Guor‐Rong Her
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guor‐Rong Her has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Fu-An Li
Institute of Biomedical Sciences, Academia Sinica, Taipei 115201, Taiwan, Taiwan
7 shared publications - Chao-Jung Chen
Graduate Institute of Integrated Medicine, China Medical University, Taichung, Taiwan; Proteomics Core Laboratory, Department of Medical Research, China Medical University Hospital, Taichung, Taiwan
5 shared publications Che‐Wei Wang
Department of Chemistry, National Taiwan University, Taipei, Taiwan
4 shared publicationsJu‐Li Huang
Department of Chemistry, National Taiwan University, Taipei, Taiwan
3 shared publicationsMei‐Chun Tseng
Institute of Chemistry, Academia Sinica, Taipei, Taiwan
3 shared publicationsSih-Hua Hung
Department of Chemistry, National Taiwan University, Taipei, Taiwan
3 shared publications
Latest Publications
- Open Access
- 14 December 2021
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 29 (4) , 738-750
Variations in bovine milk oligosaccharides after calving using p-aminobenzoic ethyl ester closed-ring labeling and negative ion electrospray LC/MS/MS
A strategy was proposed to analyze bovine milk oligosaccharides using p-aminobenzoic ethyl ester (ABEE) closed-ring labeling and C18 capillary liquid chromatography negative ion electrospray tandem mass spectrometry. Linkage specific fragment ions were used to identify oligosaccharide isomers. By constructing the mass chromatograms using linkage specific fragment ions, isomers were differentiated based on m/z values as well as temporal separation provided by liquid chromatography. In addition to disialyllactose and the single isomer lacto-N-neohexaose, four pairs of linkage isomers including 3’/6’-sialyllactose (3’/6’-SL), 3’/6’-sialyllactosamine (3’/6’-SLN), 3’/6’-sialylgalactosyl-lactose (3’/6’-SGL), and lacto-N-tetraose/lacto-N-neotetraose (LNT/LNnT) in bovine milk were investigated. Variations of bovine milk oligosaccharides in a lactation period of 72 hrs after calving were studied. Sialylated oligosaccharide was found to be distinctively more abundant in milk of the first 24 hrs, decreasing in successive milkings. For the first time, the variation of lacto-N-tetraose in bovine milk was reported.
- 14 December 2021
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 29 (4) , 738-750
Open AccessVariations in bovine milk oligosaccharides after calving using p-aminobenzoic ethyl ester closed-ring labeling and negative ion electrospray LC/MS/MS
A strategy was proposed to analyze bovine milk oligosaccharides using p-aminobenzoic ethyl ester (ABEE) closed-ring labeling and C18 capillary liquid chromatography negative ion electrospray tandem mass spectrometry. Linkage specific fragment ions were used to identify oligosaccharide isomers. By constructing the mass chromatograms using linkage specific fragment ions, isomers were differentiated based on m/z values as well as temporal separation provided by liquid chromatography. In addition to disialyllactose and the single isomer lacto-N-neohexaose, four pairs of linkage isomers including 3’/6’-sialyllactose (3’/6’-SL), 3’/6’-sialyllactosamine (3’/6’-SLN), 3’/6’-sialylgalactosyl-lactose (3’/6’-SGL), and lacto-N-tetraose/lacto-N-neotetraose (LNT/LNnT) in bovine milk were investigated. Variations of bovine milk oligosaccharides in a lactation period of 72 hrs after calving were studied. Sialylated oligosaccharide was found to be distinctively more abundant in milk of the first 24 hrs, decreasing in successive milkings. For the first time, the variation of lacto-N-tetraose in bovine milk was reported.
- 1 September 2016
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 51 (10) , 883-888
Gas chromatography electrospray ionization mass spectrometry analysis of trimethylsilyl derivatives
A method based on the analysis of trimethylsilyl (TMS) derivatives by capillary gas chromatography electrospray ionization mass spectrometry (GC–ESI/MS) was proposed. To improve separation, analytes were derivatized to their TMS derivative. During ESI analysis, TMS derivatives may hydrolyze back to their polar native form and are thus suitable for ESI analysis. Several types of analytes were studied to investigate the potential of the approach. Not all TMS derivatives hydrolyzed back to their native form as anticipated. Incomplete hydrolysis was observed for TMS‐organic acids and TMS‐nonchlorinated phenols. For TMS‐chlorophenols, the observation of only the [M − H]− ion suggested that these phenols were hydrolyzed back to their native form. For TMS‐beta agonists, the hydrolysis rate was low; therefore, the hydrolysis product was not detected. Both TMS‐chlorophenols and TMS‐beta agonists provide a sensitivity in the range of low parts per billion (0.25–5 ng/ml and 0.5–10 ng/ml respectively). Copyright © 2016 John Wiley & Sons, Ltd.
- 1 September 2016
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 51 (10) , 883-888
Gas chromatography electrospray ionization mass spectrometry analysis of trimethylsilyl derivatives
A method based on the analysis of trimethylsilyl (TMS) derivatives by capillary gas chromatography electrospray ionization mass spectrometry (GC–ESI/MS) was proposed. To improve separation, analytes were derivatized to their TMS derivative. During ESI analysis, TMS derivatives may hydrolyze back to their polar native form and are thus suitable for ESI analysis. Several types of analytes were studied to investigate the potential of the approach. Not all TMS derivatives hydrolyzed back to their native form as anticipated. Incomplete hydrolysis was observed for TMS‐organic acids and TMS‐nonchlorinated phenols. For TMS‐chlorophenols, the observation of only the [M − H]− ion suggested that these phenols were hydrolyzed back to their native form. For TMS‐beta agonists, the hydrolysis rate was low; therefore, the hydrolysis product was not detected. Both TMS‐chlorophenols and TMS‐beta agonists provide a sensitivity in the range of low parts per billion (0.25–5 ng/ml and 0.5–10 ng/ml respectively). Copyright © 2016 John Wiley & Sons, Ltd.
- 1 August 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 933, 156-163
An integrated electrophoretic mobility control device with split design for signal improvement in liquid chromatography–electrospray ionization mass spectrometry analysis of aminoglycosides using a heptafluorobutyric acid containing mobile phase
- 1 August 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 933, 156-163
An integrated electrophoretic mobility control device with split design for signal improvement in liquid chromatography–electrospray ionization mass spectrometry analysis of aminoglycosides using a heptafluorobutyric acid containing mobile phase
- 1 June 2016
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 22 (3) , 145-150
The Formation of a M + 2 Compound in the Analysis of a Trimethylsilyl Derivative of Monocarboxylic Acids by Gas Chromatography Electrospray Ionization Mass Spectrometry
The trimethylsilyl (TMS) derivative is one of the most widely utilized derivatives for analyzing polar compounds by gas chromatography. An ion two mass units higher than the protonated molecular ion was observed in analyzing TMS-monocarboxylic acids by using gas chromatography electrospray ionization mass spectrometry (GC-ESI/MS). The structure of the M + 2 compound was investigated using tandem mass spectrometry and high-resolution mass spectrometry. The results suggest that one methyl group bound to the silicon atom was replaced by a hydroxyl group during the ESI process. One possible mechanism for the formation of the M + 2 compound is proposed. This observation suggests the possibility of synthesizing an organic compound by using ESI.
- 1 June 2016
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 22 (3) , 145-150
The Formation of a M + 2 Compound in the Analysis of a Trimethylsilyl Derivative of Monocarboxylic Acids by Gas Chromatography Electrospray Ionization Mass Spectrometry
The trimethylsilyl (TMS) derivative is one of the most widely utilized derivatives for analyzing polar compounds by gas chromatography. An ion two mass units higher than the protonated molecular ion was observed in analyzing TMS-monocarboxylic acids by using gas chromatography electrospray ionization mass spectrometry (GC-ESI/MS). The structure of the M + 2 compound was investigated using tandem mass spectrometry and high-resolution mass spectrometry. The results suggest that one methyl group bound to the silicon atom was replaced by a hydroxyl group during the ESI process. One possible mechanism for the formation of the M + 2 compound is proposed. This observation suggests the possibility of synthesizing an organic compound by using ESI.
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 843, 27-37
Structural analysis of isomeric chondroitin sulfate oligosaccharides using regioselective 6-O-desulfation method and tandem mass spectrometry
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 843, 27-37
Structural analysis of isomeric chondroitin sulfate oligosaccharides using regioselective 6-O-desulfation method and tandem mass spectrometry
- 14 December 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (9) , 1251-1258
The development of a counterflow‐assisted preconcentration technique in capillary electrophoresis electrospray‐ionization mass spectrometry
A preconcentration approach for CE-MS using counterflow-assisted electrokinetic injection was proposed. The proposed preconcentration method was based on a counterflow-compatible sheathless interface. The interface was fabricated using a capillary-assembled PDMS microdevice that allowed the application of a counterflow and provided liquid-film electrical conduction. During electrokinetic injection, a hydrodynamic counterflow was introduced into the separation capillary to retard the movement of the stacking boundary to the CE outlet. Accordingly, a long injection time was achieved without a loss of CE separation. With the use of reverse polarity mode and a dynamic polybrene-coated separation capillary (filled with a 1% formic acid solution), a counterflow-assisted electrokinetic injection of peptide samples (in a aqueous solution containing 1% ammonia and 50% methanol) for 10 min provided a sensitivity enhancement of 750–1480 and a detection limit of 20 pM for the five peptide standards. The proposed technique was applied to the analysis of low nanomolar concentrations myoglobin tryptic peptides.
- 14 December 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (9) , 1251-1258
The development of a counterflow‐assisted preconcentration technique in capillary electrophoresis electrospray‐ionization mass spectrometry
A preconcentration approach for CE-MS using counterflow-assisted electrokinetic injection was proposed. The proposed preconcentration method was based on a counterflow-compatible sheathless interface. The interface was fabricated using a capillary-assembled PDMS microdevice that allowed the application of a counterflow and provided liquid-film electrical conduction. During electrokinetic injection, a hydrodynamic counterflow was introduced into the separation capillary to retard the movement of the stacking boundary to the CE outlet. Accordingly, a long injection time was achieved without a loss of CE separation. With the use of reverse polarity mode and a dynamic polybrene-coated separation capillary (filled with a 1% formic acid solution), a counterflow-assisted electrokinetic injection of peptide samples (in a aqueous solution containing 1% ammonia and 50% methanol) for 10 min provided a sensitivity enhancement of 750–1480 and a detection limit of 20 pM for the five peptide standards. The proposed technique was applied to the analysis of low nanomolar concentrations myoglobin tryptic peptides.
- 7 October 2013
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 27 (22) , 2530-2538
Comparative study of sialyl glycoprotein with multiple glycosylation sites using isotope labeling and capillary liquid chromatography/mass spectrometry
RATIONALE: A comparative strategy has been demonstrated using RNase B, a single‐site N‐linked high‐mannose glycoprotein. Glycoproteins are more common with multiple glycosylation sites and with complex glycans. A strategy capable of differentiating the changes caused by glycoprotein concentration, glycosylation site occupancy, and a glycoform profile of complex glycoproteins would be beneficial. METHODS: Tryptic‐digested glycoproteins were labeled using 12 C,H‐formaldehyde and 13 C, D‐formaldehyde, purified, and then analyzed using capillary reversed‐phase liquid chromatography/mass spectrometry (RPLC/MS). The relative intensity of non‐glycosylated peptides provided information on glycoprotein concentration variation. A site‐specific glycoform profile variation was obtained by comparing the glycoform profile of CH 2 and 13 CD 2 glycopeptides. Determining the protein concentration and glycoform profile variations allows the glycosylation site occupancy variation to be calculated. RESULTS: A strong correlation between the observed and prepared ratios for fetuin glycopeptides from 0.2 to 5 was obtained. Two fetuin samples with different glycoprotein concentrations (4‐fold change), glycoform profiles (normal and modified), and glycosylation site occupancies (100% and 50%) were prepared, labeled, mixed, purified, and analyzed using RPLC/MS. The results of the comparative study had a strong correlation with the prepared values. CONCLUSIONS: In this report, we demonstrated a comparative analysis of fetuin, a glycoprotein with multiple glycosylation sites and complex sialyl glycans. Compared to our previous approach, we made several modifications including the use of RPLC, a larger mass difference isotope tag, and isotope overlapping correction. The modified approach is expected to be applicable to most glycoproteins. Copyright © 2013 John Wiley & Sons, Ltd.
- 7 October 2013
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 27 (22) , 2530-2538
Comparative study of sialyl glycoprotein with multiple glycosylation sites using isotope labeling and capillary liquid chromatography/mass spectrometry
RATIONALE: A comparative strategy has been demonstrated using RNase B, a single‐site N‐linked high‐mannose glycoprotein. Glycoproteins are more common with multiple glycosylation sites and with complex glycans. A strategy capable of differentiating the changes caused by glycoprotein concentration, glycosylation site occupancy, and a glycoform profile of complex glycoproteins would be beneficial. METHODS: Tryptic‐digested glycoproteins were labeled using 12 C,H‐formaldehyde and 13 C, D‐formaldehyde, purified, and then analyzed using capillary reversed‐phase liquid chromatography/mass spectrometry (RPLC/MS). The relative intensity of non‐glycosylated peptides provided information on glycoprotein concentration variation. A site‐specific glycoform profile variation was obtained by comparing the glycoform profile of CH 2 and 13 CD 2 glycopeptides. Determining the protein concentration and glycoform profile variations allows the glycosylation site occupancy variation to be calculated. RESULTS: A strong correlation between the observed and prepared ratios for fetuin glycopeptides from 0.2 to 5 was obtained. Two fetuin samples with different glycoprotein concentrations (4‐fold change), glycoform profiles (normal and modified), and glycosylation site occupancies (100% and 50%) were prepared, labeled, mixed, purified, and analyzed using RPLC/MS. The results of the comparative study had a strong correlation with the prepared values. CONCLUSIONS: In this report, we demonstrated a comparative analysis of fetuin, a glycoprotein with multiple glycosylation sites and complex sialyl glycans. Compared to our previous approach, we made several modifications including the use of RPLC, a larger mass difference isotope tag, and isotope overlapping correction. The modified approach is expected to be applicable to most glycoproteins. Copyright © 2013 John Wiley & Sons, Ltd.
- 10 September 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (21-22) , 3635-3643
A convenient and sensitive method for haloacetic acid analysis in tap water by on‐line field‐amplified sample‐stacking CE–ESI‐MS
In this study, we propose a simple strategy based on flow injection and field‐amplified sample‐stacking CE–ESI‐MS/MS to analyze haloacetic acids (HAAs) in tap water. Tap water was passed through a desalination cartridge before field‐amplified sample‐stacking CE–ESI‐MS/MS analysis to reduce sample salinity. With this treatment, the signals of the HAAs increased 300‐ to 1400‐fold. The LODs for tap water analysis were in the range of 10 to 100 ng/L, except for the LOD of monochloroacetic acid (1 μg/L in selected‐ion monitoring mode detection). The proposed method is fast, convenient, and sensitive enough to perform on‐line analysis of five HAAs in the tap water of Taipei City. Four HAAs, including trichloroacetic acid, dichloroacetic acid, dibromoacetic acid, and monobromoacetic acid, were detected at concentrations of approximately 1.74, 1.15, 0.16, and 0.15 ppb, respectively.
- 10 September 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (21-22) , 3635-3643
A convenient and sensitive method for haloacetic acid analysis in tap water by on‐line field‐amplified sample‐stacking CE–ESI‐MS
In this study, we propose a simple strategy based on flow injection and field‐amplified sample‐stacking CE–ESI‐MS/MS to analyze haloacetic acids (HAAs) in tap water. Tap water was passed through a desalination cartridge before field‐amplified sample‐stacking CE–ESI‐MS/MS analysis to reduce sample salinity. With this treatment, the signals of the HAAs increased 300‐ to 1400‐fold. The LODs for tap water analysis were in the range of 10 to 100 ng/L, except for the LOD of monochloroacetic acid (1 μg/L in selected‐ion monitoring mode detection). The proposed method is fast, convenient, and sensitive enough to perform on‐line analysis of five HAAs in the tap water of Taipei City. Four HAAs, including trichloroacetic acid, dichloroacetic acid, dibromoacetic acid, and monobromoacetic acid, were detected at concentrations of approximately 1.74, 1.15, 0.16, and 0.15 ppb, respectively.
- 17 June 2013
- Published by Wiley in Electrophoresis
- Vol. 34 (17) , 2538-2545
Sheathless capillary electrophoresis electrospray ionization‐mass spectrometry interface based on poly(dimethylsiloxane) membrane emitter and thin conducting liquid film
This study develops a sheathless CE‐MS interface using a robust PDMS membrane emitter and liquid‐film electric conduction. A 3D mold was constructed for casting the device by using a one‐step casting procedure. The interface consisted of a 125 μm‐thick triangular emitter with a 50 μm‐diameter microchannel, a conducting reservoir, and a 375 μm‐diameter channel for assembling the separation capillary. The separation capillary was inserted into the 375 μm channel and connected to the emitter through the conducting reservoir. The electric contact for the CE outlet was established through a conductive liquid film in the space between the capillary terminus and the 375 μm channel. The one‐step casting procedure and using a membrane emitter instead of a tapered emitter produced an easily fabricated and robust interface. A stable electrospray was obtained from 30 to 350 nL/min. Analyzing a five‐peptide mixture in low‐EOF (60 nL/min) and high‐EOF (210 nL/min) conditions demonstrated the utility of the interface.
- 17 June 2013
- Published by Wiley in Electrophoresis
- Vol. 34 (17) , 2538-2545
Sheathless capillary electrophoresis electrospray ionization‐mass spectrometry interface based on poly(dimethylsiloxane) membrane emitter and thin conducting liquid film
This study develops a sheathless CE‐MS interface using a robust PDMS membrane emitter and liquid‐film electric conduction. A 3D mold was constructed for casting the device by using a one‐step casting procedure. The interface consisted of a 125 μm‐thick triangular emitter with a 50 μm‐diameter microchannel, a conducting reservoir, and a 375 μm‐diameter channel for assembling the separation capillary. The separation capillary was inserted into the 375 μm channel and connected to the emitter through the conducting reservoir. The electric contact for the CE outlet was established through a conductive liquid film in the space between the capillary terminus and the 375 μm channel. The one‐step casting procedure and using a membrane emitter instead of a tapered emitter produced an easily fabricated and robust interface. A stable electrospray was obtained from 30 to 350 nL/min. Analyzing a five‐peptide mixture in low‐EOF (60 nL/min) and high‐EOF (210 nL/min) conditions demonstrated the utility of the interface.