Horst Urbach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Horst Urbach has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
Johannes Schramm
University of Bonn Medical Center
5 shared publications- Christian G. Bien
Department of Epileptology, Krankenhaus Mara, Bethel Epilepsy Center, Medical School OWL, Bielefeld University, Germany
4 shared publications Ingmar Blümcke
4 shared publications- Joachim Von Oertzen
Johannes Kepler University Linz, Kepler University Hospital, Department of Neurology, Austria (T.J.O., J.N.W., M.W.).
4 shared publications Albert Becker
3 shared publicationsRoy Koenig
Radiology
3 shared publications
Latest Publications
- 31 May 2012
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 22 (2) , 173-189
High-Field Magnetic Resonance Imaging for Epilepsy
- 31 May 2012
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 22 (2) , 173-189
High-Field Magnetic Resonance Imaging for Epilepsy
- 4 December 2010
- Published by Springer Nature in Journal of Neurology
- Vol. 258 (5) , 935-937
MS-like presentation of Alexander disease with multifocal lesions and oligoclonal bands
- 4 December 2010
- Published by Springer Nature in Journal of Neurology
- Vol. 258 (5) , 935-937
MS-like presentation of Alexander disease with multifocal lesions and oligoclonal bands
- 30 March 2010
- Published by Taylor & Francis in Blood Pressure
- Vol. 19 (4) , 267-269
Reversible multifocal leukoencephalopathy associated with a nocturnal blood pressure non-dipper pattern
The majority of cases of leukoencephalopathy related to hypertensive crisis show brain lesions predominantly in the posterior lobe. Such cases are usually classified as reversible posterior leukoencephalopathy syndrome (RPLS). A multifocal distribution pattern is also possible, but occurs seldom. Here we report two patients with extensive white matter lesions that affect the entire brain, related to hypertensive crisis associated with a non-dipper pattern of blood pressure during the night as well as renal dysfunction. This nocturnal blood pressure abnormality may be relevant for the distribution pattern of cerebral white matter lesions and underlines the concept that in these cases a 24-h ambulatory blood pressure monitoring is needed.
- 30 March 2010
- Published by Taylor & Francis in Blood Pressure
- Vol. 19 (4) , 267-269
Reversible multifocal leukoencephalopathy associated with a nocturnal blood pressure non-dipper pattern
The majority of cases of leukoencephalopathy related to hypertensive crisis show brain lesions predominantly in the posterior lobe. Such cases are usually classified as reversible posterior leukoencephalopathy syndrome (RPLS). A multifocal distribution pattern is also possible, but occurs seldom. Here we report two patients with extensive white matter lesions that affect the entire brain, related to hypertensive crisis associated with a non-dipper pattern of blood pressure during the night as well as renal dysfunction. This nocturnal blood pressure abnormality may be relevant for the distribution pattern of cerebral white matter lesions and underlines the concept that in these cases a 24-h ambulatory blood pressure monitoring is needed.
- Open Access
- 27 August 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (1) , 100-105
Postsurgical Intracranial Hypotension: Diagnostic and Prognostic Imaging Findings
BACKGROUND AND PURPOSE: CSF loss with consecutive intracranial hypotension has been discussed as a possible pathogenetic mechanism in poor clinical outcome after uneventful neurosurgery and appears to be correlated to specific imaging findings. The purpose of this study was to describe the clinical and imaging findings of symptomatic intracranial hypotension likely induced by wound suction drainage. MATERIALS AND METHODS: This is a review of previously published cases of patients in whom this condition developed after uneventful intracranial surgery. We performed an analysis of 3 more cases, of which 2 occurred after spinal surgery with accidental dural opening. RESULTS: Sixteen patients who remained unconscious or did not become fully responsive after surgery showed symmetric bilateral thalamic/basal ganglia signal intensity changes on CT and MR imaging studies. Of these 16 patients, 4 died and 2 also had brain stem signal intensity changes. All patients had rapid and distinct intraoperative and postoperative CSF loss documented on CT and/or MR imaging studies by a transient increase of the sag ratio, defined as maximal anteroposterior midbrain diameter by maximal bipeduncular diameter. CONCLUSIONS: The clinical course and typical MR imaging findings characterize the disease entity postsurgical intracranial hypotension. These findings also underline the potential danger of wound suction drainage in the case of possible CSF loss.
- 27 August 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (1) , 100-105
Open AccessPostsurgical Intracranial Hypotension: Diagnostic and Prognostic Imaging Findings
BACKGROUND AND PURPOSE: CSF loss with consecutive intracranial hypotension has been discussed as a possible pathogenetic mechanism in poor clinical outcome after uneventful neurosurgery and appears to be correlated to specific imaging findings. The purpose of this study was to describe the clinical and imaging findings of symptomatic intracranial hypotension likely induced by wound suction drainage. MATERIALS AND METHODS: This is a review of previously published cases of patients in whom this condition developed after uneventful intracranial surgery. We performed an analysis of 3 more cases, of which 2 occurred after spinal surgery with accidental dural opening. RESULTS: Sixteen patients who remained unconscious or did not become fully responsive after surgery showed symmetric bilateral thalamic/basal ganglia signal intensity changes on CT and MR imaging studies. Of these 16 patients, 4 died and 2 also had brain stem signal intensity changes. All patients had rapid and distinct intraoperative and postoperative CSF loss documented on CT and/or MR imaging studies by a transient increase of the sag ratio, defined as maximal anteroposterior midbrain diameter by maximal bipeduncular diameter. CONCLUSIONS: The clinical course and typical MR imaging findings characterize the disease entity postsurgical intracranial hypotension. These findings also underline the potential danger of wound suction drainage in the case of possible CSF loss.
- 23 August 2009
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 19 (3) , 197-203
The Enterprise Stent for the Treatment of Intracranial Aneurysms
Self-expanding microstents are typically placed before a wide-necked aneurysm is filled with coils. Alternatively, the stent may be placed at the end of the procedure, when the coil mass blocks or slows down the flow in the parent artery or a branching vessel. Between March 2007 and 2009, 20 aneurysms in 20 patients were treated with a total of 21 Enterprise stents. Nine aneurysms had reopened after coiling, eleven aneurysms were primarily treated, seven after acute subarachnoid hemorrhage. Eight aneurysms were primarily filled with coils and the stent was placed when the flow in the parent or a branching artery was blocked or slowed down. In four of these cases in which secondary stenting was considered an option in advance, the “artery at risk” was initially catheterized with a microcatheter. Stent placement was successful in 19 aneurysms. In a reopened basilar tip aneurysm, Y-like stent placement through a Neuroform stent failed. With secondary stent placement (n = 8), all affected vessels could be safely reopened. None of these patients suffered from transient or permanent neurologic deficits. Using the jailing technique, it was possible to place two parallel stents in the internal carotid artery and posterior cerebral artery (PCA) in a reopened wide-necked PCA aneurysm. Apart from the primary use of the Enterprise stent in wide-necked aneurysm secondary stenting after coiling is a feasible technique to reopen occluded parent or branching arteries. Initial microcatheter placement in the artery which is at risk to get occluded when filling the aneurysm is a valuable option. Selbstexpandierende Mikrostents werden typischerweise platziert, bevor weithalsige Aneurysmen mit Platinspiralen gefüllt werden. Alternativ kann der Stent am Ende der Untersuchung platziert werden, wenn der Fluss im Trägergefäß oder in einem größeren abgehenden Gefäß blockiert wird oder abnimmt. Zwischen März 2007 und 2009 wurden 20 Aneurysmen bei 20 Patienten mit insgesamt 21 Enterprise- Stents versorgt. Neun Aneurysmen waren wiedereröffnet, elf Aneurysmen wurden primär behandelt, sieben davon nach frischer Subarachnoidalblutung. Acht Aneurysmen wurden primär mit Platinspiralen gefüllt, und der Stent wurde platziert, nachdem der Fluss im Trägergefäß oder in einem größeren Ast blockiert wurde oder abnahm. Bei vier dieser Patienten wurde die verschlussgefährdete Arterie primär mit einem Mikrokatheter markiert. Der Stent wurde bei 19 Patienten an der gewünschten Position freigesetzt. Bei einem Patienten misslang eine Y-förmige Stentimplantation über einen Neuroform-Stent mit Jailing des Basilariskopf-Aneurysmarests. Nach sekundärer Stentimplantation wurden alle Gefäße wiedereröffnet, kein Patient erlitt ein transientes oder permanentes neurologisches Defizit. Mit Hilfe der Jailing-Technik war es in einem Fall eines weithalsigen Aneurysmarezidivs der A. communicans posterior möglich, Stents parallel von der A. carotis interna in die A. cerebri media und die A. cerebri posterior zu platzieren. Neben der primären Stentimplantation vor Coiling ist die sekundäre Stentimplantation nach Coiling eine alternative Technik, um verschlossene Gefäße wiederzueröffnen. Zudem können verschlussgefährdete Arterien primär mit einem Mikrokatheter markiert werden.
- 23 August 2009
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 19 (3) , 197-203
The Enterprise Stent for the Treatment of Intracranial Aneurysms
Self-expanding microstents are typically placed before a wide-necked aneurysm is filled with coils. Alternatively, the stent may be placed at the end of the procedure, when the coil mass blocks or slows down the flow in the parent artery or a branching vessel. Between March 2007 and 2009, 20 aneurysms in 20 patients were treated with a total of 21 Enterprise stents. Nine aneurysms had reopened after coiling, eleven aneurysms were primarily treated, seven after acute subarachnoid hemorrhage. Eight aneurysms were primarily filled with coils and the stent was placed when the flow in the parent or a branching artery was blocked or slowed down. In four of these cases in which secondary stenting was considered an option in advance, the “artery at risk” was initially catheterized with a microcatheter. Stent placement was successful in 19 aneurysms. In a reopened basilar tip aneurysm, Y-like stent placement through a Neuroform stent failed. With secondary stent placement (n = 8), all affected vessels could be safely reopened. None of these patients suffered from transient or permanent neurologic deficits. Using the jailing technique, it was possible to place two parallel stents in the internal carotid artery and posterior cerebral artery (PCA) in a reopened wide-necked PCA aneurysm. Apart from the primary use of the Enterprise stent in wide-necked aneurysm secondary stenting after coiling is a feasible technique to reopen occluded parent or branching arteries. Initial microcatheter placement in the artery which is at risk to get occluded when filling the aneurysm is a valuable option. Selbstexpandierende Mikrostents werden typischerweise platziert, bevor weithalsige Aneurysmen mit Platinspiralen gefüllt werden. Alternativ kann der Stent am Ende der Untersuchung platziert werden, wenn der Fluss im Trägergefäß oder in einem größeren abgehenden Gefäß blockiert wird oder abnimmt. Zwischen März 2007 und 2009 wurden 20 Aneurysmen bei 20 Patienten mit insgesamt 21 Enterprise- Stents versorgt. Neun Aneurysmen waren wiedereröffnet, elf Aneurysmen wurden primär behandelt, sieben davon nach frischer Subarachnoidalblutung. Acht Aneurysmen wurden primär mit Platinspiralen gefüllt, und der Stent wurde platziert, nachdem der Fluss im Trägergefäß oder in einem größeren Ast blockiert wurde oder abnahm. Bei vier dieser Patienten wurde die verschlussgefährdete Arterie primär mit einem Mikrokatheter markiert. Der Stent wurde bei 19 Patienten an der gewünschten Position freigesetzt. Bei einem Patienten misslang eine Y-förmige Stentimplantation über einen Neuroform-Stent mit Jailing des Basilariskopf-Aneurysmarests. Nach sekundärer Stentimplantation wurden alle Gefäße wiedereröffnet, kein Patient erlitt ein transientes oder permanentes neurologisches Defizit. Mit Hilfe der Jailing-Technik war es in einem Fall eines weithalsigen Aneurysmarezidivs der A. communicans posterior möglich, Stents parallel von der A. carotis interna in die A. cerebri media und die A. cerebri posterior zu platzieren. Neben der primären Stentimplantation vor Coiling ist die sekundäre Stentimplantation nach Coiling eine alternative Technik, um verschlossene Gefäße wiederzueröffnen. Zudem können verschlussgefährdete Arterien primär mit einem Mikrokatheter markiert werden.
- 26 February 2009
- Published by Springer Nature in Neuroradiology
- Vol. 51 (7) , 433-443
Simple and complex dysembryoplastic neuroepithelial tumors (DNT) variants: clinical profile, MRI, and histopathology
Dysembryoplastic neuroepithelial tumors (DNTs) are long-term epilepsy associated tumors subdivided into simple and complex variants. The purpose of this study was to relate different DNT components identified on magnetic resonance imaging (MRI) to histopathological features and to test the hypothesis that glial nodules as a histopathological feature of complex variants induce an occasional glioma misdiagnosis. Clinical, MRI, and histopathologic features of DNTs operated between 1988 and 2008 were reviewed. From a total of 61 DNTs, 48 simple and 13 complex variants were identified. Multiple or single pseudocysts in a cortical/subcortical location with small cysts sometimes separated from the tumor represented the glioneuronal element and were found in all DNTs. FLAIR hyperintense tissue was found between pseudocysts but—in neocortical DNTs—also circumscript in deeper tumor parts. Calcification and hemorrhages in this location occurred in four of 13 complex variants, and one of these patients was also the only one with tumor growth. Patients with complex variants had earlier seizure onset, and complex variants were more often located outside the temporal lobe. Although complex variants represented a higher diagnostic challenge, misdiagnoses also occurred in simple variants. One of five of DNTs showed contrast enhancement, which varied on follow-up studies with enhancing parts becoming nonenhancing and vice versa. The glioneuronal element is readily identifiable on MRI and should be considered to support the DNT diagnosis. Complex DNT variants have a different clinical profile and a more variable histopathological and MRI appearance; however, misdiagnoses occasionally also occur in simple variants.
- 26 February 2009
- Published by Springer Nature in Neuroradiology
- Vol. 51 (7) , 433-443
Simple and complex dysembryoplastic neuroepithelial tumors (DNT) variants: clinical profile, MRI, and histopathology
Dysembryoplastic neuroepithelial tumors (DNTs) are long-term epilepsy associated tumors subdivided into simple and complex variants. The purpose of this study was to relate different DNT components identified on magnetic resonance imaging (MRI) to histopathological features and to test the hypothesis that glial nodules as a histopathological feature of complex variants induce an occasional glioma misdiagnosis. Clinical, MRI, and histopathologic features of DNTs operated between 1988 and 2008 were reviewed. From a total of 61 DNTs, 48 simple and 13 complex variants were identified. Multiple or single pseudocysts in a cortical/subcortical location with small cysts sometimes separated from the tumor represented the glioneuronal element and were found in all DNTs. FLAIR hyperintense tissue was found between pseudocysts but—in neocortical DNTs—also circumscript in deeper tumor parts. Calcification and hemorrhages in this location occurred in four of 13 complex variants, and one of these patients was also the only one with tumor growth. Patients with complex variants had earlier seizure onset, and complex variants were more often located outside the temporal lobe. Although complex variants represented a higher diagnostic challenge, misdiagnoses also occurred in simple variants. One of five of DNTs showed contrast enhancement, which varied on follow-up studies with enhancing parts becoming nonenhancing and vice versa. The glioneuronal element is readily identifiable on MRI and should be considered to support the DNT diagnosis. Complex DNT variants have a different clinical profile and a more variable histopathological and MRI appearance; however, misdiagnoses occasionally also occur in simple variants.
- 31 July 2008
- Published by Elsevier in Epilepsy Research
- Vol. 80 (1) , 67-76
Strongly lateralized activation in language fMRI of atypical dominant patients—Implications for presurgical work-up
- 31 July 2008
- Published by Elsevier in Epilepsy Research
- Vol. 80 (1) , 67-76
Strongly lateralized activation in language fMRI of atypical dominant patients—Implications for presurgical work-up
- 1 February 2008
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 29 (1) , 40-46
MRI of Long-Term Epilepsy-Associated Tumors
- 1 February 2008
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 29 (1) , 40-46
MRI of Long-Term Epilepsy-Associated Tumors
- 10 January 2008
- Published by Springer Nature in Neuroradiology
- Vol. 50 (5) , 383-389
Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study
Since digital subtraction angiography (DSA) carries a low risk of morbidity, and is associated with patient discomfort and higher cost, our objective was to determine whether high-resolution 3-D time-of-flight MR angiography (TOF-MRA) at 3 T may replace DSA in the follow-up of patients after coiling of an intracranial aneurysm.
- 10 January 2008
- Published by Springer Nature in Neuroradiology
- Vol. 50 (5) , 383-389
Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study
Since digital subtraction angiography (DSA) carries a low risk of morbidity, and is associated with patient discomfort and higher cost, our objective was to determine whether high-resolution 3-D time-of-flight MR angiography (TOF-MRA) at 3 T may replace DSA in the follow-up of patients after coiling of an intracranial aneurysm.
- 1 October 2007
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 16 (7) , 608-614
Correlation of MRI and histopathology in epileptogenic parietal and occipital lobe lesions
- 1 October 2007
- Published by Elsevier in Seizure: European Journal of Epilepsy
- Vol. 16 (7) , 608-614
Correlation of MRI and histopathology in epileptogenic parietal and occipital lobe lesions