Carol Lakkis
Research Subjects
Research Interests
Carol Lakkis has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Barry L. Cole
Department of Optometry and Vision Sciences, University of Melbourne, Victoria, Australia
1 shared publication Genevieve Napper
Melbourne Optometry Clinic, Victorian College of Optometry, Carlton, Victoria, Australia
1 shared publicationKa-Yee Lian
1 shared publicationKate Weidemann
Clinical Vision Research Australia
1 shared publicationKa‐Yee Lian
Clinical Vision Research Australia, Carlton, Victoria, Australia
1 shared publicationPatricia M Kiely
Optometrists Association Australia, Carlton, Victoria, Australia E‐mail
1 shared publication
Latest Publications
- 1 November 2007
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 90 (6) , 434-444
Infection control guidelines for optometrists 2007
Information from peer-reviewed articles, guidelines from professional societies and manufacturers' instructions were considered to determine the risk factors in optometric practice and to make recommendations for disinfection, sterilisation and reprocessing of instrumentation and other equipment used in practice and measures for personal protection. Wherever possible, all practitioners should adopt measures to decrease the risk of transmission of infection, such as single use instruments/equipment, appropriate methods of reprocessing where items are reused, routine employment of standard infection control precautions and application of more rigorous procedures for infected or immuno-suppressed individuals.
- 1 November 2007
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 90 (6) , 434-444
Infection control guidelines for optometrists 2007
Information from peer-reviewed articles, guidelines from professional societies and manufacturers' instructions were considered to determine the risk factors in optometric practice and to make recommendations for disinfection, sterilisation and reprocessing of instrumentation and other equipment used in practice and measures for personal protection. Wherever possible, all practitioners should adopt measures to decrease the risk of transmission of infection, such as single use instruments/equipment, appropriate methods of reprocessing where items are reused, routine employment of standard infection control precautions and application of more rigorous procedures for infected or immuno-suppressed individuals.
- 1 January 2007
- Vol. 78 (1) , 21-5
Can color vision defective subjects who pass the farnsworth lantern test recognize surface color codes?
The International Civil Aviation Organization requires that pilots be able to distinguish the colors used in air navigation and in particular be able to identify the colors of signal lights. Most national aviation authorities use a lantern test to assess the ability of applicants for a pilot's license who have abnormal color vision to recognize the colors of signal lights. However, color-coding is now widely used in aviation systems other than signal lights. Color is used in tarmac markings, maps, manuals, and electronic flight instrument displays. These color codes can use 10 or more colors, many more than the 3 to 5 used for signal lights. This study investigated whether people with defective color vision (DCV) who pass the Farnsworth lantern test can recognize the main colors used for surface color codes. There were 99 subjects with DCV who were tested using the Optec 900 version of the Farnsworth lantern test and also named the colors of a set of 10 surface colors that varied in shape (dots and lines) and size (3 sizes; angular diameters 0.27, 1.0, and 2.4 degrees; angular widths 0.14, 0.27, and 0.50 degrees). A control group of 20 subjects with normal color vision also named the surface colors. Of the DCV subjects, 19% passed the Farnsworth lantern test, of whom 74% made no errors with the surface colors. The other 26% made few errors (up to 5 errors in 120 presentations) and those errors were mostly to confuse red, orange, and brown. The subjects with normal color vision made no errors naming the surface colors. Those who pass the Farnsworth lantern test can recognize the colors of a 10-color surface color code with few or no errors. This is because the small (2.9-min arc) stimulus of the lantern test presents a more difficult task than the larger surface colors.
- 1 January 2007
- Vol. 78 (1) , 21-5
Can color vision defective subjects who pass the farnsworth lantern test recognize surface color codes?
The International Civil Aviation Organization requires that pilots be able to distinguish the colors used in air navigation and in particular be able to identify the colors of signal lights. Most national aviation authorities use a lantern test to assess the ability of applicants for a pilot's license who have abnormal color vision to recognize the colors of signal lights. However, color-coding is now widely used in aviation systems other than signal lights. Color is used in tarmac markings, maps, manuals, and electronic flight instrument displays. These color codes can use 10 or more colors, many more than the 3 to 5 used for signal lights. This study investigated whether people with defective color vision (DCV) who pass the Farnsworth lantern test can recognize the main colors used for surface color codes. There were 99 subjects with DCV who were tested using the Optec 900 version of the Farnsworth lantern test and also named the colors of a set of 10 surface colors that varied in shape (dots and lines) and size (3 sizes; angular diameters 0.27, 1.0, and 2.4 degrees; angular widths 0.14, 0.27, and 0.50 degrees). A control group of 20 subjects with normal color vision also named the surface colors. Of the DCV subjects, 19% passed the Farnsworth lantern test, of whom 74% made no errors with the surface colors. The other 26% made few errors (up to 5 errors in 120 presentations) and those errors were mostly to confuse red, orange, and brown. The subjects with normal color vision made no errors naming the surface colors. Those who pass the Farnsworth lantern test can recognize the colors of a 10-color surface color code with few or no errors. This is because the small (2.9-min arc) stimulus of the lantern test presents a more difficult task than the larger surface colors.
- 1 July 2006
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 89 (4) , 246-252
Evaluation of the performance of photochromic spectacle lenses in children and adolescents aged 10 to 15 years
To compare the performance of clear and photochromic spectacle lenses in children and adolescents, with respect to visual acuity and satisfaction with day-to-day activities. Fifty full-time spectacle wearers, aged 10 to 15 years, were randomly assigned to wear clear and Transitions photochromic spectacle lenses for two weeks each in a crossover fashion. Subjects were evaluated at screening, lens delivery and two weeks post-delivery. At each visit, distance and near visual acuity (VA, logMAR) were assessed and subjective questionnaires, using Likert scales, were administered. Parents/guardians also completed questionnaires at entry and exit from the study. There were no significant differences in VA between clear and photochromic lenses (p > 0.05) and no difficulties were encountered with completion of the questionnaires. Subjective evaluation of vision in bright sunlight and when playing sport was significantly better with photochromic compared to clear lenses (p < 0.05). There were no significant differences between lens designs in subjective performance indoors, such as in the classroom or when reading (p > 0.05). Forty-three subjects (88 per cent) chose to continue wearing photochromic lenses on conclusion of the trial. Thirty subjects (61 per cent) preferred photochromic over clear lenses due to reasons such as darkening in sunlight, better vision and less squinting in sunlight. Forty-three parents (88 per cent) rated the children's overall experience with photochromic lenses to be favourable or very favourable. Photochromic lenses can be successfully prescribed for children and adolescents aged 10 to 15 years. Clear and photochromic lenses were considered to be equivalent for indoor activities; however, photochromic lenses were significantly preferred over clear lenses for outdoor activities. Likert grading scales can be used effectively in questionnaires for children and adolescents and further development of questionnaires for use in clinical trials evaluating lens performance in children is warranted.
- 1 July 2006
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 89 (4) , 246-252
Evaluation of the performance of photochromic spectacle lenses in children and adolescents aged 10 to 15 years
To compare the performance of clear and photochromic spectacle lenses in children and adolescents, with respect to visual acuity and satisfaction with day-to-day activities. Fifty full-time spectacle wearers, aged 10 to 15 years, were randomly assigned to wear clear and Transitions photochromic spectacle lenses for two weeks each in a crossover fashion. Subjects were evaluated at screening, lens delivery and two weeks post-delivery. At each visit, distance and near visual acuity (VA, logMAR) were assessed and subjective questionnaires, using Likert scales, were administered. Parents/guardians also completed questionnaires at entry and exit from the study. There were no significant differences in VA between clear and photochromic lenses (p > 0.05) and no difficulties were encountered with completion of the questionnaires. Subjective evaluation of vision in bright sunlight and when playing sport was significantly better with photochromic compared to clear lenses (p < 0.05). There were no significant differences between lens designs in subjective performance indoors, such as in the classroom or when reading (p > 0.05). Forty-three subjects (88 per cent) chose to continue wearing photochromic lenses on conclusion of the trial. Thirty subjects (61 per cent) preferred photochromic over clear lenses due to reasons such as darkening in sunlight, better vision and less squinting in sunlight. Forty-three parents (88 per cent) rated the children's overall experience with photochromic lenses to be favourable or very favourable. Photochromic lenses can be successfully prescribed for children and adolescents aged 10 to 15 years. Clear and photochromic lenses were considered to be equivalent for indoor activities; however, photochromic lenses were significantly preferred over clear lenses for outdoor activities. Likert grading scales can be used effectively in questionnaires for children and adolescents and further development of questionnaires for use in clinical trials evaluating lens performance in children is warranted.