Sukunya Oaew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sukunya Oaew has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Pasara Vijitvarasan
Nakhonsawan Campus, Mahidol University, Nakhonsawan, 60130, Thailand
4 shared publications- Sarawut Cheunkar
Division of Biotechnology, School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkok 10150, Thailand
4 shared publications Sarawut Cheunkar
3 shared publicationsArunothai Rattanachata
Synchrotron Light Research Institute, Nakhon Ratchasima, 30000, Thailand
2 shared publications- Attasith Parnsubsakul
Sensor Research Unit (SRU) Department of Chemistry Faculty of Science Chulalongkorn University Bangkok 10330 Thailand
2 shared publications Nitsara Karoonuthaisiri
2 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by Elsevier in Food Chemistry: X
- Vol. 36
Alginate-PVA interpenetrating network nanogels: a pH-responsive carrier for thermal stabilization and sustained release of phycocyanin
- 20 May 2026
- Published by Elsevier in Food Chemistry: X
- Vol. 36
Open AccessAlginate-PVA interpenetrating network nanogels: a pH-responsive carrier for thermal stabilization and sustained release of phycocyanin
- 6 May 2026
- Published by Elsevier in Food Chemistry
- Vol. 518, 149531
Zein/β-cyclodextrin nanocarriers for dual delivery of resveratrol and piperine: a synergistic approach for enhanced nutraceutical stability and function
- 6 May 2026
- Published by Elsevier in Food Chemistry
- Vol. 518, 149531
Zein/β-cyclodextrin nanocarriers for dual delivery of resveratrol and piperine: a synergistic approach for enhanced nutraceutical stability and function
- Open Access
- 10 July 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (27) , 5795
Correction: Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor
Correction for ‘Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor’ by Yossawadee Sriondee et al. , Anal. Methods , 2024, 16 , 599–607, https://doi.org/10.1039/D3AY01842C.
- 10 July 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (27) , 5795
Open AccessCorrection: Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor
Correction for ‘Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor’ by Yossawadee Sriondee et al. , Anal. Methods , 2024, 16 , 599–607, https://doi.org/10.1039/D3AY01842C.
- 19 December 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (4) , 599-607
Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor
Glycated hemoglobin (HbA1c) has been an important biomarker for long-term diagnosis and monitoring of diabetes mellitus. The development of a rapid, reliable, and less sophisticated device to measure HbA1c is imperative to facilitate efficient early-care diabetes management. To date, no existing aptamer-based biosensor (aptasensor) for detecting HbA1c has been developed using a quartz crystal microbalance (QCM). In this study, the aptamer specific to HbA1c as a novel biosensing receptor was covalently functionalized onto a QCM substrate via mixed self-assembled monolayers (SAMs). A portable QCM equipped with a liquid-flow module was used to investigate the biospecificity, sensitivity, and interaction dynamics of the aptamer functionalized surfaces. The real-time kinetic analysis of HbA1c binding to the surface-functionalized aptamers revealed “on” and “off” binding rates of 4.19 × 104 M−1 s−1 and 2.43 × 10−3 s−1, respectively. These kinetic parameters imply that the QCM-based aptasensor specifically recognizes HbA1c with an equilibrium dissociation constant as low as 57.99 nM. The linear detection of HbA1c spanned from 13 to 108 nM, with a limit of detection (LOD) of 26.29 nM. Moreover, the spiked plasma sample analysis offered compelling evidence that this aptasensor is a promising technique for developing a point-of-care device for diabetes mellitus.
- 19 December 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (4) , 599-607
Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor
Glycated hemoglobin (HbA1c) has been an important biomarker for long-term diagnosis and monitoring of diabetes mellitus. The development of a rapid, reliable, and less sophisticated device to measure HbA1c is imperative to facilitate efficient early-care diabetes management. To date, no existing aptamer-based biosensor (aptasensor) for detecting HbA1c has been developed using a quartz crystal microbalance (QCM). In this study, the aptamer specific to HbA1c as a novel biosensing receptor was covalently functionalized onto a QCM substrate via mixed self-assembled monolayers (SAMs). A portable QCM equipped with a liquid-flow module was used to investigate the biospecificity, sensitivity, and interaction dynamics of the aptamer functionalized surfaces. The real-time kinetic analysis of HbA1c binding to the surface-functionalized aptamers revealed “on” and “off” binding rates of 4.19 × 104 M−1 s−1 and 2.43 × 10−3 s−1, respectively. These kinetic parameters imply that the QCM-based aptasensor specifically recognizes HbA1c with an equilibrium dissociation constant as low as 57.99 nM. The linear detection of HbA1c spanned from 13 to 108 nM, with a limit of detection (LOD) of 26.29 nM. Moreover, the spiked plasma sample analysis offered compelling evidence that this aptasensor is a promising technique for developing a point-of-care device for diabetes mellitus.
- 3 October 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (42) , 4193-4201
Reactive argon-plasma activation of screen-printed carbon electrodes for highly selective dopamine determination
A facile argon (Ar) plasma treatment was employed to enhance the electrocatalytic reactivity of screen-printed carbon electrodes for selective dopamine (DA) detection.
- 3 October 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (42) , 4193-4201
Reactive argon-plasma activation of screen-printed carbon electrodes for highly selective dopamine determination
A facile argon (Ar) plasma treatment was employed to enhance the electrocatalytic reactivity of screen-printed carbon electrodes for selective dopamine (DA) detection.
- 1 April 2022
- Published by Elsevier in Food Control
- Vol. 134
A point-of-use lateral flow aptasensor for naked-eye detection of aflatoxin B1
- 1 April 2022
- Published by Elsevier in Food Control
- Vol. 134
A point-of-use lateral flow aptasensor for naked-eye detection of aflatoxin B1
- 26 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (12) , 5466-5473
Zwitterionic peptide-capped gold nanoparticles for colorimetric detection of Ni 2+
Recyclable zwitterionic peptide-capped AuNPs for highly sensitive detection of Ni 2+ .
- 26 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (12) , 5466-5473
Zwitterionic peptide-capped gold nanoparticles for colorimetric detection of Ni 2+
Recyclable zwitterionic peptide-capped AuNPs for highly sensitive detection of Ni 2+ .
- 1 October 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 896, 152-159
Paper-based scanometric assay for lead ion detection using DNAzyme
- 1 October 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 896, 152-159
Paper-based scanometric assay for lead ion detection using DNAzyme
- 1 April 2012
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 34 (1) , 238-243
Gold nanoparticles/horseradish peroxidase encapsulated polyelectrolyte nanocapsule for signal amplification in Listeria monocytogenes detection
- 1 April 2012
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 34 (1) , 238-243
Gold nanoparticles/horseradish peroxidase encapsulated polyelectrolyte nanocapsule for signal amplification in Listeria monocytogenes detection