Hong Wei Ouyang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hong Wei Ouyang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Kyaw Moe
Department of Mechanical Engineering, National University of Singapore, Singapore
2 shared publications- Tong Cao
Faculty of Dentistry, National University of Singapore, Singapore, Singapore
2 shared publications - Tong Earn Tay
Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117565, Singapore
2 shared publications - Boon Chin Heng
Department of Dental Materials & Dental Medical Devices Testing Center Peking University School and Hospital of Stomatology Beijing P. R. China
1 shared publication - Guang-Yan Yu
Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China
1 shared publication He Liu
1 shared publication
Latest Publications
- 18 February 2013
- Vol. 45 (1) , 9-11
[Development of human embryonic stem cell model for toxicity evaluation].
The current international standard for toxicity screening of biomedical devices and materials recommend the use of immortalized cell lines because of their homogeneous morphologies and infinite proliferation which provide good reproducibility for in vitro cytotoxicity screening. However, most of the widely used immortalized cell lines are derived from animals and may not be representative of normal human cell behavior in vivo, in particular in terms of the cytotoxic and genotoxic response. Therefore, It is vital to develop a model for toxicity evaluation. In our studies, two Chinese human embryonic stem cell (hESC) lines as toxicity model were established. hESC derived tissue/organ cell model for tissue/organ specific toxicity evaluation were developed. The efficiency and accuracy of using hESC model for cytoxicity, embryotoxicity and genotoxicity evaluation were confirmed. The results indicated that hESCs might be good tools for toxicity testing and biosafety evaluation in vitro.
- 18 February 2013
- Vol. 45 (1) , 9-11
[Development of human embryonic stem cell model for toxicity evaluation].
The current international standard for toxicity screening of biomedical devices and materials recommend the use of immortalized cell lines because of their homogeneous morphologies and infinite proliferation which provide good reproducibility for in vitro cytotoxicity screening. However, most of the widely used immortalized cell lines are derived from animals and may not be representative of normal human cell behavior in vivo, in particular in terms of the cytotoxic and genotoxic response. Therefore, It is vital to develop a model for toxicity evaluation. In our studies, two Chinese human embryonic stem cell (hESC) lines as toxicity model were established. hESC derived tissue/organ cell model for tissue/organ specific toxicity evaluation were developed. The efficiency and accuracy of using hESC model for cytoxicity, embryotoxicity and genotoxicity evaluation were confirmed. The results indicated that hESCs might be good tools for toxicity testing and biosafety evaluation in vitro.
- 27 July 2006
- Published by Wolters Kluwer Health in Transplantation
- Vol. 82 (2) , 170-174
Mesenchymal Stem Cell Sheets Revitalize Nonviable Dense Grafts: Implications for Repair of Large-Bone and Tendon Defects
Large musculoskeletal defects are commonly reconstructed with allogeneic grafts. As cryopreserved allogeneic grafts lack viable cells, this often results in poorer clinical outcome. Current technology can not incorporate large number of cells to the dense grafts. This study aimed to investigate the feasibility of fabricating sheets of mesenchymal stem cells (MSCs) to revitalize cryopreserved grafts. Human MSCs were isolated, characterized, and cultured to form a cell sheet in the presence of ascorbic acid. Once a sheet of MSCs was obtained, it was assembled onto the demineralized bone grafts or frozen tendon grafts by a wrapping technique. Then the assembled structure was cultured for 3 weeks. The macro morphology, histology, and immunohistochemistry of the grafts were evaluated. It was found that MSCs were able to form coherent cellular sheets within 3 weeks. When assembled with demineralized bone matrix, MSC sheets were similar to in situ periosteum and were able to differentiate into the osteochondral lineage. When assembled with frozen tendon graft, MSCs sheets were well-incorporated within the tissue sheath (peritenon) around the tendon, and adopted the characteristic spindle-shaped morphology of tenocyte-like cells. The results therefore demonstrated that MSCs sheets are easily fabricated and can maintain their differentiation potential within particular scaffolds, which would suggest a novel and convenient strategy for revitalizing large tissue grafts to improve clinical outcome.
- 27 July 2006
- Published by Wolters Kluwer Health in Transplantation
- Vol. 82 (2) , 170-174
Mesenchymal Stem Cell Sheets Revitalize Nonviable Dense Grafts: Implications for Repair of Large-Bone and Tendon Defects
Large musculoskeletal defects are commonly reconstructed with allogeneic grafts. As cryopreserved allogeneic grafts lack viable cells, this often results in poorer clinical outcome. Current technology can not incorporate large number of cells to the dense grafts. This study aimed to investigate the feasibility of fabricating sheets of mesenchymal stem cells (MSCs) to revitalize cryopreserved grafts. Human MSCs were isolated, characterized, and cultured to form a cell sheet in the presence of ascorbic acid. Once a sheet of MSCs was obtained, it was assembled onto the demineralized bone grafts or frozen tendon grafts by a wrapping technique. Then the assembled structure was cultured for 3 weeks. The macro morphology, histology, and immunohistochemistry of the grafts were evaluated. It was found that MSCs were able to form coherent cellular sheets within 3 weeks. When assembled with demineralized bone matrix, MSC sheets were similar to in situ periosteum and were able to differentiate into the osteochondral lineage. When assembled with frozen tendon graft, MSCs sheets were well-incorporated within the tissue sheath (peritenon) around the tendon, and adopted the characteristic spindle-shaped morphology of tenocyte-like cells. The results therefore demonstrated that MSCs sheets are easily fabricated and can maintain their differentiation potential within particular scaffolds, which would suggest a novel and convenient strategy for revitalizing large tissue grafts to improve clinical outcome.
- 13 September 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 75B (2) , 264-271
Assembly of bone marrow stromal cell sheets with knitted poly (L‐lactide) scaffold for engineering ligament analogs
The current cell seeding technique has several disadvantages, such as low efficiency of cell attachment to scaffolds and the limited strength of cell–gel composite adhesion to scaffold. These problems warrant further study to improve the assembly of cell to scaffold. Therefore this study aims to fabricate a bone marrow stromal cells (bMSCs) sheet and assemble it on a knitted poly (L‐lactide) (PLLA) scaffold for engineering ligament analogs. bMSCs were cultured to form a cell sheet in the presence of ascorbic acid. Once a sheet of bMSCs was obtained, it was assembled onto the knitted scaffold by a wrapping technique. Then the assembled structure was held in place in a spinner flask for 4 weeks. The macromorphology, histology, and biomechanics of the grafts were evaluated. The composite of cell sheet/PLLA scaffold constructs had transformed into tissuelike ligament analogs. Immunohistochemical analysis showed that the components of the analogs were similar to that of ligament tissues, consisting primarily of collagen type I and small amount of collagen type III and tenascin. The failure force of the cell/scaffold assembly under tension (46.68 ± 2.29 N) was higher than that of the scaffold group (43.58 ± 2.41 N; p < 0.05), but tensile stiffness of the cell/scaffold group (20.6 ± 1.417 N/mm) was significantly lower than that of the scaffold group (27.6 ± 1.449 N/mm; p < 0.05). These data showed that the incorporation of bMSCs sheet onto the PLLA scaffold could make the analog stronger and more stretchable. Therefore the approach of assembling bMSCs sheet onto knitted PLLA scaffold is promising for producing tissuelike and functional ligament analogs under dynamic fluid situation for the purpose of anterior cruciate ligament (ACL) reconstruction. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
- 13 September 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 75B (2) , 264-271
Assembly of bone marrow stromal cell sheets with knitted poly (L‐lactide) scaffold for engineering ligament analogs
The current cell seeding technique has several disadvantages, such as low efficiency of cell attachment to scaffolds and the limited strength of cell–gel composite adhesion to scaffold. These problems warrant further study to improve the assembly of cell to scaffold. Therefore this study aims to fabricate a bone marrow stromal cells (bMSCs) sheet and assemble it on a knitted poly (L‐lactide) (PLLA) scaffold for engineering ligament analogs. bMSCs were cultured to form a cell sheet in the presence of ascorbic acid. Once a sheet of bMSCs was obtained, it was assembled onto the knitted scaffold by a wrapping technique. Then the assembled structure was held in place in a spinner flask for 4 weeks. The macromorphology, histology, and biomechanics of the grafts were evaluated. The composite of cell sheet/PLLA scaffold constructs had transformed into tissuelike ligament analogs. Immunohistochemical analysis showed that the components of the analogs were similar to that of ligament tissues, consisting primarily of collagen type I and small amount of collagen type III and tenascin. The failure force of the cell/scaffold assembly under tension (46.68 ± 2.29 N) was higher than that of the scaffold group (43.58 ± 2.41 N; p < 0.05), but tensile stiffness of the cell/scaffold group (20.6 ± 1.417 N/mm) was significantly lower than that of the scaffold group (27.6 ± 1.449 N/mm; p < 0.05). These data showed that the incorporation of bMSCs sheet onto the PLLA scaffold could make the analog stronger and more stretchable. Therefore the approach of assembling bMSCs sheet onto knitted PLLA scaffold is promising for producing tissuelike and functional ligament analogs under dynamic fluid situation for the purpose of anterior cruciate ligament (ACL) reconstruction. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
- 12 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5852, 665-671
Cyclic uniaxial strains on fibroblasts-seeded PLGA scaffolds for tissure engineering of ligaments
Mechanical strain regulates the structure and mechanical properties of the engineering tissue. Previous studies showed that cyclic mechanical strain affect in development and function of cells in tissue formation on various three-dimension scaffolds. In this study, the effect of cyclic uniaxial tensile straining on cell morphology was investigated. The objective of this research is to investigate the effect of cyclic uniaxial strain on cells' growth on knitted PLGA (Poly-Lactide-co-glycolide) scaffolds. A biocompatible cyclic uniaxial tensile straining device (bioreactor) was developed. Cyclic uniaxial straining was applied at 1.8% strain for 4 hours daily. To study the effect of cyclic frequency on cells' growth, two sets (1Hz and 0.1 Hz) of frequencies were used. After two weeks stimulation, the cell morphology was studied with the aid of Hematoxylin & Eosin staining using paraffin sectioning. In both frequency sets the mean nuclei length are longer than unstrained specimens. The cell population also tended to orientate parallel to the straining axis. In 0.1Hz frequency straining, more cell population are aligned in the straining direction than in 1Hz frequency. This study has demonstrated that cyclic uniaxial strain affect on cell morphology and mechanical properties of engineering tissue.
- 12 April 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5852, 665-671
Cyclic uniaxial strains on fibroblasts-seeded PLGA scaffolds for tissure engineering of ligaments
Mechanical strain regulates the structure and mechanical properties of the engineering tissue. Previous studies showed that cyclic mechanical strain affect in development and function of cells in tissue formation on various three-dimension scaffolds. In this study, the effect of cyclic uniaxial tensile straining on cell morphology was investigated. The objective of this research is to investigate the effect of cyclic uniaxial strain on cells' growth on knitted PLGA (Poly-Lactide-co-glycolide) scaffolds. A biocompatible cyclic uniaxial tensile straining device (bioreactor) was developed. Cyclic uniaxial straining was applied at 1.8% strain for 4 hours daily. To study the effect of cyclic frequency on cells' growth, two sets (1Hz and 0.1 Hz) of frequencies were used. After two weeks stimulation, the cell morphology was studied with the aid of Hematoxylin & Eosin staining using paraffin sectioning. In both frequency sets the mean nuclei length are longer than unstrained specimens. The cell population also tended to orientate parallel to the straining axis. In 0.1Hz frequency straining, more cell population are aligned in the straining direction than in 1Hz frequency. This study has demonstrated that cyclic uniaxial strain affect on cell morphology and mechanical properties of engineering tissue.