Keisuke Miwa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Keisuke Miwa has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Kazuo Shirouzu
7 shared publicationsShinzo Takamori
6 shared publicationsAkihiro Hayashi
4 shared publicationsMari Fukunaga
3 shared publicationsMasahiro Mitsuoka
3 shared publications- Akihiro Hayashi
Department of Surgery, Kurume University School of Medicine, Fukuoka, Japan
2 shared publications
Latest Publications
- 7 December 2007
- Vol. 92 (4) , 192-4
Experimental study of Composix mesh for ventral hernia.
We aimed to compare conventional single-layer mesh and composite mesh in terms of the degree of tissue repair on the abdominal wall side of the mesh and the degree of mechanical adhesion to the intestine and to confirm the stability of composite mesh. We used a single-layer polypropylene (PP) mesh and a two-layer Composix mesh (E/X type) consisting of a PP mesh and an expanded polytetrafluoroethylene mesh. Twenty rats were divided into two groups. Three months after mesh placement, histopathologically, ingrowth of granulation tissue into the mesh on the abdominal wall side was prominent without mesh shrinkage or shift in either group. In the PP mesh group, 50% of the rats had firm adhesions between the mesh and the intestine, whereas the Composix mesh group had no adhesions to the intestine. Unlike conventional PP mesh, Composix mesh prevented adhesions to the intestine on the peritoneal side without impairing tissue union with the visceral peritoneum, suggesting its usefulness in clinical onlay mesh repair for ventral defects.
- 7 December 2007
- Vol. 92 (4) , 192-4
Experimental study of Composix mesh for ventral hernia.
We aimed to compare conventional single-layer mesh and composite mesh in terms of the degree of tissue repair on the abdominal wall side of the mesh and the degree of mechanical adhesion to the intestine and to confirm the stability of composite mesh. We used a single-layer polypropylene (PP) mesh and a two-layer Composix mesh (E/X type) consisting of a PP mesh and an expanded polytetrafluoroethylene mesh. Twenty rats were divided into two groups. Three months after mesh placement, histopathologically, ingrowth of granulation tissue into the mesh on the abdominal wall side was prominent without mesh shrinkage or shift in either group. In the PP mesh group, 50% of the rats had firm adhesions between the mesh and the intestine, whereas the Composix mesh group had no adhesions to the intestine. Unlike conventional PP mesh, Composix mesh prevented adhesions to the intestine on the peritoneal side without impairing tissue union with the visceral peritoneum, suggesting its usefulness in clinical onlay mesh repair for ventral defects.
- 1 December 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 78 (6) , 2188-2190
Fixation of Silicone Stents in the Subglottic Trachea: Preventing Stent Migration Using a Fixation Apparatus
- 1 December 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 78 (6) , 2188-2190
Fixation of Silicone Stents in the Subglottic Trachea: Preventing Stent Migration Using a Fixation Apparatus
- 1 December 2003
- Published by S. Karger AG in Respiration
- Vol. 70 (6) , 623-630
Continuous Monitoring of Oxygen Consumption in Patients Undergoing Weaning from Mechanical Ventilation
Background: The extubation or discontinuation of mechanical ventilatory support (MVS) is only the final step in the weaning process, and an improvement in the efficiency of the weaning process is required for more successful extubation or discontinuation of MVS. Objective: To evaluate whether continuous monitoring of oxygen consumption (v̇O2) using the metabolic gas monitor is a useful predictor of failure to tolerate a weaning trial of reduced MVS. Method: Twenty adult patients meeting the criteria for weaning, who required MVS ≧7 days and who were previously deemed to have failed weaning by their attending physicians. A weaning trial was defined as a 30-min period during the strengthening training of our standardized weaning protocol. The average v̇O2, respiratory rate (RR), tidal volume (TV), minute ventilation (v̇E) and energy expenditure (EE) were recorded in respiratory muscles for a stable period of 20 min at rest and for the last 5 min of the trial. Subsequently, the oxygen cost of breathing (OCOB), the ratio of respiratory frequency to tidal volume (f/VT), ΔRR, ΔTV, Δv̇E, and ΔEE were calculated. Results: Two hundred and eight weaning trials, including 145 successful trials and 63 failed trials from 20 patients were evaluated. In nonparametric analysis, a statistical difference in OCOB, ΔRR, and ΔEE was found between successful and failed weaning trials, while no statistical differences were found for the other parameters. An OCOB <30% was the most accurate predictor of outcome of a weaning trial, and an f/VT <105 was the least accurate. In a multiple logistic analysis, the OCOB revealed the highest odds ratio among all parameters. Conclusions: Measuring the OCOB was clinically beneficial in avoiding the induction of an excessive movement load on the respiratory muscles. In patients treated with MVS, continuous monitoring of v̇O2 is a useful to predict success or failure of trials attempting to reduce MVS.
- 1 December 2003
- Published by S. Karger AG in Respiration
- Vol. 70 (6) , 623-630
Continuous Monitoring of Oxygen Consumption in Patients Undergoing Weaning from Mechanical Ventilation
Background: The extubation or discontinuation of mechanical ventilatory support (MVS) is only the final step in the weaning process, and an improvement in the efficiency of the weaning process is required for more successful extubation or discontinuation of MVS. Objective: To evaluate whether continuous monitoring of oxygen consumption (v̇O2) using the metabolic gas monitor is a useful predictor of failure to tolerate a weaning trial of reduced MVS. Method: Twenty adult patients meeting the criteria for weaning, who required MVS ≧7 days and who were previously deemed to have failed weaning by their attending physicians. A weaning trial was defined as a 30-min period during the strengthening training of our standardized weaning protocol. The average v̇O2, respiratory rate (RR), tidal volume (TV), minute ventilation (v̇E) and energy expenditure (EE) were recorded in respiratory muscles for a stable period of 20 min at rest and for the last 5 min of the trial. Subsequently, the oxygen cost of breathing (OCOB), the ratio of respiratory frequency to tidal volume (f/VT), ΔRR, ΔTV, Δv̇E, and ΔEE were calculated. Results: Two hundred and eight weaning trials, including 145 successful trials and 63 failed trials from 20 patients were evaluated. In nonparametric analysis, a statistical difference in OCOB, ΔRR, and ΔEE was found between successful and failed weaning trials, while no statistical differences were found for the other parameters. An OCOB <30% was the most accurate predictor of outcome of a weaning trial, and an f/VT <105 was the least accurate. In a multiple logistic analysis, the OCOB revealed the highest odds ratio among all parameters. Conclusions: Measuring the OCOB was clinically beneficial in avoiding the induction of an excessive movement load on the respiratory muscles. In patients treated with MVS, continuous monitoring of v̇O2 is a useful to predict success or failure of trials attempting to reduce MVS.
- 1 June 2002
- Vol. 8 (3) , 154-9
The UPAO test in preoperative evaluation for major pulmonary resection: an operative case with markedly improved ventilatory function after radical pulmonary resection for lung cancer associated with pulmonary emphysema.
A 65-year-old man was admitted to our hospital for treatment of a squamous cell carcinoma in his right lung. Respiratory function testing showed an extremely reduced forced expiratory volume in 1 second (FEV1) of 1.0 l (29.9% of predicted), and a reduced FEV1/FVC ratio of 24.1%. Arterial blood gases on room air showed a pH of 7.41, a PaCO(2) of 36.7 mmHg, and a PaO(2) of 79.3 mmHg. To assess the predictive postoperative cardiopulmonary function, unilateral pulmonary artery occlusion (UPAO) testing was performed. In the condition of right main PA occlusion, the mean pulmonary artery pressure (mPAP), cardiac index (CI) and total pulmonary vessel resistance index (TPVRI) was 18 mmHg, 3.2 l/min/m(2) and 443.37 dyne.sec.cm(-5)/m(2), respectively. He underwent a middle lobectomy with combined partial resection of both the upper and lower lobes. He also underwent simultaneous resection of a giant bulla arising from the right upper lobe as lung volume reduction surgery. At 80 days after the operation, his FEV1 rose to 1.88 l, and the PaO(2) on room air was improved to 88.9 mmHg. UPAO testing was suggested to be more useful than routine pulmonary function test to determine the accurate predictive postoperative cardiopulmonary function and to decide indication for a radical operation.
- 1 June 2002
- Vol. 8 (3) , 154-9
The UPAO test in preoperative evaluation for major pulmonary resection: an operative case with markedly improved ventilatory function after radical pulmonary resection for lung cancer associated with pulmonary emphysema.
A 65-year-old man was admitted to our hospital for treatment of a squamous cell carcinoma in his right lung. Respiratory function testing showed an extremely reduced forced expiratory volume in 1 second (FEV1) of 1.0 l (29.9% of predicted), and a reduced FEV1/FVC ratio of 24.1%. Arterial blood gases on room air showed a pH of 7.41, a PaCO(2) of 36.7 mmHg, and a PaO(2) of 79.3 mmHg. To assess the predictive postoperative cardiopulmonary function, unilateral pulmonary artery occlusion (UPAO) testing was performed. In the condition of right main PA occlusion, the mean pulmonary artery pressure (mPAP), cardiac index (CI) and total pulmonary vessel resistance index (TPVRI) was 18 mmHg, 3.2 l/min/m(2) and 443.37 dyne.sec.cm(-5)/m(2), respectively. He underwent a middle lobectomy with combined partial resection of both the upper and lower lobes. He also underwent simultaneous resection of a giant bulla arising from the right upper lobe as lung volume reduction surgery. At 80 days after the operation, his FEV1 rose to 1.88 l, and the PaO(2) on room air was improved to 88.9 mmHg. UPAO testing was suggested to be more useful than routine pulmonary function test to determine the accurate predictive postoperative cardiopulmonary function and to decide indication for a radical operation.
- Open Access
- 1 January 2002
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 32 (1) , 27-29
Temporary Stenting for Malignant Tracheal Stenosis due to Esophageal Cancer: a Case Report
We present a case of a 56-year-old male with esophageal cancer who underwent successful temporary tracheal stenting followed by a surgical procedure. The trachea was obstructed owing to endotracheal metastasis and the patient had severe dyspnea. A silicone Y-stent was initially inserted into the tracheal stenosis to secure the airway, and then tumor-specific chemo-radiotherapy was applied. The tumor was reduced, the stent was removed and a pathological study indicated that the tracheal metastasis had disappeared. The patient then underwent esophagectomy and tumor-specific chemo-radiotherapy was continued after the surgery. The patient has remained alive and free of esophageal cancer for 18 months after the airway stent emplacement. These findings suggested that the silicone stent was suitable as a temporary measure and that temporary stenting combined with tumor-specific therapy was effective as part of the aggressive therapeutic strategy with which to treat the malignant airway stenosis due to esophageal cancer.
- 1 January 2002
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 32 (1) , 27-29
Open AccessTemporary Stenting for Malignant Tracheal Stenosis due to Esophageal Cancer: a Case Report
We present a case of a 56-year-old male with esophageal cancer who underwent successful temporary tracheal stenting followed by a surgical procedure. The trachea was obstructed owing to endotracheal metastasis and the patient had severe dyspnea. A silicone Y-stent was initially inserted into the tracheal stenosis to secure the airway, and then tumor-specific chemo-radiotherapy was applied. The tumor was reduced, the stent was removed and a pathological study indicated that the tracheal metastasis had disappeared. The patient then underwent esophagectomy and tumor-specific chemo-radiotherapy was continued after the surgery. The patient has remained alive and free of esophageal cancer for 18 months after the airway stent emplacement. These findings suggested that the silicone stent was suitable as a temporary measure and that temporary stenting combined with tumor-specific therapy was effective as part of the aggressive therapeutic strategy with which to treat the malignant airway stenosis due to esophageal cancer.
- 1 January 2002
- Published by Kurume Medical Journal in The Kurume Medical Journal
- Vol. 49 (1/2) , 67-69
Minute Lung Carcinoma Associated with Focal Honeycombed Lesion.
We report a case of minute lung carcinoma that developed in a focal honeycombed lesion in the right lung. A 70-year-old man presented hemosputum, and a cytological examination result was at class IV. A right lower lobectomy of the lung was performed. Microscopically, the thickened alveolar wall revealed tumor cells indicating a minute carcinoma, and showed squamous hyperplasia, metaplasia, and dysplasia, with the carcinoma in the distal airway epithelium. This peripheral lung carcinoma in a focal honeycombed lesion demonstrated the various stages of multistep carcinogenesis, which is recognized in hilar type squamous cell carcinoma. To date, the association between a honeycombed lesion and lung cancer has been poorly described. Here we have presented clear evidence of the association of this carcinoma with the honeycombed lesion.
- 1 January 2002
- Published by Kurume Medical Journal in The Kurume Medical Journal
- Vol. 49 (1/2) , 67-69
Minute Lung Carcinoma Associated with Focal Honeycombed Lesion.
We report a case of minute lung carcinoma that developed in a focal honeycombed lesion in the right lung. A 70-year-old man presented hemosputum, and a cytological examination result was at class IV. A right lower lobectomy of the lung was performed. Microscopically, the thickened alveolar wall revealed tumor cells indicating a minute carcinoma, and showed squamous hyperplasia, metaplasia, and dysplasia, with the carcinoma in the distal airway epithelium. This peripheral lung carcinoma in a focal honeycombed lesion demonstrated the various stages of multistep carcinogenesis, which is recognized in hilar type squamous cell carcinoma. To date, the association between a honeycombed lesion and lung cancer has been poorly described. Here we have presented clear evidence of the association of this carcinoma with the honeycombed lesion.