The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dennis F. Bandyk has a total of 299 co-authors. Here are the top co-authors by number of shared publications:
- Brad L. Johnson
University of South Florida, Department of Surgery Division of Vascular Surgery, Tampa, FL
6 shared publications - Martin R. Back
Division of Vascular and Endovascular Surgery, University of South Florida College of Medicine, Tampa, FL 33606, USA
6 shared publications - Murray L. Shames
University of South Florida, Tampa, Fla
4 shared publications Paul A. Armstrong
4 shared publicationsPatrick A. Stone
West Virginia University, Charleston Area Medical Center
3 shared publicationsA. Ross Myers
Division of Vascular and Endovascular Surgery, University of South Florida College of Medicine, Tampa, Florida
2 shared publications
Latest Publications
- 4 July 2012
- Published by Springer Nature
- p. 321-332
Duplex Surveillance of Infrainguinal Bypass Grafts
- 1 January 2012
- Published by Elsevier
- p. 307-323
Ultrasound Assessment During and after carotid and Peripheral Intervention
- 1 January 2012
- Published by Elsevier
- p. 307-323
Ultrasound Assessment During and after carotid and Peripheral Intervention
- 1 December 2011
- Published by Elsevier in Seminars in Vascular Surgery
- Vol. 24 (4) , 191-198
Antibiotic Therapy of Aortic Graft Infection: Treatment and Prevention Recommendations
- 1 December 2011
- Published by Elsevier in Seminars in Vascular Surgery
- Vol. 24 (4) , 191-198
Antibiotic Therapy of Aortic Graft Infection: Treatment and Prevention Recommendations
- 1 January 2010
- Published by Elsevier
Contributors
- 31 December 2009
- Published by Elsevier in Journal of Surgical Research
- Vol. 157 (2) , 223-226
Regional Antibiotic Delivery for the Treatment of Experimental Prosthetic Graft Infections
- 31 December 2009
- Published by Elsevier in Journal of Surgical Research
- Vol. 157 (2) , 223-226
Regional Antibiotic Delivery for the Treatment of Experimental Prosthetic Graft Infections
- 1 December 2009
- Vol. 50 (6) , 727-33
Use of intravascular ultrasound as a "Quality Control" technique during carotid stent-angioplasty: are there risks to its use?
Intravascular ultrasound (IVUS) provides high-resolution vessel imaging and has been shown to improve clinical outcomes when used to assess the technical result of peripheral angioplasty procedures. Our vascular group compared anatomic and clinical outcomes of carotid artery stent-angioplasty (CAS) performed with angiogram monitoring alone, or in combination with IVUS imaging to select stent/balloon diameter and interrogate stent deployment region for residual stenosis. A retrospective review of our carotid stent registry (N=306) identified 220 CAS procedures performed with either a digital C-arm fluoroscopy alone (N=110) or in conjunction with IVUS (N=110) with at least 6-month of clinical follow-up. Outcome measures of procedure time, angioplasty balloon diameter, contrast dye volume, Duplex surveillance testing for recurrent stenosis, and procedure event (death, cardiac, neurologic) rates were compared to assess the risks and benefits of IVUS. All procedures utilized a cerebral protection device deployed prior to IVUS imaging. Procedure times were similar, but IVUS usage resulted in lower (P50% diameter-reducing in-stent stenosis in the angio alone group (11% vs 7% at 1 month ; 24% vs 6% at last surveillance; mean 36 moontha; range: 6-66 months). The quality control of the CAS procedure was enhanced by IVUS imaging which directed stent /balloon sizing and was more accurate than angiography in confirming adequate stent expansion. No IVUS related adverse events occurred. Based on the anatomic information provided by IVUS, larger diameter angioplasty balloons were used which correlated with less residual stenosis after CAS based on duplex ultrasound testing.
- 1 December 2009
- Vol. 50 (6) , 727-33
Use of intravascular ultrasound as a "Quality Control" technique during carotid stent-angioplasty: are there risks to its use?
Intravascular ultrasound (IVUS) provides high-resolution vessel imaging and has been shown to improve clinical outcomes when used to assess the technical result of peripheral angioplasty procedures. Our vascular group compared anatomic and clinical outcomes of carotid artery stent-angioplasty (CAS) performed with angiogram monitoring alone, or in combination with IVUS imaging to select stent/balloon diameter and interrogate stent deployment region for residual stenosis. A retrospective review of our carotid stent registry (N=306) identified 220 CAS procedures performed with either a digital C-arm fluoroscopy alone (N=110) or in conjunction with IVUS (N=110) with at least 6-month of clinical follow-up. Outcome measures of procedure time, angioplasty balloon diameter, contrast dye volume, Duplex surveillance testing for recurrent stenosis, and procedure event (death, cardiac, neurologic) rates were compared to assess the risks and benefits of IVUS. All procedures utilized a cerebral protection device deployed prior to IVUS imaging. Procedure times were similar, but IVUS usage resulted in lower (P50% diameter-reducing in-stent stenosis in the angio alone group (11% vs 7% at 1 month ; 24% vs 6% at last surveillance; mean 36 moontha; range: 6-66 months). The quality control of the CAS procedure was enhanced by IVUS imaging which directed stent /balloon sizing and was more accurate than angiography in confirming adequate stent expansion. No IVUS related adverse events occurred. Based on the anatomic information provided by IVUS, larger diameter angioplasty balloons were used which correlated with less residual stenosis after CAS based on duplex ultrasound testing.
- 1 September 2008
- Published by Elsevier in Seminars in Vascular Surgery
- Vol. 21 (3) , 119-123
Vascular Surgical Site Infection: Risk Factors and Preventive Measures
- 1 September 2008
- Published by Elsevier in Seminars in Vascular Surgery
- Vol. 21 (3) , 119-123
Vascular Surgical Site Infection: Risk Factors and Preventive Measures
- 29 February 2008
- Published by Elsevier in Journal of Surgical Research
- Vol. 144 (2) , 331-332
QS162. Regional Antibiosis for The Treatment of Experimental Prosthetic Graft Infections
- 29 February 2008
- Published by Elsevier in Journal of Surgical Research
- Vol. 144 (2) , 331-332
QS162. Regional Antibiosis for The Treatment of Experimental Prosthetic Graft Infections
- 1 December 2007
- Published by SAGE Publications in Perspectives in Vascular Surgery and Endovascular Therapy
- Vol. 19 (4) , 376-383
Surveillance After Lower Extremity Arterial Bypass
The elements of a surveillance program after lower limb bypass grafting to enhance graft patency continue to evolve. Graft evaluation should include clinical assessment for new or changes in limb ischemia symptoms, measurement of ankle or toe systolic pressure, or both, and duplex ultrasound imaging of the bypass graft, which in the early postoperative period is predictive of the subsequent need for bypass graft revision. The natural history of moderate graft stenosis is known, and these lesions can be safely monitored using serial testing to identify progression. The testing frequency should be individualized to the patient, type of arterial bypass, and duplex scan findings. Graft surveillance should focus on the identification and repair of critical stenosis (peak systolic velocity exceeding 300 cm/s, and peak systolic velocity ratio across the stenosis exceeding 3.5) correlating with more than 70% diameter-reducing stenosis. A graft surveillance program should result in a graft failure rate of less than 3% per year.
- 1 December 2007
- Published by SAGE Publications in Perspectives in Vascular Surgery and Endovascular Therapy
- Vol. 19 (4) , 376-383
Surveillance After Lower Extremity Arterial Bypass
The elements of a surveillance program after lower limb bypass grafting to enhance graft patency continue to evolve. Graft evaluation should include clinical assessment for new or changes in limb ischemia symptoms, measurement of ankle or toe systolic pressure, or both, and duplex ultrasound imaging of the bypass graft, which in the early postoperative period is predictive of the subsequent need for bypass graft revision. The natural history of moderate graft stenosis is known, and these lesions can be safely monitored using serial testing to identify progression. The testing frequency should be individualized to the patient, type of arterial bypass, and duplex scan findings. Graft surveillance should focus on the identification and repair of critical stenosis (peak systolic velocity exceeding 300 cm/s, and peak systolic velocity ratio across the stenosis exceeding 3.5) correlating with more than 70% diameter-reducing stenosis. A graft surveillance program should result in a graft failure rate of less than 3% per year.
- 1 December 2007
- Published by SAGE Publications in Perspectives in Vascular Surgery and Endovascular Therapy
- Vol. 19 (4) , 354-359
Duplex Ultrasound Surveillance Can Be Worthwhile After Arterial Intervention
Carotid duplex ultrasound testing provides a safe and accurate method to detect and grade the severity of atherosclerotic internal carotid artery stenosis both before and following carotid intervention. Testing after surgical endarterectomy or stent angioplasty allows assessment of the technical success by excluding residual stenosis. The focus of duplex surveillance after carotid intervention is to identify recurrent stenosis, repair site occlusion, and progression of contralateral internal carotid artery disease. Patients who develop a neurologic event or a duplex-detected >75% diameter-reducing internal carotid artery stenosis with a peak systolic velocity >300 cm/s and end-diastolic velocity >125 cm/s should be further evaluated by angiographic imaging and should be considered for reintervention if an appropriate lesion is confirmed. Duplex surveillance allows the vascular surgeon to evaluate patency of the rendered intervention, its stenosis-free durability, and its effectiveness in stroke prevention.
- 1 December 2007
- Published by SAGE Publications in Perspectives in Vascular Surgery and Endovascular Therapy
- Vol. 19 (4) , 354-359
Duplex Ultrasound Surveillance Can Be Worthwhile After Arterial Intervention
Carotid duplex ultrasound testing provides a safe and accurate method to detect and grade the severity of atherosclerotic internal carotid artery stenosis both before and following carotid intervention. Testing after surgical endarterectomy or stent angioplasty allows assessment of the technical success by excluding residual stenosis. The focus of duplex surveillance after carotid intervention is to identify recurrent stenosis, repair site occlusion, and progression of contralateral internal carotid artery disease. Patients who develop a neurologic event or a duplex-detected >75% diameter-reducing internal carotid artery stenosis with a peak systolic velocity >300 cm/s and end-diastolic velocity >125 cm/s should be further evaluated by angiographic imaging and should be considered for reintervention if an appropriate lesion is confirmed. Duplex surveillance allows the vascular surgeon to evaluate patency of the rendered intervention, its stenosis-free durability, and its effectiveness in stroke prevention.