Michael R. Armstrong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael R. Armstrong has a total of 495 co-authors. Here are the top co-authors by number of shared publications:
Jonathan C. Crowhurst
Lawrence Livermore National Laboratory, Livermore, USA
24 shared publicationsJoseph M. Zaug
Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA, 94550, USA
16 shared publicationsHarry B. Radousky
Lawrence Livermore National Laboratory, Livermore, USA
14 shared publications- Sorin Bastea
Lawrence Livermore National Laboratory
13 shared publications - Joseph M. Zaug
Lawrence Livermore National Laboratory, Physical and Life Sciences Directorate, P.O. Box 808 L-350, Livermore, California 94550, USA
11 shared publications Elissaios Stavrou
Lawrence Livermore National Laboratory 2 , Livermore, California 94550, USA
9 shared publications
Latest Publications
- 2 June 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (12) , 3285-3288
High-speed particle analysis using forward and backward two-dimensional angular optical scattering
Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized high-speed flying particles. The elastic-scattering intensity pattern from a single particle as a function of spherical coordinate angles θ and ϕ provides detailed information on the particle’s morphology. By use of an ellipsoidal reflector and a high-speed CCD camera, scattering from a CW-laser was detected and resolved over a large angular range ( θ from 12° to 168° and ϕ from 0° to 360°) from spherically shaped particles (e.g., amorphous silica and borosilicate glass) flowing through the reflector’s focal plane at speeds of 20 to 30 m/s. The scattering pattern from individual particles flying through the focal plane of the ellipsoid mirror provides insights about a particle’s size, clustering, roughness, and velocity.
- 2 June 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (12) , 3285-3288
High-speed particle analysis using forward and backward two-dimensional angular optical scattering
Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized high-speed flying particles. The elastic-scattering intensity pattern from a single particle as a function of spherical coordinate angles θ and ϕ provides detailed information on the particle’s morphology. By use of an ellipsoidal reflector and a high-speed CCD camera, scattering from a CW-laser was detected and resolved over a large angular range ( θ from 12° to 168° and ϕ from 0° to 360°) from spherically shaped particles (e.g., amorphous silica and borosilicate glass) flowing through the reflector’s focal plane at speeds of 20 to 30 m/s. The scattering pattern from individual particles flying through the focal plane of the ellipsoid mirror provides insights about a particle’s size, clustering, roughness, and velocity.
- Open Access
- 1 January 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (1)
Optimizing time integration for accurate recovery of shockwave interface location in radiography
We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.
- 1 January 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (1)
Open AccessOptimizing time integration for accurate recovery of shockwave interface location in radiography
We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution
We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution
We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.
- Open Access
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Open AccessCalibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- Open Access
- 11 June 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (22)
Equation of state measurement of detonation carbon condensates using optical microscopy and interferometry
Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K0 = 57.9(17) GPa] with HNS soot [K0 = 53.7(15) GPa], LX-21 soot [K0 = 45.8(51) GPa], and PBX 9502 soot [K0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.
- 11 June 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (22)
Open AccessEquation of state measurement of detonation carbon condensates using optical microscopy and interferometry
Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K0 = 57.9(17) GPa] with HNS soot [K0 = 53.7(15) GPa], LX-21 soot [K0 = 45.8(51) GPa], and PBX 9502 soot [K0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.
- Open Access
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Open AccessFemtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- 15 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (8) , 2784-2787
Shock measurements of alternative tamper materials YAG and GGG
Tamper materials allow for pressure maximization in a shock experiment up until their saturation limit. The Fabbro model provides the basis for the prediction for pressure enhancement from tamper materials. In this paper, we report the performance of two novel, to the best of our knowledge, tamper materials (yttrium aluminum garnet (YAG) and gadolinium gallium garnet (GGG)) using the Fabbro model and experimental data. The pressure enhancement using a laser-driven shock in the 2 GPa range and the saturation curve as these novel tampers compare to traditional tampers is explored. The unexpectedly low saturation points of YAG and GGG are discussed because of variable surface quality of commercially available samples. Overall, this study’s findings suggest that YAG and GGG show promise as alternative tampers, provided that anticipated enhancements in surface quality are achieved. At fluences of 5 J/cm2, a strong dependence of maximum pressure on the total acoustic impedance of the sample is not observed, and tamper selection becomes negligible.
- 15 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (8) , 2784-2787
Shock measurements of alternative tamper materials YAG and GGG
Tamper materials allow for pressure maximization in a shock experiment up until their saturation limit. The Fabbro model provides the basis for the prediction for pressure enhancement from tamper materials. In this paper, we report the performance of two novel, to the best of our knowledge, tamper materials (yttrium aluminum garnet (YAG) and gadolinium gallium garnet (GGG)) using the Fabbro model and experimental data. The pressure enhancement using a laser-driven shock in the 2 GPa range and the saturation curve as these novel tampers compare to traditional tampers is explored. The unexpectedly low saturation points of YAG and GGG are discussed because of variable surface quality of commercially available samples. Overall, this study’s findings suggest that YAG and GGG show promise as alternative tampers, provided that anticipated enhancements in surface quality are achieved. At fluences of 5 J/cm2, a strong dependence of maximum pressure on the total acoustic impedance of the sample is not observed, and tamper selection becomes negligible.
- 1 January 2025
- Published by Optica Publishing Group
- p. RTh1E.4
Quantifying the Location of a Moving 1D Interface in Time Integrated Radiography
Here we present simulations and experiments of time integrated radiographic imaging of a moving 1D interface. We discuss the trade-off between motion blurring of the interface and signal to noise with increasing integration time.
- 1 January 2025
- Published by Optica Publishing Group
- p. RTh1E.4
Quantifying the Location of a Moving 1D Interface in Time Integrated Radiography
Here we present simulations and experiments of time integrated radiographic imaging of a moving 1D interface. We discuss the trade-off between motion blurring of the interface and signal to noise with increasing integration time.