Andrew J. de Mello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrew J. de Mello has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Joshua B. Edel
Department of Chemistry, Imperial College London, London, UK
4 shared publications Nigel P. Beard
Department of Chemistry, Imperial College London, Exhibition Road, South Kensington, London, UK
3 shared publicationsMichael C. Mitchell
Zeneca/SmithKline Beecham Centre for Analytical Science, Imperial College of Science, Technology and Medicine, Department of Chemistry, South Kensington, London, UK
2 shared publicationsRobin Fortt
Department of Chemistry, Imperial College of Science, Technology and Medicine, Exhibition Road, South Kensington, London, UK
2 shared publicationsValerie Spikmans
Zeneca/SmithKline Beecham Centre for Analytical Science, Imperial College of Science, Technology and Medicine, Department of Chemistry, South Kensington, London, UK
2 shared publications- Andreas Manz
KIST Europe, 66123 Saarbrücken, Germany
1 shared publication
Latest Publications
- 14 July 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (14) , 2363-2373
Integrated on‐chip derivatization and electrophoresis for the rapid analysis of biogenic amines
We demonstrate the monolithic integration of a chemical reactor with a capillary electrophoresis device for the rapid and sensitive analysis of biogenic amines. Fluorescein isothiocyanate (FITC) is widely employed for the analysis of amino‐group containing analytes. However, the slow reaction kinetics hinders the use of this dye for on‐chip labeling applications. Other alternatives are available such as o‐phthaldehyde (OPA), however, the inferior photophysical properties and the UV λmax present difficulties when using common excitation sources leading to a disparity in sensitivity. Consequently, we present for the first time the use of dichlorotriazine fluorescein (DTAF) as a superior in situ derivatizing agent for biogenic amines in microfluidic devices. The developed microdevice employs both hydrodynamic and electroosmotic flow, facilitating the creation of a polymeric microchip to perform both precolumn derivatization and electrophoretic analysis. The favorable photophysical properties of the DTAF and its fast reaction kinetics provide detection limits down to 1 nM and total analysis times (including on‐chip mixing and reaction) of <60 s. The detection limits are two orders of magnitude lower than current limits obtained with both FITC and OPA. The optimized microdevice is also employed to probe biogenic amines in real samples.
- 14 July 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (14) , 2363-2373
Integrated on‐chip derivatization and electrophoresis for the rapid analysis of biogenic amines
We demonstrate the monolithic integration of a chemical reactor with a capillary electrophoresis device for the rapid and sensitive analysis of biogenic amines. Fluorescein isothiocyanate (FITC) is widely employed for the analysis of amino‐group containing analytes. However, the slow reaction kinetics hinders the use of this dye for on‐chip labeling applications. Other alternatives are available such as o‐phthaldehyde (OPA), however, the inferior photophysical properties and the UV λmax present difficulties when using common excitation sources leading to a disparity in sensitivity. Consequently, we present for the first time the use of dichlorotriazine fluorescein (DTAF) as a superior in situ derivatizing agent for biogenic amines in microfluidic devices. The developed microdevice employs both hydrodynamic and electroosmotic flow, facilitating the creation of a polymeric microchip to perform both precolumn derivatization and electrophoretic analysis. The favorable photophysical properties of the DTAF and its fast reaction kinetics provide detection limits down to 1 nM and total analysis times (including on‐chip mixing and reaction) of <60 s. The detection limits are two orders of magnitude lower than current limits obtained with both FITC and OPA. The optimized microdevice is also employed to probe biogenic amines in real samples.
- Open Access
- 14 July 2003
- Published by Springer Nature in Analytical Sciences
- Vol. 19 (7) , 1065-1069
Single Particle Confocal Fluorescence Spectroscopy in Microchannels: Dependence of Burst Width and Burst Area Distributions on Particle Size and Flow Rate
This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (200-930 nm diameter) passing through a focused laser beam at a variety of flow rates (100-1000 nL/min). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate single-particle burst width and burst area distributions. Analysis of such distributions demonstrates that the average burst width and burst area decrease as particle size increases. In addition, both burst width and burst area (for a given particle size) are observed to decrease as volumetric flow rate is increased. The dependence of such distributions on particle size is proposed as a potential route to sizing single particles and molecules in microfluidic systems.
- 14 July 2003
- Published by Springer Nature in Analytical Sciences
- Vol. 19 (7) , 1065-1069
Open AccessSingle Particle Confocal Fluorescence Spectroscopy in Microchannels: Dependence of Burst Width and Burst Area Distributions on Particle Size and Flow Rate
This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (200-930 nm diameter) passing through a focused laser beam at a variety of flow rates (100-1000 nL/min). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate single-particle burst width and burst area distributions. Analysis of such distributions demonstrates that the average burst width and burst area decrease as particle size increases. In addition, both burst width and burst area (for a given particle size) are observed to decrease as volumetric flow rate is increased. The dependence of such distributions on particle size is proposed as a potential route to sizing single particles and molecules in microfluidic systems.
- 24 February 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (4) , 732-739
In‐column field‐amplified sample stacking of biogenic amines on microfabricated electrophoresis devices
A novel method for performing in‐column field‐amplified sample stacking (FASS) in chip‐based electrophoretic systems is presented. The methodology involves the use of a narrow sample channel (NSC) injector. NSC injectors allow sample plugs to be introduced directly into the separation channel, and subsequent stacking and separation can proceed without any need for leakage control. More importantly, stacking and separation occur in a single step negating the requirement for complex channel geometries and voltage switching to control sample plugs during the stacking procedure. The chip is composed of six paralleled systems. Using the NSC injector design, the number of reservoirs in the multiplexed chip is reduced to N + 2, where N is the number of paralleled systems. This design feature radically reduces the complexity in chip structures and associated chip operation. The approach is applied to the analysis of fluorescently labelled biogenic amines affording detection at concentrations down to 20 pM.
- 24 February 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (4) , 732-739
In‐column field‐amplified sample stacking of biogenic amines on microfabricated electrophoresis devices
A novel method for performing in‐column field‐amplified sample stacking (FASS) in chip‐based electrophoretic systems is presented. The methodology involves the use of a narrow sample channel (NSC) injector. NSC injectors allow sample plugs to be introduced directly into the separation channel, and subsequent stacking and separation can proceed without any need for leakage control. More importantly, stacking and separation occur in a single step negating the requirement for complex channel geometries and voltage switching to control sample plugs during the stacking procedure. The chip is composed of six paralleled systems. Using the NSC injector design, the number of reservoirs in the multiplexed chip is reduced to N + 2, where N is the number of paralleled systems. This design feature radically reduces the complexity in chip structures and associated chip operation. The approach is applied to the analysis of fluorescently labelled biogenic amines affording detection at concentrations down to 20 pM.
- 20 December 2002
- Published by Wiley in Journal of Separation Science
- Vol. 25 (18) , 1346-1350
On.column pre‐concentration of alcohol dehydrogenase in capillary electrophoresis
The analysis of alcohol dehydrogenase (ADH) at low concentration using capillary electrophoresis is described. Several simple and effective ways to improve detection limits and sensitivity are investigated. These include large volume sample stacking, head column field amplified sample stacking, and sweeping. Results indicate that by using a combination of head‐column field amplified sample stacking and sweeping, fluorescently labelled alcohol dehydrogenase can be pre‐concentrated online by dissolving samples in water or other low conductivity matrices, and injecting into a high conductivity micellar buffer. The abrupt changes in conductivity cause narrowing of the analyte length and thus enhance the detection sensitivity. Combination of this approach with laser induced fluorescence detection yields a limit of detection of 5×10–13 M. Both qualitative and quantitative aspects of this method are investigated.
- 20 December 2002
- Published by Wiley in Journal of Separation Science
- Vol. 25 (18) , 1346-1350
On.column pre‐concentration of alcohol dehydrogenase in capillary electrophoresis
The analysis of alcohol dehydrogenase (ADH) at low concentration using capillary electrophoresis is described. Several simple and effective ways to improve detection limits and sensitivity are investigated. These include large volume sample stacking, head column field amplified sample stacking, and sweeping. Results indicate that by using a combination of head‐column field amplified sample stacking and sweeping, fluorescently labelled alcohol dehydrogenase can be pre‐concentrated online by dissolving samples in water or other low conductivity matrices, and injecting into a high conductivity micellar buffer. The abrupt changes in conductivity cause narrowing of the analyte length and thus enhance the detection sensitivity. Combination of this approach with laser induced fluorescence detection yields a limit of detection of 5×10–13 M. Both qualitative and quantitative aspects of this method are investigated.
- 7 August 2002
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 17,p. 1954-1955
Solution-phase electroluminescence
We report emissive devices exhibiting electroluminescence in the solution phase. The principle operating mechanism for these devices—direct electronic carrier injection from the electrodes into the carrier bands of the dissolved polymer—resembles that of a conventional solid-state organic light-emitting diode and is distinct from the solvent-mediated electrochemical devices recently reported by Chang et al.
- 7 August 2002
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 17,p. 1954-1955
Solution-phase electroluminescence
We report emissive devices exhibiting electroluminescence in the solution phase. The principle operating mechanism for these devices—direct electronic carrier injection from the electrodes into the carrier bands of the dissolved polymer—resembles that of a conventional solid-state organic light-emitting diode and is distinct from the solvent-mediated electrochemical devices recently reported by Chang et al.
- 1 June 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (11) , 1722-1730
A polydimethylsiloxane/glass capillary electrophoresis microchip for the analysis of biogenic amines using indirect fluorescence detection
A polydimethylsiloxane‐glass capillary microchip is fabricated for the rapid analysis of a mixture of common biogenic amines using indirect fluorescence detection. Using a running buffer of phosphate and 2‐propanol, and Rhodamine 110 as a background fluorophore, both co‐ionic and counter‐ionic systems are explored. Studies demonstrate the separation and analysis of cations using indirect fluorescence detection for the first time in a chip‐based system. Resulting electrophoretic separations are achieved within a few tens of seconds with detection limits of approximately 6 ν M. The reduced sample handling and rapid separations afforded by the coupling of indirect fluorescence detection with chip‐based capillary electrophoresis provide a highly efficient method for the analysis and detection of molecules not possessing a chromophore or fluorophore. Furthermore, limits of detection are on a par with reported chip‐based protocols that incorporate precolumn derivatisation with fluorescence detection. The current device circumvents lengthy sample preparation stages and therefore provides an attractive alternative technique for the analysis biogenic amines.
- 1 June 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (11) , 1722-1730
A polydimethylsiloxane/glass capillary electrophoresis microchip for the analysis of biogenic amines using indirect fluorescence detection
A polydimethylsiloxane‐glass capillary microchip is fabricated for the rapid analysis of a mixture of common biogenic amines using indirect fluorescence detection. Using a running buffer of phosphate and 2‐propanol, and Rhodamine 110 as a background fluorophore, both co‐ionic and counter‐ionic systems are explored. Studies demonstrate the separation and analysis of cations using indirect fluorescence detection for the first time in a chip‐based system. Resulting electrophoretic separations are achieved within a few tens of seconds with detection limits of approximately 6 ν M. The reduced sample handling and rapid separations afforded by the coupling of indirect fluorescence detection with chip‐based capillary electrophoresis provide a highly efficient method for the analysis and detection of molecules not possessing a chromophore or fluorophore. Furthermore, limits of detection are on a par with reported chip‐based protocols that incorporate precolumn derivatisation with fluorescence detection. The current device circumvents lengthy sample preparation stages and therefore provides an attractive alternative technique for the analysis biogenic amines.
- 23 April 2002
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 10,p. 1136-1137
Microfluidic routes to the controlled production of nanoparticlesElectronic supplementary information ESI available: image of the central portion of the micromixer chip. See http://www.rsc.org/suppdata/cc/b2/b202998g/
A microfluidic procedure for the controlled production of cadmium sulfide nanoparticles is described
- 23 April 2002
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 10,p. 1136-1137
Microfluidic routes to the controlled production of nanoparticlesElectronic supplementary information ESI available: image of the central portion of the micromixer chip. See http://www.rsc.org/suppdata/cc/b2/b202998g/
A microfluidic procedure for the controlled production of cadmium sulfide nanoparticles is described
- 22 January 2002
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 2 (1) , 5-7
On-chip generation and reaction of unstable intermediates—monolithic nanoreactors for diazonium chemistry: Azo dyes
Monolithic nanoreactors for the safe and expedient continuous synthesis of products requiring unstable intermediates were fabricated and tested by the synthesis of azo dyes under hydrodynamic pumping regimes.
- 22 January 2002
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 2 (1) , 5-7
On-chip generation and reaction of unstable intermediates—monolithic nanoreactors for diazonium chemistry: Azo dyes
Monolithic nanoreactors for the safe and expedient continuous synthesis of products requiring unstable intermediates were fabricated and tested by the synthesis of azo dyes under hydrodynamic pumping regimes.
- 8 December 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (1) , 12-13
Miniaturization
- 8 December 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (1) , 12-13
Miniaturization
- 6 November 2001
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 1 (2) , 148-152
A high-pressure interconnect for chemical microsystem applications
A PEEK interface for use in microfluidic applications is designed, fabricated and tested. The interface allows for the facile, non-permanent coupling of standard capillary tubing to silicon/glass micromixer chips. Importantly, the interface provides for a secure connection between capillary lines and chip reservoirs without the need for any adhesive materials. Furthermore, when used in conjunction with silicon/glass micromixer chips fluidic transport is stable over a wide range of volumetric flow rates (1–1500 μL min−1), and the entire construct can be rapidly assembled and disassembled at any time during the course of experimentation.
- 6 November 2001
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 1 (2) , 148-152
A high-pressure interconnect for chemical microsystem applications
A PEEK interface for use in microfluidic applications is designed, fabricated and tested. The interface allows for the facile, non-permanent coupling of standard capillary tubing to silicon/glass micromixer chips. Importantly, the interface provides for a secure connection between capillary lines and chip reservoirs without the need for any adhesive materials. Furthermore, when used in conjunction with silicon/glass micromixer chips fluidic transport is stable over a wide range of volumetric flow rates (1–1500 μL min−1), and the entire construct can be rapidly assembled and disassembled at any time during the course of experimentation.