Katrin Neumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katrin Neumann has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Harald A. Euler
Departments of Phoniatrics and Pediatric Audiology
6 shared publicationsChristine Preibisch
3 shared publicationsHeinrich Lanfermann
3 shared publicationsVolker Gall
Clinic of Phoniatry und Pedaudiology, University of Frankfurt/Main, Germany
3 shared publicationsAlexander Wolff von Gudenberg
Institute of the Kasseler Stottertherapie, Bad Emstal, Germany
2 shared publicationsAnne-Lise Giraud
2 shared publications
Latest Publications
- 24 October 2011
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (3) , 157-163
Speech audiometry in quiet with the Oldenburg Sentence Test for Children
Objective: To assess speech perception in children, speech audiometric sentence tests are generally better suited than single word tests because of their steeper discrimination function and thus higher sensitivity. A disadvantage of older German single word speech audiometric tests for children is their inapplicability in quiet and in noise. Moreover, their discrimination functions are shallower than those of optimized sentence tests, particularly in noise. The Oldenburg sentence test for children (Oldenburger Kinder-Satztest; OlKiSa) has already been shown to test reliably the speech perception in noise in normal-hearing children. Testing hearing-impaired children in noise, however, may be difficult. Therefore, quality criteria and norms for testing in quiet are also needed. Study sample: The OlKiSa in quiet was validated with 224 normal-hearing children between ages 4 to 10 years. Results: The discrimination functions are steeper (6.4 to 10.7 %/dB) than those of the commonly used German single word tests. Age-specific standards for 50% speech perception in quiet (speech reception threshold, SRT) are provided. Conclusions: The OlKiSa is a valid audiometric test to quantify speech perception in quiet in children from age 4.
- 24 October 2011
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (3) , 157-163
Speech audiometry in quiet with the Oldenburg Sentence Test for Children
Objective: To assess speech perception in children, speech audiometric sentence tests are generally better suited than single word tests because of their steeper discrimination function and thus higher sensitivity. A disadvantage of older German single word speech audiometric tests for children is their inapplicability in quiet and in noise. Moreover, their discrimination functions are shallower than those of optimized sentence tests, particularly in noise. The Oldenburg sentence test for children (Oldenburger Kinder-Satztest; OlKiSa) has already been shown to test reliably the speech perception in noise in normal-hearing children. Testing hearing-impaired children in noise, however, may be difficult. Therefore, quality criteria and norms for testing in quiet are also needed. Study sample: The OlKiSa in quiet was validated with 224 normal-hearing children between ages 4 to 10 years. Results: The discrimination functions are steeper (6.4 to 10.7 %/dB) than those of the commonly used German single word tests. Age-specific standards for 50% speech perception in quiet (speech reception threshold, SRT) are provided. Conclusions: The OlKiSa is a valid audiometric test to quantify speech perception in quiet in children from age 4.
- 10 August 2010
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 63 (1) , 43-48
Definitions of Types of Hearing Impairment: A Discussion Paper
Objective: To develop a clear and meaningful set of definitions of types of hearing impairment. Method: A critical analysis was made of previous definitions together with a consideration of current knowledge of functions and dysfunctions of the auditory system. Results and Conclusions: A coherent set of definitions compatible with the contemporary understanding of auditory disorders and their perceptual effects is proposed.
- 10 August 2010
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 63 (1) , 43-48
Definitions of Types of Hearing Impairment: A Discussion Paper
Objective: To develop a clear and meaningful set of definitions of types of hearing impairment. Method: A critical analysis was made of previous definitions together with a consideration of current knowledge of functions and dysfunctions of the auditory system. Results and Conclusions: A coherent set of definitions compatible with the contemporary understanding of auditory disorders and their perceptual effects is proposed.
- 1 March 2009
- Vol. 15 (3) , MT41-6
Computer-assisted documentation of the fiberoptic endoscopic evaluation of swallowing.
Because documentation and report writing in fiberoptic endoscopic evaluation of swallowing (FEES) is time consuming and susceptible to omissions, a software solution to ameliorate these problems by maintaining document quality is desirable. Based on the FEES procedure of Langmore, a documentation software (DS) which presents a digitized FEES recording and masks with precast text fields was designed to facilitate and unify data input. The oropharyngeal secretion scale of Murray and the penetration-aspiration scale of Rosenbek were integrated to increase comparability of dysphagia information. Four independent examiners analyzed 12 digitized FEES-recordings, 6 without and 6 with the DS, to determine its effect on the times needed for total evaluation, interpretation, documentation, report writing, and report completeness. The documentation software (DS) reduced the total evaluation time from 42 min to 18 min and increased the evaluation completeness from 55% to 95%, both with very large effect sizes. The time saving was mainly due to an automated report generation at the end of the analysis. The DS can be offered as a valuable and effective tool in daily clinical routine and for research purposes.
- 1 March 2009
- Vol. 15 (3) , MT41-6
Computer-assisted documentation of the fiberoptic endoscopic evaluation of swallowing.
Because documentation and report writing in fiberoptic endoscopic evaluation of swallowing (FEES) is time consuming and susceptible to omissions, a software solution to ameliorate these problems by maintaining document quality is desirable. Based on the FEES procedure of Langmore, a documentation software (DS) which presents a digitized FEES recording and masks with precast text fields was designed to facilitate and unify data input. The oropharyngeal secretion scale of Murray and the penetration-aspiration scale of Rosenbek were integrated to increase comparability of dysphagia information. Four independent examiners analyzed 12 digitized FEES-recordings, 6 without and 6 with the DS, to determine its effect on the times needed for total evaluation, interpretation, documentation, report writing, and report completeness. The documentation software (DS) reduced the total evaluation time from 42 min to 18 min and increased the evaluation completeness from 55% to 95%, both with very large effect sizes. The time saving was mainly due to an automated report generation at the end of the analysis. The DS can be offered as a valuable and effective tool in daily clinical routine and for research purposes.
- 16 January 2009
- Published by Springer Nature in HNO
- Vol. 57 (1) , 17-20
Qualitätssicherung eines universellen Neugeborenen-Hörscreenings
Die gesetzlich verankerte Einführung eines universellen Neugeborenen-Hörscreenings erfordert eine fortlaufende Qualitätssicherung. Die Mitglieder der Deutschen Gesellschaft für Phoniatrie und Pädaudiologie haben daher auf ihrer Jahrestagung 2007 eine Empfehlung über screeningbegleitende qualitätssichernde Maßnahmen beschlossen. Diese Empfehlung betrifft Art, Durchführung, Ort, Zeitrahmen und technische Voraussetzungen des Screenings sowie ggf. notwendiger Nachfolgeuntersuchungen, weiterhin die Definition eines durch das Screening zu detektierenden Hörverlusts, durchführende und verantwortliche Berufsgruppen und deren Qualifikation für das Screening, die Regelung von Re- und Kontroll-Screenings, Konfirmationsdiagnostik und Therapieeinleitung, die Information der Eltern, die Dokumentation der Screening-Ergebnisse, Ziele und Organisation des Trackings, die Aufgaben von regionalen Screening-Leitstellen und einer überregionalen Qualitätssicherungsinstitution des Hörscreenings, die Erfassung personen- und screeningbezogener qualitätsrelevanter Daten und die Verfügbarkeit definierter Datensätze als Grundlage für Kostenanalysen und Qualitätsberichte. Statutory implementation of a universal newborn hearing screening requires a continuous quality assurance monitoring. Therefore, at the Annual Meeting in 2007, the members of the German Society of Phoniatrics and Pediatric Audiology passed a recommendation on measures of quality assurance applied to newborn hearing screening. This recommendation describes the procedures, performance, location, time frame, and technical prerequisites of the screening and of potentially necessary follow-ups, the definition of hearing loss to be detected, the performing and responsible professional groups and their qualifications for the screening, the regulation of repeat and control screenings, the confirmation diagnostics and initiation of therapy, the information of parents, the documentation of screening results, the aims and organization of a tracking system, the tasks of regional screening centers and of a supraregional institution for the quality assurance of the hearing screening, the central collection of person and screening-related quality relevant data, and the accessibility of defined data sets as predisposition for cost analyses and quality reports.
- 16 January 2009
- Published by Springer Nature in HNO
- Vol. 57 (1) , 17-20
Qualitätssicherung eines universellen Neugeborenen-Hörscreenings
Die gesetzlich verankerte Einführung eines universellen Neugeborenen-Hörscreenings erfordert eine fortlaufende Qualitätssicherung. Die Mitglieder der Deutschen Gesellschaft für Phoniatrie und Pädaudiologie haben daher auf ihrer Jahrestagung 2007 eine Empfehlung über screeningbegleitende qualitätssichernde Maßnahmen beschlossen. Diese Empfehlung betrifft Art, Durchführung, Ort, Zeitrahmen und technische Voraussetzungen des Screenings sowie ggf. notwendiger Nachfolgeuntersuchungen, weiterhin die Definition eines durch das Screening zu detektierenden Hörverlusts, durchführende und verantwortliche Berufsgruppen und deren Qualifikation für das Screening, die Regelung von Re- und Kontroll-Screenings, Konfirmationsdiagnostik und Therapieeinleitung, die Information der Eltern, die Dokumentation der Screening-Ergebnisse, Ziele und Organisation des Trackings, die Aufgaben von regionalen Screening-Leitstellen und einer überregionalen Qualitätssicherungsinstitution des Hörscreenings, die Erfassung personen- und screeningbezogener qualitätsrelevanter Daten und die Verfügbarkeit definierter Datensätze als Grundlage für Kostenanalysen und Qualitätsberichte. Statutory implementation of a universal newborn hearing screening requires a continuous quality assurance monitoring. Therefore, at the Annual Meeting in 2007, the members of the German Society of Phoniatrics and Pediatric Audiology passed a recommendation on measures of quality assurance applied to newborn hearing screening. This recommendation describes the procedures, performance, location, time frame, and technical prerequisites of the screening and of potentially necessary follow-ups, the definition of hearing loss to be detected, the performing and responsible professional groups and their qualifications for the screening, the regulation of repeat and control screenings, the confirmation diagnostics and initiation of therapy, the information of parents, the documentation of screening results, the aims and organization of a tracking system, the tasks of regional screening centers and of a supraregional institution for the quality assurance of the hearing screening, the central collection of person and screening-related quality relevant data, and the accessibility of defined data sets as predisposition for cost analyses and quality reports.
- 7 April 2008
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 13 (5) , 281-292
Testing the Diagnostic Value of Electrical Ear Canal Stimulation in Cochlear Implant Candidates by Functional Magnetic Resonance Imaging
Prior to cochlear implant (CI) surgery in children, the integrity of the auditory pathway is sometimes assessed by electrical ear canal stimulation (ECS). However, the evaluation of reactions as auditory is subjective. To test the prognostic value of ECS, functional magnetic resonance imaging (fMRI) was performed during ECS vicariously in 18 adult CI candidates. Activation of the primary auditory cortex was detected in 9 of 16 cases when auditory sensations during ECS occurred, and tended to be more bilaterally distributed in CI candidates than in normal-hearing controls. ECS sensations only tended to correlate with fMRI activations. However, solely frequency discrimination during electrical stimulation predicted CI outcome, but neither other auditory sensations nor fMRI activations did so satisfactorily, which limits the diagnostic value of these measures. Instead, preoperative residual hearing (nonamplified and amplified) was a robust predictor for CI benefit.
- 7 April 2008
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 13 (5) , 281-292
Testing the Diagnostic Value of Electrical Ear Canal Stimulation in Cochlear Implant Candidates by Functional Magnetic Resonance Imaging
Prior to cochlear implant (CI) surgery in children, the integrity of the auditory pathway is sometimes assessed by electrical ear canal stimulation (ECS). However, the evaluation of reactions as auditory is subjective. To test the prognostic value of ECS, functional magnetic resonance imaging (fMRI) was performed during ECS vicariously in 18 adult CI candidates. Activation of the primary auditory cortex was detected in 9 of 16 cases when auditory sensations during ECS occurred, and tended to be more bilaterally distributed in CI candidates than in normal-hearing controls. ECS sensations only tended to correlate with fMRI activations. However, solely frequency discrimination during electrical stimulation predicted CI outcome, but neither other auditory sensations nor fMRI activations did so satisfactorily, which limits the diagnostic value of these measures. Instead, preoperative residual hearing (nonamplified and amplified) was a robust predictor for CI benefit.
- Open Access
- 6 December 2007
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 60 (1) , 1-3
The New Audiology Committee of the IALP Cooperates with the WHO in the Global Work on Problems of Hearing-Impaired People
- 6 December 2007
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 60 (1) , 1-3
Open AccessThe New Audiology Committee of the IALP Cooperates with the WHO in the Global Work on Problems of Hearing-Impaired People
- 1 January 2007
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 46 (8) , 407-418
TEOAE amplitude growth, detectability, and response threshold in linear and nonlinear mode and in different time windows
Transitory evoked otoacoustic emissions (TEOAE) have been recorded in 60 ears of 31 adult volunteers with nearly normal hearing at stimulus levels ranging from 83 dB SPL peak equivalent down to the individual response threshold using linear and nonlinear recording mode. The stimulus level dependence of response incidence and amplitude has been analysed for the integral response and in time windows selecting response components of limited latency ranges. At stimulus levels above 70 dB SPL peak equivalent the TEOAE records received in linear mode are contaminated with stimulus artifacts. At moderate stimulus levels the TEOAE amplitude differs only to a small extent between the two recording modes. At low levels the linear mode turns out to be better suited for signal detection due to its inherent lower noise level. The response threshold, defined as the highest stimulus level yielding a reproducibility of at least 60%, is significantly correlated to hearing threshold. The consideration of time windowed responses yields best results with respect to incidence and threshold of responses in the latency range between 5 and 10 ms, but it does not enhance frequency specificity.
- 1 January 2007
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 46 (8) , 407-418
TEOAE amplitude growth, detectability, and response threshold in linear and nonlinear mode and in different time windows
Transitory evoked otoacoustic emissions (TEOAE) have been recorded in 60 ears of 31 adult volunteers with nearly normal hearing at stimulus levels ranging from 83 dB SPL peak equivalent down to the individual response threshold using linear and nonlinear recording mode. The stimulus level dependence of response incidence and amplitude has been analysed for the integral response and in time windows selecting response components of limited latency ranges. At stimulus levels above 70 dB SPL peak equivalent the TEOAE records received in linear mode are contaminated with stimulus artifacts. At moderate stimulus levels the TEOAE amplitude differs only to a small extent between the two recording modes. At low levels the linear mode turns out to be better suited for signal detection due to its inherent lower noise level. The response threshold, defined as the highest stimulus level yielding a reproducibility of at least 60%, is significantly correlated to hearing threshold. The consideration of time windowed responses yields best results with respect to incidence and threshold of responses in the latency range between 5 and 10 ms, but it does not enhance frequency specificity.
- 1 November 2006
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 58 (6) , 440-455
Effectiveness and Efficiency of a Universal Newborn Hearing Screening in Germany
The decision to mandate, finance, and implement a universal newborn hearing screening (UNHS) requires the evaluation of its therapy-directed benefit by comparing (1) a procedure employing a UNHS with (2) a targeted screening for at-risk babies for neonatal hearing disorders and (3) a procedure without systematic screening. In a cohort study the outcome of the UNHS program of Hessen in 2005 with 17,439 screened newborns was analyzed. Validity, effectiveness, and efficiency were evaluated and compared to a sample of 98 Hessian and 355 German children who were detected in 2005 as hearing-impaired but not by an UNHS. The UNHS group had a PASS rate of 97.0%. Forty-nine hearing-impaired children were diagnosed at a median age of 3.1 months and treated at a median age of 3.5 months. Corresponding values for the Hessian non-UNHS group were 17.8 and 21.0 months. For Germany the median age at diagnosis was 39.0 months. The age at therapy onset correlated negatively with parameters of speech/language and psychosocial development. A targeted screening would have resulted in a low sensitivity of 65.3%. Hence, a UNHS is the most effective way to an early therapy of neonatal hearing disorders with an optimal outcome.
- 1 November 2006
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 58 (6) , 440-455
Effectiveness and Efficiency of a Universal Newborn Hearing Screening in Germany
The decision to mandate, finance, and implement a universal newborn hearing screening (UNHS) requires the evaluation of its therapy-directed benefit by comparing (1) a procedure employing a UNHS with (2) a targeted screening for at-risk babies for neonatal hearing disorders and (3) a procedure without systematic screening. In a cohort study the outcome of the UNHS program of Hessen in 2005 with 17,439 screened newborns was analyzed. Validity, effectiveness, and efficiency were evaluated and compared to a sample of 98 Hessian and 355 German children who were detected in 2005 as hearing-impaired but not by an UNHS. The UNHS group had a PASS rate of 97.0%. Forty-nine hearing-impaired children were diagnosed at a median age of 3.1 months and treated at a median age of 3.5 months. Corresponding values for the Hessian non-UNHS group were 17.8 and 21.0 months. For Germany the median age at diagnosis was 39.0 months. The age at therapy onset correlated negatively with parameters of speech/language and psychosocial development. A targeted screening would have resulted in a low sensitivity of 65.3%. Hence, a UNHS is the most effective way to an early therapy of neonatal hearing disorders with an optimal outcome.
- 1 January 2006
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 45 (2) , 83-90
Auditory status of persons with intellectual disability at the German Special Olympic Games
Among persons with intellectual disability, the prevalence of hearing impairments is high. During the German Special Olympics Summer Games 2004, a hearing screening was conducted on 755 athletes with intellectual disabilities. Obligatory screening included ear inspection and recording of otoacoustic emissions, and optional screening included tympanometry and brief pure-tone audiometry. 38.0% of the athletes failed the screening. 53.0% needed ear wax removal. 56.1% of the fails indicated sensorineural hearing loss and 13.6% indicated mixed hearing loss. 12.5% of the fails were caused by unremovable ear wax, 1.4% by ear canal affections, and 16.4% by middle ear problems. Left ear fails were more frequent than right ear fails. A peripheral hearing disturbance can thus be expected in every third subject. The high failure rate, a considerable percentage of previously undetected profound hearing loss (1.1%), and the frequent need for ear wax removal, suggest that nearly half of persons with intellectual disabilities need regular otological or audiological consultations. Sumario La prevalencia de hipoacusia entre personas con discapacidad auditiva, es alta. Durante los juegos olímpicos de verano 2004 en Alemania, se realizó un tamiz auditivo en 755 atletas con discapacidad intelectual. Éste incluyó otoscopia, prueba de emisiones otoacústicas y opcionalmente una timpanometría y una audiometría breve. El 38% de los atletas no pasaron el tamiz y a 53% se les retiró cerumen. El 56.1% de los que no pasaron el tamiz presentaban hipoacusia sensorineural y 13% hipoacusia mixta; a 12.5% no fue posible retirarles el cerumen, 1.4% presentaban alteraciones del conducto auditivo externo y 16.4% tenían algún problema del oído medio. Fueron más frecuentes las alteraciones en el oído izquierdo que en el derecho. Se puede esperar una alteración auditiva periférica en un tercio de los sujetos. El alto índice de falla en el tamiz, un porcentaje considerable de hipoacusia profunda no detectada (1.1%) y la necesidad frecuente de remoción de cerumen, sugiere que casi la mitad de las personas con discapacidad intelectual necesitan consulta audiológica u otológica regular.
- 1 January 2006
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 45 (2) , 83-90
Auditory status of persons with intellectual disability at the German Special Olympic Games
Among persons with intellectual disability, the prevalence of hearing impairments is high. During the German Special Olympics Summer Games 2004, a hearing screening was conducted on 755 athletes with intellectual disabilities. Obligatory screening included ear inspection and recording of otoacoustic emissions, and optional screening included tympanometry and brief pure-tone audiometry. 38.0% of the athletes failed the screening. 53.0% needed ear wax removal. 56.1% of the fails indicated sensorineural hearing loss and 13.6% indicated mixed hearing loss. 12.5% of the fails were caused by unremovable ear wax, 1.4% by ear canal affections, and 16.4% by middle ear problems. Left ear fails were more frequent than right ear fails. A peripheral hearing disturbance can thus be expected in every third subject. The high failure rate, a considerable percentage of previously undetected profound hearing loss (1.1%), and the frequent need for ear wax removal, suggest that nearly half of persons with intellectual disabilities need regular otological or audiological consultations. Sumario La prevalencia de hipoacusia entre personas con discapacidad auditiva, es alta. Durante los juegos olímpicos de verano 2004 en Alemania, se realizó un tamiz auditivo en 755 atletas con discapacidad intelectual. Éste incluyó otoscopia, prueba de emisiones otoacústicas y opcionalmente una timpanometría y una audiometría breve. El 38% de los atletas no pasaron el tamiz y a 53% se les retiró cerumen. El 56.1% de los que no pasaron el tamiz presentaban hipoacusia sensorineural y 13% hipoacusia mixta; a 12.5% no fue posible retirarles el cerumen, 1.4% presentaban alteraciones del conducto auditivo externo y 16.4% tenían algún problema del oído medio. Fueron más frecuentes las alteraciones en el oído izquierdo que en el derecho. Se puede esperar una alteración auditiva periférica en un tercio de los sujetos. El alto índice de falla en el tamiz, un porcentaje considerable de hipoacusia profunda no detectada (1.1%) y la necesidad frecuente de remoción de cerumen, sugiere que casi la mitad de las personas con discapacidad intelectual necesitan consulta audiológica u otológica regular.
- 6 October 2005
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 57 (5-6) , 308-327
The Interplay between Glottis and Vocal Tract during the Male Passaggio
The transition between ‘chest’ and ‘head’ register is essential for male opera singers in order to reach the higher pitches. The ‘passaggio’, which is a scale passage where this transition takes place, but also a maneuver of register equalization, is typically difficult to learn. Studies on parameters for a definition of this transition are restricted to a small number of singers so far. Audio, electroglottographic, and equivalent subglottic pressure signals of 11 male opera singers were recorded while singing scales on open back vowels and passing the register transition. A spectrum analysis of the audio signal revealed that the second harmonic (H2) dominates in ‘chest’, resonated by the first formant (F1), together with the fourth harmonic (H4), supported by the second formant (F2). During the passaggio, H2 level decreases because it loses the resonance of F1, while the third harmonic (H3) gains the resonance of F2. At this point the H4 level drops because that harmonic is no longer supported by F2. The transition from ‘chest’ to ‘head’ register is marked by characteristic changes in the amplitude patterns of the partials H2, H3, and H4, and the frequency progressions of the first two formants, defining an objective distinction between the two registers.
- 6 October 2005
- Published by S. Karger AG in Folia Phoniatrica et Logopaedica
- Vol. 57 (5-6) , 308-327
The Interplay between Glottis and Vocal Tract during the Male Passaggio
The transition between ‘chest’ and ‘head’ register is essential for male opera singers in order to reach the higher pitches. The ‘passaggio’, which is a scale passage where this transition takes place, but also a maneuver of register equalization, is typically difficult to learn. Studies on parameters for a definition of this transition are restricted to a small number of singers so far. Audio, electroglottographic, and equivalent subglottic pressure signals of 11 male opera singers were recorded while singing scales on open back vowels and passing the register transition. A spectrum analysis of the audio signal revealed that the second harmonic (H2) dominates in ‘chest’, resonated by the first formant (F1), together with the fourth harmonic (H4), supported by the second formant (F2). During the passaggio, H2 level decreases because it loses the resonance of F1, while the third harmonic (H3) gains the resonance of F2. At this point the H4 level drops because that harmonic is no longer supported by F2. The transition from ‘chest’ to ‘head’ register is marked by characteristic changes in the amplitude patterns of the partials H2, H3, and H4, and the frequency progressions of the first two formants, defining an objective distinction between the two registers.