Harry E. Prince
Research Subjects
Harry E. Prince has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Wayne R. Hogrefe
Focus Technologies, Cypress, California 90630
2 shared publicationsMary Lape'-Nixon
Focus Technologies, Cypress, California 90630
1 shared publicationMary Lapé-Nixon
Focus Technologies, Cypress, California
1 shared publicationRonald J. Moore
Focus Technologies, Cypress, California 90630
1 shared publication
Latest Publications
- Open Access
- 1 January 2005
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 12 (1) , 231-233
Evaluation of a West Nile Virus Immunoglobulin A Capture Enzyme-Linked Immunosorbent Assay
An in-house-developed enzyme-linked immunosorbent assay detected West Nile virus (WNV) immunoglobulin A (IgA) in 65 of 68 sera from WNV-infected patients; 40 of 63 WNV IgM-positive, IgG-negative serum or plasma specimens; 65 of 67 WNV IgM-positive, IgG-positive specimens; 0 of 70 WNV IgM-negative, IgG-negative specimens; and 0 of 64 archived blood donation sera. WNV IgA is thus highly prevalent among WNV-infected patients and typically appears after WNV IgM but before WNV IgG.
- 1 January 2005
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 12 (1) , 231-233
Open AccessEvaluation of a West Nile Virus Immunoglobulin A Capture Enzyme-Linked Immunosorbent Assay
An in-house-developed enzyme-linked immunosorbent assay detected West Nile virus (WNV) immunoglobulin A (IgA) in 65 of 68 sera from WNV-infected patients; 40 of 63 WNV IgM-positive, IgG-negative serum or plasma specimens; 65 of 67 WNV IgM-positive, IgG-positive specimens; 0 of 70 WNV IgM-negative, IgG-negative specimens; and 0 of 64 archived blood donation sera. WNV IgA is thus highly prevalent among WNV-infected patients and typically appears after WNV IgM but before WNV IgG.
- Open Access
- 1 January 2004
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 42 (1) , 12-15
Utility of the Focus Technologies West Nile Virus Immunoglobulin M Capture Enzyme-Linked Immunosorbent Assay for Testing Cerebrospinal Fluid
Focus Technologies has developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) kit that utilizes recombinant West Nile virus (WNV) antigens to detect WNV IgM in serum. We evaluate here the utility of the kit for detecting WNV IgM in cerebrospinal fluid (CSF). The sensitivity was evaluated by using 52 CSF specimens from the 2002 WNV season that were positive in both the Public Health Service Laboratories WNV IgM ELISA and an in-house WNV IgM ELISA with native WNV antigen. The specificity was evaluated with two groups of specimens: (i) 73 CSF specimens submitted for in-house WNV IgM ELISA testing from February through April 2003 and yielding a negative WNV IgM result and (ii) 60 CSF specimens determined to be positive for another virus by PCR testing. Using these 185 CSF specimens at a screening dilution of 1:2, the kit was determined to be 100% sensitive and 100% specific. Endpoint titers were determined for 20 IgM-positive CSF specimens by testing serial twofold dilutions and ranged from 1:8 to 1:512. Index values (specimen absorbance value/calibrator absorbance value) for the screening dilution (1:2) showed no correlation with IgM titers, whereas index values for higher dilutions showed significant correlation with IgM titers. CSF screening dilutions of greater than 1:2 are not recommended, however, due to the risk of obtaining false-negative results. These findings show that the Focus Technologies WNV IgM capture ELISA, when utilized as recommended, offers accurate qualitative detection of WNV IgM in CSF specimens.
- 1 January 2004
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 42 (1) , 12-15
Open AccessUtility of the Focus Technologies West Nile Virus Immunoglobulin M Capture Enzyme-Linked Immunosorbent Assay for Testing Cerebrospinal Fluid
Focus Technologies has developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) kit that utilizes recombinant West Nile virus (WNV) antigens to detect WNV IgM in serum. We evaluate here the utility of the kit for detecting WNV IgM in cerebrospinal fluid (CSF). The sensitivity was evaluated by using 52 CSF specimens from the 2002 WNV season that were positive in both the Public Health Service Laboratories WNV IgM ELISA and an in-house WNV IgM ELISA with native WNV antigen. The specificity was evaluated with two groups of specimens: (i) 73 CSF specimens submitted for in-house WNV IgM ELISA testing from February through April 2003 and yielding a negative WNV IgM result and (ii) 60 CSF specimens determined to be positive for another virus by PCR testing. Using these 185 CSF specimens at a screening dilution of 1:2, the kit was determined to be 100% sensitive and 100% specific. Endpoint titers were determined for 20 IgM-positive CSF specimens by testing serial twofold dilutions and ranged from 1:8 to 1:512. Index values (specimen absorbance value/calibrator absorbance value) for the screening dilution (1:2) showed no correlation with IgM titers, whereas index values for higher dilutions showed significant correlation with IgM titers. CSF screening dilutions of greater than 1:2 are not recommended, however, due to the risk of obtaining false-negative results. These findings show that the Focus Technologies WNV IgM capture ELISA, when utilized as recommended, offers accurate qualitative detection of WNV IgM in CSF specimens.
- Open Access
- 1 September 2003
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 10 (5) , 764-768
Detection of West Nile Virus (WNV)-Specific Immunoglobulin M in a Reference Laboratory Setting during the 2002 WNV Season in the United States
Between 1 June and 31 December 2002, 30,677 serum samples and 4,554 cerebrospinal fluid (CSF) samples were tested for West Nile virus (WNV)-specific immunoglobulin M (IgM) by an in-house enzyme-linked immunosorbent assay (ELISA); 1,481 serum samples (4.8%) and 345 CSF samples (7.6%) were positive for WNV IgM. Positive samples were forwarded to public health service laboratories (PHSLs) for further testing. PHSLs supplied results from their WNV IgM ELISAs for 654 samples; 633 (97%) were positive. PHSLs supplied WNV plaque reduction neutralization test results for 128 samples; 123 (96%) were positive. WNV IgM seroconversion and seroreversion trends were evaluated for 749 patients who each provided two serum samples that were tested during the study period. Of 574 patients whose first serum sample was IgM negative, 41 (7%) seroconverted (the second serum sample was IgM positive); of 175 patients whose first serum sample was IgM positive, 22 (13%) seroreverted (the second serum sample was IgM negative). The seroreversion rate was directly proportional to the time between serum sample collection; whereas only 1% of patients whose sera were collected 60 days apart showed seroreversion. Conversion and reversion trends for CSF were evaluated for 68 patients. Of 54 patients whose first CSF specimen was IgM negative, 9 (17%) converted; none of 14 patients whose first CSF specimen was IgM positive reverted. Concomitant detection of WNV IgM in serum and CSF was assessed for 1,188 patients for whom paired serum and CSF specimens were available; for all 130 patients for whom IgM was detectable in CSF, IgM was also detectable in serum. These findings show that an in-house WNV IgM ELISA accurately identifies patients with WNV infection, document WNV IgM conversion and reversion trends, and demonstrate that WNV IgM detection in CSF is accompanied by WNV IgM detection in serum.
- 1 September 2003
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 10 (5) , 764-768
Open AccessDetection of West Nile Virus (WNV)-Specific Immunoglobulin M in a Reference Laboratory Setting during the 2002 WNV Season in the United States
Between 1 June and 31 December 2002, 30,677 serum samples and 4,554 cerebrospinal fluid (CSF) samples were tested for West Nile virus (WNV)-specific immunoglobulin M (IgM) by an in-house enzyme-linked immunosorbent assay (ELISA); 1,481 serum samples (4.8%) and 345 CSF samples (7.6%) were positive for WNV IgM. Positive samples were forwarded to public health service laboratories (PHSLs) for further testing. PHSLs supplied results from their WNV IgM ELISAs for 654 samples; 633 (97%) were positive. PHSLs supplied WNV plaque reduction neutralization test results for 128 samples; 123 (96%) were positive. WNV IgM seroconversion and seroreversion trends were evaluated for 749 patients who each provided two serum samples that were tested during the study period. Of 574 patients whose first serum sample was IgM negative, 41 (7%) seroconverted (the second serum sample was IgM positive); of 175 patients whose first serum sample was IgM positive, 22 (13%) seroreverted (the second serum sample was IgM negative). The seroreversion rate was directly proportional to the time between serum sample collection; whereas only 1% of patients whose sera were collected 60 days apart showed seroreversion. Conversion and reversion trends for CSF were evaluated for 68 patients. Of 54 patients whose first CSF specimen was IgM negative, 9 (17%) converted; none of 14 patients whose first CSF specimen was IgM positive reverted. Concomitant detection of WNV IgM in serum and CSF was assessed for 1,188 patients for whom paired serum and CSF specimens were available; for all 130 patients for whom IgM was detectable in CSF, IgM was also detectable in serum. These findings show that an in-house WNV IgM ELISA accurately identifies patients with WNV infection, document WNV IgM conversion and reversion trends, and demonstrate that WNV IgM detection in CSF is accompanied by WNV IgM detection in serum.