profile caused by the axial-divergence aberration in Bragg–Brentano geometry is proposed. The method is based on deconvolution–convolution treatment applying scale transform of abscissa, Fourier transform, and cumulant analysis of an analytical model for the axial-divergence aberration. The method has been applied to the powder diffraction data of a standard LaB 6 powder (NIST SRM660a) sample, collected with a one-dimensional Si strip detector. The locations, widths and shape of the peaks in the deconvolved–convolved powder diffraction data have been analyzed. The finally obtained whole powder diffraction pattern ranging from 10° to 145° in diffraction angle has been simulated by the Pawley method applying a symmetric Pearson VII peak profile model to each peak with ten background, two peak-shift, three line-width, and two peak-shape parameters, and the R p value of the best fit has been estimated at 4.4%.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 121-133
Improvement of deconvolution–convolution treatment of axial-divergence aberration in Bragg–Brentano geometry
An improved method to correct observed shift and asymmetric deformation of diffraction peak profile caused by the axial-divergence aberration in Bragg–Brentano geometry is proposed. The method is based on deconvolution–convolution treatment applying scale transform of abscissa, Fourier transform, and cumulant analysis of an analytical model for the axial-divergence aberration. The method has been applied to the powder diffraction data of a standard LaB 6 powder (NIST SRM660a) sample, collected with a one-dimensional Si strip detector. The locations, widths and shape of the peaks in the deconvolved–convolved powder diffraction data have been analyzed. The finally obtained whole powder diffraction pattern ranging from 10° to 145° in diffraction angle has been simulated by the Pawley method applying a symmetric Pearson VII peak profile model to each peak with ten background, two peak-shift, three line-width, and two peak-shape parameters, and the R p value of the best fit has been estimated at 4.4%.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 108-114
Removal of small parasite peaks in powder diffraction data by a multiple deconvolution method
Four series of small parasite peaks observed in powder diffraction data recorded with a Cu-target X-ray tube and a Ni filter on the diffracted beam side in Bragg–Brentano geometry are investigated. One series of the parasite peaks is assigned to the tungsten Lα -emission. Other three types of the parasite peak series are likely to be caused by the K -emissions of Ni, but the peak locations are deviated from those predicted by the Bragg's law. An empirical formula to locate the parasite peaks and a method to remove them from observed powder diffraction data are proposed. The method is based on the whole-pattern deconvolution–convolution treatment on the transformed scale of abscissa. The parameters optimized for the diffraction data measured for Si powder has been applied on treatment of the data of LaB 6 powder recorded under the same experimental conditions. It has been confirmed that the parasite peaks in the observed data can effectively be removed by the deconvolution treatment with parameters determined by a reference measurement.
- 29 June 2018
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 33 (2) , 108-114
Removal of small parasite peaks in powder diffraction data by a multiple deconvolution method
Four series of small parasite peaks observed in powder diffraction data recorded with a Cu-target X-ray tube and a Ni filter on the diffracted beam side in Bragg–Brentano geometry are investigated. One series of the parasite peaks is assigned to the tungsten Lα -emission. Other three types of the parasite peak series are likely to be caused by the K -emissions of Ni, but the peak locations are deviated from those predicted by the Bragg's law. An empirical formula to locate the parasite peaks and a method to remove them from observed powder diffraction data are proposed. The method is based on the whole-pattern deconvolution–convolution treatment on the transformed scale of abscissa. The parameters optimized for the diffraction data measured for Si powder has been applied on treatment of the data of LaB 6 powder recorded under the same experimental conditions. It has been confirmed that the parasite peaks in the observed data can effectively be removed by the deconvolution treatment with parameters determined by a reference measurement.