Manoj M. Varma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manoj M. Varma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Prashanth R. Prasad
Department of Electrical Communication Engineering, Indian Institute of Science, Bangalore, India
2 shared publicationsShankar K. Selvaraja
Centre for Nanoscience and Engineering, Indian Institute of Science, Bangalore, India
2 shared publicationsGurusiddappa R. Prashanth
Department of Electrical Communication Engineering and the Centre for Nano Science and Engineering, Indian Institute of Science, Bangalore, India
1 shared publicationSwathi Suran
Centre for Nano Science and Engineering, Indian Institute of Science, Bangalore, India
1 shared publicationVenkanagouda Shivanagouda Goudar
Centre for Nano Science and Engineering, Indian Institute of Science, Bangalore, India
1 shared publication
Latest Publications
- 13 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 34 (22) , 5157-5163
Full-Range Detection in Cascaded Microring Sensors Using Thermooptical Tuning
We present detailed analysis and experimental demonstration of full-range detection in cascaded microring sensors by using thermooptical tuning. A cascaded microring sensor translates spectrum shifts into intensity changes eliminating the need for expensive spectral analysis equipment for sensing applications. Without tuning capability, this configuration provides high sensitivity, but a small detection range since the intensity output decays toward zero for low overlap between spectra of individual microrings. We overcome this limitation by using thermooptic tuning in one of the microrings for extending the detection range to span an entire free spectral range of the probing microring. Additionally, we analyze the impact of resonance linewidths and differences in free spectral ranges (FSRs) of microrings on the widths of output intensity peaks. With full FSR thermooptical tuning, we demonstrate a total detection range of 0.0241 refractive index units (RIU) and a limit of detection of 4.6 × 10 -5 RIU for microrings with 100-μm radii. Photodetector-based signal readout combined with CMOS compatible manufacturability makes this device design attractive as a silicon-based optical sensing platform.
- 13 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 34 (22) , 5157-5163
Full-Range Detection in Cascaded Microring Sensors Using Thermooptical Tuning
We present detailed analysis and experimental demonstration of full-range detection in cascaded microring sensors by using thermooptical tuning. A cascaded microring sensor translates spectrum shifts into intensity changes eliminating the need for expensive spectral analysis equipment for sensing applications. Without tuning capability, this configuration provides high sensitivity, but a small detection range since the intensity output decays toward zero for low overlap between spectra of individual microrings. We overcome this limitation by using thermooptic tuning in one of the microrings for extending the detection range to span an entire free spectral range of the probing microring. Additionally, we analyze the impact of resonance linewidths and differences in free spectral ranges (FSRs) of microrings on the widths of output intensity peaks. With full FSR thermooptical tuning, we demonstrate a total detection range of 0.0241 refractive index units (RIU) and a limit of detection of 4.6 × 10 -5 RIU for microrings with 100-μm radii. Photodetector-based signal readout combined with CMOS compatible manufacturability makes this device design attractive as a silicon-based optical sensing platform.
- 5 July 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (14) , 3153-3156
High precision measurement of intensity peak shifts in tunable cascaded microring intensity sensors
We demonstrate a method to precisely track intensity peak shifts in tunable cascaded double-microring based refractive index sensors. Without modifications, width of the intensity peak of a tunable cascaded microring device limits the precision of peak-shift measurements and thereby the limit of detection of the sensor. We overcome this limitation by using dual harmonic lock-in detection for precisely determining the position of the intensity maximum. Using this modification, we have demonstrated a reduction in the full width at half-maximum (FWHM) of the intensity peak by a factor of over 1300. We show that such a reduction in FWHM of the peak curve can significantly improve the detection limit of a tunable cascaded microring-based sensor.
- 5 July 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (14) , 3153-3156
High precision measurement of intensity peak shifts in tunable cascaded microring intensity sensors
We demonstrate a method to precisely track intensity peak shifts in tunable cascaded double-microring based refractive index sensors. Without modifications, width of the intensity peak of a tunable cascaded microring device limits the precision of peak-shift measurements and thereby the limit of detection of the sensor. We overcome this limitation by using dual harmonic lock-in detection for precisely determining the position of the intensity maximum. Using this modification, we have demonstrated a reduction in the full width at half-maximum (FWHM) of the intensity peak by a factor of over 1300. We show that such a reduction in FWHM of the peak curve can significantly improve the detection limit of a tunable cascaded microring-based sensor.
- 18 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 13 (12) , 4817-4823
Detection of Hepatitis B DNA Sequences on Polyelectrolyte Based Non-Covalently Functionalized Flexible Plastic Substrates
Development of simple functionalization methods to attach biomolecules such as proteins and DNA on inexpensive substrates is important for widespread use of low cost, disposable biosensors. Here, we describe a method based on polyelectrolyte multilayers to attach single stranded DNA molecules to conventional glass slides as well as a completely non-standard substrate, namely flexible plastic transparency sheets. We then use the functionalized transparency sheets to specifically detect single stranded Hepatitis B DNA sequences from samples. We also demonstrate a blocking method for reducing non-specific binding of target DNA sequences using negatively charged polyelectrolyte molecules. The polyelectrolyte based functionalization method, which relies on surface charge as opposed to covalent surface linkages, could be an attractive platform to develop assays on inexpensive substrates for low cost biosensing.
- 18 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 13 (12) , 4817-4823
Detection of Hepatitis B DNA Sequences on Polyelectrolyte Based Non-Covalently Functionalized Flexible Plastic Substrates
Development of simple functionalization methods to attach biomolecules such as proteins and DNA on inexpensive substrates is important for widespread use of low cost, disposable biosensors. Here, we describe a method based on polyelectrolyte multilayers to attach single stranded DNA molecules to conventional glass slides as well as a completely non-standard substrate, namely flexible plastic transparency sheets. We then use the functionalized transparency sheets to specifically detect single stranded Hepatitis B DNA sequences from samples. We also demonstrate a blocking method for reducing non-specific binding of target DNA sequences using negatively charged polyelectrolyte molecules. The polyelectrolyte based functionalization method, which relies on surface charge as opposed to covalent surface linkages, could be an attractive platform to develop assays on inexpensive substrates for low cost biosensing.