FDFrancis A. DiGiano

Francis A. DiGiano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francis A. DiGiano has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of E. coli and Virus Reductions Using Replicate, Bench-Scale Biosand Filter Columns and Two Filter Media

    by Mark Elliott, Christine E. Stauber, Francis A. DiGiano, Anna Fabiszewski De Aceituno, Mark D. Sobsey

    The biosand filter (BSF) is an intermittently operated, household-scale slow sand filter for which little data are available on the effect of sand composition on treatment performance. Therefore, bench-scale columns were prepared according to the then-current (2006–2007) guidance on BSF design and run in parallel to conduct two microbial challenge experiments of eight-week duration. Triplicate columns were loaded with Accusand silica or crushed granite to compare virus and E. coli reduction performance. Bench-scale experiments provided confirmation that increased schmutzdecke growth, as indicated by decline in filtration rate, is the primary factor causing increased E. coli reductions of up to 5-log10. However, reductions of challenge viruses improved only modestly with increased schmutzdecke growth. Filter media type (Accusand silica vs. crushed granite) did not influence reduction of E. coli bacteria. The granite media without backwashing yielded superior virus reductions when compared to Accusand. However, for columns in which the granite media was first backwashed (to yield a more consistent distribution of grains and remove the finest size fraction), virus reductions were not significantly greater than in columns with Accusand media. It was postulated that a decline in surface area with backwashing decreased the sites and surface area available for virus sorption and/or biofilm growth and thus decreased the extent of virus reduction. Additionally, backwashing caused preferential flow paths and deviation from plug flow; backwashing is not part of standard BSF field preparation and is not recommended for BSF column studies. Overall, virus reductions were modest and did not meet the 5- or 3-log10 World Health Organization performance targets.


  • Residence Time from Tracer Tests: Field Experience and Calculation Techniques

    by Francis A. DiGiano, Andrew Westbrook, Weidong Zhang

    The planning and execution of chemical tracer tests have been detailed in a recent reference guide developed by the U.S. EPA for water utilities. The objective of this paper is to extend the EPA guidance by presenting a simple, analytical technique to calculate mean residence time (MRT) from chemical tracer data. Case histories of tracer tests in three distribution systems in North Carolina (Raleigh, Greenville, and Cary) are used to illustrate the technique. Examples are given of the time required for sampling and the mileage driven. Tracer responses to positive and negative step input tracer tests are compared. Storage tanks are shown to affect the tracer response at nearby stations and complicate calculation of an MRT value. The MRT values obtained at 22 stations in the Raleigh distribution system compared fairly well to hydraulic model predictions of the average water age. This paper was presented at the 8th Annual Water Distribution Systems Analysis Symposium which was held with the generous support of Awwa Research Foundation (AwwaRF).

  • Calculation of the mean residence time in distribution systems from tracer studies and models

    by Francis A. DiGiano, Weidong Zhang, Alessandro Travaglia

    The residence time of water within the distribution system (DS) is a key parameter to characterize the extent of disinfectant loss and disinfectant by-product formation. While hydraulic models include calculation of a parameter referred to commonly as ‘water age’, the expense of development and calibration has restricted their availability. Chemical tracer studies provide a less expensive alternative way to estimate water age even if these may need to be repeated to capture the seasonal range of water demand. This research presents a technique to calculate the ‘mean residence time’ (MRT) from tracer studies by applying well-known principles from chemical reactor engineering. A numerical experiment was first performed using a pipe network from a case study. A negative step input of a conservative chemical to a case study DS was simulated using the EPANET model. The response curves at a series of nodes were predicted by the water quality sub model of EPANET from which the MRTmodel values were calculated. MRTmodel values were close to the average water age as predicted by the hydraulic sub model of EPANET. Actual tracer studies were conducted in the distribution systems of Raleigh (serving 250,000) and Durham (serving 190,000), North Carolina. MRTfield values were calculated from tracer response data at a series of sampling stations. A highly skeletonized hydraulic model was available for the Raleigh DS to generate a predicted average water age. The MRTfield values at 12 stations were consistently higher than average water age, most likely because the hydraulic model was too highly skeletonized. The tracer study in the Durham DS showed the use of two or more tracers to calculate an MRTfield that was weighted by the percentage contribution of water from each of two water treatment plants.


  • Uncertainty Analysis in a Mechanistic Model of Bacterial Regrowth in Distribution Systems

    by Francis A. DiGiano, Weidong Zhang

    The first generation of mechanistic models of bacterial regrowth in distribution systems (DS) provides insight into cause-and-effect relationships. However, the state of knowledge about the processes included in these models is insufficient to warrant deterministic predictions. Even if the process descriptions are reasonable, the uncertainty in values of key system constants limits predictions of bacterial growth. A new mechanistic model was developed to incorporate the accepted knowledge of physical, chemical, and biological processes with the hydraulic features in order to capture the unsteady state behavior of the DS. Sensitivity testing showed that the extent of bacterial regrowth was affected mainly by the rate constants for chlorine decay reactions in bulk water and on the pipe wall and by the maximum growth rate constant of attached bacteria. A simple hypothetical network was used to evaluate the effects of uncertainty in these three system constants by running 100 Monte Carlo simulations. Cumulative probability plots showed a wide range of predictions for concentrations of bacteria and chlorine in bulk water at various nodes in the DS. The magnitude of these concentrations and the range of values were greatly affected by water residence time to each node. Once the chlorine residual is depleted, bacterial growth is mainly influenced by the amount of substrate available. However, high values of the coefficients for the maximum growth rate of attached bacteria, the chlorine decay in bulk water, and the chlorine decay by wall reaction did not necessarily lead to the maximum bacterial growth at a given location.