Bernd Schäfer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bernd Schäfer has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Klaus Mann
Laser-Laboratorium Göttingen eV
5 shared publications- Klaus Mann
Laser-Lab. Goettingen eV (Germany)
4 shared publications Bernhard Flöter
Laser-Laboratorium Göttingen eV
3 shared publicationsTobias Mey
Laser-Laboratorium Göttingen eV
3 shared publicationsArmin Bayer
Laser-Laboratorium Göttingen, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany
1 shared publicationBarbara Keitel
Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22603 Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 7 April 2021
- Published by Springer Nature
- p. C1
Correction to: Wavefront and Coherence Characteristics of Extreme UV and Soft X-ray Sources
The book was inadvertently published with the error in the reference section of chapter 20. The correction detail is as follows:
- 7 April 2021
- Published by Springer Nature
- p. C1
Open AccessCorrection to: Wavefront and Coherence Characteristics of Extreme UV and Soft X-ray Sources
The book was inadvertently published with the error in the reference section of chapter 20. The correction detail is as follows:
- 24 June 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (9) , 523-534
Kombination eines neuartigen Doppelpuls-RGB-Interferometers mit einem Hartmann-Shack-Wellenfrontsensor zur dynamischen flächenhaften Topographieerfassung
Zusammenfassung: In diesem Beitrag wird ein Messsystem vorgestellt, das aus der Kombination eines phasenmessenden Interferometers mit einem Hartmann-Shack-Wellenfrontsensor besteht. Die beiden Sensoren nutzen einen gemeinsamen optischen Strahlengang einschließlich eines Mikroskobjektivs, das auf die zu messende Oberfläche gerichtet ist. Sie unterscheiden sich jedoch grundlegend in ihrer physikalischen Funktionsweise und ihren messtechnischen Eigenschaften. Der Wellenfrontsensor erfasst niederfrequente Ortsfrequenzanteile einer dreidimensionalen Oberflächentopographie mit einer vergleichsweise geringen Anzahl an Stützstellen anhand eines einzelnen monochromen Kamerabildes. Das Interferometer benötigt zwei RGB-Aufnahmen zur Rekonstruktion der Phasenkarte derselben Oberflächentopographie und erfasst dabei deutlich höhere Ortsfrequenzanteile, welche für die Rauheitsmessung erforderlich sind. Eine spezielle Doppelpuls-Beleuchtung in Verbindung mit einer periodischen Phasenmodulation ermöglicht die Akquisition der erforderlichen Interferogramme in ca. 50 µs. Die Kombination der Messergebnisse von Wellenfrontsensor und Interferometer ermöglicht den Verzicht auf störanfällige Unwrapping-Algorithmen und erhöht die Flexibilität und das Einsatzspektrum der Sensorkombination im Vergleich zu einem Einzelsensor. Die geringe Zeitdauer zur Erfassung der Topographie eines mikroskopischen Messfeldes erlaubt Messungen an bewegten Messobjekten und bildet damit eine wichtige Voraussetzung für den Einsatz des Sensorsystems in Produktionsanlagen. Die Funktionsweise und die praktische Realisierung des Sensors werden vorgestellt. Messergebnisse von verschiedenen Messobjekten zeigen das Potential dieser Sensorkombination und die jeweiligen Einschränkungen der beiden Sensoren auf.
- 24 June 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (9) , 523-534
Kombination eines neuartigen Doppelpuls-RGB-Interferometers mit einem Hartmann-Shack-Wellenfrontsensor zur dynamischen flächenhaften Topographieerfassung
Zusammenfassung: In diesem Beitrag wird ein Messsystem vorgestellt, das aus der Kombination eines phasenmessenden Interferometers mit einem Hartmann-Shack-Wellenfrontsensor besteht. Die beiden Sensoren nutzen einen gemeinsamen optischen Strahlengang einschließlich eines Mikroskobjektivs, das auf die zu messende Oberfläche gerichtet ist. Sie unterscheiden sich jedoch grundlegend in ihrer physikalischen Funktionsweise und ihren messtechnischen Eigenschaften. Der Wellenfrontsensor erfasst niederfrequente Ortsfrequenzanteile einer dreidimensionalen Oberflächentopographie mit einer vergleichsweise geringen Anzahl an Stützstellen anhand eines einzelnen monochromen Kamerabildes. Das Interferometer benötigt zwei RGB-Aufnahmen zur Rekonstruktion der Phasenkarte derselben Oberflächentopographie und erfasst dabei deutlich höhere Ortsfrequenzanteile, welche für die Rauheitsmessung erforderlich sind. Eine spezielle Doppelpuls-Beleuchtung in Verbindung mit einer periodischen Phasenmodulation ermöglicht die Akquisition der erforderlichen Interferogramme in ca. 50 µs. Die Kombination der Messergebnisse von Wellenfrontsensor und Interferometer ermöglicht den Verzicht auf störanfällige Unwrapping-Algorithmen und erhöht die Flexibilität und das Einsatzspektrum der Sensorkombination im Vergleich zu einem Einzelsensor. Die geringe Zeitdauer zur Erfassung der Topographie eines mikroskopischen Messfeldes erlaubt Messungen an bewegten Messobjekten und bildet damit eine wichtige Voraussetzung für den Einsatz des Sensorsystems in Produktionsanlagen. Die Funktionsweise und die praktische Realisierung des Sensors werden vorgestellt. Messergebnisse von verschiedenen Messobjekten zeigen das Potential dieser Sensorkombination und die jeweiligen Einschränkungen der beiden Sensoren auf.
- Open Access
- 10 June 2020
- Published by Springer Nature
- Vol. 134, 531-548
Wavefront and Coherence Characteristics of Extreme UV and Soft X-ray Sources
The first part of this chapter comprises setups and results of the determination of wavefront and beam parameters for different EUV sources (free-electron lasers, HHG-sources, synchrotron radiation) by self supporting Hartmann-Sensors. We present here i.a. a sensor applied for alignment of the ellipsodial mirror at FLASH beamline 2, yielding a reduction of the rms-wavefront aberrations by more than a factor of 3. In the second part we report on the characterization of the Free-Electron-Laser FLASH at DESY by a quantitative determination of the Wigner distribution function. The setup, comprising an ellipsodial mirror and a moveable extreme UV sensitive CCD detector, enables the mapping of two-dimensional phase space corresponding to the horizontal and vertical coordinate axes, respectively. Furthermore, an extended setup utilizing a torodial mirror for complete 4D-Wigner reconstruction has been accomplished and tested using radiation from a multimode Nd:VO4 laser.
- 10 June 2020
- Published by Springer Nature
- Vol. 134, 531-548
Open AccessWavefront and Coherence Characteristics of Extreme UV and Soft X-ray Sources
The first part of this chapter comprises setups and results of the determination of wavefront and beam parameters for different EUV sources (free-electron lasers, HHG-sources, synchrotron radiation) by self supporting Hartmann-Sensors. We present here i.a. a sensor applied for alignment of the ellipsodial mirror at FLASH beamline 2, yielding a reduction of the rms-wavefront aberrations by more than a factor of 3. In the second part we report on the characterization of the Free-Electron-Laser FLASH at DESY by a quantitative determination of the Wigner distribution function. The setup, comprising an ellipsodial mirror and a moveable extreme UV sensitive CCD detector, enables the mapping of two-dimensional phase space corresponding to the horizontal and vertical coordinate axes, respectively. Furthermore, an extended setup utilizing a torodial mirror for complete 4D-Wigner reconstruction has been accomplished and tested using radiation from a multimode Nd:VO4 laser.
- 16 November 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10805, 108052F
Spectrally resolved wavefront measurements on broad-band dielectric coatings
In this work the influence of non-uniformity effects on the spectral transmission properties of broad-band dielectric optical coatings was examined. Recently, it was observed that in modern complex dielectric coatings significant spectral, resonantlike errors of the reflected wavefront can occur at specific wavelengths, which are induced by lateral coating nonuniformities [1]. For a detailed investigation of this effect, a setup was developed for monitoring the spectrally dependent wavefront error, utilizing a broad-band monochromatized plasma lamp (spectral range from 400 – 900nm) as light source and a high sensitivity Hartmann-Shack wavefront sensor for detection of reflected or transmitted wavefronts. In addition, a method for absolute and relative calibration of the measured wavefront error is presented. Two broadband dielectric beam splitters (#1 and #2) deposited by magnetron sputtering (high reflectance 400 – 900 nm, high transmittance 920 – 2300 nm) with different coating specifications were analyzed. It could be shown, that for an optimized design the spectral wavefront error can be significantly reduced compared to a standard beam splitter design [2].
- 16 November 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10805, 108052F
Spectrally resolved wavefront measurements on broad-band dielectric coatings
In this work the influence of non-uniformity effects on the spectral transmission properties of broad-band dielectric optical coatings was examined. Recently, it was observed that in modern complex dielectric coatings significant spectral, resonantlike errors of the reflected wavefront can occur at specific wavelengths, which are induced by lateral coating nonuniformities [1]. For a detailed investigation of this effect, a setup was developed for monitoring the spectrally dependent wavefront error, utilizing a broad-band monochromatized plasma lamp (spectral range from 400 – 900nm) as light source and a high sensitivity Hartmann-Shack wavefront sensor for detection of reflected or transmitted wavefronts. In addition, a method for absolute and relative calibration of the measured wavefront error is presented. Two broadband dielectric beam splitters (#1 and #2) deposited by magnetron sputtering (high reflectance 400 – 900 nm, high transmittance 920 – 2300 nm) with different coating specifications were analyzed. It could be shown, that for an optimized design the spectral wavefront error can be significantly reduced compared to a standard beam splitter design [2].
- 9 October 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (21) , 25385-25396
Measurement and compensation of laser-induced wavefront deformations and focal shifts in near IR optics
We demonstrate the feasibility of passive compensation of the thermal lens effect in fused silica optics, placing suitable optical materials with negative dn/dT in the beam path of a high power near IR fiber laser. Following a brief overview of the involved mechanisms, photo-thermal absorption measurements with a Hartmann-Shack sensor are described, from which coefficients for surface/coating and bulk absorption in various materials are determined. Based on comprehensive knowledge of the 2D wavefront deformations resulting from absorption, passive compensation of thermally induced aberrations in complex optical systems is possible, as illustrated for an F-Theta objective. By means of caustic measurements during high-power operation we are able to demonstrate a 60% reduction of the focal shift in F-Theta lenses through passive compensation.
- 9 October 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (21) , 25385-25396
Measurement and compensation of laser-induced wavefront deformations and focal shifts in near IR optics
We demonstrate the feasibility of passive compensation of the thermal lens effect in fused silica optics, placing suitable optical materials with negative dn/dT in the beam path of a high power near IR fiber laser. Following a brief overview of the involved mechanisms, photo-thermal absorption measurements with a Hartmann-Shack sensor are described, from which coefficients for surface/coating and bulk absorption in various materials are determined. Based on comprehensive knowledge of the 2D wavefront deformations resulting from absorption, passive compensation of thermally induced aberrations in complex optical systems is possible, as illustrated for an F-Theta objective. By means of caustic measurements during high-power operation we are able to demonstrate a 60% reduction of the focal shift in F-Theta lenses through passive compensation.
- 1 October 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 654 (1) , 502-507
FEL beam characterization from measurements of the Wigner distribution function
- 1 October 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 654 (1) , 502-507
FEL beam characterization from measurements of the Wigner distribution function
- Open Access
- 27 September 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 21534-21539
Absolute measurement of surface and bulk absorption in DUV optics from temperature induced wavefront deformation.
A measurement system for quantitative determination of both surface and bulk contributions to the photo-thermal absorption in DUV optics was developed. It is based upon a Hartmann-Shack wavefront sensor with a sensitivity of ~λ/10000 rms, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted perpendicular through the excimer laser-irradiated site of a cuboid sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a cylindrical shape, with bending ends towards the surface. Sign and magnitude depend on index change and expansion. By comparison with thermal theory, this transient wavefront distortion yields a quantitative absolute measure of bulk and surface absorption losses in the sample. First rresults for fused silica are presented.
- 27 September 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 21534-21539
Open AccessAbsolute measurement of surface and bulk absorption in DUV optics from temperature induced wavefront deformation.
A measurement system for quantitative determination of both surface and bulk contributions to the photo-thermal absorption in DUV optics was developed. It is based upon a Hartmann-Shack wavefront sensor with a sensitivity of ~λ/10000 rms, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted perpendicular through the excimer laser-irradiated site of a cuboid sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a cylindrical shape, with bending ends towards the surface. Sign and magnitude depend on index change and expansion. By comparison with thermal theory, this transient wavefront distortion yields a quantitative absolute measure of bulk and surface absorption losses in the sample. First rresults for fused silica are presented.
- 2 December 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (25) , 23025-23036
Photo-thermal measurement of absorptance losses, temperature induced wavefront deformation and compaction in DUV-optics.
A measurement system for quantitative registration of transient and irreversible lens effects in DUV optics induced by absorbed UV laser radiation was developed. It is based upon a strongly improved Hartmann-Shack wavefront sensor with an extreme sensitivity of ~λ/10000 rms @ 193nm, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted through the laser-irradiated site of a sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a convex or concave lens, depending on sign and magnitude of index change and expansion. This transient wavefront distortion yields a quantitative measure of the absorption losses in the sample. In the case of fused silica, an additional permanent change indicates irreversible material compaction. Results for both fused silica and CaF2 are presented and compared.
- 2 December 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (25) , 23025-23036
Photo-thermal measurement of absorptance losses, temperature induced wavefront deformation and compaction in DUV-optics.
A measurement system for quantitative registration of transient and irreversible lens effects in DUV optics induced by absorbed UV laser radiation was developed. It is based upon a strongly improved Hartmann-Shack wavefront sensor with an extreme sensitivity of ~λ/10000 rms @ 193nm, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted through the laser-irradiated site of a sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a convex or concave lens, depending on sign and magnitude of index change and expansion. This transient wavefront distortion yields a quantitative measure of the absorption losses in the sample. In the case of fused silica, an additional permanent change indicates irreversible material compaction. Results for both fused silica and CaF2 are presented and compared.
- 1 July 2000
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 71 (7) , 2663-2668
Investigation of the propagation characteristics of excimer lasers using a Hartmann–Shack sensor
For wave front distribution measurements of excimer laser radiation, a Hartmann–Shack wave front sensor with 40×30 subapertures and a field of view adapted to the lateral laser beam profile was utilized. The peak-to-valley wave front resolution is λ/12 and the dynamic range 100λ per subaperture at 248 nm. Time-averaged propagation characteristics were determined for several combinations of resonator configuration and laser medium from the ns down to the fs pulse length regime. Above that, time-resolved measurements were carried out on a KrF excimer laser, showing a reduction of the beam divergence during the laser pulse by a factor of 1.6. This transient behavior is discussed on the basis of a simple geometrical model. The theoretical results are in qualitative agreement with the experiment.
- 1 July 2000
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 71 (7) , 2663-2668
Investigation of the propagation characteristics of excimer lasers using a Hartmann–Shack sensor
For wave front distribution measurements of excimer laser radiation, a Hartmann–Shack wave front sensor with 40×30 subapertures and a field of view adapted to the lateral laser beam profile was utilized. The peak-to-valley wave front resolution is λ/12 and the dynamic range 100λ per subaperture at 248 nm. Time-averaged propagation characteristics were determined for several combinations of resonator configuration and laser medium from the ns down to the fs pulse length regime. Above that, time-resolved measurements were carried out on a KrF excimer laser, showing a reduction of the beam divergence during the laser pulse by a factor of 1.6. This transient behavior is discussed on the basis of a simple geometrical model. The theoretical results are in qualitative agreement with the experiment.