Takashi Yarita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takashi Yarita has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Yoshie Aoyagi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 3, Umezono, Tsukuba, Ibaraki 305-8563, Japan
13 shared publications- Akiko Takatsu
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan
8 shared publications - Masahiko Numata
National Institute of Advanced Industrial Science and Technology (AIST)
7 shared publications - Takamitsu Otake
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST) , 1-1-1 Umezono , Tsukuba, Ibaraki 305-8563
6 shared publications Masahiko Numata
4 shared publications- Kazumi Inagaki
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
3 shared publications
Latest Publications
- Open Access
- 10 February 2013
- Published by Springer Nature in Analytical Sciences
- Vol. 29 (2) , 213-219
Separation of Parabens on a Zirconia-Based Stationary Phase in Superheated Water Chromatography
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 10 February 2013
- Published by Springer Nature in Analytical Sciences
- Vol. 29 (2) , 213-219
Open AccessSeparation of Parabens on a Zirconia-Based Stationary Phase in Superheated Water Chromatography
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 31 August 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 47 (10) , 942-948
Evaluation of pressurized liquid extraction for determination of organophosphorus and pyrethroid pesticides in soybean
The purpose of this study was to develop an analytical method for the determination of organophosphorus and pyrethroid pesticides in soybean by pressurized liquid extraction (PLE). Two organic solvents, acetone and acetonitrile, were evaluated as extraction solvents. In both cases, the amount of extract was enhanced with increasing extraction temperature. The extracts obtained using acetonitrile were measured by gas chromatography/mass spectrometry after a cleanup process based on the analytical method for the Japanese Positive List System for Agricultural Chemicals Remaining in Foods. The effect of extraction temperature (range: 40– 130°C) on extraction efficiency was evaluated by a recovery study using 21 organophosphorus pesticides and 10 pyrethroid pesticides as target analytes and acetonitrile as the solvent. The results indicated that at 130°C, some organophosphorus pesticides might be degraded, whereas extraction temperatures between 70°C and 100°C were optimal. Next, a prepared sample containing fenitrothion and permethrin was analyzed. Although the sample was not soaked in water prior to analysis, PLE provided analytical results comparable to those obtained by solvent extraction with homogenization. Therefore, PLE is considered a simple and alternative technique for the extraction of organophosphorus and pyrethroid pesticides in soybean.
- 31 August 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 47 (10) , 942-948
Evaluation of pressurized liquid extraction for determination of organophosphorus and pyrethroid pesticides in soybean
The purpose of this study was to develop an analytical method for the determination of organophosphorus and pyrethroid pesticides in soybean by pressurized liquid extraction (PLE). Two organic solvents, acetone and acetonitrile, were evaluated as extraction solvents. In both cases, the amount of extract was enhanced with increasing extraction temperature. The extracts obtained using acetonitrile were measured by gas chromatography/mass spectrometry after a cleanup process based on the analytical method for the Japanese Positive List System for Agricultural Chemicals Remaining in Foods. The effect of extraction temperature (range: 40– 130°C) on extraction efficiency was evaluated by a recovery study using 21 organophosphorus pesticides and 10 pyrethroid pesticides as target analytes and acetonitrile as the solvent. The results indicated that at 130°C, some organophosphorus pesticides might be degraded, whereas extraction temperatures between 70°C and 100°C were optimal. Next, a prepared sample containing fenitrothion and permethrin was analyzed. Although the sample was not soaked in water prior to analysis, PLE provided analytical results comparable to those obtained by solvent extraction with homogenization. Therefore, PLE is considered a simple and alternative technique for the extraction of organophosphorus and pyrethroid pesticides in soybean.
- 5 August 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 699 (1) , 49-56
Accurate quantification of polycyclic aromatic hydrocarbons in dust samples using microwave-assisted solvent extraction combined with isotope-dilution mass spectrometry
- 5 August 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 699 (1) , 49-56
Accurate quantification of polycyclic aromatic hydrocarbons in dust samples using microwave-assisted solvent extraction combined with isotope-dilution mass spectrometry
- 30 October 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (44) , 7488-7492
Determination of phosphorus using capillary electrophoresis and micro-high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry for the quantification of nucleotides
- 30 October 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (44) , 7488-7492
Determination of phosphorus using capillary electrophoresis and micro-high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry for the quantification of nucleotides
- 1 January 2009
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 58 (4) , 175-184
Total and Species-Specific Quantitative Analyses of Trace Elements in Sediment by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
- 1 January 2009
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 58 (4) , 175-184
Total and Species-Specific Quantitative Analyses of Trace Elements in Sediment by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
- 7 November 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1210 (1) , 68-75
Preparation of a sulfoxide group and ammonium-salt bonded silica stationary phase for separation of polychlorinated biphenyls from mineral oils
- 7 November 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1210 (1) , 68-75
Preparation of a sulfoxide group and ammonium-salt bonded silica stationary phase for separation of polychlorinated biphenyls from mineral oils
- Open Access
- 1 September 2008
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 91 (5) , 1124-1129
Evaluation of Microwave-Assisted Extraction for the Analysis of Polychlorinated Biphenyls and Organochlorine Pesticides in Fish
The efficiency of microwave-assisted extraction (MAE) was evaluated for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in fish. An isotope dilution method was used for quantification via analysis of the samples by gas chromatography and mass spectrometry. MAE solvent, temperature, and time were optimized, and observed concentrations were compared. The MAE results were also compared to those of other extraction techniques (Soxhlet extraction, pressurized liquid extraction, saponification, and homogenization). Concentrations of PCBs and OCPs obtained by MAE at 120C for 10 min were comparable to those by the other techniques. The results suggest that MAE can be used for the analysis of PCBs and OCPs in fish.
- 1 September 2008
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 91 (5) , 1124-1129
Open AccessEvaluation of Microwave-Assisted Extraction for the Analysis of Polychlorinated Biphenyls and Organochlorine Pesticides in Fish
The efficiency of microwave-assisted extraction (MAE) was evaluated for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in fish. An isotope dilution method was used for quantification via analysis of the samples by gas chromatography and mass spectrometry. MAE solvent, temperature, and time were optimized, and observed concentrations were compared. The MAE results were also compared to those of other extraction techniques (Soxhlet extraction, pressurized liquid extraction, saponification, and homogenization). Concentrations of PCBs and OCPs obtained by MAE at 120C for 10 min were comparable to those by the other techniques. The results suggest that MAE can be used for the analysis of PCBs and OCPs in fish.