Luis A. Gaitini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Luis A. Gaitini has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Sonia J. Vaida
Director, Obstetric Anesthesia Unit
5 shared publicationsBoris Yanovski
Senior Anesthesiologist, Department of Anesthesiology, Bnai-Zion Medical Center, Haifa, Israel
4 shared publicationsBruce Ben-David
Clinical Associate Professor, Department of Anesthesiology, University of Pittsburgh Medical Centers, Pittsburgh, Pennsylvania
4 shared publicationsMostafa Somri
Director, Pediatric Anesthesia Unit
4 shared publications- Carin A. Hagberg
The University of Texas MD Anderson Cancer Center
2 shared publications Edmond Sabo
Senior Anesthesiologist, Department of Anesthesiology, B’nai Zion Medical Center
2 shared publications
Latest Publications
- 1 August 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 101 (2) , 316-320
A Randomized Controlled Trial Comparing the ProSeal™ Laryngeal Mask Airway with the Laryngeal Tube Suction in Mechanically Ventilated Patients
Background: The ProSeal Laryngeal Mask Airway (PLMA) (Laryngeal Mask Company, Henley-on-Thames, United Kingdom) is a new laryngeal mask with a modified cuff designed to improve its seal and a drain tube for gastric tube placement. Similarly, the Laryngeal Tube Suction (LTS) (VBM Medizintechnik Gmbh, Sulz a.N, Germany) is a new laryngeal tube that also has an additional channel for gastric tube placement. This study compared the placement and functions of these two devices. Methods: One hundred fifty patients undergoing general anesthesia for elective surgery were randomly allocated to the PLMA (n = 75) or LTS (n = 75). Oxygenation and ventilation, ease of insertion, fiberoptic view, oropharyngeal leak pressure, ventilatory data, ease of gastric tube insertion, and postoperative airway morbidity were determined. Results: After successful insertion of the devices in 96% of patients with the PLMA and in 94.4% with the LTS it was possible to maintain oxygenation, ventilation, and respiratory mechanics during the entire duration of surgery. Successful first and second attempt insertion rates were 57 patients (76%) and 15 patients (20%), respectively, for the PLMA and 60 patients (80%) and 11 patients (14.6%), respectively, for the LTS. Airway placement was unsuccessful with the PLMA in three patients and with the LTS in four patients. Time to achieve an effective airway was 36 +/- 24 s with the PLMA versus 34 +/- 25 s with the LTS. Gastric tube insertion was possible in 97.3% of patients with the PLMA and in 96% with the LTS. Conclusions: With respect to both physiologic and clinical function, the PLMA and LTS are similar and either device can be used to establish a safe and effective airway in mechanically ventilated anesthetized adult patients.
- 1 August 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 101 (2) , 316-320
A Randomized Controlled Trial Comparing the ProSeal™ Laryngeal Mask Airway with the Laryngeal Tube Suction in Mechanically Ventilated Patients
Background: The ProSeal Laryngeal Mask Airway (PLMA) (Laryngeal Mask Company, Henley-on-Thames, United Kingdom) is a new laryngeal mask with a modified cuff designed to improve its seal and a drain tube for gastric tube placement. Similarly, the Laryngeal Tube Suction (LTS) (VBM Medizintechnik Gmbh, Sulz a.N, Germany) is a new laryngeal tube that also has an additional channel for gastric tube placement. This study compared the placement and functions of these two devices. Methods: One hundred fifty patients undergoing general anesthesia for elective surgery were randomly allocated to the PLMA (n = 75) or LTS (n = 75). Oxygenation and ventilation, ease of insertion, fiberoptic view, oropharyngeal leak pressure, ventilatory data, ease of gastric tube insertion, and postoperative airway morbidity were determined. Results: After successful insertion of the devices in 96% of patients with the PLMA and in 94.4% with the LTS it was possible to maintain oxygenation, ventilation, and respiratory mechanics during the entire duration of surgery. Successful first and second attempt insertion rates were 57 patients (76%) and 15 patients (20%), respectively, for the PLMA and 60 patients (80%) and 11 patients (14.6%), respectively, for the LTS. Airway placement was unsuccessful with the PLMA in three patients and with the LTS in four patients. Time to achieve an effective airway was 36 +/- 24 s with the PLMA versus 34 +/- 25 s with the LTS. Gastric tube insertion was possible in 97.3% of patients with the PLMA and in 96% with the LTS. Conclusions: With respect to both physiologic and clinical function, the PLMA and LTS are similar and either device can be used to establish a safe and effective airway in mechanically ventilated anesthetized adult patients.
- 1 June 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (6) , 1750-1755
An Evaluation of the Laryngeal Tube?? During General Anesthesia Using Mechanical Ventilation
The Laryngeal Tube® is a new supraglottic ventilatory device for airway management. It has been developed to secure a patent airway during either spontaneous or mechanical ventilation. In this study, we sought to determine the effectiveness of the Laryngeal Tube for primary airway management during
- 1 June 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (6) , 1750-1755
An Evaluation of the Laryngeal Tube?? During General Anesthesia Using Mechanical Ventilation
The Laryngeal Tube® is a new supraglottic ventilatory device for airway management. It has been developed to secure a patent airway during either spontaneous or mechanical ventilation. In this study, we sought to determine the effectiveness of the Laryngeal Tube for primary airway management during
- 1 December 2002
- Published by Elsevier in Anesthesiology Clinics of North America
- Vol. 20 (4) , 893-906
The Esophageal-Tracheal Combitube
- 1 December 2002
- Published by Elsevier in Anesthesiology Clinics of North America
- Vol. 20 (4) , 893-906
The Esophageal-Tracheal Combitube
- 1 January 2002
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 126 (1) , 87-88
The Intubating Laryngeal Mask
- 1 January 2002
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 126 (1) , 87-88
The Intubating Laryngeal Mask
- Open Access
- 1 January 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 94 (1) , 79-82
The Combitube in Elective Surgery
Background: The Combitube has proved to be a valuable device for securing the airway in cases of difficult intubation. This study investigated the effectiveness of the Combitube in elective surgery during both mechanical and spontaneous ventilation. Methods: Two hundred patients classified as American Society of Anesthesiologists physical status I and II, with normal airways, scheduled for elective surgery were randomly allocated into two groups: nonparalyzed, spontaneously breathing (n = 100); or paralyzed, mechanically ventilated (n = 100). After induction of general anesthesia and insertion of the Combitube, oxygen saturation, end-tidal carbon dioxide and isoflurane concentration, systolic and diastolic blood pressure and heart rate, as well as breath-by-breath spirometry data were obtained every 5 min. Results: In 97% of patients, it was possible to maintain oxygenation, ventilation, and respiratory mechanics, as well as hemodynamic stability during either mechanical or spontaneous ventilation for the entire duration of surgery. The duration of surgery was between 15 and 155 min. Conclusions: The results of this study suggest that the Combitube is an effective and safe airway device for continued management of the airway in 97% of elective surgery cases.
- 1 January 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 94 (1) , 79-82
Open AccessThe Combitube in Elective Surgery
Background: The Combitube has proved to be a valuable device for securing the airway in cases of difficult intubation. This study investigated the effectiveness of the Combitube in elective surgery during both mechanical and spontaneous ventilation. Methods: Two hundred patients classified as American Society of Anesthesiologists physical status I and II, with normal airways, scheduled for elective surgery were randomly allocated into two groups: nonparalyzed, spontaneously breathing (n = 100); or paralyzed, mechanically ventilated (n = 100). After induction of general anesthesia and insertion of the Combitube, oxygen saturation, end-tidal carbon dioxide and isoflurane concentration, systolic and diastolic blood pressure and heart rate, as well as breath-by-breath spirometry data were obtained every 5 min. Results: In 97% of patients, it was possible to maintain oxygenation, ventilation, and respiratory mechanics, as well as hemodynamic stability during either mechanical or spontaneous ventilation for the entire duration of surgery. The duration of surgery was between 15 and 155 min. Conclusions: The results of this study suggest that the Combitube is an effective and safe airway device for continued management of the airway in 97% of elective surgery cases.
- 1 July 2000
- Published by Wolters Kluwer Health in Journal for Healthcare Quality
- Vol. 22 (4) , 4-9
Using Rate-Based Events to Improve Clinical Practice
This article describes the implementation and utilization of a continuous quality improvement (CQI) program in the identification, analysis, and correction of a rate-based event in anesthesia, in this case, intraoperative hypertension. A CQI program was implemented based on voluntary, handwritten, anonymous reports of intraoperative and postanesthesia care unit events. This CQI program detected a high incidence of intraoperative hypertension, indicated major causal factors, suggested a set of corrective measures, and allowed for measurement of their efficacy.
- 1 July 2000
- Published by Wolters Kluwer Health in Journal for Healthcare Quality
- Vol. 22 (4) , 4-9
Using Rate-Based Events to Improve Clinical Practice
This article describes the implementation and utilization of a continuous quality improvement (CQI) program in the identification, analysis, and correction of a rate-based event in anesthesia, in this case, intraoperative hypertension. A CQI program was implemented based on voluntary, handwritten, anonymous reports of intraoperative and postanesthesia care unit events. This CQI program detected a high incidence of intraoperative hypertension, indicated major causal factors, suggested a set of corrective measures, and allowed for measurement of their efficacy.
- 1 May 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 90 (5) , 1029-1033
Does the Addition of Fentanyl to Bupivacaine in Caudal Epidural Block Have an Effect on the Plasma Level of Catecholamines in Children?
We evaluated the effect of adding fentanyl to bupivacaine, compared with bupivacaine alone, on the stress response. The effect was evaluated by determining blood levels of epinephrine (E) and norepinephrine (NE) in pediatric patients receiving caudal epidural blocks. Sixty children, 1–8 yr of age, scheduled for elective herniorrhaphy, were randomly allocated to two groups of 30 patients each. Group A received inhaled anesthesia and caudal epidural block with bupivacaine 0.25% alone, 1.0 mL/kg. Group B received identical anesthesia; however, fentanyl 1 μg/kg was added to the bupivacaine in the caudal block. Blood samples for E and NE plasma levels were drawn at induction time (H0), at the end of surgery (H1), and in the postanesthesia care unit (H2). In both groups, there was a significant decrease in the E and NE plasma levels, when comparing H1 and H2 with H0 within the same group (P < 0.001). There were no significant differences in the E and NE plasma levels between the two groups at H0, H1, and H2 (P = 0.5, P = 0.12, P = 0.5, respectively). Pain scores (modified Children’s Hospital of Eastern Ontario Pain Score) were also similar in both groups (P = 0.19). This study suggests that adding fentanyl 1 μg/kg to bupivacaine in the caudal epidural block in children does not influence plasma levels of E and NE, nor does it improve the analgesic intensity of the caudal block. This study demonstrates that adding fentanyl to bupivacaine for caudal epidural blocks has no beneficial effect on the stress response in pediatric patients undergoing inguinal herniorrhaphy, as evaluated by plasma epinephrine and norepinephrine values, compared with bupivacaine alone.
- 1 May 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 90 (5) , 1029-1033
Does the Addition of Fentanyl to Bupivacaine in Caudal Epidural Block Have an Effect on the Plasma Level of Catecholamines in Children?
We evaluated the effect of adding fentanyl to bupivacaine, compared with bupivacaine alone, on the stress response. The effect was evaluated by determining blood levels of epinephrine (E) and norepinephrine (NE) in pediatric patients receiving caudal epidural blocks. Sixty children, 1–8 yr of age, scheduled for elective herniorrhaphy, were randomly allocated to two groups of 30 patients each. Group A received inhaled anesthesia and caudal epidural block with bupivacaine 0.25% alone, 1.0 mL/kg. Group B received identical anesthesia; however, fentanyl 1 μg/kg was added to the bupivacaine in the caudal block. Blood samples for E and NE plasma levels were drawn at induction time (H0), at the end of surgery (H1), and in the postanesthesia care unit (H2). In both groups, there was a significant decrease in the E and NE plasma levels, when comparing H1 and H2 with H0 within the same group (P < 0.001). There were no significant differences in the E and NE plasma levels between the two groups at H0, H1, and H2 (P = 0.5, P = 0.12, P = 0.5, respectively). Pain scores (modified Children’s Hospital of Eastern Ontario Pain Score) were also similar in both groups (P = 0.19). This study suggests that adding fentanyl 1 μg/kg to bupivacaine in the caudal epidural block in children does not influence plasma levels of E and NE, nor does it improve the analgesic intensity of the caudal block. This study demonstrates that adding fentanyl to bupivacaine for caudal epidural blocks has no beneficial effect on the stress response in pediatric patients undergoing inguinal herniorrhaphy, as evaluated by plasma epinephrine and norepinephrine values, compared with bupivacaine alone.
- 1 January 1999
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 88 (1) , 193-196
Fiberoptic-Guided Airway Exchange of the Esophageal-Tracheal Combitube[registered sign] in Spontaneously Breathing Versus Mechanically Ventilated Patients
The aim of this study was to compare fiberoptic-guided airway exchange of the esophageal-tracheal Combitube (ETC, Kendall-Sheridan Catheter Corp., Argyle, NY) with an endotracheal tube in spontaneously breathing versus mechanically ventilated patients. Forty patients with Mallampati score III and IV scheduled for elective surgery were randomly allocated into two groups (n = 20 each): nonparalyzed, spontaneously breathing or paralyzed, mechanically ventilated patients. After anesthetic induction and insertion of the ETC, a fiberoptic bronchoscope threaded into an armored endotracheal tube was passed transnasally into the larynx. Endotracheal intubation was successful in 18 spontaneously breathing patients and in 15 patients during controlled ventilation. Successful airway exchange was completed in significantly less time (P < 0.05) in spontaneously breathing patients (9+/-3 min; mean +/- SD) than in mechanically ventilated patients (13+/-4 min). Both methods allowed for continuous airway control and maintenance of ventilation and oxygenation. The described method is a means of replacing the ETC with an endotracheal tube without interruption of airway control or ventilation. Replacing the ETC with an endotracheal tube using this method is more readily accomplished during spontaneous ventilation than during controlled ventilation. We describe the replacement of the Combitube by an endotracheal tube by the aid of fiberoptic bronchoscopy and without interruption of airway control or ventilation. The performance of this technique was facilitated by spontaneous ventilation compared with mechanical ventilation.
- 1 January 1999
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 88 (1) , 193-196
Fiberoptic-Guided Airway Exchange of the Esophageal-Tracheal Combitube[registered sign] in Spontaneously Breathing Versus Mechanically Ventilated Patients
The aim of this study was to compare fiberoptic-guided airway exchange of the esophageal-tracheal Combitube (ETC, Kendall-Sheridan Catheter Corp., Argyle, NY) with an endotracheal tube in spontaneously breathing versus mechanically ventilated patients. Forty patients with Mallampati score III and IV scheduled for elective surgery were randomly allocated into two groups (n = 20 each): nonparalyzed, spontaneously breathing or paralyzed, mechanically ventilated patients. After anesthetic induction and insertion of the ETC, a fiberoptic bronchoscope threaded into an armored endotracheal tube was passed transnasally into the larynx. Endotracheal intubation was successful in 18 spontaneously breathing patients and in 15 patients during controlled ventilation. Successful airway exchange was completed in significantly less time (P < 0.05) in spontaneously breathing patients (9+/-3 min; mean +/- SD) than in mechanically ventilated patients (13+/-4 min). Both methods allowed for continuous airway control and maintenance of ventilation and oxygenation. The described method is a means of replacing the ETC with an endotracheal tube without interruption of airway control or ventilation. Replacing the ETC with an endotracheal tube using this method is more readily accomplished during spontaneous ventilation than during controlled ventilation. We describe the replacement of the Combitube by an endotracheal tube by the aid of fiberoptic bronchoscopy and without interruption of airway control or ventilation. The performance of this technique was facilitated by spontaneous ventilation compared with mechanical ventilation.