Jeffrey J. Popma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeffrey J. Popma has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
E. Magnus Ohman
2 shared publications- Eberhard Grube
Heart Center Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
2 shared publications Nicholas Cox
2 shared publicationsPeter Berger
2 shared publicationsRichard E. Kuntz
2 shared publications- Richard E. Kuntz
From the Divisions of Clinical Biometrics and Cardiovascular Medicine, Brigham and Women’s Hospital, and Harvard Medical School (J.C.W., L.M., R.E.K.), and the Department of Health Care Policy, Harvard Medical School and the Department of Biostatistics, Harvard School of Public Health (S.-L.T.N.), Boston, Mass
2 shared publications
Latest Publications
- 1 October 2014
- Vol. 26 (10) , 501-11
Serial intravascular ultrasound analysis of stent strut distribution and fracture: an integrated analysis of the taxus IV, V, and VI trials.
Non-uniform distribution of drug-eluting stent struts may cause uneven drug deposition associated with an adverse neointimal response and clinical events. This study assesses circumferential stent strut distribution in bare-metal (BMS) and paclitaxel-eluting (Taxus) stents post implantation and at 9-month follow-up, as well as its impact on intimal hyperplasia (IH). In the current analysis, intravascular ultrasound (IVUS) substudies of the Taxus IV, V, and VI trials were combined. Among them, 242 stents (117 BMS and 125 Taxus) had paired IVUS images post procedure and at 9-month follow-up that were reassessed at 1 mm intervals. Post implantation, the maximum interstrut angle (71.5 ± 17.7° vs 70.0 ± 19.6°; P=.53) and minimum number of stent struts (7.1 ± 1.0 vs 7.2 ± 0.8; P=.32) were similar in Taxus vs BMS subgroups, respectively. At 9-month follow-up, the maximum angle increased (92.8 ± 22.1° and 81.7 ± 20.6°) and stent strut numbers decreased (6.1 ± 0.9 and 6.5 ± 1.0) for both Taxus and BMS, respectively, as compared to immediately post implantation (all P<.001). The increased stent angle was more pronounced for Taxus compared with BMS (P<.01). Non-uniform strut distribution did not affect IH pattern or clinical outcomes in either stent population. No complete stent fractures were identified. Stent strut distribution changed from implantation to follow-up with an increased interstrut angle and fewer visible stent struts. These changes were more pronounced for Taxus as compared to BMS; however, non-uniform strut distribution was unrelated to increased IH or clinical outcomes.
- 1 October 2014
- Vol. 26 (10) , 501-11
Serial intravascular ultrasound analysis of stent strut distribution and fracture: an integrated analysis of the taxus IV, V, and VI trials.
Non-uniform distribution of drug-eluting stent struts may cause uneven drug deposition associated with an adverse neointimal response and clinical events. This study assesses circumferential stent strut distribution in bare-metal (BMS) and paclitaxel-eluting (Taxus) stents post implantation and at 9-month follow-up, as well as its impact on intimal hyperplasia (IH). In the current analysis, intravascular ultrasound (IVUS) substudies of the Taxus IV, V, and VI trials were combined. Among them, 242 stents (117 BMS and 125 Taxus) had paired IVUS images post procedure and at 9-month follow-up that were reassessed at 1 mm intervals. Post implantation, the maximum interstrut angle (71.5 ± 17.7° vs 70.0 ± 19.6°; P=.53) and minimum number of stent struts (7.1 ± 1.0 vs 7.2 ± 0.8; P=.32) were similar in Taxus vs BMS subgroups, respectively. At 9-month follow-up, the maximum angle increased (92.8 ± 22.1° and 81.7 ± 20.6°) and stent strut numbers decreased (6.1 ± 0.9 and 6.5 ± 1.0) for both Taxus and BMS, respectively, as compared to immediately post implantation (all P<.001). The increased stent angle was more pronounced for Taxus compared with BMS (P<.01). Non-uniform strut distribution did not affect IH pattern or clinical outcomes in either stent population. No complete stent fractures were identified. Stent strut distribution changed from implantation to follow-up with an increased interstrut angle and fewer visible stent struts. These changes were more pronounced for Taxus as compared to BMS; however, non-uniform strut distribution was unrelated to increased IH or clinical outcomes.
- 1 March 2010
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 75 (S1) , S43-S45
Conclusion
- 1 March 2010
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 75 (S1) , S43-S45
Conclusion
- 15 July 2009
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 74 (7) , 1130
Rebuttal:Reply to the letter to the editor by Dr. Hirsh
- 15 July 2009
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 74 (7) , 1130
Rebuttal:Reply to the letter to the editor by Dr. Hirsh
- 14 April 2009
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 22 (s1) , S64-S71
Angiographic Markers of Restenosis after Drug‐Eluting Stent Implantation: Surrogates for Late Clinical Outcomes?
- 14 April 2009
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 22 (s1) , S64-S71
Angiographic Markers of Restenosis after Drug‐Eluting Stent Implantation: Surrogates for Late Clinical Outcomes?
- 1 May 2007
- Vol. 3 (1) , 76-81
Safety of direct stenting with the Endeavor stent: results of the Endeavor II continued access registry.
The safety and efficacy of direct stenting with the Endeavor stent is unknown. The acute and 9 month outcome after direct stenting vs. predilatation was tested in a multicentre, prospective, single-arm study. 300 patients were treated with the Endeavor stent for a single, previously untreated coronary artery stenosis (vessel diameter 2.25 to 3.75 mm; lesion length 14 to 27 mm). Predilatation was at discretion of the operator for lesions < 20 mm in length but mandatory for lesions > 20 mm. Angiographic follow-up at 8 months was prespecified for the first 150 consecutive patients. Out of 296 patients, 126 (42.6%) underwent direct stenting and 170 (57.4%) predilatation. Patients in the direct stenting group were younger (62.9 years vs 65.3 years, P=0.04) and lesions were predictably more proximally located and shorter (14.29 mm vs 18.16 mm, P<0.0001), with larger pre-procedural minimum lumen diameter. Success rate was 92.9% with direct stenting vs. 95.3% with predilatation (P=0.45). At 8 months, late loss was not significantly different between groups. The rate of MACE at 9 months was 10.6% with direct stenting vs. 10.2% with predilatation (P=1.00). There were no occurrences of stent thrombosis in either group. Direct stenting with the Endeavor stent as deemed feasible by the operator, was safe and effective, and comparable to the results of implantation following predilatation.
- 1 May 2007
- Vol. 3 (1) , 76-81
Safety of direct stenting with the Endeavor stent: results of the Endeavor II continued access registry.
The safety and efficacy of direct stenting with the Endeavor stent is unknown. The acute and 9 month outcome after direct stenting vs. predilatation was tested in a multicentre, prospective, single-arm study. 300 patients were treated with the Endeavor stent for a single, previously untreated coronary artery stenosis (vessel diameter 2.25 to 3.75 mm; lesion length 14 to 27 mm). Predilatation was at discretion of the operator for lesions < 20 mm in length but mandatory for lesions > 20 mm. Angiographic follow-up at 8 months was prespecified for the first 150 consecutive patients. Out of 296 patients, 126 (42.6%) underwent direct stenting and 170 (57.4%) predilatation. Patients in the direct stenting group were younger (62.9 years vs 65.3 years, P=0.04) and lesions were predictably more proximally located and shorter (14.29 mm vs 18.16 mm, P<0.0001), with larger pre-procedural minimum lumen diameter. Success rate was 92.9% with direct stenting vs. 95.3% with predilatation (P=0.45). At 8 months, late loss was not significantly different between groups. The rate of MACE at 9 months was 10.6% with direct stenting vs. 10.2% with predilatation (P=1.00). There were no occurrences of stent thrombosis in either group. Direct stenting with the Endeavor stent as deemed feasible by the operator, was safe and effective, and comparable to the results of implantation following predilatation.
- 21 December 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (25) , 3773-3780
Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary Arteries
Background— Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. Methods and Results— Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P P P Conclusions— Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.
- 21 December 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (25) , 3773-3780
Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary Arteries
Background— Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. Methods and Results— Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P P P Conclusions— Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 125-134
Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention
Percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) and native coronary arteries may be associated with embolization of particulate debris into the distal microcirculation. The FilterWire uses a polyurethane filter bag contained on a radiopaque loop to trap embolic debris during native vessel and SVG intervention. The objectives of this study were to assess the feasibility and safety of the FilterWire during PCI and to examine the size and content of the particulate debris captured during SVG and native vessel intervention. Early angiographic, in‐hospital, and 30‐day clinical outcomes were reviewed in 35 patients with 36 lesions treated with the FilterWire during PCI. Lesions were located in 22 (61%) native coronary arteries and in 14 (39%) SVGs. Multivessel coronary artery disease was present in 75% of patients. Lesions were complex (ACC/AHA complexity B2 or C) in 81% of cases. The FilterWire was successfully delivered and deployed distal to the site of coronary intervention in 92% of lesions, including 95% of native vessels and 82% of SVG lesions. Embolic debris was entrapped in 82% of these cases. The average particulate debris had a mean major axis of 490 μm (range, 45–3,302 μm) and minor axis of 226 μm (range, 33–1,677 μm). Although reduced flow was common (36.1%) when the FilterWire was in place, there were no sustained episodes of abrupt closure and only one (2.8%) patient developed sustained no‐reflow after FilterWire removal. Distal branch vessel embolization was found in four (11.1%) cases. Major adverse cardiac events occurred in 5 (14%) of 35 patients treated with the device, although 2 of these patients were evolving an acute myocardial infarction at the time of the procedure; in patients meeting the prospectively defined inclusion criteria, the major adverse cardiac event was 6%. These results suggest that the FilterWire is a feasible and safe method of collecting particulate debris released during SVG and native vessel coronary intervention. Its benefit over conventional therapy and other distal protection devices is currently under study. Cathet Cardiovasc Intervent 2002;57:125–134.
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 125-134
Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention
Percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) and native coronary arteries may be associated with embolization of particulate debris into the distal microcirculation. The FilterWire uses a polyurethane filter bag contained on a radiopaque loop to trap embolic debris during native vessel and SVG intervention. The objectives of this study were to assess the feasibility and safety of the FilterWire during PCI and to examine the size and content of the particulate debris captured during SVG and native vessel intervention. Early angiographic, in‐hospital, and 30‐day clinical outcomes were reviewed in 35 patients with 36 lesions treated with the FilterWire during PCI. Lesions were located in 22 (61%) native coronary arteries and in 14 (39%) SVGs. Multivessel coronary artery disease was present in 75% of patients. Lesions were complex (ACC/AHA complexity B2 or C) in 81% of cases. The FilterWire was successfully delivered and deployed distal to the site of coronary intervention in 92% of lesions, including 95% of native vessels and 82% of SVG lesions. Embolic debris was entrapped in 82% of these cases. The average particulate debris had a mean major axis of 490 μm (range, 45–3,302 μm) and minor axis of 226 μm (range, 33–1,677 μm). Although reduced flow was common (36.1%) when the FilterWire was in place, there were no sustained episodes of abrupt closure and only one (2.8%) patient developed sustained no‐reflow after FilterWire removal. Distal branch vessel embolization was found in four (11.1%) cases. Major adverse cardiac events occurred in 5 (14%) of 35 patients treated with the device, although 2 of these patients were evolving an acute myocardial infarction at the time of the procedure; in patients meeting the prospectively defined inclusion criteria, the major adverse cardiac event was 6%. These results suggest that the FilterWire is a feasible and safe method of collecting particulate debris released during SVG and native vessel coronary intervention. Its benefit over conventional therapy and other distal protection devices is currently under study. Cathet Cardiovasc Intervent 2002;57:125–134.
- 27 August 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (9) , 1090-1096
Randomized Trial of 90 Sr/ 90 Y β-Radiation Versus Placebo Control for Treatment of In-Stent Restenosis
Background— After conventional treatment of in-stent restenosis, the incidence of recurrent clinical restenosis may approach 40%. We report the first multicenter, blinded, and randomized trial of intracoronary radiation with the use of a 90 Sr/ 90 Y β-source for the treatment of in-stent restenosis. Methods and Results— After successful catheter-based treatment of in-stent restenosis, 476 patients were randomly assigned to receive an intracoronary catheter containing either 90 Sr/ 90 Y (n=244) or placebo (n=232) sources. The prescribed dose 2 mm from the center of the source was 18.4 Gy for vessels between 2.70 and 3.35 mm in diameter and 23.0 Gy for vessels between 3.36 and 4.0 mm. The primary end point, ie, clinically driven target-vessel revascularization by 8 months, was observed in 56 (26.8%) of the patients assigned to placebo and 39 (17.0%) of the patients assigned to radiation ( P =0.015). The incidence of the composite including death, myocardial infarction, and target-vessel revascularization was observed in 60 (28.7%) of the patients assigned to placebo and 44 (19.1%) of the patients assigned to radiation ( P =0.024). Binary 8-month angiographic restenosis (≥50% diameter stenosis) within the entire segment treated with radiation was reduced from 45.2% in the placebo-treated patients to 28.8% in the 90 Sr/ 90 Y-treated patients ( P =0.001). Stent thromboses occurred in 1 patient assigned to placebo 90 Sr/ 90 Y at day 244. Conclusions— The results of this study demonstrated that β-radiation using 90 Sr/ 90 Y is both safe and effective for preventing recurrence in patients with in-stent restenosis.
- 27 August 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (9) , 1090-1096
Randomized Trial of 90 Sr/ 90 Y β-Radiation Versus Placebo Control for Treatment of In-Stent Restenosis
Background— After conventional treatment of in-stent restenosis, the incidence of recurrent clinical restenosis may approach 40%. We report the first multicenter, blinded, and randomized trial of intracoronary radiation with the use of a 90 Sr/ 90 Y β-source for the treatment of in-stent restenosis. Methods and Results— After successful catheter-based treatment of in-stent restenosis, 476 patients were randomly assigned to receive an intracoronary catheter containing either 90 Sr/ 90 Y (n=244) or placebo (n=232) sources. The prescribed dose 2 mm from the center of the source was 18.4 Gy for vessels between 2.70 and 3.35 mm in diameter and 23.0 Gy for vessels between 3.36 and 4.0 mm. The primary end point, ie, clinically driven target-vessel revascularization by 8 months, was observed in 56 (26.8%) of the patients assigned to placebo and 39 (17.0%) of the patients assigned to radiation ( P =0.015). The incidence of the composite including death, myocardial infarction, and target-vessel revascularization was observed in 60 (28.7%) of the patients assigned to placebo and 44 (19.1%) of the patients assigned to radiation ( P =0.024). Binary 8-month angiographic restenosis (≥50% diameter stenosis) within the entire segment treated with radiation was reduced from 45.2% in the placebo-treated patients to 28.8% in the 90 Sr/ 90 Y-treated patients ( P =0.001). Stent thromboses occurred in 1 patient assigned to placebo 90 Sr/ 90 Y at day 244. Conclusions— The results of this study demonstrated that β-radiation using 90 Sr/ 90 Y is both safe and effective for preventing recurrence in patients with in-stent restenosis.