JGJérôme Genest

Jérôme Genest

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jérôme Genest has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Phase-Dependent Squeezing in Dual-Comb Interferometry

    by Daniel I. Herman, Molly Kate Kreider, Noah Lordi, Mathieu Walsh, Eugene J. Tsao, Alexander J. Lind, Matthew Heyrich, Joshua Combes, Scott A. Diddams, Jérôme Genest

    Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

  • Open Access

    Phase-Dependent Squeezing in Dual-Comb Interferometry

    by Daniel I. Herman, Molly Kate Kreider, Noah Lordi, Mathieu Walsh, Eugene J. Tsao, Alexander J. Lind, Matthew Heyrich, Joshua Combes, Scott A. Diddams, Jerome Genest

    We measure phase-dependent Kerr soliton squeezing and anti-squeezing in the time-domain dualcomb interferograms generated using two independent frequency comb lasers. The signal appears as non-stationary quantum noise that varies with the fringe phase of the interferogram and dips below the shot-noise level by as much as 3.8 dB for alternating zero-crossings. The behavior arises from the periodic displacement of the Kerr squeezed comb by the coherent field of the second frequency comb, and is confirmed by a quantum noise model. These experiments support a route towards quantum-enhanced dual-comb timing applications and raise the prospect of high-speed quantum state tomography with dual-comb interferometry.

  • Top Cited Papers

    Squeezed dual-comb spectroscopy

    by Daniel I. Herman, Mathieu Walsh, Molly Kate Kreider, Noah Lordi, Eugene J. Tsao, Alexander J. Lind, Matthew Heyrich, Joshua Combes, Jérôme Genest, Scott A. Diddams

    Optical frequency combs have enabled distinct advantages in broadband, high-resolution spectroscopy and precision interferometry. However, quantum mechanics ultimately limits the metrological precision achievable with laser frequency combs. Quantum squeezing has led to substantial measurement improvements with continuous wave lasers, but experiments demonstrating metrological advantage with squeezed combs are less developed. Using the Kerr effect in nonlinear optical fiber, a 1-gigahertz frequency comb centered at 1560 nanometers is amplitude-squeezed by >3 decibels (dB) over a 2.5-terahertz bandwidth. Dual-comb interferometry yields mode-resolved spectroscopy of hydrogen sulfide gas with a signal-to-noise ratio nearly 3 dB beyond the shot-noise limit. The quantum noise reduction leads to a twofold quantum speedup in the determination of gas concentration, with implications for high-speed measurements of multiple species in dynamic chemical environments.


  • Finding and minimizing systematic errors in dual-comb spectroscopy

    by M Walsh, P Guay, J D Deschênes, N Malarich, I Coddington, K Cossel, J Genest

    With sufficiently high signal-to-noise, several systematic errors become prominent in dual-comb interferometry measurements. This paper reviews several error sources including electrical, photo-detection, amplification and acquisition chain non-linearity. Sources of optical non-linearity such as self-phase modulation, cross-phase modulation and Raman soliton shifting are also covered, as are spectral fringing due to parasitic reflections and back-scattering. The non-linear response of the target sample itself can also be a source of errors. Methods to identify and minimize errors in experimental data are discussed. Good practices, instrument design strategies and tools, such as the dynamic range diagram, are suggested.


  • Mode-resolved optical frequency comb fixed point localization via dual-comb interferometry

    by Daniel I. Herman, Mathieu Walsh, Jérôme Genest

    We describe improved methods for locating the fixed point of an optical frequency comb. Two continuous-wave lasers are locked to a reference frequency comb and track the optical phase of a second comb-under-test (CUT) at two points separated by approximately 1.6 THz. Carrier-envelope and optical phase tracking (OPT) yields a precise fixed point measurement across a range of pump modulation frequencies (400 Hz–250 kHz). Sub-nanometer shifts of the fixed point are observed. The fixed point is also determined with high precision using dual-comb interferometry (DCI), and the value closely matches the calculation from the dual-point tracking method.


  • Graphics card-based real-time processing for dual comb interferometry

    by Mathieu Walsh, James Kasic, Kevin Cossel, Jérôme Genest

    The technique of performing interferometry with two optical frequency combs is used by an increasing number of research groups and even for field deployed commercial applications. Real-time interferogram acquisition, correction, and averaging are, however, still not broadly accessible. This limits the deployment and wider adoption of this high resolution, high sensitivity technique. We herein introduce and describe a freely available correction software performing real-time processing on a graphics processing unit.


  • Pulse interaction induced systematic errors in dual comb spectroscopy

    by Mathieu Walsh, Esther Baumann, Nathan Malarich, Scott Egbert, Ryan K. Cole, Gregory B. Rieker, Nathan R. Newbury, Ian Coddington, Kevin Cossel, Jérôme Genest

    Systematic errors are observed in dual comb spectroscopy when pulses from the two sources travel in a common fiber before interrogating the sample of interest. When sounding a molecular gas, these errors distort both the line shapes and retrieved concentrations. Simulations of dual comb interferograms based on a generalized nonlinear Schrodinger equation highlight two processes for these systematic errors. Self-phase modulation changes the spectral content of the field interrogating the molecular response but affects the recorded spectral baseline and absorption features differently, leading to line intensity errors. Cross-phase modulation modifies the relative inter-pulse delay, thus introducing interferogram sampling errors and creating a characteristic asymmetric distortion on spectral lines. Simulations capture the shape and amplitude of experimental errors which are around 0.1% on spectral transmittance residuals for 10 mW of total average power in 10 meters of common fiber, scaling up to above 0.6% for 20 mW and 60 m.


  • Fast rate dual-comb spectrometer in the water-transparent 7.5–11.5 µm region

    by Luca Moretti, Mathieu Walsh, Nawaf Abualsaud, Davide Gatti, Marco Lamperti, Jérome Genest, Aamir Farooq, Marco Marangoni

    We introduce a dual-comb spectrometer based on erbium fiber oscillators at 250 MHz that operates in the 7.5–11.5 µm spectral range over optical bandwidths up to 9 THz with a multi-kHz acquisition rate. Over an observation bandwidth of 0.8 THz, the signal-to-noise ratio per spectral point reaches 168 Hz0.5 at an acquisition rate of 26 kHz, which allows the investigation of transient processes in the gas phase at high temporal resolution. The system also represents an attractive solution for multi-species atmospheric gas detection in open paths due to the water transparency of the spectral window, the use of thermo-electrically cooled detectors, and the out-of-loop phase correction of the interferograms.


  • Chasing systematic errors in dual comb spectroscopy

    by Jérôme Genest, Mathieu Walsh, Ian Coddington, Nathan Malarich, Kevin Cossel

    Dual comb spectroscopy is currently limited by systematic errors, at the ~1% level in spectral transmittance. Understanding and mitigating these errors is essential for greenhouse gases quantification as well as for improving spectroscopic databases.


  • Open Access

    Millimetric spatial resolution time-expanded ϕ-OTDR

    by Miguel Soriano-Amat, Philippe Guay, Hugo F. Martins, Sonia Martin-Lopez, Miguel Gonzalez-Herraez, María R. Fernández-Ruiz, Jerome Genest

    Time-expanded phase-sensitive optical time-domain reflectometry is a distributed optical fiber sensing technology based on dual-frequency combs that allows for dynamic and high spatial resolution measurements while maintaining reduced detection requirements. Since the formalization of the technique, different experimental schemes have been satisfactorily tested, with a general performance of cm-scale spatial resolution over hundreds of meters. In this article, we present an optimized scheme with enhanced energy and spectral efficiencies that allows reaching 5 mm spatial resolution. As compared to previous experimental approaches, the presented architecture is based on a free-running dual comb setup generated through pure electro-optical phase modulation. Besides, the introduction of an optical hybrid in the detection stage allows for doubling the spatial resolution while keeping the refresh rate and the sensing range unchanged.