WAWilliam C. Adams

William C. Adams

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Latest Publications

  • Comparison of Chamber 6.6-h Exposures to 0.04–0.08 PPM Ozone via Square-wave and Triangular Profiles on Pulmonary Responses

    by William C. Adams

    It has become increasingly well realized that laboratory simulations of air pollution risk assessment need to employ O3 concentration profiles that more accurately mimic those encountered during summer daylight ambient air pollution episodes. The present study was designed to compare the pulmonary function and symptoms of breathing discomfort responses to a 6.6-h square-wave 0.08-ppm O3 chamber exposure to those observed in a triangular O3 exposure profile (mean of 0.08 ppm), as well as to both a 0.06-ppm square-wave and triangular mean 0.06-ppm exposure, and to those observed during a triangular mean 0.04-ppm exposure and to a filtered air (FA) square-wave exposure. Thirty young adults (15 of each gender) served as subjects, each completing all exposures. While the 6.6-h postexposure responses to the acute triangular exposure to a mean O3 concentration of 0.08 ppm did not differ significantly from those observed in the square-wave exposure, forced expiratory volume in 1 s (FEV)1.0 and total symptoms severity (TSS) were significantly different from preexposure at 4.6 h (when O3 concentration was 0.15 ppm) in the triangular exposure, but not until 6.6 h in the square-wave exposure. Thus, significant pulmonary function and symptoms responses were observed over a longer period in the triangular exposure protocol at a mean O3 concentration of 0.08 ppm. These results support previous evidence that O3 concentration has a greater singular effect in the total inhaled O3 dose than do VE and exposure duration. Subtracting pulmonary function effects consequent to O3 exposure to existent 8-h average background levels (e.g., ∼0.04 ppm, rather than those observed in FA exposures) from those observed at higher concentrations (e.g., ∼0.08 ppm) represents a means of focusing the regulatory effort on effects that can be controlled. The greatest pulmonary function and symptoms responses observed for a 0.04-ppm triangular exposure were nearly the same as those for the FA square-wave exposure. Thus, results of the present study show that calculating the net pulmonary function effect of exposure to 0.08 ppm with “correction” for FA response, or for that incurred for 0.04 ppm O3, does not result in any statistically significant difference.


  • Comparison of Chamber and Face Mask 6.6-Hour Exposure to 0.08 ppm Ozone Via Square-Wave and Triangular Profiles on Pulmonary Responses

    by William C. Adams

    Recently, a stainless-steel air pollution chamber was acquired in this laboratory, and data were obtained in a study that convincingly demonstrated that chamber and face-mask inhalation methods of exposing young adult subjects for 6.6 h to nearly identical total inhaled O 3 doses at 0.12 ppm produced very similar pulmonary function, symptoms, and exercise ventilatory pattern responses. However, the results of a 6.6-h face-mask exposure to 0.08 ppm O 3, compared to some previous chamber exposure study results, revealed several small incongruities that may be due primarily to high individual subject "noise" in responses to a relatively low O 3 exposure. To resolve these differences, it was the primary purpose of this study to compare chamber exposure responses to those elicited via face-mask exposure to 0.08 ppm O 3 for 6.6 h with subjects serving as their own controls. Two types of O 3 exposure patterns were used: (1) the usual square-wave profile, and (2) an acute triangular profile, in which O 3 concentration was increased each hour from 0.03 ppm to 0.15 ppm during h 4 and then decreased each hour to 0.05 ppm (mean = 0.08 ppm). Thirty young adults (15 of each gender) served as subjects. The two exposure methods (i.e., face mask and chamber) yielded near identical total inhaled O 3 doses in both the square-wave and triangular exposure profiles, and produced very similar postexposure pulmonary function, symptoms, and exercise ventilatory pattern responses. However, pulmonary function and symptoms responses became statistically significant from preexposure at the end of h 4 (when [O 3] = 0.15 ppm) in the triangular protocols, but not until h 6 in the square-wave protocols. These results support previous evidence that O 3 concentration has a greater singular effect in the total inhaled O 3 dose than do V E and exposure duration.


  • COMPARISON OF CHAMBER AND FACE-MASK 6.6-HOUR EXPOSURES TO OZONE ON PULMONARY FUNCTION AND SYMPTOMS RESPONSES

    by William C. Adams

    Because of increased interest in an 8-h ozone (O(3)) federal air quality standard, acute pulmonary function responses to prolonged square-wave O(3) exposure between 0.08 and 0.12 ppm have been examined in several U.S. Environmental Protection Agency (EPA) chamber studies. A low-cost face-mask O(3) exposure system was developed in this laboratory and found to produce closely similar pulmonary responses to those observed in prolonged exposures by U.S. EPA investigators. The primary purpose of the present study was to investigate the pulmonary function and subjective symptoms effects of 6.6-h square-wave exposure to 0.12 ppm O(3) by these two methods using the same group of subjects. In addition, further investigation of pulmonary function and symptoms responses upon 6.6-h exposures to lower levels of O(3) (0.04-0.08 ppm) were studied with the face-mask inhalation system. Thirty young adult subjects completed five 6.6-h exposures with six 50-min periods of exercise at an intensity requiring a minute ventilation rate (V(E)) of ~20 L/min/m2 of body surface area, each followed by 10 min of rest, except following 3 h when the rest period was lengthened for a lunch break. The total O(3) doses for the chamber and face-mask exposures to 0.12 ppm O(3) were not significantly different from each other, since the additional O(3) dose during the 35 min lunch break in the chamber exposure was offset by a slightly lower average exercise V(E) (i.e., 19.1 L/min/m2). The data convincingly demonstrated that the two methods of exposing young adults to nearly identical total inhaled O(3) doses at 0.12 ppm produce very similar pulmonary function, symptoms, and exercise ventilatory pattern responses. On the other hand, results of the 6.6-h face-mask exposures to 0.08 ppm O(3) in the present study, compared to similar U.S. EPA exposure study results, revealed several incongruities that may be due primarily to high individual subject variability in responses to a relatively low O(3) exposure. Thus, a comparison of chamber exposure responses to those elicited via face-mask exposure to 0.08 ppm O(3) in the same subject group seems warranted.


  • Ozone dose–response effects of varied equivalent minute ventilation rates

    by William C Adams

    While it is well known that exercise minute ventilation (VE) results in greater pulmonary function and subjective symptoms (SS) responses upon exposure to a given ozone (O3) dose, the magnitude of VE increase to produce a significant forced expiratory volume in 1 s (FEV1.0) response compared to that observed at a lower exercise VE for the same O3 concentration and exposure time is unclear, especially in prolonged (i.e., >2 h) exposures. Further, in prolonged exposures, the relationship of body size to FEV1.0 response to a given O3 exposure dose has not been systematically examined. In the present study, 30 young adults were exposed on four occasions for 6 h (during a 6.6-h period) to constant O3 levels of zero (filtered air, FA) or 0.12 parts per million (ppm). At the latter concentration, exercise VE was varied in exposures to 17, 20, and 23 l min-1 m-2 of BSA, respectively, for each individual to achieve an equivalent ventilation rate, EVR). In the FA exposure, EVR was 23 l min-1 m2. Percent changes in FEV1.0 for the three 0.12 ppm O3 exposures were significantly greater than that for FA, but did not differ significantly from each other. For the 6.6-h exposures, exercise EVR at or in excess of 17 l min-1 m-2, SS values were significantly greater than those observed for the FA protocol. Further, SS values at 6.6 h of exposure to 0.12 ppm O3 for the exercise EVR of 23 l min-1 m-2 protocol were significantly greater than for the 0.12 ppm O3 exercise EVR of 17 l min-1 m-2 protocol. To achieve a widened EVR, two 1-h exposures to 0.30 ppm O3 with continuous exercise (CE) at a level necessitating an EVR of 17 and 34 l min-1 m-2, respectively, were completed by each subject. All postexposure pulmonary function and SS responses were significantly greater for the higher 1-h EVR protocol. In all exposures with significant O3-induced changes in FEV1.0 and SS, it was found that the smaller subjects who exercised at the lowest absolute VE had significantly smaller responses than did the larger subjects. These results strongly suggest that for the O3 concentrations and exposure durations used in this study, the effect of VE on O3-induced FEV1.0 and SS responses is not body-size-dependent.


  • FEASIBILITY STUDY OF PROLONGED OZONE INHALATION EXPOSURE VIA FACE MASK

    by William C. Adams

    Because of the interest attendant to establishing an 8-h ozone (O3) federal air quality standard, acute pulmonary function responses to prolonged (6.6 to 8 h) O3 exposure between 0.08 and 0.24 ppm have been examined in chamber studies. Given time constraints for O3 concentration changes in room-sized chambers and the need to simulate rapid fluctuations in O3 levels, such as occurs when one goes from indoors to outdoors during an air pollution episode, mouthpiece or face-mask exposure systems offer potential advantages over chamber exposure systems. In a recent study in this laboratory, subjects indicated that over 2 h of continuous exposure via an obligatory mouthpiece inhalation system (with noseclip) was more than they could tolerate with this type of exposure system. The purpose of this study was to compare O3-induced responses observed following 2-h exposures via an obligatory mouthpiece inhalation system and a newly devised face-mask exposure system, and to determine whether the latter could be tolerated during 4-h exposures. Six young adults completed 5 experimental protocols (three 2-h and two 4-h) while exposed to O3 concentrations ranging from 0.00 ppm (filtered air) to 0.24 ppm. Exercise and resting minute ventilation (VE) were measured continuously. Pulmonary function, subjective symptoms (SS) of breathing discomfort, and exercise ventilatory pattern responses were obtained. Exposure to 0.24 ppm O3 with intermittent exercise (IE) for 2 h via a newly devised inhalation system, consisting of a nylon plastic non-rebreathing respiratory valve and a silicone rubber face mask with Teflon overlay on the inner surface, yielded pulmonary function, SS, and exercise ventilatory pattern responses nearly identical to those obtained in the same O3 exposure effected via a Teflon-coated Hans-Rudolph respiratory valve obligatory mouthpiece inhalation system. It was concluded that the newly devised face-mask inhalation system was well tolerated by all subjects during the 4-h exposure protocols, with each subject indicating that longer 6.6-h exposures with this system would be tolerable.