Masatoshi Kajita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Masatoshi Kajita has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Minori Abe
Hiroshima University
4 shared publications Masahiko Hada
3 shared publications- Naoki Kimura
National Institute for Fusion Science
3 shared publications Geetha Gopakumar
2 shared publications- Geetha Gopakumar
Department of Chemistry Tokyo Metropolitan University 1--1 Minami--Osawa 192-- 0397 Hachioji Tokyo Japan
2 shared publications A. V. Avdeenkov
Institute of Physics and Power Engineering
1 shared publication
Latest Publications
- 15 June 2021
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 90 (6)
Prospect for Precision Measurement of the Yb2+ 1S0–\(^{3}\text{P}_{0}^{o}\) Transition FrequencyWe discuss prospects of precision measurement of the Yb2+ 4f14 1S0–4f13 5d \(^{3}\text{P}_{0}^{o}\) transition frequency (1.4 × 1015 Hz). Attainable uncertainty of this precision measurement is the...- 15 June 2021
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 90 (6)
Prospect for Precision Measurement of the Yb2+ 1S0–\(^{3}\text{P}_{0}^{o}\) Transition FrequencyWe discuss prospects of precision measurement of the Yb2+ 4f14 1S0–4f13 5d \(^{3}\text{P}_{0}^{o}\) transition frequency (1.4 × 1015 Hz). Attainable uncertainty of this precision measurement is the...- 15 April 2021
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 90 (4) , 044302
Detection of Nuclear Spin of 14N2+ Molecular Ion
The Q(0) branch for molecular ions of N2+ with I = 0 (I: nuclear spin) brings advantages if measurements having uncertainties of 10−18 order are desired. The molecular N2+ ions are prepared in the N = 0 state (N: rotational state) by resonance enhanced multi-photon ionization. For molecular 14N2+ ions with N = 0, I is either 0 or 2 having an abundance ratio of \(1:5\) (for 15N2+, I = 0 only occurs). A frequency measurement method is proposed whereby the molecular ions with I = 0 are selected using a blue sideband Raman transition to neighboring substates. This transition is suppressed for the state N = I = 0.- 15 April 2021
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 90 (4) , 044302
Detection of Nuclear Spin of 14N2+ Molecular Ion
The Q(0) branch for molecular ions of N2+ with I = 0 (I: nuclear spin) brings advantages if measurements having uncertainties of 10−18 order are desired. The molecular N2+ ions are prepared in the N = 0 state (N: rotational state) by resonance enhanced multi-photon ionization. For molecular 14N2+ ions with N = 0, I is either 0 or 2 having an abundance ratio of \(1:5\) (for 15N2+, I = 0 only occurs). A frequency measurement method is proposed whereby the molecular ions with I = 0 are selected using a blue sideband Raman transition to neighboring substates. This transition is suppressed for the state N = I = 0.- 15 November 2020
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 89 (11)
Prospect for Vibrational Transition Frequency Measurement of Rare-gas Hydride Ions
A method of precise measurement of the \(X^{1}\Sigma (v,J,F) = (0,0,1/2) - (1,1,1/2)\) transitions in HeH+ (89.1 THz), NeH+ (81.3 THz), and ArH+ (77.1 THz) molecular ions is proposed. These E1-allowed transitions are useful for locking the frequencies of infrared lasers because they are free from electric-quadrupole shifts. The DC Stark and Zeeman shifts are suppressed to below 10−16. The molecular ions are prepared in the \((0,0,1/2)\) state using a cryogenic chamber without optical pumping. Measurements with low systematic uncertainty using a small number of molecular ions is possible by quantum logical spectroscopic detection of the \((0,2,3/2)\) state to which molecular ions are pumped by the clock laser.- 15 November 2020
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 89 (11)
Prospect for Vibrational Transition Frequency Measurement of Rare-gas Hydride Ions
A method of precise measurement of the \(X^{1}\Sigma (v,J,F) = (0,0,1/2) - (1,1,1/2)\) transitions in HeH+ (89.1 THz), NeH+ (81.3 THz), and ArH+ (77.1 THz) molecular ions is proposed. These E1-allowed transitions are useful for locking the frequencies of infrared lasers because they are free from electric-quadrupole shifts. The DC Stark and Zeeman shifts are suppressed to below 10−16. The molecular ions are prepared in the \((0,0,1/2)\) state using a cryogenic chamber without optical pumping. Measurements with low systematic uncertainty using a small number of molecular ions is possible by quantum logical spectroscopic detection of the \((0,2,3/2)\) state to which molecular ions are pumped by the clock laser.- 2 June 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (13) , 135401
Prospects in rare-gas hydride ions for terahertz frequency standards
A proposal is given to use the X 1 Σ v , J , F = ( 0 , 0 , 1 / 2 ) − ( 0 , 1 , 1 / 2 ) transition of the HeH + (2.0 THz), NeH + (1.0 THz), and ArH + (0.62 THz) molecular ions as novel frequency standards in the terahertz region. This transition is free from the electric-quadrupole shift, and the DC Stark and Zeeman shifts are much less than those of the CaH + and MgH + molecular ions. These transitions are useful for locking the frequencies of oscillators like quantum cascade lasers (QCL) or resonant tunnel diodes (RTD) with uncertainties of 10 −15 .
- 2 June 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (13) , 135401
Prospects in rare-gas hydride ions for terahertz frequency standards
A proposal is given to use the X 1 Σ v , J , F = ( 0 , 0 , 1 / 2 ) − ( 0 , 1 , 1 / 2 ) transition of the HeH + (2.0 THz), NeH + (1.0 THz), and ArH + (0.62 THz) molecular ions as novel frequency standards in the terahertz region. This transition is free from the electric-quadrupole shift, and the DC Stark and Zeeman shifts are much less than those of the CaH + and MgH + molecular ions. These transitions are useful for locking the frequencies of oscillators like quantum cascade lasers (QCL) or resonant tunnel diodes (RTD) with uncertainties of 10 −15 .
- 18 March 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (8) , 085401
Attainable accuracies of QH + rotational transition frequencies (Q: 40 Ca, 24 Mg, 202 Hg)
Molecular rotational transition frequencies are useful as frequency standard in the terahertz region. The X 1 Σ ( J , F ) = ( 0 , 1 / 2 ) → ( 1 , 1 / 2 ) transition frequencies of QH + molecular ions (Q: an even isotope of Group II element) in a linear trap are useful as measurement uncertainties are low. An uncertainty given by the Stark and Zeeman shifts can be below 10 −15 using 202 HgH + molecular ion.
- 18 March 2020
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 53 (8) , 085401
Attainable accuracies of QH + rotational transition frequencies (Q: 40 Ca, 24 Mg, 202 Hg)
Molecular rotational transition frequencies are useful as frequency standard in the terahertz region. The X 1 Σ ( J , F ) = ( 0 , 1 / 2 ) → ( 1 , 1 / 2 ) transition frequencies of QH + molecular ions (Q: an even isotope of Group II element) in a linear trap are useful as measurement uncertainties are low. An uncertainty given by the Stark and Zeeman shifts can be below 10 −15 using 202 HgH + molecular ion.
- 15 October 2019
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 88 (10)
Estimation of Blackbody Zeeman Shift in 1S0–3P0 Transition Frequencies
The blackbody radiation Zeeman (BBRZ) shift in the 1S0–3P0 transition frequencies of 87Sr and 171Yb atoms and an 115In+ ion was theoretically estimated with the temperature of the surroundings betw...
- 15 October 2019
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 88 (10)
Estimation of Blackbody Zeeman Shift in 1S0–3P0 Transition Frequencies
The blackbody radiation Zeeman (BBRZ) shift in the 1S0–3P0 transition frequencies of 87Sr and 171Yb atoms and an 115In+ ion was theoretically estimated with the temperature of the surroundings betw...
- 15 July 2018
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 87 (7)
Non-destructive Monitoring of Molecular Vibrational Transitions
Transition frequency measurement by monitoring a phase shift requires no cycling transition and appears to be applicable to molecular vibrational transitions. We estimated the attainable signal-to-noise ratio SNR, and found that this method can be used to observe the one-photon E1 transition of more than 100 molecules. This method can also be used to observe the two-photon transition of more than 104 molecules in an optical lattice. This method is likely to be particularly useful for observing the \((v,N,J,F) = (0,1,1/2,0) \to (1,1,1/2,0)\) transition frequency of CaF molecules.- 15 July 2018
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 87 (7)
Non-destructive Monitoring of Molecular Vibrational Transitions
Transition frequency measurement by monitoring a phase shift requires no cycling transition and appears to be applicable to molecular vibrational transitions. We estimated the attainable signal-to-noise ratio SNR, and found that this method can be used to observe the one-photon E1 transition of more than 100 molecules. This method can also be used to observe the two-photon transition of more than 104 molecules in an optical lattice. This method is likely to be particularly useful for observing the \((v,N,J,F) = (0,1,1/2,0) \to (1,1,1/2,0)\) transition frequency of CaF molecules.- 15 December 2017
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 86 (12)
Search for the Variation in (mp/me) Using Two Vibrational Transition Frequencies of Molecular Ions
We propose a method to search for the variation in the proton-to-electron mass ratio μ = (mp/me) based on the precise measurement of Q(v′) = [f(v′) − f(2v′)/2]/f(v′), where f(v′) is the 16O2+ \(X^{2}\Pi _{1/2}(v,J) = (0,1/2) \to (v',1/2)\) transition frequency. Q(v′) is proportional to μ−1/2, and it can be measured with an uncertainty of 10−18. This method is also applicable to other molecular transition frequencies (i) J = 0 → 0 or 1/2 → 1/2 transition, (ii) transition between stretched states, and (iii) the same sign for the light shift induced by the clock lasers in f(v′) and f(2v′).- 15 December 2017
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 86 (12)
Search for the Variation in (mp/me) Using Two Vibrational Transition Frequencies of Molecular Ions
We propose a method to search for the variation in the proton-to-electron mass ratio μ = (mp/me) based on the precise measurement of Q(v′) = [f(v′) − f(2v′)/2]/f(v′), where f(v′) is the 16O2+ \(X^{2}\Pi _{1/2}(v,J) = (0,1/2) \to (v',1/2)\) transition frequency. Q(v′) is proportional to μ−1/2, and it can be measured with an uncertainty of 10−18. This method is also applicable to other molecular transition frequencies (i) J = 0 → 0 or 1/2 → 1/2 transition, (ii) transition between stretched states, and (iii) the same sign for the light shift induced by the clock lasers in f(v′) and f(2v′).- 22 February 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 95 (2) , 023418
Accuracy estimation of the transition frequencies targeting the search for the variation in the proton-electron mass ratioWe estimate the Stark and Zeeman shifts in the transition frequencies of the molecular ion as a step in the search for the variation in the proton-to-electron mass ratio . The or the transition frequencies (THz region) of the molecular ion have particularly high sensitivity to the variation in . Note also that the Stark shift in the transition frequencies is expected to be much smaller than that for heteronuclear diatomic molecules. However, the actual systematic uncertainties for the transition frequencies have never been estimated. We estimated the Stark and Zeeman shifts in the different transition frequencies. When the molecular ions in a string crystal formed in a linear trap (trap electric field V/cm, and Stark shift ) are used, the transition frequencies are most advantageous for the search for the variation in because the Zeeman shift is easily suppressed to lower than and the electric quadrupole shift is zero. On the other hand, the transition frequency has another merit in that the positive Stark shift induced by the trap electric field can be canceled by the quadratic Doppler shift. Therefore, the measurement using molecular ions in a Coulomb crystal broadened in the radial direction is also possible, when the Zeeman shift is effectively eliminated.- 22 February 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 95 (2) , 023418
Accuracy estimation of the transition frequencies targeting the search for the variation in the proton-electron mass ratioWe estimate the Stark and Zeeman shifts in the transition frequencies of the molecular ion as a step in the search for the variation in the proton-to-electron mass ratio . The or the transition frequencies (THz region) of the molecular ion have particularly high sensitivity to the variation in . Note also that the Stark shift in the transition frequencies is expected to be much smaller than that for heteronuclear diatomic molecules. However, the actual systematic uncertainties for the transition frequencies have never been estimated. We estimated the Stark and Zeeman shifts in the different transition frequencies. When the molecular ions in a string crystal formed in a linear trap (trap electric field V/cm, and Stark shift ) are used, the transition frequencies are most advantageous for the search for the variation in because the Zeeman shift is easily suppressed to lower than and the electric quadrupole shift is zero. On the other hand, the transition frequency has another merit in that the positive Stark shift induced by the trap electric field can be canceled by the quadratic Doppler shift. Therefore, the measurement using molecular ions in a Coulomb crystal broadened in the radial direction is also possible, when the Zeeman shift is effectively eliminated.- Open Access
Accuracy estimation of the 16O2+ transition frequencies targeting the search for the variation in mp/me
The precise measurement of molecular vibrational transition frequencies is useful in the search for variation in the proton-to-electron mass ratio {\mu}. Homonuclear diatomic molecules are particularly advantageous for precise measurement because of the small Stark shift. This paper discusses the Stark and Zeeman shifts in the 16O2+ vibrational transition frequencies.To search for the variation {\mu}(1)in transition frequencies are much more advantageous than the transition frequencies between the X2{\Pi}1/2 v=21 and a4{\Pi}1/2 v=0 states, whose sensitivity to the variation in {\mu} is high because of the accidental degeneracy.
Open AccessAccuracy estimation of the 16O2+ transition frequencies targeting the search for the variation in mp/me
The precise measurement of molecular vibrational transition frequencies is useful in the search for variation in the proton-to-electron mass ratio {\mu}. Homonuclear diatomic molecules are particularly advantageous for precise measurement because of the small Stark shift. This paper discusses the Stark and Zeeman shifts in the 16O2+ vibrational transition frequencies.To search for the variation {\mu}(1)in transition frequencies are much more advantageous than the transition frequencies between the X2{\Pi}1/2 v=21 and a4{\Pi}1/2 v=0 states, whose sensitivity to the variation in {\mu} is high because of the accidental degeneracy.