Gilles Dupré
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gilles Dupré has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Barbara Bockstahler
Section of Physical Therapy and Rehabilitation, Small Animals Surgery, Clinical Centre for Small Animal Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine, 1210 Vienna, Austria
2 shared publications Judith Doerner
Clinic for Small Animal Surgery, Ophthalmology, Dentistry, Physiotherapy and Rehabilitation, Department of Small Animals and Horses, University of Veterinary Medicine, Vienna, Austria
2 shared publicationsValentina Fiorbianco
2 shared publications- Anja Becher-Deichsel
Clinic for Obstetrics, Division of Gynecology and Andrology, University of Veterinary Medicine Vienna, 1210 Vienna, Austria
1 shared publication - Christian Peham
Movement Science Group, Clinical Centre for Equine Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine, 1210 Vienna, Austria
1 shared publication Dorothee Heidenreich
Department for Small Animal and Equine, Vetmeduni Vienna, Veterinary Medicine University, Veterinärplatz 1, A-1210 Vienna, Austria
1 shared publication
Latest Publications
- Open Access
Pressure–Volume Curve during Capnoperitoneum in Cats
Laparoscopy is a growing field in veterinary medicine, although guidelines are lacking. The objective of this study was to evaluate the pressure–volume curve during capnoperitoneum in cats. A total of 59 female cats were scheduled for routine laparoscopy. Pressure and volume data were recorded and processed, and the yield point of the curve was calculated using a method based on a capacitor discharging function. For the remaining 40 cats, a linear-like pressure–volume curve was observed until a yield point with a mean cutoff pressure (COP) of 6.44 ± 1.7 mmHg (SD) (range, 2.72–13.00 mmHg) and a mean cutoff volume (COV) of 387 ± 144.35 mL (SD) (range, 178.84–968.43 mL) was reached. The mean mL/kg CO2 value in cats was 208 ± 34.69 mL/kg (range, 100.00–288.46 mL/kg). The COV correlated with COP and body weight but not with body condition score (BCS). COP correlated only with the COV. This study suggests that feline patients have a pressure–volume curve similar to that of canine patients, and the same pressure limit recommendations can be used for both species. After a yield point of 6.44 mmHg is reached, the increment in volume decreases exponentially as the intra-abdominal pressure (IAP) increases.
Open AccessPressure–Volume Curve during Capnoperitoneum in Cats
Laparoscopy is a growing field in veterinary medicine, although guidelines are lacking. The objective of this study was to evaluate the pressure–volume curve during capnoperitoneum in cats. A total of 59 female cats were scheduled for routine laparoscopy. Pressure and volume data were recorded and processed, and the yield point of the curve was calculated using a method based on a capacitor discharging function. For the remaining 40 cats, a linear-like pressure–volume curve was observed until a yield point with a mean cutoff pressure (COP) of 6.44 ± 1.7 mmHg (SD) (range, 2.72–13.00 mmHg) and a mean cutoff volume (COV) of 387 ± 144.35 mL (SD) (range, 178.84–968.43 mL) was reached. The mean mL/kg CO2 value in cats was 208 ± 34.69 mL/kg (range, 100.00–288.46 mL/kg). The COV correlated with COP and body weight but not with body condition score (BCS). COP correlated only with the COV. This study suggests that feline patients have a pressure–volume curve similar to that of canine patients, and the same pressure limit recommendations can be used for both species. After a yield point of 6.44 mmHg is reached, the increment in volume decreases exponentially as the intra-abdominal pressure (IAP) increases.
- Top Cited Papers
- 1 July 2016
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 46 (4) , 691-707
Brachycephalic Syndrome
- 1 July 2016
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 46 (4) , 691-707
Top Cited PapersBrachycephalic Syndrome
- Open Access
- 16 August 2015
- Published by Springer Nature in BMC Veterinary Research
- Vol. 11 (1) , 212
Mapping system for portal placement in laparoscopic procedures of small animals
Current recommendations for portal placement in laparoscopy are often imprecise. The aim of this study was to establish and evaluate a mapping system for portal placement during laparoscopic procedures in small animals. Sixty-four final-year veterinary students took part in this in papyro study. Descriptions of portal placements of two recent veterinary laparoscopic papers were randomly chosen as templates. The students performed portal placement based either on the description in the papers or based on the orthogonal mapping system for portal placement developed by the authors in a previous pilot study. The participants were randomly divided into two groups and asked to virtually chart positions of the portals on two photographs of a dog’s abdomen. Group A (n = 31) placed the portals using the mapping system, and Group B (n = 33) placed the portals based on the explanations provided in two randomly selected studies. Group A achieved an overall correct placement rate of 94.91 % (87.1–100.0 %) with an overall mean distance of 1.31 mm (0.00–3.61 mm) from the desired placement points. Group B achieved an overall correct placement rate of 40.8 % (3.1–93.3 %) with an overall mean distance of 16.97 mm (7.17–27.63 mm) from the desired placement points. The students in Group A performed significantly better than did students in Group B (P < .05). Use of the mapping system significantly improved correct portal placement in a dog photograph model. Use of such systems in laparoscopy may help facilitate correct portal placement and improve the repeatability of procedures, especially for the novice surgeon.
- 16 August 2015
- Published by Springer Nature in BMC Veterinary Research
- Vol. 11 (1) , 212
Open AccessMapping system for portal placement in laparoscopic procedures of small animals
Current recommendations for portal placement in laparoscopy are often imprecise. The aim of this study was to establish and evaluate a mapping system for portal placement during laparoscopic procedures in small animals. Sixty-four final-year veterinary students took part in this in papyro study. Descriptions of portal placements of two recent veterinary laparoscopic papers were randomly chosen as templates. The students performed portal placement based either on the description in the papers or based on the orthogonal mapping system for portal placement developed by the authors in a previous pilot study. The participants were randomly divided into two groups and asked to virtually chart positions of the portals on two photographs of a dog’s abdomen. Group A (n = 31) placed the portals using the mapping system, and Group B (n = 33) placed the portals based on the explanations provided in two randomly selected studies. Group A achieved an overall correct placement rate of 94.91 % (87.1–100.0 %) with an overall mean distance of 1.31 mm (0.00–3.61 mm) from the desired placement points. Group B achieved an overall correct placement rate of 40.8 % (3.1–93.3 %) with an overall mean distance of 16.97 mm (7.17–27.63 mm) from the desired placement points. The students in Group A performed significantly better than did students in Group B (P < .05). Use of the mapping system significantly improved correct portal placement in a dog photograph model. Use of such systems in laparoscopy may help facilitate correct portal placement and improve the repeatability of procedures, especially for the novice surgeon.
- 1 February 2013
- Published by Wiley in Veterinary Surgery
- Vol. 42 (5) , 579-585
Laparoscopic‐Assisted Placement of a Peritoneal Dialysis Catheter With Partial Omentectomy and Omentopexy in Dogs: An Experimental Study
Objective: To describe a technique of laparoscopic‐assisted placement of a peritoneal dialysis (PD) catheter with simultaneously performed partial omentectomy and omentopexy.Study Design: Pilot experimental study.Animals: Beagle dogs (n = 6).Methods: After placement of 1 sub‐umbilical laparoscope portal and 1 instrument portal in the left cranial abdominal quadrant, laparoscopic‐assisted partial omentectomy, and omentopexy were performed, and a modified Tenckhoff PD catheter was placed under laparoscopic guidance. A modified dialysis protocol was used twice daily for 4 days. The feasibility of the procedure, surgical duration, operative complications, and dialysis efficacy were evaluated. Postoperative pain and inflammation were graded (0–3).Results: The procedure was successfully performed in all dogs with a median operating time of 25 minutes. No operative complications occurred. Procedure‐related postoperative pain and inflammation were minimal. Eight consecutive PD procedures were successfully performed, and no leakage or obstruction was observed.Conclusions: Laparoscopic‐assisted partial omentectomy and omentopexy can be performed at the same time as PD catheter placement with minimal morbidity.
- 1 February 2013
- Published by Wiley in Veterinary Surgery
- Vol. 42 (5) , 579-585
Laparoscopic‐Assisted Placement of a Peritoneal Dialysis Catheter With Partial Omentectomy and Omentopexy in Dogs: An Experimental Study
Objective: To describe a technique of laparoscopic‐assisted placement of a peritoneal dialysis (PD) catheter with simultaneously performed partial omentectomy and omentopexy.Study Design: Pilot experimental study.Animals: Beagle dogs (n = 6).Methods: After placement of 1 sub‐umbilical laparoscope portal and 1 instrument portal in the left cranial abdominal quadrant, laparoscopic‐assisted partial omentectomy, and omentopexy were performed, and a modified Tenckhoff PD catheter was placed under laparoscopic guidance. A modified dialysis protocol was used twice daily for 4 days. The feasibility of the procedure, surgical duration, operative complications, and dialysis efficacy were evaluated. Postoperative pain and inflammation were graded (0–3).Results: The procedure was successfully performed in all dogs with a median operating time of 25 minutes. No operative complications occurred. Procedure‐related postoperative pain and inflammation were minimal. Eight consecutive PD procedures were successfully performed, and no leakage or obstruction was observed.Conclusions: Laparoscopic‐assisted partial omentectomy and omentopexy can be performed at the same time as PD catheter placement with minimal morbidity.
- 1 March 2012
- Published by Wiley in Veterinary Surgery
- Vol. 41 (3) , 362-366
Intercostal Insertion of Veress Needle for Canine Laparoscopic Procedures: A Cadaver Study
Objective: To record and compare the frequency of organ penetration after insertion of a Veress needle (VN) in 6 different intercostal spaces (ICS) for creation of pneumoperitoneum in canine cadavers.Study Design: Descriptive study.Animals: Canine cadavers (n = 15).Methods: In 15 cadavers positioned in dorsal recumbency,VNinsertion in the right and left 8th–10thICSwas performed, the abdomen insufflated, andVNposition and any visceral penetration recorded. The frequency of viscus penetration was assessed in all insertion sites.Results: In cadavers, the right 9thICSwas associated with the lowest number of organ penetrations afterVNinsertion.Conclusion: In cadavers, the position associated with the lowest frequency of penetrating any intraabdominal structure was the 9thICSon the right side.
- 1 March 2012
- Published by Wiley in Veterinary Surgery
- Vol. 41 (3) , 362-366
Intercostal Insertion of Veress Needle for Canine Laparoscopic Procedures: A Cadaver Study
Objective: To record and compare the frequency of organ penetration after insertion of a Veress needle (VN) in 6 different intercostal spaces (ICS) for creation of pneumoperitoneum in canine cadavers.Study Design: Descriptive study.Animals: Canine cadavers (n = 15).Methods: In 15 cadavers positioned in dorsal recumbency,VNinsertion in the right and left 8th–10thICSwas performed, the abdomen insufflated, andVNposition and any visceral penetration recorded. The frequency of viscus penetration was assessed in all insertion sites.Results: In cadavers, the right 9thICSwas associated with the lowest number of organ penetrations afterVNinsertion.Conclusion: In cadavers, the position associated with the lowest frequency of penetrating any intraabdominal structure was the 9thICSon the right side.
- 1 March 2012
- Published by Wiley in Veterinary Surgery
- Vol. 41 (3) , 367-373
Right Intercostal Insertion of aVeress Needle for Laparoscopy in Dogs
Objective: To evaluate right intercostalVeress needle (VN) insertion for laparoscopy in dogs.Study Design: Longitudinal cohort study.Animals: Female dogs (n = 56).Methods: TheVNwas inserted in the last palpable right intercostal space, either 1/3 (GroupT; 28 dogs) or mid distance (GroupH; 28 dogs) from the xiphoid cartilage to the most caudal extent of the costal arch. Problems encountered duringVNinsertion and injuries were recorded, graded, and compared between groups, and also between the first and last 20 insertions.Results: Pneumoperitoneum was successfully achieved byVNinsertion in 49 (88%) dogs after a single (45 dogs) or 2nd attempt (4 dogs). Frequency of complications was as follows: 20 grade 1 (subcutaneous emphysema, omentum, or falciform injuries); 6 grade 2 (liver or spleen injury), and 1 grade 3 complication (pneumothorax occurred). No significant difference was found between the 2 groups or between the first and last 20 dogs.Conclusions: Right intercostalVNinsertion facilitates pneumoperitoneum in dogs with few consequential complications. No significant difference was found between entry sites; however, the mid distance insertion site in the last palpable intercostal space with dog positioned in dorsal recumbency is likely to result in less complications.
- 1 March 2012
- Published by Wiley in Veterinary Surgery
- Vol. 41 (3) , 367-373
Right Intercostal Insertion of aVeress Needle for Laparoscopy in Dogs
Objective: To evaluate right intercostalVeress needle (VN) insertion for laparoscopy in dogs.Study Design: Longitudinal cohort study.Animals: Female dogs (n = 56).Methods: TheVNwas inserted in the last palpable right intercostal space, either 1/3 (GroupT; 28 dogs) or mid distance (GroupH; 28 dogs) from the xiphoid cartilage to the most caudal extent of the costal arch. Problems encountered duringVNinsertion and injuries were recorded, graded, and compared between groups, and also between the first and last 20 insertions.Results: Pneumoperitoneum was successfully achieved byVNinsertion in 49 (88%) dogs after a single (45 dogs) or 2nd attempt (4 dogs). Frequency of complications was as follows: 20 grade 1 (subcutaneous emphysema, omentum, or falciform injuries); 6 grade 2 (liver or spleen injury), and 1 grade 3 complication (pneumothorax occurred). No significant difference was found between the 2 groups or between the first and last 20 dogs.Conclusions: Right intercostalVNinsertion facilitates pneumoperitoneum in dogs with few consequential complications. No significant difference was found between entry sites; however, the mid distance insertion site in the last palpable intercostal space with dog positioned in dorsal recumbency is likely to result in less complications.
- 10 January 2012
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 14 (4) , 295-298
Omentalisation of the head in cats: A cadaver study
The involvement of the greater omentum in reconstructive, abdominal and thoracic surgery is based on its manifold qualities, which include immunological support, lymphatic drainage, angiogenesis, adhesion, haemostasis and fat storage. The purpose of this study was to determine whether the greater omentum could be extended to the head. In addition, we evaluated the surgical procedures necessary for this extension. Our study reveals that specific surgical lengthening techniques of the greater omentum, such as dorsal extension and inverted L-shape elongation, are necessary to successfully transpose the omentum to the head in cats. As the survival of the omentum after transposition procedures is still unknown, its application in chronic non-healing wounds of the head in cats warrants further investigation.
- 10 January 2012
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 14 (4) , 295-298
Omentalisation of the head in cats: A cadaver study
The involvement of the greater omentum in reconstructive, abdominal and thoracic surgery is based on its manifold qualities, which include immunological support, lymphatic drainage, angiogenesis, adhesion, haemostasis and fat storage. The purpose of this study was to determine whether the greater omentum could be extended to the head. In addition, we evaluated the surgical procedures necessary for this extension. Our study reveals that specific surgical lengthening techniques of the greater omentum, such as dorsal extension and inverted L-shape elongation, are necessary to successfully transpose the omentum to the head in cats. As the survival of the omentum after transposition procedures is still unknown, its application in chronic non-healing wounds of the head in cats warrants further investigation.