  • Entrapment of a Pacing Lead within a Chiari Network - Utility of Intracardiac Echo and a Laser Sheath

    by Htin Aung, Raul E. Espinosa, Brian D. Powell, Christopher J. McLeod

    Although rare, Chiari networks are elaborate embryological remnants that can pose distinct challenges for catheter and pacing lead manipulation within the right atrium (Figure 1). Device entrapment may require open thoracotomy for removal, with significant morbidity. We report an unusual case of pacing lead entanglement within this structure, followed by prompt intracardiac echocardiographic identification and laser sheath removal.This article is protected by copyright. All rights reserved


  • Noise, Artifact, and Oversensing Related Inappropriate ICD Shock Evaluation: ALTITUDE NOISE Study

    by Brian D. Powell, Samuel J. Asirvatham, David L. Perschbacher, Paul W. Jones, Yong‐Mei Cha, David A. Cesario, Michael Cao, Iii F. Roosevelt Gilliam, Leslie A. Saxon

    Background: Approximately 12–21% of implantable cardioverter defibrillator (ICD) patients receive inappropriate shocks. We sought to determine the incidence and causes of noise/artifact and oversensing (NAO) resulting in ICD shocks. Methods: A random sample of 2,000 patients who received ICD and cardiac resynchronization therapy defibrillator shocks and were followed by a remote monitoring system was included. Seven electrophysiologists analyzed stored electrograms from the 5,279 shock episodes. Episodes were adjudicated as appropriate or inappropriate shocks. Results: Of the 5,248 shock episodes with complete adjudication, 1,570 (30%) were judged to be inappropriate shocks. Of these 1,570, 134 (8.5%) were a result of NAO. The 134 NAO episodes were determined to be due to external noise in 76 (57%), lead connector‐related in 37 (28%), muscle noise in 11 (8%), oversensing of atrium in seven (5%), T‐wave oversensing in two (2%), and other noise in one (1%). The ICD shock itself resulted in a marked decrease in the level of noise in 60 of 134 (45%) NAO episodes, and the magnitude of this effect varied with the type of NAO (58% for external noise, 35% for muscle, 27% for lead/connector, and 0% for oversensing; P = 0.03). There was no significant difference in NAO likelihood based on type of lead (integrated bipolar 89/1,802 vs dedicated bipolar 9/140, P = 0.67). Conclusions: External noise and lead/connector noise were the primary causes, while T‐wave oversensing was the least common cause of NAO resulting in ICD shock. Noise/artifact decreased immediately after a shock in nearly half of episodes. The specific ICD lead type did not impact the likelihood of NAO. (PACE 2012;XX:1–7)


    • 1 May 2011
      • Vol. 11  (3) , 64-72
    Open Access

    Anodal Stimulation: An Underrecognized Cause of Nonresponders to Cardiac Resynchronization Therapy

    by Khalin F Dendy, Brian D Powell, Yong-Mei Cha, Raul E Espinosa, Paul A Friedman, Robert F Rea, David L Hayes, Margaret M Redfield, Samuel J Asirvatham

    The purpose of this study was to determine if anodal stimulation accounts for failure to benefit from cardiac resynchronization therapy (CRT) in some patients. Approximately 30-40% of patients with moderate to severe heart failure do not have symptomatic nor echocardiographic improvement in cardiac function following CRT. Modern CRT devices allow the option of programming left ventricular (LV) lead pacing as LV tip to right ventricular (RV) lead coil to potentially improve pacing thresholds. However, anodal stimulation can result in unintentional RV pacing (anode) instead of LV pacing (cathode). Patients enrolled in our center's CRT registry had an echocardiogram, 6-minute walk (6MW), and Minnesota Living with HF Questionnaire (MLHFQ) pre-implant and 6 months after CRT. Electrocardiograms (12 lead) during RV, LV, and biventricular (BiV) pacing were obtained at the end of the implant in 102 patients. Anodal stimulation was defined as LV pacing QRS morphology on EKG being identical to RV pacing or consistent with fusion with RV and LV electrode capture. LV end systolic volume (LVESV) was measured by echo biplane Simpson's method and CRT responder was defined as 15% or greater reduction in LVESV. Of the 102 patients, 46 (45.1%) had the final LV lead pacing configuration programmed LV (tip or ring) to RV (coil or ring). 3 of the 46 subjects (6.5%) had EKG findings consistent with anodal stimulation, not corrected intraoperatively. All anodal stimulation patients were nonresponders to CRT by echo criteria (reduction in LVESV 13.3 ± 0.6%, increase in EF 5.0 ± 1.4%) compared to 46% responders for those without anodal stimulation, (change in LVESV 18.7 ± 25.6%, EF 7.6 ±10.9%). None of the anodal stimulation patients were responders for the 6 minute walk, compared to 32 of 66 (48%) of those without anodal stimulation. Anodal stimulation is a potential underrecognized and ameliorable cause of poor response to CRT.


  • Open Access

    Does image integration improve atrial fibrillation ablation outcomes, or are other aspects of the ablation the key to success?

    by Brian D. Powell, Douglas L. Packer

    Over the years, various imaging modalities have been used to guide ablation procedures. Technology has rapidly progressed from Two-dimensional fluoroscopic imaging to several different forms of 3D mapping systems using magnetic and impedance sensors, as well as automated imaging components derived from computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and rotational angiography. These have provided greater anatomic detail for accurate ablation. However, ablation outcomes rely not only on image guided proper lesion location, but also adequate catheter contact, power, duration of energy delivery, and overall ablation strategy.


  • Influence of Preoperative Lipid-Lowering Therapy on Postoperative Outcome in Patients Undergoing Coronary Artery Bypass Grafting

    by Brian D. Powell, Kevin A. Bybee, Uma Valeti, Randal J. Thomas, Stephen L. Kopecky, Charles J. Mullany, R. Scott Wright