Praveen Kumar Neema
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Praveen Kumar Neema has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Ramesh Chandra Rathod
15 shared publicationsPrabhat Kumar Sinha
Sree Chitra Tirunal Institute for Medical Sciences and Technology, Kerala, India
7 shared publicationsManikandan Sethuraman
6 shared publications- Praveen Kerala Varma
Department of Cardio-Thoracic Surgery, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, India
5 shared publications Sethuraman Manikandan
4 shared publicationsArun Vijayakumar
2 shared publications
Latest Publications
- Open Access
- 1 January 2009
- Published by Medknow in Annals of Cardiac Anaesthesia
- Vol. 12 (1) , 53-6
Superior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications
Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt) is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.
- 1 January 2009
- Published by Medknow in Annals of Cardiac Anaesthesia
- Vol. 12 (1) , 53-6
Open AccessSuperior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications
Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt) is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.
- 13 December 2008
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (6) , 445-447
Mainstream Time-Capnography: An Aid to Select an Appropriate Uncuffed Endotracheal Tube in Small Children
Uncuffed endotracheal tubes are commonly used in children in an attempt to decrease the potential for pressure induced tracheal injury. However, uncuffed endotracheal tube may increase the risk of aspiration and lead to erratic delivery of preset tidal volume during mechanical ventilation. Therefore, it is desirable to intubate trachea with an appropriate but not an oversized endotracheal tube. In children, for selecting an endotracheal tube, a variety of formulas and techniques are used to find the endotracheal tube size that minimizes both pressure induced tracheal injury and aspiration potential or variable ventilation. Air-leak following tracheal intubation can be recognized by the presence of audible leak, by auscultation over the trachea, by palpation over the trachea and by observing effects of positive end-expiratory pressure on inspiratory expiratory tidal volume difference during mechanical ventilation. We describe mainstream time-capnograph as an aid to recognize leak around the endotracheal tube and its utility to determine appropriate endotracheal tube size in small children.
- 13 December 2008
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 22 (6) , 445-447
Mainstream Time-Capnography: An Aid to Select an Appropriate Uncuffed Endotracheal Tube in Small Children
Uncuffed endotracheal tubes are commonly used in children in an attempt to decrease the potential for pressure induced tracheal injury. However, uncuffed endotracheal tube may increase the risk of aspiration and lead to erratic delivery of preset tidal volume during mechanical ventilation. Therefore, it is desirable to intubate trachea with an appropriate but not an oversized endotracheal tube. In children, for selecting an endotracheal tube, a variety of formulas and techniques are used to find the endotracheal tube size that minimizes both pressure induced tracheal injury and aspiration potential or variable ventilation. Air-leak following tracheal intubation can be recognized by the presence of audible leak, by auscultation over the trachea, by palpation over the trachea and by observing effects of positive end-expiratory pressure on inspiratory expiratory tidal volume difference during mechanical ventilation. We describe mainstream time-capnograph as an aid to recognize leak around the endotracheal tube and its utility to determine appropriate endotracheal tube size in small children.
- 1 December 2008
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 22 (6) , 887-889
Resolution of Airway Compression Induced by Transesophageal Echocardiography Probe Insertion in a Pediatric Patient After Repair of an Atrial Septal Defect and Partial Anomalous Pulmonary Venous Connection
- 1 December 2008
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 22 (6) , 887-889
Resolution of Airway Compression Induced by Transesophageal Echocardiography Probe Insertion in a Pediatric Patient After Repair of an Atrial Septal Defect and Partial Anomalous Pulmonary Venous Connection
- 1 October 2008
- Published by Wiley in Pediatric Anesthesia
- Vol. 18 (10) , 992-993
Extremely narrow airway in a child undergoing intracardiac repair of tetralogy of Fallot: perioperative implications
- 1 October 2008
- Published by Wiley in Pediatric Anesthesia
- Vol. 18 (10) , 992-993
Extremely narrow airway in a child undergoing intracardiac repair of tetralogy of Fallot: perioperative implications
- 2 September 2008
- Published by Wiley in Pediatric Anesthesia
- Vol. 18 (10) , 998-1000
Sinus venosus atrial septal defect closure in an achondroplastic dwarf: anesthetic and cardiopulmonary bypass management issues
- 2 September 2008
- Published by Wiley in Pediatric Anesthesia
- Vol. 18 (10) , 998-1000
Sinus venosus atrial septal defect closure in an achondroplastic dwarf: anesthetic and cardiopulmonary bypass management issues
- Open Access
- 15 December 2007
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 39 (4) , 257-259
An Innovative Simple Technique of Blood Conservation in Adult Patients with Tetralogy of Fallot and Severely Raised Hemoglobin
The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients because of the fear of possible hemodynamic instability, and hypoxemic spell. We describe an innovative, simple technique of blood conservation for adult patients of tetralogy of Fallot with severely raised hemoglobin. With this technique, hemoglobin can be normalized on CPB; moreover, there is no fear of hypoxemic spell or hemodynamic instability. Furthermore, the blood conserved is readily available for transfusion in the perioperative period, if needed.
- 15 December 2007
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 39 (4) , 257-259
Open AccessAn Innovative Simple Technique of Blood Conservation in Adult Patients with Tetralogy of Fallot and Severely Raised Hemoglobin
The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients because of the fear of possible hemodynamic instability, and hypoxemic spell. We describe an innovative, simple technique of blood conservation for adult patients of tetralogy of Fallot with severely raised hemoglobin. With this technique, hemoglobin can be normalized on CPB; moreover, there is no fear of hypoxemic spell or hemodynamic instability. Furthermore, the blood conserved is readily available for transfusion in the perioperative period, if needed.
- 1 July 2007
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 105 (1) , 40-42
Absent Right Superior Vena Cava and Persistent Left Superior Vena Cava: The Perioperative Implications
- 1 July 2007
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 105 (1) , 40-42
Absent Right Superior Vena Cava and Persistent Left Superior Vena Cava: The Perioperative Implications
- 1 April 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (2) , 288-297
Case 2—2007 Systemic Air Embolization After Termination of Cardiopulmonary Bypass
- 1 April 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (2) , 288-297
Case 2—2007 Systemic Air Embolization After Termination of Cardiopulmonary Bypass
- 1 February 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (2) , 159-160
A simple technique to secure the endotracheal tube over an intubating fibrescope
- 1 February 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (2) , 159-160
A simple technique to secure the endotracheal tube over an intubating fibrescope
- 1 December 2006
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 23 (12) , 1060-1061
Endotracheal tube migration following transoesophageal echocardiography probe placement in a child
- 1 December 2006
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 23 (12) , 1060-1061
Endotracheal tube migration following transoesophageal echocardiography probe placement in a child