Michael A Thiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael A Thiel has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Claude Kaufmann
Augenklinik, Luzerner Kantonsspital, Luzern, Switzerland
3 shared publications - Frank Bochmann
Department of Ophthalmology, Cantonal Hospital of Lucerne, Lucerne, Switzerland
2 shared publications C Kaufmann
Department of Ophthalmology, University of Zurich, Switzerland
1 shared publicationC N Becht
1 shared publication- Christoph N Becht
Department of Ophthalmology, Lucerne Cantonal Hospital, Lucerne, Switzerland
1 shared publication D J Coster
Department of Ophthalmology, Flinders University of South Australia, Adelaide, Australia
1 shared publication
Latest Publications
- Open Access
- 17 January 2011
- Published by Springer Nature in BMC Ophthalmology
- Vol. 11 (1) , 1
ISRCTN12125882 - Influence of topical anti-VEGF (Ranibizumab) on the outcome of filtration surgery for glaucoma - Study Protocol
Excessive wound healing, with scarring of the episcleral tissue or encapsulation of the filtering bleb is the main reason for failure in trabeculectomy. Ranibizumab, an inhibitor of the Vascular Endothelial Growth Factor (VEGF), is seen as a promising candidate to prevent or treat extensive wound healing. We describe the design of a two phased study, i) assessing the local tolerability and safety of topical ranibizumab and ii) assessing the efficacy of topical ranibizumab against placebo in patients who underwent trabeculectomy with mitomycin C combined with phacoemulsification and intra ocular lens (IOL) implantation.
- 17 January 2011
- Published by Springer Nature in BMC Ophthalmology
- Vol. 11 (1) , 1
Open AccessISRCTN12125882 - Influence of topical anti-VEGF (Ranibizumab) on the outcome of filtration surgery for glaucoma - Study Protocol
Excessive wound healing, with scarring of the episcleral tissue or encapsulation of the filtering bleb is the main reason for failure in trabeculectomy. Ranibizumab, an inhibitor of the Vascular Endothelial Growth Factor (VEGF), is seen as a promising candidate to prevent or treat extensive wound healing. We describe the design of a two phased study, i) assessing the local tolerability and safety of topical ranibizumab and ii) assessing the efficacy of topical ranibizumab against placebo in patients who underwent trabeculectomy with mitomycin C combined with phacoemulsification and intra ocular lens (IOL) implantation.
- 1 December 2010
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 5 (6) , 743-749
Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
- 1 December 2010
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 5 (6) , 743-749
Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
- 21 April 2009
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 226 (04) , 230-233
Predictability of Microkeratome-Dependent Flap Thickness for DSAEK
Hintergrund: Die optimale Dicke der Spenderlamelle für die lamellierende Endotheltransplantation (DSAEK) liegt bei einer Lamellendicke von 120 – 180 µm. Zum Ausgleich der erheblichen Schwankungen der zentralen Hornhautdicke (CCT) der Spenderhornhäute gibt es verschiedene Keratome mit unterschiedlichen Schnitttiefen. Das Ziel dieser Studie war die Beurteilung der Vorhersagbarkeit der Schnitttiefe unterschiedlicher Keratome während klinischer Routineeingriffe. Methode: In einer prospektiven Studie wurden mit einem 50 MHz-Präzisionspachymeter die CCT der Spenderhornhaut nach der Epithelentfernung und die CCT nach dem lamellierenden Schnitt gemessen. Keratome mit Schnitttiefen von 300, 350 und 400 µ wurden verwendet. Die Schnitttiefe wurde berechnet durch Abzug der Lamellendicke von der ursprünglichen Hornhautdicke vor dem Schnitt. Resultate: Die mittlere (± ) Schnitttiefe lag bei 320 ± 45 µm für das Amadeus-350-Keratom, 317 ± 48 µm für das Moria-300er-Keratom, 388 ± 58 µm für das Moria-350er-Keratom und 467 ± 94 µm für das Moria-400er-Keratom. Weder die Dauer noch die Technik der Spenderaufbewahrung hatte einen Einfluss auf die Genauigkeit der Schnitttiefe. Schlussfolgerung: Die Voraussagbarkeit der mittleren Schnitttiefe der DSAEK-Keratome ist genauer als diejeniger der entsprechenden, oberflächlich schneidenden LASIK-Keratome. Dies hängt möglicherweise damit zusammen, dass das Epithel vor dem DSAEK-Schnitt entfernt wird. Trotz der höheren Voraussagbarkeit besteht eine erhebliche Streuung der Schnitttiefe bei den individuellen Schnitten. Background: The recommended thickness of the graft lamella in Descemet’s stripping automated endothelial keratoplasty (DSAEK) is 120 – 180 µm. To adjust for the large variation in central corneal thickness (CCT) of eye bank donor corneas, microkeratome plates of different heights are available. The aim of this study was to evaluate the lamella thickness predictability of different keratome plates in a clinical routine setting. Methods: In a prospective study of 60 consecutive DSAEK procedures, CCT was measured with a 50 MHz ultrasound pachymeter after meticulous epithelium removal immediately before and after lamella creation. Selected plate thickness was 300, 350, or 400 µ, respectively. Cutting depth was calculated by subtracting the remaining CCT of the deep lamella after the cut from the initial CCT before the cut. Results: The mean (± SD) cutting depth was 320 ± 45 µm with the Amadeus 350 keratome, 317 ± 48 µm with the Moria 300 keratome, 388 ± 58 µm with the Moria 350 keratome and 467 ± 94 µm with the Moria 400 keratome. Neither the duration nor the type of donor preservation had an effect on the accuracy of the cutting depth. Conclusion: The mean cutting depth for the DSAEK keratomes is more accurate than the cutting depth of the same keratome heads designed for LASIK. This might be due to the fact that DSAEK lamellas were cut after complete epithelial removal. Despite the accurate mean cutting accuracy, there is a substantial variation between individual cuts which have to be taken into consideration.
- 21 April 2009
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 226 (04) , 230-233
Predictability of Microkeratome-Dependent Flap Thickness for DSAEK
Hintergrund: Die optimale Dicke der Spenderlamelle für die lamellierende Endotheltransplantation (DSAEK) liegt bei einer Lamellendicke von 120 – 180 µm. Zum Ausgleich der erheblichen Schwankungen der zentralen Hornhautdicke (CCT) der Spenderhornhäute gibt es verschiedene Keratome mit unterschiedlichen Schnitttiefen. Das Ziel dieser Studie war die Beurteilung der Vorhersagbarkeit der Schnitttiefe unterschiedlicher Keratome während klinischer Routineeingriffe. Methode: In einer prospektiven Studie wurden mit einem 50 MHz-Präzisionspachymeter die CCT der Spenderhornhaut nach der Epithelentfernung und die CCT nach dem lamellierenden Schnitt gemessen. Keratome mit Schnitttiefen von 300, 350 und 400 µ wurden verwendet. Die Schnitttiefe wurde berechnet durch Abzug der Lamellendicke von der ursprünglichen Hornhautdicke vor dem Schnitt. Resultate: Die mittlere (± ) Schnitttiefe lag bei 320 ± 45 µm für das Amadeus-350-Keratom, 317 ± 48 µm für das Moria-300er-Keratom, 388 ± 58 µm für das Moria-350er-Keratom und 467 ± 94 µm für das Moria-400er-Keratom. Weder die Dauer noch die Technik der Spenderaufbewahrung hatte einen Einfluss auf die Genauigkeit der Schnitttiefe. Schlussfolgerung: Die Voraussagbarkeit der mittleren Schnitttiefe der DSAEK-Keratome ist genauer als diejeniger der entsprechenden, oberflächlich schneidenden LASIK-Keratome. Dies hängt möglicherweise damit zusammen, dass das Epithel vor dem DSAEK-Schnitt entfernt wird. Trotz der höheren Voraussagbarkeit besteht eine erhebliche Streuung der Schnitttiefe bei den individuellen Schnitten. Background: The recommended thickness of the graft lamella in Descemet’s stripping automated endothelial keratoplasty (DSAEK) is 120 – 180 µm. To adjust for the large variation in central corneal thickness (CCT) of eye bank donor corneas, microkeratome plates of different heights are available. The aim of this study was to evaluate the lamella thickness predictability of different keratome plates in a clinical routine setting. Methods: In a prospective study of 60 consecutive DSAEK procedures, CCT was measured with a 50 MHz ultrasound pachymeter after meticulous epithelium removal immediately before and after lamella creation. Selected plate thickness was 300, 350, or 400 µ, respectively. Cutting depth was calculated by subtracting the remaining CCT of the deep lamella after the cut from the initial CCT before the cut. Results: The mean (± SD) cutting depth was 320 ± 45 µm with the Amadeus 350 keratome, 317 ± 48 µm with the Moria 300 keratome, 388 ± 58 µm with the Moria 350 keratome and 467 ± 94 µm with the Moria 400 keratome. Neither the duration nor the type of donor preservation had an effect on the accuracy of the cutting depth. Conclusion: The mean cutting depth for the DSAEK keratomes is more accurate than the cutting depth of the same keratome heads designed for LASIK. This might be due to the fact that DSAEK lamellas were cut after complete epithelial removal. Despite the accurate mean cutting accuracy, there is a substantial variation between individual cuts which have to be taken into consideration.
- Open Access
- 9 January 2009
- Published by Springer Nature in Eye
- Vol. 23 (10) , 1962-1965
Antibody-based immunosuppressive agents for corneal transplantation
The progress in antibody engineering over the last 20 years has created the tools for the development of novel antibody-based drugs and constructs, such as small antibody fragments, suitable for topical administration. In rheumatology, oncology, transplantation medicine and ophthalmology, therapeutic antibody constructs, and antibody fragments have been responsible for the clinical progress seen over the last decade. Although antibody-based therapies have become a well-established immunosuppressive option in solid organ transplantation, there are only very few reports with regard to corneal transplantation. The following review explains some of the important aspects of engineered antibody-based therapeutic agents and summarises the current use of such immunosuppressive therapies in transplantation medicine and corneal transplantation.
- 9 January 2009
- Published by Springer Nature in Eye
- Vol. 23 (10) , 1962-1965
Open AccessAntibody-based immunosuppressive agents for corneal transplantation
The progress in antibody engineering over the last 20 years has created the tools for the development of novel antibody-based drugs and constructs, such as small antibody fragments, suitable for topical administration. In rheumatology, oncology, transplantation medicine and ophthalmology, therapeutic antibody constructs, and antibody fragments have been responsible for the clinical progress seen over the last decade. Although antibody-based therapies have become a well-established immunosuppressive option in solid organ transplantation, there are only very few reports with regard to corneal transplantation. The following review explains some of the important aspects of engineered antibody-based therapeutic agents and summarises the current use of such immunosuppressive therapies in transplantation medicine and corneal transplantation.