Joris E. N Jaspers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joris E. N Jaspers has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
B. A. M. J. de Mol
Academic Medical Center (AMC)
1 shared publicationC. A. Grimbergen
Academic Medical Center (AMC)
1 shared publicationC.A. Grimbergen
1 shared publicationCornelis A Grimbergen
1 shared publicationJ. Diks
Department of Surgery, VU Medical Center, Amsterdam, The Netherlands
1 shared publication- Justus Laurens Herder
Delft University of Technology
1 shared publication
Latest Publications
- Open Access
- 6 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 1025-1031
The mechanical master–slave manipulator: an instrument improving the performance in standardized tasks for endoscopic surgery
This study aimed to evaluate the feasibility and efficacy of a mechanical minimally invasive manipulator for endoscopic surgery. In contrast to currently available motorized master–slave manipulators, this mechanical manipulator consists of two purely mechanical, hand-controlled endoscopic arms with joints that allow seven degrees of freedom (DOF). For the study, 30 medical students performed four different tasks in a pelvic trainer box using either two conventional endoscopic needleholders or a set of mechanical manipulators. The exercise consisted of four different tasks: repositioning of coins, rope passing, passing of a suture through rings, and tying of a surgical knot. All experiments were recorded on videotape (S-VHS), and the data were analyzed afterwards by an independent observer using a quantitative time-action analysis. A significant difference in the number of total actions (including failures) favoring the mechanical manipulator group was shown in most exercises. A significant difference in failures per task was shown in favor of the mechanical manipulator group as well. There was no significant difference shown in the total time per exercise. The tasks clearly demonstrated the efficacy of the mechanical manipulator, although some technical flaws emerged during the experiments. Considering the fact that a first prototype of the mechanical manipulator was tested, modifications are to be expected in a next model. These experiments show the potential of the mechanical manipulator, and it is expected to be a competitive and economical instrument for endoscopic surgery in the near future.
- 6 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 1025-1031
Open AccessThe mechanical master–slave manipulator: an instrument improving the performance in standardized tasks for endoscopic surgery
This study aimed to evaluate the feasibility and efficacy of a mechanical minimally invasive manipulator for endoscopic surgery. In contrast to currently available motorized master–slave manipulators, this mechanical manipulator consists of two purely mechanical, hand-controlled endoscopic arms with joints that allow seven degrees of freedom (DOF). For the study, 30 medical students performed four different tasks in a pelvic trainer box using either two conventional endoscopic needleholders or a set of mechanical manipulators. The exercise consisted of four different tasks: repositioning of coins, rope passing, passing of a suture through rings, and tying of a surgical knot. All experiments were recorded on videotape (S-VHS), and the data were analyzed afterwards by an independent observer using a quantitative time-action analysis. A significant difference in the number of total actions (including failures) favoring the mechanical manipulator group was shown in most exercises. A significant difference in failures per task was shown in favor of the mechanical manipulator group as well. There was no significant difference shown in the total time per exercise. The tasks clearly demonstrated the efficacy of the mechanical manipulator, although some technical flaws emerged during the experiments. Considering the fact that a first prototype of the mechanical manipulator was tested, modifications are to be expected in a next model. These experiments show the potential of the mechanical manipulator, and it is expected to be a competitive and economical instrument for endoscopic surgery in the near future.
- 1 June 2004
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 14 (3) , 145-152
Camera and Instrument Holders and Their Clinical Value in Minimally Invasive Surgery
During minimally invasive procedures an assistant is controlling the laparoscope. Ideally, the surgeon should be able to manipulate all instruments including the camera him/herself, to avoid communication problems and disturbing camera movements. Camera holders return camera-control to the surgeon and stabilize the laparoscopic image. An additional holder can be used to stabilize an extra laparoscopic instrument for retracting. A literature survey has been carried out giving an overview of the existing “robotic” and passive camera and instrument holders and, if available, results of their clinical value. Benefits and limitations were identified. Most studies showed that camera holders, passive and active, provide the surgeon with a more stable image and enables them to control their own view direction. Only the passive holders were suitable for holding instruments. Comparisons between different systems are reviewed. Both active and passive camera and instrument holders are functional, and may be helpful to perform solo-surgery. The benefits of active holders are questionable in relation to the performance of the much simpler passive designs.
- 1 June 2004
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 14 (3) , 145-152
Camera and Instrument Holders and Their Clinical Value in Minimally Invasive Surgery
During minimally invasive procedures an assistant is controlling the laparoscope. Ideally, the surgeon should be able to manipulate all instruments including the camera him/herself, to avoid communication problems and disturbing camera movements. Camera holders return camera-control to the surgeon and stabilize the laparoscopic image. An additional holder can be used to stabilize an extra laparoscopic instrument for retracting. A literature survey has been carried out giving an overview of the existing “robotic” and passive camera and instrument holders and, if available, results of their clinical value. Benefits and limitations were identified. Most studies showed that camera holders, passive and active, provide the surgeon with a more stable image and enables them to control their own view direction. Only the passive holders were suitable for holding instruments. Comparisons between different systems are reviewed. Both active and passive camera and instrument holders are functional, and may be helpful to perform solo-surgery. The benefits of active holders are questionable in relation to the performance of the much simpler passive designs.
- 1 December 2000
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 10 (6) , 331-335
Design and Feasibility of PASSIST, a Passive Instrument Positioner
Background and Purpose: During minimally invasive procedures, an assistant controls the camera and often a laparoscopic grasper. Ideally, the surgeon should be able to manipulate the instruments because the indirect way of control complicates the surgeon's observation and actions and disturbs eye-hand coordination. Reported replacements for the assistant are active positioners, "robots," such as the Aesop™ and the EndoAssist™. Because positioning instruments is often a static task, the Academic Medical Center has developed a passive assistant for instrument positioning (PASSIST) to allow solo surgery. Methods: The PASSIST was designed to be simple, fully autoclavable, slender, and stiff. The joints have adjustable friction and spring compensation for stabilizing the instrument in a fixed position, enabling intuitive single-hand repositioning. Results: The PASSIST has been tested in three laparoscopic procedures: cholecystectomy, laparoscopically assisted vaginal hysterectomy, and spondylodesis. I...
- 1 December 2000
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 10 (6) , 331-335
Design and Feasibility of PASSIST, a Passive Instrument Positioner
Background and Purpose: During minimally invasive procedures, an assistant controls the camera and often a laparoscopic grasper. Ideally, the surgeon should be able to manipulate the instruments because the indirect way of control complicates the surgeon's observation and actions and disturbs eye-hand coordination. Reported replacements for the assistant are active positioners, "robots," such as the Aesop™ and the EndoAssist™. Because positioning instruments is often a static task, the Academic Medical Center has developed a passive assistant for instrument positioning (PASSIST) to allow solo surgery. Methods: The PASSIST was designed to be simple, fully autoclavable, slender, and stiff. The joints have adjustable friction and spring compensation for stabilizing the instrument in a fixed position, enabling intuitive single-hand repositioning. Results: The PASSIST has been tested in three laparoscopic procedures: cholecystectomy, laparoscopically assisted vaginal hysterectomy, and spondylodesis. I...