Joshua Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joshua Martin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Dylan J. Kirsch
Department of Materials Science and Engineering, University of Maryland, College Park, MD 20742, USA
3 shared publications - Ichiro Takeuchi
Department of Materials Science and Engineering, University of Maryland 2 , College Park, Maryland 20742
3 shared publications Winnie Wong-Ng
Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, USA
3 shared publications- Andrew S. Lee
Argonne National Laboratory
2 shared publications - Apurva Mehta
SLAC National Accelerator Laboratory, Menlo Park, CA, United States
2 shared publications - Christopher K. H. Borg
Citrine Informatics, Redwood City, USA
2 shared publications
Latest Publications
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Frequency Domain Thermoreflectance (FDTR) is a versatile technique used to measure the thermal properties of thin films, multilayer stacks, and interfaces that govern the performance and thermal management in semiconductor microelectronics. Reliable thermal property measurements at these length scales (≈10 nm to ≈10 μm), where the physics of thermal transport and phonon scattering at interfaces both grow in complexity, are increasingly relevant as electronic components continue to shrink. While FDTR is a promising technique, FDTR instruments are generally home-built; they can be difficult to construct, align, and maintain, especially for the novice. Our goal here is to provide a practical resource beyond theory that increases the accessibility, replicability, and widespread adoption of FDTR instrumentation. We provide a detailed account of unpublished insights and institutional knowledge that are critical for obtaining accurate and repeatable measurements of thermal properties using FDTR. We discuss component selection and placement, alignment procedures, data collection parameters, common challenges, and our efforts to increase measurement automation. In FDTR, the unknown thermal properties are fit by minimizing the error between the phase lag at each frequency and the multilayer diffusive thermal model solution. For data fitting and uncertainty analysis, we compare common numerical integration methods, and we compare multiple approaches for fitting and uncertainty analysis, including Monte Carlo simulation, to demonstrate their reliability and relative speed. The instrument is validated with substrates of known thermal properties over a wide range of isotropic thermal conductivities, including Borofloat silica, quartz, sapphire, and silicon.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessAn instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Frequency Domain Thermoreflectance (FDTR) is a versatile technique used to measure the thermal properties of thin films, multilayer stacks, and interfaces that govern the performance and thermal management in semiconductor microelectronics. Reliable thermal property measurements at these length scales (≈10 nm to ≈10 μm), where the physics of thermal transport and phonon scattering at interfaces both grow in complexity, are increasingly relevant as electronic components continue to shrink. While FDTR is a promising technique, FDTR instruments are generally home-built; they can be difficult to construct, align, and maintain, especially for the novice. Our goal here is to provide a practical resource beyond theory that increases the accessibility, replicability, and widespread adoption of FDTR instrumentation. We provide a detailed account of unpublished insights and institutional knowledge that are critical for obtaining accurate and repeatable measurements of thermal properties using FDTR. We discuss component selection and placement, alignment procedures, data collection parameters, common challenges, and our efforts to increase measurement automation. In FDTR, the unknown thermal properties are fit by minimizing the error between the phase lag at each frequency and the multilayer diffusive thermal model solution. For data fitting and uncertainty analysis, we compare common numerical integration methods, and we compare multiple approaches for fitting and uncertainty analysis, including Monte Carlo simulation, to demonstrate their reliability and relative speed. The instrument is validated with substrates of known thermal properties over a wide range of isotropic thermal conductivities, including Borofloat silica, quartz, sapphire, and silicon.
- 22 March 2024
- Published by Springer Nature in Integrating Materials and Manufacturing Innovation
- Vol. 13 (2) , 406-419
A Case Study of Multimodal, Multi-institutional Data Management for the Combinatorial Materials Science Community
- 22 March 2024
- Published by Springer Nature in Integrating Materials and Manufacturing Innovation
- Vol. 13 (2) , 406-419
A Case Study of Multimodal, Multi-institutional Data Management for the Combinatorial Materials Science Community
- Open Access
A case study of multi-modal, multi-institutional data management for the combinatorial materials science community
Although the convergence of high-performance computing, automation, and machine learning has significantly altered the materials design timeline, transformative advances in functional materials and acceleration of their design will require addressing the deficiencies that currently exist in materials informatics, particularly a lack of standardized experimental data management. The challenges associated with experimental data management are especially true for combinatorial materials science, where advancements in automation of experimental workflows have produced datasets that are often too large and too complex for human reasoning. The data management challenge is further compounded by the multi-modal and multi-institutional nature of these datasets, as they tend to be distributed across multiple institutions and can vary substantially in format, size, and content. To adequately map a materials design space from such datasets, an ideal materials data infrastructure would contain data and metadata describing i) synthesis and processing conditions, ii) characterization results, and iii) property and performance measurements. Here, we present a case study for the low-barrier development of such a dashboard that enables standardized organization, analysis, and visualization of a large data lake consisting of combinatorial datasets of synthesis and processing conditions, X-ray diffraction patterns, and materials property measurements generated at several different institutions. While this dashboard was developed specifically for data-driven thermoelectric materials discovery, we envision the adaptation of this prototype to other materials applications, and, more ambitiously, future integration into an all-encompassing materials data management infrastructure.
Open AccessA case study of multi-modal, multi-institutional data management for the combinatorial materials science community
Although the convergence of high-performance computing, automation, and machine learning has significantly altered the materials design timeline, transformative advances in functional materials and acceleration of their design will require addressing the deficiencies that currently exist in materials informatics, particularly a lack of standardized experimental data management. The challenges associated with experimental data management are especially true for combinatorial materials science, where advancements in automation of experimental workflows have produced datasets that are often too large and too complex for human reasoning. The data management challenge is further compounded by the multi-modal and multi-institutional nature of these datasets, as they tend to be distributed across multiple institutions and can vary substantially in format, size, and content. To adequately map a materials design space from such datasets, an ideal materials data infrastructure would contain data and metadata describing i) synthesis and processing conditions, ii) characterization results, and iii) property and performance measurements. Here, we present a case study for the low-barrier development of such a dashboard that enables standardized organization, analysis, and visualization of a large data lake consisting of combinatorial datasets of synthesis and processing conditions, X-ray diffraction patterns, and materials property measurements generated at several different institutions. While this dashboard was developed specifically for data-driven thermoelectric materials discovery, we envision the adaptation of this prototype to other materials applications, and, more ambitiously, future integration into an all-encompassing materials data management infrastructure.
- 3 January 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (1) , 18-19
Thermoelectric measurements
- 3 January 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (1) , 18-19
Thermoelectric measurements
- 28 August 2021
- Published by Springer Nature in Journal of Materials Research
- Vol. 36 (16) , 3339-3352
Development of a high-temperature (295–900 K) Seebeck coefficient Standard Reference Material
- 28 August 2021
- Published by Springer Nature in Journal of Materials Research
- Vol. 36 (16) , 3339-3352
Development of a high-temperature (295–900 K) Seebeck coefficient Standard Reference Material
- 29 January 2015
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 44 (6) , 1998-2006
Seebeck Coefficient Metrology: Do Contemporary Protocols Measure Up?
- 29 January 2015
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 44 (6) , 1998-2006
Seebeck Coefficient Metrology: Do Contemporary Protocols Measure Up?
- 20 May 2014
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 115 (19) , 193501
Thermocyclic stability of candidate Seebeck coefficient standard reference materials at high temperature
The Seebeck coefficient is the most widely measured property specific to thermoelectric materials. There is currently no consensus on measurement protocols, and researchers employ a variety of techniques to measure the Seebeck coefficient. The implementation of standardized measurement protocols and the use of reliable Seebeck Coefficient Standard Reference Materials (SRMs®) will allow the accurate interlaboratory comparison and validation of materials data, thereby accelerating the development and commercialization of more efficient thermoelectric materials and devices. To enable members of the thermoelectric materials community the means to calibrate Seebeck coefficient measurement equipment, NIST certified SRM® 3451 “Low Temperature Seebeck Coefficient Standard (10 K to 390 K)”. Due to different practical requirements in instrumentation, sample contact methodology, and thermal stability, a complementary SRM® is required for the high temperature regime (300 K to 900 K). The principal requirement of a SRM® for the Seebeck coefficient at high temperature is thermocyclic stability. We therefore characterized the thermocyclic behavior of the Seebeck coefficient for a series of candidate materials: constantan, p-type single crystal SiGe, and p-type polycrystalline SiGe, by measuring the temperature dependence of the Seebeck coefficient as a function of 10 sequential thermal cycles, between 300 K and 900 K. We employed multiple regression analysis to interpolate and analyze the thermocyclic variability in the measurement curves.
- 20 May 2014
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 115 (19) , 193501
Thermocyclic stability of candidate Seebeck coefficient standard reference materials at high temperature
The Seebeck coefficient is the most widely measured property specific to thermoelectric materials. There is currently no consensus on measurement protocols, and researchers employ a variety of techniques to measure the Seebeck coefficient. The implementation of standardized measurement protocols and the use of reliable Seebeck Coefficient Standard Reference Materials (SRMs®) will allow the accurate interlaboratory comparison and validation of materials data, thereby accelerating the development and commercialization of more efficient thermoelectric materials and devices. To enable members of the thermoelectric materials community the means to calibrate Seebeck coefficient measurement equipment, NIST certified SRM® 3451 “Low Temperature Seebeck Coefficient Standard (10 K to 390 K)”. Due to different practical requirements in instrumentation, sample contact methodology, and thermal stability, a complementary SRM® is required for the high temperature regime (300 K to 900 K). The principal requirement of a SRM® for the Seebeck coefficient at high temperature is thermocyclic stability. We therefore characterized the thermocyclic behavior of the Seebeck coefficient for a series of candidate materials: constantan, p-type single crystal SiGe, and p-type polycrystalline SiGe, by measuring the temperature dependence of the Seebeck coefficient as a function of 10 sequential thermal cycles, between 300 K and 900 K. We employed multiple regression analysis to interpolate and analyze the thermocyclic variability in the measurement curves.
- 2 July 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (8) , 085601
Protocols for the high temperature measurement of the Seebeck coefficient in thermoelectric materials
In Seebeck coefficient metrology, the present diversity in apparatus design, acquisition methodology and contact geometry has resulted in conflicting materials data that complicate the interlaboratory confirmation of reported high efficiency thermoelectric materials. To elucidate the influence of these factors in the measurement of the Seebeck coefficient at high temperature and to identify optimal metrology protocols, we measure the Seebeck coefficient as a function of contact geometry under both steady-state and transient thermal conditions of the differential method, using a custom developed apparatus capable of in situ comparative measurement. The thermal gradient formation and data acquisition methodology, under ideal conditions, have little effect on the measured Seebeck coefficient value. However, the off-axis 4-probe contact geometry, as compared to the 2-probe, results in a greater local temperature measurement error that increases with temperature. For surface temperature measurement, the dominant thermal errors arise from a parasitic heat flux that is dependent on the temperature difference between the sample and the external thermal environment, and on the various thermal resistances. Due to higher macroconstriction and contact resistance in the 4-probe arrangement, the measurement of surface temperature for this contact geometry exhibits greater error, thereby overestimating the Seebeck coefficient.
- 2 July 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (8) , 085601
Protocols for the high temperature measurement of the Seebeck coefficient in thermoelectric materials
In Seebeck coefficient metrology, the present diversity in apparatus design, acquisition methodology and contact geometry has resulted in conflicting materials data that complicate the interlaboratory confirmation of reported high efficiency thermoelectric materials. To elucidate the influence of these factors in the measurement of the Seebeck coefficient at high temperature and to identify optimal metrology protocols, we measure the Seebeck coefficient as a function of contact geometry under both steady-state and transient thermal conditions of the differential method, using a custom developed apparatus capable of in situ comparative measurement. The thermal gradient formation and data acquisition methodology, under ideal conditions, have little effect on the measured Seebeck coefficient value. However, the off-axis 4-probe contact geometry, as compared to the 2-probe, results in a greater local temperature measurement error that increases with temperature. For surface temperature measurement, the dominant thermal errors arise from a parasitic heat flux that is dependent on the temperature difference between the sample and the external thermal environment, and on the various thermal resistances. Due to higher macroconstriction and contact resistance in the 4-probe arrangement, the measurement of surface temperature for this contact geometry exhibits greater error, thereby overestimating the Seebeck coefficient.
- 28 August 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 42 (7) , 1358-1364
Error Modeling of Seebeck Coefficient Measurements Using Finite-Element Analysis
- 28 August 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 42 (7) , 1358-1364
Error Modeling of Seebeck Coefficient Measurements Using Finite-Element Analysis
- 1 June 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (6) , 065101
Apparatus for the high temperature measurement of the Seebeck coefficient in thermoelectric materials
The Seebeck coefficient is a physical parameter routinely measured to identify the potential thermoelectric performance of a material. However, researchers employ a variety of techniques, conditions, and probe arrangements to measure the Seebeck coefficient, resulting in conflicting materials data. To compare and evaluate these methodologies, and to identify optimal Seebeck coefficient measurement protocols, we have developed an improved experimental apparatus to measure the Seebeck coefficient under multiple conditions and probe arrangements (300 K–1200 K). This paper will describe in detail the apparatus design and instrumentation, including a discussion of its capabilities and accuracy as measured through representative diagnostics. In addition, this paper will emphasize the techniques required to effectively manage uncertainty in high temperature Seebeck coefficient measurements.
- 1 June 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (6) , 065101
Apparatus for the high temperature measurement of the Seebeck coefficient in thermoelectric materials
The Seebeck coefficient is a physical parameter routinely measured to identify the potential thermoelectric performance of a material. However, researchers employ a variety of techniques, conditions, and probe arrangements to measure the Seebeck coefficient, resulting in conflicting materials data. To compare and evaluate these methodologies, and to identify optimal Seebeck coefficient measurement protocols, we have developed an improved experimental apparatus to measure the Seebeck coefficient under multiple conditions and probe arrangements (300 K–1200 K). This paper will describe in detail the apparatus design and instrumentation, including a discussion of its capabilities and accuracy as measured through representative diagnostics. In addition, this paper will emphasize the techniques required to effectively manage uncertainty in high temperature Seebeck coefficient measurements.