Tomonari Umemura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomonari Umemura has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Hiroki Haraguchi
Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
2 shared publicationsKin-Ichi Tsunoda
Department of Chemistry, Faculty of Engineering, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan
2 shared publications- Akhmad Sabarudin
Department of Chemistry, Faculty of Science, Brawijaya University, Malang, Indonesia
1 shared publication Akio Katakai
Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research Institute, Gunma, Japan
1 shared publication- Hirofumi Noguchi
Department of Regenerative Medicine, Graduate School of Medicine, University of the Ryukyus, Okinawa 903-0215, Japan
1 shared publication - Hiroki Hotta
Graduate School of Maritime Sciences Kobe University Kobe Hyogo Japan
1 shared publication
Latest Publications
- 13 October 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (21) , 8252-8258
Estimation of the Distribution of Intravenously Injected Adipose Tissue-Derived Stem Cells Labeled with Quantum Dots in Mice Organs through the Determination of their Metallic Components by ICPMS
Adipose tissue-derived stem cells (ASCs) have shown promise in cell therapy because of their ability to self-renew damaged or diseased organs and easy harvest. To ensure the distribution and quantification of the ASCs injected from tail vein, several whole-body imaging techniques including fluorescence optical imaging with quantum dots (QDs) have been employed, but they may suffer from insufficient sensitivity and accuracy. Here, we report quantitative distribution of ASCs in various organs (heart, lung, liver, spleen, and kidney) of mice, which were intravenously injected with QDs-labeled ASCs (QDs-ASCs), through the detection of QDs-derived metallic components by inductively coupled plasma mass spectrometry (ICPMS). For accurate and precise determination, each organ was harvested and completely digested with a mixture of HNO3 and H2O2 in a microwave oven prior to ICPMS measurement, which was equipped with a microflow injection system and a laboratory-made capillary-attached micronebulizer. After optimization, 16 elements including major components (Cd, Se, and Te) of QDs and essential elements (Na, K, Mg, Ca, P, S, Mn, Fe, Co, Cu, Zn, Se, Sr, and Mo) were successfully determined in the organs. As compared to untreated mice, QDs-ASCs-treated mice showed significantly higher levels of Cd and Te in all organs, and as expected, the molar ratio of Cd to Te in each organ was in good agreement with the molar composition ratio in the QDs. This result indicates that the increment of Cd (or Te) can be used as a tracer for calculating the distribution of ASCs in mice organs. As a result of the calculation, 36.8%, 19.1%, 0.59%, 0.49%, and 0.25% of the total ASCs injected were estimated to be distributed in the liver, lung, heart, spleen, and kidney, respectively.
- 13 October 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (21) , 8252-8258
Estimation of the Distribution of Intravenously Injected Adipose Tissue-Derived Stem Cells Labeled with Quantum Dots in Mice Organs through the Determination of their Metallic Components by ICPMS
Adipose tissue-derived stem cells (ASCs) have shown promise in cell therapy because of their ability to self-renew damaged or diseased organs and easy harvest. To ensure the distribution and quantification of the ASCs injected from tail vein, several whole-body imaging techniques including fluorescence optical imaging with quantum dots (QDs) have been employed, but they may suffer from insufficient sensitivity and accuracy. Here, we report quantitative distribution of ASCs in various organs (heart, lung, liver, spleen, and kidney) of mice, which were intravenously injected with QDs-labeled ASCs (QDs-ASCs), through the detection of QDs-derived metallic components by inductively coupled plasma mass spectrometry (ICPMS). For accurate and precise determination, each organ was harvested and completely digested with a mixture of HNO3 and H2O2 in a microwave oven prior to ICPMS measurement, which was equipped with a microflow injection system and a laboratory-made capillary-attached micronebulizer. After optimization, 16 elements including major components (Cd, Se, and Te) of QDs and essential elements (Na, K, Mg, Ca, P, S, Mn, Fe, Co, Cu, Zn, Se, Sr, and Mo) were successfully determined in the organs. As compared to untreated mice, QDs-ASCs-treated mice showed significantly higher levels of Cd and Te in all organs, and as expected, the molar ratio of Cd to Te in each organ was in good agreement with the molar composition ratio in the QDs. This result indicates that the increment of Cd (or Te) can be used as a tracer for calculating the distribution of ASCs in mice organs. As a result of the calculation, 36.8%, 19.1%, 0.59%, 0.49%, and 0.25% of the total ASCs injected were estimated to be distributed in the liver, lung, heart, spleen, and kidney, respectively.
- 29 September 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (21) , 7511-7516
Slab Optical Waveguide High-Acidity Sensor Based on an Absorbance Change of Protoporphyrin IX
A sensitive and fast-responsive evanescent wave absorption sensor has been constructed for pH measurements in highly acidic ranges. This sensor is based on a pH-dependent color change of protoporphyrin IX (PPIX). For the sensitive detection, a visible attenuated total reflection spectrometer with a slab optical waveguide (SOWG) was laboratory-made, and the guiding layer surface was modified with a PPIX-immobilized acrylamide-based thin membrane. The sensing membrane with a thickness of approximately 1 mum was directly fabricated on the SOWG glass surface by copolymerization of acrylamide, N,N'-methylene bisacrylamide, and PPIX in the narrow space confined by a cover plate. PPIX possesses two double bonds in its structure, and so it can be covalently incorporated into the membrane. The response characteristics of the PPIX-immobilized optode membrane were explored using aqueous solutions with different concentrations of HNO(3) or HCl. The optode membrane provided characteristic Soret band absorption spectra depending on the hydrogen ion concentration; the absorbance at 410 nm increased with increasing the concentrations in the range of 0.15-2 M, corresponding to the range of pH -0.3 to 0.8. The absorption signal reached 90% of its final value within 10 s, while the absorption signal was quite readily returned to background level simply by passing 2 mL of distilled water through a flow cell with a volume of 16.5 muL placed on the SOWG. Due to the rapid response and reversibility, this sensor could be operated in a flow-through mode as well as in a conventional static mode, where deionized water was conveniently used as a carrier and conditioning solution. In terms of the stability and precision, this sensor showed no significant change in response even after 100 assays and after being stored in a dry condition for over 6 months. Relative standard deviations for 10 replicate measurements were less than 1.8% in the linear range, and the detection limit calculated from 3 times of the standard deviation was 0.02 pH unit.
- 29 September 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (21) , 7511-7516
Slab Optical Waveguide High-Acidity Sensor Based on an Absorbance Change of Protoporphyrin IX
A sensitive and fast-responsive evanescent wave absorption sensor has been constructed for pH measurements in highly acidic ranges. This sensor is based on a pH-dependent color change of protoporphyrin IX (PPIX). For the sensitive detection, a visible attenuated total reflection spectrometer with a slab optical waveguide (SOWG) was laboratory-made, and the guiding layer surface was modified with a PPIX-immobilized acrylamide-based thin membrane. The sensing membrane with a thickness of approximately 1 mum was directly fabricated on the SOWG glass surface by copolymerization of acrylamide, N,N'-methylene bisacrylamide, and PPIX in the narrow space confined by a cover plate. PPIX possesses two double bonds in its structure, and so it can be covalently incorporated into the membrane. The response characteristics of the PPIX-immobilized optode membrane were explored using aqueous solutions with different concentrations of HNO(3) or HCl. The optode membrane provided characteristic Soret band absorption spectra depending on the hydrogen ion concentration; the absorbance at 410 nm increased with increasing the concentrations in the range of 0.15-2 M, corresponding to the range of pH -0.3 to 0.8. The absorption signal reached 90% of its final value within 10 s, while the absorption signal was quite readily returned to background level simply by passing 2 mL of distilled water through a flow cell with a volume of 16.5 muL placed on the SOWG. Due to the rapid response and reversibility, this sensor could be operated in a flow-through mode as well as in a conventional static mode, where deionized water was conveniently used as a carrier and conditioning solution. In terms of the stability and precision, this sensor showed no significant change in response even after 100 assays and after being stored in a dry condition for over 6 months. Relative standard deviations for 10 replicate measurements were less than 1.8% in the linear range, and the detection limit calculated from 3 times of the standard deviation was 0.02 pH unit.
- 10 May 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 386 (3) , 566-571
Preparation and characterization of methacrylate-based semi-micro monoliths for high-throughput bioanalysis
Hexyl methacrylate (HMA)-based monolithic semi-micro columns were prepared by in situ polymerization within the confines of 1.02-mm-i.d. silicosteel tubing for reversed-phase and/or precipitation–redissolution liquid chromatography. Practically useful monolithic columns with adequate separation efficiency, high permeability, and good mechanical strength were successfully obtained using a polymerization mixture comprising 24% hexyl methacrylate (HMA), 6% ethylene dimethacrylate (EDMA), 44.5% 1-propanol, and 25.5% 1,4-butanediol. The column performance was evaluated through the separations of a series of alkylbenzenes. At a normal flow rate of 50 μL min−1, the produced HMA-based monolithic columns typically exhibited 3,000 theoretical plates for a 20-cm-long column, and the pressure drop was generally less than 1 MPa per 20 cm. The monolithic columns were resistant to at least 15 MPa, and could be properly operated at 15–20 times higher flow rate than normal, reducing the separation time to 1/15–1/20. The HMA-based monolithic columns were applied to rapid and efficient separations of proteins such as ribonuclease A, cytochrome c, transferrin, and ovalbumin in the precipitation–redissolution mode. Using a CH3CN gradient elution at a flow rate of 1,000 μL min−1, four proteins were baseline separated within 20 s.
- 10 May 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 386 (3) , 566-571
Preparation and characterization of methacrylate-based semi-micro monoliths for high-throughput bioanalysis
Hexyl methacrylate (HMA)-based monolithic semi-micro columns were prepared by in situ polymerization within the confines of 1.02-mm-i.d. silicosteel tubing for reversed-phase and/or precipitation–redissolution liquid chromatography. Practically useful monolithic columns with adequate separation efficiency, high permeability, and good mechanical strength were successfully obtained using a polymerization mixture comprising 24% hexyl methacrylate (HMA), 6% ethylene dimethacrylate (EDMA), 44.5% 1-propanol, and 25.5% 1,4-butanediol. The column performance was evaluated through the separations of a series of alkylbenzenes. At a normal flow rate of 50 μL min−1, the produced HMA-based monolithic columns typically exhibited 3,000 theoretical plates for a 20-cm-long column, and the pressure drop was generally less than 1 MPa per 20 cm. The monolithic columns were resistant to at least 15 MPa, and could be properly operated at 15–20 times higher flow rate than normal, reducing the separation time to 1/15–1/20. The HMA-based monolithic columns were applied to rapid and efficient separations of proteins such as ribonuclease A, cytochrome c, transferrin, and ovalbumin in the precipitation–redissolution mode. Using a CH3CN gradient elution at a flow rate of 1,000 μL min−1, four proteins were baseline separated within 20 s.