RMR. Mehrez

R. Mehrez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R. Mehrez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Continuous measurement and control of fouling active compounds in membrane bioreactor systems

    by M. Ernst, R. Mehrez, A. Drews, V. Iversen, M. Kraume, M. Jekel

    For a more effective fouling reduction in membrane bioreactors (MBR) the approach of continuous measurement and control of protein and polysaccharide concentrations is followed. So called extra-cellular polymer substances (EPS) can be partially measured by a newly developed protein sensor based on sequential injection analysis. The sensor is validated by real MBR pilot data, stating the feasibility of the technique for continuous monitoring. Parallel to EPS, other fouling active compounds such as organic bio-polymer were determined in two parallel MBR pilot lines by size exclusion chromatography, proving desired comparable conditions in both lines for later parallel testing. The daily variation of EPS in MBR operation are moderate, where protein changes tend to react more pronounced to operational changes than polysaccharides. This was also the case for the organic bio-polymer fraction, especially in manipulated bench experiments at abruptly changing redox conditions.


  • Development of a continuous protein and polysaccharide measurement method by Sequential Injection Analysis for application in membrane bioreactor systems

    by R. Mehrez, M. Ernst, M. Jekel

    Polysaccharides and proteins are the main components of extracellular polymeric substances, which are considered to give a major contribution to the overall fouling potential of the MBR system. This work focuses on the automation of spectrophotometrical assays for protein and polysaccharide determination for on-line measurement in MBR. Sequential Injection Analysis (SIA) was identified as more suitable for continuous measurements. In screening tests the selection of an appropriate assay for the successful automation by means of SIA was carried out. Lowry Assay and Dubois Assay were chosen for protein and polysaccharide determination. Lowry Assay could be successfully automated by means of SIA. The automated method shows a lower sensitivity than the manual Lowry method, what can be contributed to specific characteristic of SIA. The confidence limit was calculated to 2.8 mg/L. The automated method shows in validation tests good correspondence with protein concentrations measured with the manual assay (R(2)=0.971). The successful establishment of the Dubois Assay for polysaccharides failed so far due to sensitivity problems.