Bliss Kaneshiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bliss Kaneshiro has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Alison Edelman
Department of Obstetrics & Gynecology, Oregon Health & Science University, Portland, OR 97239, USA
4 shared publications- Jeffrey T. Jensen
Department of Obstetrics and Gynecology, Oregon Health and Science University, Portland, OR, United States
4 shared publications Mark Nichols
Department of Obstetrics & Gynecology, Oregon Health & Science University, Portland, OR 97239, USA
3 shared publications- Alison Edelman
Department of Obstetrics and Gynecology, Oregon Health & Science University, Portland, Oregon, USA
2 shared publications David A Grimes
University of North Carolina, School of Medicine; Obstetrics and Gynecology; CB#7570 Chapel Hill North Carolina USA 27599-7570
2 shared publicationsLaureen M Lopez
FHI 360; Clinical Sciences; P.O. Box 13950 Research Triangle Park North Carolina USA 27709
2 shared publications
Latest Publications
- 16 October 2012
- Published by Georg Thieme Verlag KG in Seminars in Reproductive Medicine
- Vol. 30 (06) , 459-464
Contraceptive Use and Sexual Behavior in Obese Women
Obesity and unintended pregnancy differentially affect women based on sociodemographic factors. Because of the overlap of these factors, obesity and unintended pregnancy have been described as colliding epidemics. Understanding the relationship between obesity and unintended pregnancy, contraceptive use, and sexual behavior is important in improving the reproductive health of women given the increasing weight demographic. A review of the literature reveals contraceptive use versus nonuse does not differ in women of different body weights. Obese women use oral contraceptives less than normal weight women and are more likely to use procedural methods like sterilization. No difference was noted in most types of sexual behavior for women of different body weights.
- 16 October 2012
- Published by Georg Thieme Verlag KG in Seminars in Reproductive Medicine
- Vol. 30 (06) , 459-464
Contraceptive Use and Sexual Behavior in Obese Women
Obesity and unintended pregnancy differentially affect women based on sociodemographic factors. Because of the overlap of these factors, obesity and unintended pregnancy have been described as colliding epidemics. Understanding the relationship between obesity and unintended pregnancy, contraceptive use, and sexual behavior is important in improving the reproductive health of women given the increasing weight demographic. A review of the literature reveals contraceptive use versus nonuse does not differ in women of different body weights. Obese women use oral contraceptives less than normal weight women and are more likely to use procedural methods like sterilization. No difference was noted in most types of sexual behavior for women of different body weights.
- 15 August 2012
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2012 (8) , CD009251
Pain management for tubal sterilization by hysteroscopy
Tubal sterilization by hysteroscopy involves inserting a foreign body in both fallopian tubes. Over a three-month period, the tubal lumen is occluded by tissue growth stimulated by the insert. Tubal sterilization by hysteroscopy has advantages over laparoscopy or mini-laparotomy, including the avoidance of abdominal incisions and the convenience of performing the procedure in an office-based setting. Pain, an important determinant of procedure acceptability, can be a concern when tubal sterilization is performed in the office. To review all randomized controlled trials that evaluated interventions to decrease pain during tubal sterilization by hysteroscopy. From January to March 2011, we searched the computerized databases of MEDLINE, POPLINE, CENTRAL, EMBASE, LILACS, and CINAHL for relevant trials. We searched for current trials via Clinicaltrials.gov. We also examined the reference lists of pertinent articles and wrote to known investigators for information about other published or unpublished trials. We included all randomized controlled trials that evaluated pain management at the time of sterilization by hysteroscopy. The intervention could be compared to another intervention or placebo. Initial data were extracted by one review author. A second review author verified all extracted data. Whenever possible, the analysis was conducted with all women randomized and in the original assigned groups. Data were analyzed using RevMan software. Pain was measured using either a 10-cm or 100-point visual analog scale (VAS). When pain was measured at multiple points during the procedure, the overall pain score was considered the primary treatment effect. If this was not measured, a summation of all pain scores for the procedure was considered to be the primary treatment effect. For continuous variables, the mean difference with 95% confidence interval was computed. Two trials met the inclusion criteria. The total number of participants was 167. Using a 10-cm VAS to measure pain, no significant difference emerged in overall pain for the entire procedure between women who received a paracervical block with lidocaine versus normal saline (mean difference -0.77; 95% CI -2.67 to 1.13). No significant difference in pain score was noted at the time of injection of study solution to the anterior lip of the cervix (mean difference -0.6; 95% CI -1.3 to 0.1), placement of the device in the tubal ostia (mean difference -0.60; 95% CI -1.8 to 0.7), and postprocedure pain (mean difference 0.2; 95% CI -0.8 to 1.2). Procedure time (mean difference -0.2 minutes; 95% CI -2.2 to 1.8 minutes) and successful bilateral placement (OR 1.0; 95% CI 0.19 to 5.28) was not significantly different between groups. During certain portions of the procedure, such as placement of the tenaculum (mean difference -2.03; 95% CI -2.88 to -1.18), administration of the paracervical block (mean difference -1.92; 95% CI -2.84 to -1.00), and passage of the hysteroscope through the external (mean difference -2.31; 95% CI -3.30 to -1.32) and internal os (mean difference -2.31; 95% CI -3.39 to -1.23), use of paracervical block with lidocaine resulted in lower pain scores.Using a 600-point scale calculated by adding 100-point VAS scores from six different portions of the procedure, no significant difference emerged in overall pain between women who received intravenous conscious sedation versus oral analgesia (mean difference -23.00; CI -62.02 to 16.02). Using a 100-point VAS, no significant difference emerged at the time of speculum insertion (mean difference 4.0; 95% CI -4.0 to 12.0), cervical injection of lidocaine (mean difference -1.8; 95% CI -10.0 to 6.4), insertion of the hysteroscope (mean difference -8.7; 95% CI -19.7 to 2.3), placement of the first device (mean difference -4.4; 95% CI -15.8 to 7.0), and removal of the hysteroscope (mean difference 0.9; 95% CI -3.9 to 5.7). Procedure time (mean difference -0.2 minutes; 95% CI -2.0 to 1.6 minutes) and time in the recovery area (mean difference 3.6 minutes; 95% CI -11.3 to 18.5 minutes) was not different between groups. However, women who received intravenous conscious sedation had lower pain scores at the time of insertion of the second tubal device compared to women who received oral analgesia (mean difference -12.60; CI -23.98 to -1.22). The available literature is insufficient to determine the appropriate analgesia or anesthesia for sterilization by hysteroscopy. Compared to paracervical block with normal saline, paracervical block with lidocaine reduced pain during some portions of the procedure. Intravenous sedation resulted in lower pain scores during insertion of the second tubal device. However, neither paracervical block with lidocaine nor conscious sedation significantly reduced overall pain scores for sterilization by hysteroscopy.
- 15 August 2012
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2012 (8) , CD009251
Pain management for tubal sterilization by hysteroscopy
Tubal sterilization by hysteroscopy involves inserting a foreign body in both fallopian tubes. Over a three-month period, the tubal lumen is occluded by tissue growth stimulated by the insert. Tubal sterilization by hysteroscopy has advantages over laparoscopy or mini-laparotomy, including the avoidance of abdominal incisions and the convenience of performing the procedure in an office-based setting. Pain, an important determinant of procedure acceptability, can be a concern when tubal sterilization is performed in the office. To review all randomized controlled trials that evaluated interventions to decrease pain during tubal sterilization by hysteroscopy. From January to March 2011, we searched the computerized databases of MEDLINE, POPLINE, CENTRAL, EMBASE, LILACS, and CINAHL for relevant trials. We searched for current trials via Clinicaltrials.gov. We also examined the reference lists of pertinent articles and wrote to known investigators for information about other published or unpublished trials. We included all randomized controlled trials that evaluated pain management at the time of sterilization by hysteroscopy. The intervention could be compared to another intervention or placebo. Initial data were extracted by one review author. A second review author verified all extracted data. Whenever possible, the analysis was conducted with all women randomized and in the original assigned groups. Data were analyzed using RevMan software. Pain was measured using either a 10-cm or 100-point visual analog scale (VAS). When pain was measured at multiple points during the procedure, the overall pain score was considered the primary treatment effect. If this was not measured, a summation of all pain scores for the procedure was considered to be the primary treatment effect. For continuous variables, the mean difference with 95% confidence interval was computed. Two trials met the inclusion criteria. The total number of participants was 167. Using a 10-cm VAS to measure pain, no significant difference emerged in overall pain for the entire procedure between women who received a paracervical block with lidocaine versus normal saline (mean difference -0.77; 95% CI -2.67 to 1.13). No significant difference in pain score was noted at the time of injection of study solution to the anterior lip of the cervix (mean difference -0.6; 95% CI -1.3 to 0.1), placement of the device in the tubal ostia (mean difference -0.60; 95% CI -1.8 to 0.7), and postprocedure pain (mean difference 0.2; 95% CI -0.8 to 1.2). Procedure time (mean difference -0.2 minutes; 95% CI -2.2 to 1.8 minutes) and successful bilateral placement (OR 1.0; 95% CI 0.19 to 5.28) was not significantly different between groups. During certain portions of the procedure, such as placement of the tenaculum (mean difference -2.03; 95% CI -2.88 to -1.18), administration of the paracervical block (mean difference -1.92; 95% CI -2.84 to -1.00), and passage of the hysteroscope through the external (mean difference -2.31; 95% CI -3.30 to -1.32) and internal os (mean difference -2.31; 95% CI -3.39 to -1.23), use of paracervical block with lidocaine resulted in lower pain scores.Using a 600-point scale calculated by adding 100-point VAS scores from six different portions of the procedure, no significant difference emerged in overall pain between women who received intravenous conscious sedation versus oral analgesia (mean difference -23.00; CI -62.02 to 16.02). Using a 100-point VAS, no significant difference emerged at the time of speculum insertion (mean difference 4.0; 95% CI -4.0 to 12.0), cervical injection of lidocaine (mean difference -1.8; 95% CI -10.0 to 6.4), insertion of the hysteroscope (mean difference -8.7; 95% CI -19.7 to 2.3), placement of the first device (mean difference -4.4; 95% CI -15.8 to 7.0), and removal of the hysteroscope (mean difference 0.9; 95% CI -3.9 to 5.7). Procedure time (mean difference -0.2 minutes; 95% CI -2.0 to 1.6 minutes) and time in the recovery area (mean difference 3.6 minutes; 95% CI -11.3 to 18.5 minutes) was not different between groups. However, women who received intravenous conscious sedation had lower pain scores at the time of insertion of the second tubal device compared to women who received oral analgesia (mean difference -12.60; CI -23.98 to -1.22). The available literature is insufficient to determine the appropriate analgesia or anesthesia for sterilization by hysteroscopy. Compared to paracervical block with normal saline, paracervical block with lidocaine reduced pain during some portions of the procedure. Intravenous sedation resulted in lower pain scores during insertion of the second tubal device. However, neither paracervical block with lidocaine nor conscious sedation significantly reduced overall pain scores for sterilization by hysteroscopy.
- 1 April 2012
- Published by Elsevier in Contraception
- Vol. 85 (4) , 351-358
A randomized controlled trial of subantimicrobial-dose doxycycline to prevent unscheduled bleeding with continuous oral contraceptive pill use
- 1 April 2012
- Published by Elsevier in Contraception
- Vol. 85 (4) , 351-358
A randomized controlled trial of subantimicrobial-dose doxycycline to prevent unscheduled bleeding with continuous oral contraceptive pill use
- 1 October 2011
- Published by Wolters Kluwer Health in Current Opinion in Obstetrics and Gynecology
- Vol. 23 (5) , 344-349
Contraceptive considerations in overweight teens
The purpose of this review is to explore the efficacy and safety of contraceptives in overweight adolescents. There are few studies exploring hormonal contraceptive efficacy and safety in overweight and obese adults and almost none addressing these issues in adolescents. Luckily for teens, in terms of safety, many of the comorbidities associated with obesity are yet to transpire and their options for contraception remain relatively unrestricted. Studies of the combined oral contraceptive pill and patch in adults suggest that efficacy may be decreased in overweight adolescents. There is no evidence to suggest that the efficacy of the contraceptive implant or intrauterine device (IUD) is decreased in overweight adolescents. Indeed, these long-acting reversible methods will be the best choice for many adolescents because of their high efficacy. Although the literature is not definitive, there is probably a subset of adolescents who are susceptible to weight gain with use of depot medroxyprogesterone acetate. Although there is little research regarding contraceptive efficacy in overweight adolescents, IUDs and implants will be the best methods for many adolescents because of their high efficacy, reversibility, and safety.
- 1 October 2011
- Published by Wolters Kluwer Health in Current Opinion in Obstetrics and Gynecology
- Vol. 23 (5) , 344-349
Contraceptive considerations in overweight teens
The purpose of this review is to explore the efficacy and safety of contraceptives in overweight adolescents. There are few studies exploring hormonal contraceptive efficacy and safety in overweight and obese adults and almost none addressing these issues in adolescents. Luckily for teens, in terms of safety, many of the comorbidities associated with obesity are yet to transpire and their options for contraception remain relatively unrestricted. Studies of the combined oral contraceptive pill and patch in adults suggest that efficacy may be decreased in overweight adolescents. There is no evidence to suggest that the efficacy of the contraceptive implant or intrauterine device (IUD) is decreased in overweight adolescents. Indeed, these long-acting reversible methods will be the best choice for many adolescents because of their high efficacy. Although the literature is not definitive, there is probably a subset of adolescents who are susceptible to weight gain with use of depot medroxyprogesterone acetate. Although there is little research regarding contraceptive efficacy in overweight adolescents, IUDs and implants will be the best methods for many adolescents because of their high efficacy, reversibility, and safety.
- 1 August 2011
- Vol. 70 (8) , 168-71
The challenges of collecting data on race and ethnicity in a diverse, multiethnic state.
Race and ethnicity are commonly used predictor variables in medical and public health research. Including these variables has helped researchers to describe the etiology of certain disease states. Including race and ethnicity in research has been hypothesis generating in terms of the relationship between genetic and environmental factors in the development of disease. Eliminating health disparities among different racial and ethnic groups has become a national priority. However, incorporating race and ethnicity into health research is complex because these variables are difficult to define and individuals often identify with more than one race or ethnicity. As a "minority-majority", multiethnic, multiracial state, Hawai'i faces unique challenges in incorporating race and ethnicity into research. As the demographics of the United States continue to evolve, many of the challenges faced in Hawai'i will apply to the United States as a whole.
- 1 August 2011
- Vol. 70 (8) , 168-71
The challenges of collecting data on race and ethnicity in a diverse, multiethnic state.
Race and ethnicity are commonly used predictor variables in medical and public health research. Including these variables has helped researchers to describe the etiology of certain disease states. Including race and ethnicity in research has been hypothesis generating in terms of the relationship between genetic and environmental factors in the development of disease. Eliminating health disparities among different racial and ethnic groups has become a national priority. However, incorporating race and ethnicity into health research is complex because these variables are difficult to define and individuals often identify with more than one race or ethnicity. As a "minority-majority", multiethnic, multiracial state, Hawai'i faces unique challenges in incorporating race and ethnicity into research. As the demographics of the United States continue to evolve, many of the challenges faced in Hawai'i will apply to the United States as a whole.
- 1 May 2011
- Published by Elsevier in Contraception
- Vol. 83 (5) , 431-435
Blood loss at the time of first-trimester surgical abortion in anticoagulated women
- 1 May 2011
- Published by Elsevier in Contraception
- Vol. 83 (5) , 431-435
Blood loss at the time of first-trimester surgical abortion in anticoagulated women
- 1 March 2011
- Published by Elsevier in Contraception
- Vol. 83 (3) , 194-201
Expanding medical abortion: can medical abortion be effectively provided without the routine use of ultrasound?
- 1 March 2011
- Published by Elsevier in Contraception
- Vol. 83 (3) , 194-201
Expanding medical abortion: can medical abortion be effectively provided without the routine use of ultrasound?
- Open Access
- 1 July 2010
- Published by Taylor & Francis in International Journal of Women's Health
- Vol. 2, 211-220
Long-term safety, efficacy, and patient acceptability of the intrauterine Copper T-380A contraceptive device
The intrauterine device (IUD), primarily in the form of the copper IUD, is used by more than 150 million women around the world, making it the most widely used reversible method of contraception. With a remarkably low failure rate of less than 1 per 100 women in the first year of use, the Copper T-380A is in the top tier of contraceptives in terms of efficacy. Risks of utilization include perforation and an increased risk of infection in the first 20 days following insertion. Overall, the number of adverse events is low, making the Copper T-380A a very safe contraceptive method. The most common reasons for the discontinuation of this method are menstrual bleeding and dysmenorrhea. However, cumulative discontinuation rates of Copper T-380A are lower than that have been reported for other methods, indicating that the Copper T-380A is highly acceptable to women. After 5 years, approximately 50% of all women, who have a Copper T-380A inserted, will continue to use this highly effective contraceptive method.
- 1 July 2010
- Published by Taylor & Francis in International Journal of Women's Health
- Vol. 2, 211-220
Open AccessLong-term safety, efficacy, and patient acceptability of the intrauterine Copper T-380A contraceptive device
The intrauterine device (IUD), primarily in the form of the copper IUD, is used by more than 150 million women around the world, making it the most widely used reversible method of contraception. With a remarkably low failure rate of less than 1 per 100 women in the first year of use, the Copper T-380A is in the top tier of contraceptives in terms of efficacy. Risks of utilization include perforation and an increased risk of infection in the first 20 days following insertion. Overall, the number of adverse events is low, making the Copper T-380A a very safe contraceptive method. The most common reasons for the discontinuation of this method are menstrual bleeding and dysmenorrhea. However, cumulative discontinuation rates of Copper T-380A are lower than that have been reported for other methods, indicating that the Copper T-380A is highly acceptable to women. After 5 years, approximately 50% of all women, who have a Copper T-380A inserted, will continue to use this highly effective contraceptive method.
- 1 June 2010
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 115 (6) , 1141-1149
Treatment of Unscheduled Bleeding in Continuous Oral Contraceptive Users With Doxycycline
To estimate whether doxycycline, a matrix metalloproteinase inhibitor, would decrease unscheduled bleeding associated with initiation of a continuous oral contraceptive pill. Participants initiating a continuous oral contraceptive pill (20 micrograms of ethinyl estradiol/90 micrograms of levonorgestrel) were randomly assigned to receive either doxycycline (100 mg orally twice daily) or placebo taken for 5 days at the onset of each bleeding or spotting episode during the first 84 days of the study period. For the final 28 days of the study, participants were observed on the oral contraceptive pill alone. The primary outcome was the number of bleeding and spotting days. A sample size of 66 (33 in each arm) was calculated to detect a 50% reduction in bleeding (beta=0.80, alpha=0.05) and accounted for a 30% dropout rate. Sixty-six women were randomly assinged (33 in each study group). There were no significant differences during the 84-day treatment in bleeding or spotting days (doxycycline [mean {standard error}, placebo, P=.32) or the length of the longest bleeding or spotting episode (doxycycline, placebo, P=.70) between study groups. Similarly, no significant differences in bleeding patterns existed between groups during the final 28 days. Doxycycline, administered once bleeding has started, does not decrease unscheduled bleeding or shorten episodes of unscheduled bleeding in continuous oral contraceptive pill users. I.
- 1 June 2010
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 115 (6) , 1141-1149
Treatment of Unscheduled Bleeding in Continuous Oral Contraceptive Users With Doxycycline
To estimate whether doxycycline, a matrix metalloproteinase inhibitor, would decrease unscheduled bleeding associated with initiation of a continuous oral contraceptive pill. Participants initiating a continuous oral contraceptive pill (20 micrograms of ethinyl estradiol/90 micrograms of levonorgestrel) were randomly assigned to receive either doxycycline (100 mg orally twice daily) or placebo taken for 5 days at the onset of each bleeding or spotting episode during the first 84 days of the study period. For the final 28 days of the study, participants were observed on the oral contraceptive pill alone. The primary outcome was the number of bleeding and spotting days. A sample size of 66 (33 in each arm) was calculated to detect a 50% reduction in bleeding (beta=0.80, alpha=0.05) and accounted for a 30% dropout rate. Sixty-six women were randomly assinged (33 in each study group). There were no significant differences during the 84-day treatment in bleeding or spotting days (doxycycline [mean {standard error}, placebo, P=.32) or the length of the longest bleeding or spotting episode (doxycycline, placebo, P=.70) between study groups. Similarly, no significant differences in bleeding patterns existed between groups during the final 28 days. Doxycycline, administered once bleeding has started, does not decrease unscheduled bleeding or shorten episodes of unscheduled bleeding in continuous oral contraceptive pill users. I.