Alan M. Kalet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alan M. Kalet has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Mark H. Phillips
Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA, 98195, USA
3 shared publications- Juergen Meyer
Department of Radiation Oncology, Fred Hutchinson Cancer Center University of Washington Seattle Washington USA
2 shared publications Myra A. Lavilla
Department of Radiation Oncology, Seattle Cancer Care Alliance, Seattle, WA, United States of America
2 shared publicationsAngelia Landers
Department of Radiation Oncology, University of Washington, Seattle, WA, United States of America; Department of Radiation Oncology, Seattle Cancer Care Alliance, Seattle, WA, United States of America
1 shared publicationChristine L. Fang
Department of Radiation Oncology, University of Washington, Seattle, WA, United States of America; Department of Radiation Oncology, Seattle Cancer Care Alliance, Seattle, WA, United States of America
1 shared publicationClaire Dempsey
Department of Radiation Oncology, University of Washington, Seattle, Washington; Seattle Cancer Care Alliance, Seattle, Washington
1 shared publication
Latest Publications
- 11 August 2022
- Published by Elsevier in Physica Medica
- Vol. 101, 62-70
Automated planning stage tracking and analysis through an integrated whiteboard system
- 11 August 2022
- Published by Elsevier in Physica Medica
- Vol. 101, 62-70
Automated planning stage tracking and analysis through an integrated whiteboard system
- Open Access
- 15 February 2019
- Published by Wiley in Medical Physics
- Vol. 47 (5) , E168-E177
Radiation Therapy Quality Assurance Tasks and Tools: The Many Roles of Machine Learning
The recent explosion in machine learning efforts in the quality assurance (QA) space has produced a variety of proofs‐of‐concept many with promising results. Expected outcomes of model implementation include improvements in planning time, plan quality, advanced dosimetric QA, predictive machine maintenance, increased safety checks, and developments key for new QA paradigms driven by adaptive planning. In this article, we outline several areas of research and discuss some of the unique challenges each area presents.
- 15 February 2019
- Published by Wiley in Medical Physics
- Vol. 47 (5) , E168-E177
Open AccessRadiation Therapy Quality Assurance Tasks and Tools: The Many Roles of Machine Learning
The recent explosion in machine learning efforts in the quality assurance (QA) space has produced a variety of proofs‐of‐concept many with promising results. Expected outcomes of model implementation include improvements in planning time, plan quality, advanced dosimetric QA, predictive machine maintenance, increased safety checks, and developments key for new QA paradigms driven by adaptive planning. In this article, we outline several areas of research and discuss some of the unique challenges each area presents.
- 30 June 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4350-4359
Developing Bayesian networks from a dependency‐layered ontology: A proof‐of‐concept in radiation oncology
Purpose: Bayesian networks (BNs) are graphical representations of probabilistic knowledge that offer normative reasoning under uncertainty and are well suited for use in medical domains. Traditional knowledge‐based network development of BN topology requires that modeling experts establish relevant dependency links between domain concepts by searching and translating published literature, querying domain experts, or applying machine learning algorithms on data. For initial development these methods are time‐intensive and this cost hinders the growth of BN applications in medical decision making. Further, this approach fails to utilize knowledge representation in medical fields to automate network development. Our research alleviates the challenges surrounding BN modeling in radiation oncology by leveraging an ontology based hub and spoke system for BN construction.Methods: We implement a hub and spoke system by developing (a) an ontology of knowledge in radiation oncology (the hub) which includes dependency semantics similar to BN relations and (b) a software tool that operates on ontological semantics using deductive reasoning to create BN topologies (the spokes). We demonstrate that network topologies built using the software are terminologically consistent and form networks that are topologically compatible with existing ones. We do this first by merging two different BN models for prostate cancer radiotherapy prediction which contain domain cross terms. We then use the logic to perform discovery of new causal chains between radiation oncology concepts.Results: From the radiation oncology (RO) ontology we successfully reconstructed a previously published prostate cancer radiotherapy Bayes net using up‐to‐date domain knowledge. Merging this model with another similar prostate cancer model in the RO domain produced a larger, highly interconnected model representing the expanded scope of knowledge available regarding prostate cancer therapy parameters, complications, and outcomes. The causal discovery resulted in an automatically‐built causal network model of all ontologized radiotherapy concepts between a ‘Mucositis’ complication and anatomic tumor location.Conclusions: The proposed model building approach lowers barriers to developing probabilistic models relevant to real‐world clinical decision making, and offers a solution to the consistency and compatibility problems. Further, the knowledge representation in this work demonstrates potential for broader radiation oncology applications outside of Bayes nets.
- 30 June 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4350-4359
Developing Bayesian networks from a dependency‐layered ontology: A proof‐of‐concept in radiation oncology
Purpose: Bayesian networks (BNs) are graphical representations of probabilistic knowledge that offer normative reasoning under uncertainty and are well suited for use in medical domains. Traditional knowledge‐based network development of BN topology requires that modeling experts establish relevant dependency links between domain concepts by searching and translating published literature, querying domain experts, or applying machine learning algorithms on data. For initial development these methods are time‐intensive and this cost hinders the growth of BN applications in medical decision making. Further, this approach fails to utilize knowledge representation in medical fields to automate network development. Our research alleviates the challenges surrounding BN modeling in radiation oncology by leveraging an ontology based hub and spoke system for BN construction.Methods: We implement a hub and spoke system by developing (a) an ontology of knowledge in radiation oncology (the hub) which includes dependency semantics similar to BN relations and (b) a software tool that operates on ontological semantics using deductive reasoning to create BN topologies (the spokes). We demonstrate that network topologies built using the software are terminologically consistent and form networks that are topologically compatible with existing ones. We do this first by merging two different BN models for prostate cancer radiotherapy prediction which contain domain cross terms. We then use the logic to perform discovery of new causal chains between radiation oncology concepts.Results: From the radiation oncology (RO) ontology we successfully reconstructed a previously published prostate cancer radiotherapy Bayes net using up‐to‐date domain knowledge. Merging this model with another similar prostate cancer model in the RO domain produced a larger, highly interconnected model representing the expanded scope of knowledge available regarding prostate cancer therapy parameters, complications, and outcomes. The causal discovery resulted in an automatically‐built causal network model of all ontologized radiotherapy concepts between a ‘Mucositis’ complication and anatomic tumor location.Conclusions: The proposed model building approach lowers barriers to developing probabilistic models relevant to real‐world clinical decision making, and offers a solution to the consistency and compatibility problems. Further, the knowledge representation in this work demonstrates potential for broader radiation oncology applications outside of Bayes nets.
- 1 January 2017
- Published by Elsevier in Medical Dosimetry
- Vol. 42 (2) , 122-125
Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system
- 1 January 2017
- Published by Elsevier in Medical Dosimetry
- Vol. 42 (2) , 122-125
Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system
- Open Access
- 4 November 2013
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 14 (6) , 133-154
Validation of the photon convolution‐superposition algorithm applied to fast neutron beams
We evaluate a photon convolution-superposition algorithm used to model a fast neutron therapy beam in a commercial treatment planning system (TPS). The neutron beam modeled was the Clinical Neutron Therapy System (CNTS) fast neutron beam produced by 50 MeV protons on a Be target at our facility, and we implemented the dose calculation model for computing neutron doses. Measured neutron data were acquired by an IC30 ion chamber flowing 5 cc/min of tissue equivalent gas. Output factors and profile scans for open and wedged fields were measured according to the Pinnacle physics reference guide recommendations for photon beams in a Wellhofer water tank scanning system. Following the construction of a neutron beam model, computed doses were then generated using 100 monitor units (MUs) beams incident on a water-equivalent phantom for open and wedged square fields, as well as multileaf collimator (MLC)-shaped irregular fields. We compared Pinnacle dose profiles, central axis doses, and off-axis doses (in irregular fields) with 1) doses computed using the Prism treatment planning system, and 2) doses measured in a water phantom and having matching geometry to the computation setup. We found that the Pinnacle photon model may be used to model most of the important dosimetric features of the CNTS fast neutron beam. Pinnacle-calculated dose points among open and wedged square fields exhibit dose differences within 3.9 cGy of both Prism and measured doses along the central axis, and within 5 cGy difference of measurement in the penumbra region. Pinnacle dose point calculations using irregular treatment type fields showed a dose difference up to 9 cGy from measured dose points, although most points of comparison were below 5 cGy. Comparisons of dose points that were chosen from cases planned in both Pinnacle and Prism show an average dose difference less than 0.6%, except in certain fields which incorporate both wedges and heavy blocking of the central axis. All clinical cases planned in both Prism and Pinnacle were found to be comparable in terms of dose-volume histograms and spatial dose distribution following review by the treating clinicians. Variations were considered minor and within clinically acceptable limits by the treating clinicians. The Pinnacle TPS has sufficient computational modeling ability to adequately produce a viable neutron model for clinical use in treatment planning. PACS numbers: 87.53 Bn, 28.20.Pr, 87.53.Bn- 4 November 2013
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 14 (6) , 133-154
Open AccessValidation of the photon convolution‐superposition algorithm applied to fast neutron beams
We evaluate a photon convolution-superposition algorithm used to model a fast neutron therapy beam in a commercial treatment planning system (TPS). The neutron beam modeled was the Clinical Neutron Therapy System (CNTS) fast neutron beam produced by 50 MeV protons on a Be target at our facility, and we implemented the dose calculation model for computing neutron doses. Measured neutron data were acquired by an IC30 ion chamber flowing 5 cc/min of tissue equivalent gas. Output factors and profile scans for open and wedged fields were measured according to the Pinnacle physics reference guide recommendations for photon beams in a Wellhofer water tank scanning system. Following the construction of a neutron beam model, computed doses were then generated using 100 monitor units (MUs) beams incident on a water-equivalent phantom for open and wedged square fields, as well as multileaf collimator (MLC)-shaped irregular fields. We compared Pinnacle dose profiles, central axis doses, and off-axis doses (in irregular fields) with 1) doses computed using the Prism treatment planning system, and 2) doses measured in a water phantom and having matching geometry to the computation setup. We found that the Pinnacle photon model may be used to model most of the important dosimetric features of the CNTS fast neutron beam. Pinnacle-calculated dose points among open and wedged square fields exhibit dose differences within 3.9 cGy of both Prism and measured doses along the central axis, and within 5 cGy difference of measurement in the penumbra region. Pinnacle dose point calculations using irregular treatment type fields showed a dose difference up to 9 cGy from measured dose points, although most points of comparison were below 5 cGy. Comparisons of dose points that were chosen from cases planned in both Pinnacle and Prism show an average dose difference less than 0.6%, except in certain fields which incorporate both wedges and heavy blocking of the central axis. All clinical cases planned in both Prism and Pinnacle were found to be comparable in terms of dose-volume histograms and spatial dose distribution following review by the treating clinicians. Variations were considered minor and within clinically acceptable limits by the treating clinicians. The Pinnacle TPS has sufficient computational modeling ability to adequately produce a viable neutron model for clinical use in treatment planning. PACS numbers: 87.53 Bn, 28.20.Pr, 87.53.Bn - 26 November 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (24) , 7615-7631
A state-based probabilistic model for tumor respiratory motion prediction
This work proposes a new probabilistic mathematical model for predicting tumor motion and position based on a finite state representation using the natural breathing states of exhale, inhale and end of exhale. Tumor motion was broken down into linear breathing states and sequences of states. Breathing state sequences and the observables representing those sequences were analyzed using a hidden Markov model (HMM) to predict the future sequences and new observables. Velocities and other parameters were clustered using a k-means clustering algorithm to associate each state with a set of observables such that a prediction of state also enables a prediction of tumor velocity. A time average model with predictions based on average past state lengths was also computed. State sequences which are known a priori to fit the data were fed into the HMM algorithm to set a theoretical limit of the predictive power of the model. The effectiveness of the presented probabilistic model has been evaluated for gated radiation therapy based on previously tracked tumor motion in four lung cancer patients. Positional prediction accuracy is compared with actual position in terms of the overall RMS errors. Various system delays, ranging from 33 to 1000 ms, were tested. Previous studies have shown duty cycles for latencies of 33 and 200 ms at around 90% and 80%, respectively, for linear, no prediction, Kalman filter and ANN methods as averaged over multiple patients. At 1000 ms, the previously reported duty cycles range from approximately 62% (ANN) down to 34% (no prediction). Average duty cycle for the HMM method was found to be 100% and 91 +/- 3% for 33 and 200 ms latency and around 40% for 1000 ms latency in three out of four breathing motion traces. RMS errors were found to be lower than linear and no prediction methods at latencies of 1000 ms. The results show that for system latencies longer than 400 ms, the time average HMM prediction outperforms linear, no prediction, and the more general HMM-type predictive models. RMS errors for the time average model approach the theoretical limit of the HMM, and predicted state sequences are well correlated with sequences known to fit the data.
- 26 November 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (24) , 7615-7631
A state-based probabilistic model for tumor respiratory motion prediction
This work proposes a new probabilistic mathematical model for predicting tumor motion and position based on a finite state representation using the natural breathing states of exhale, inhale and end of exhale. Tumor motion was broken down into linear breathing states and sequences of states. Breathing state sequences and the observables representing those sequences were analyzed using a hidden Markov model (HMM) to predict the future sequences and new observables. Velocities and other parameters were clustered using a k-means clustering algorithm to associate each state with a set of observables such that a prediction of state also enables a prediction of tumor velocity. A time average model with predictions based on average past state lengths was also computed. State sequences which are known a priori to fit the data were fed into the HMM algorithm to set a theoretical limit of the predictive power of the model. The effectiveness of the presented probabilistic model has been evaluated for gated radiation therapy based on previously tracked tumor motion in four lung cancer patients. Positional prediction accuracy is compared with actual position in terms of the overall RMS errors. Various system delays, ranging from 33 to 1000 ms, were tested. Previous studies have shown duty cycles for latencies of 33 and 200 ms at around 90% and 80%, respectively, for linear, no prediction, Kalman filter and ANN methods as averaged over multiple patients. At 1000 ms, the previously reported duty cycles range from approximately 62% (ANN) down to 34% (no prediction). Average duty cycle for the HMM method was found to be 100% and 91 +/- 3% for 33 and 200 ms latency and around 40% for 1000 ms latency in three out of four breathing motion traces. RMS errors were found to be lower than linear and no prediction methods at latencies of 1000 ms. The results show that for system latencies longer than 400 ms, the time average HMM prediction outperforms linear, no prediction, and the more general HMM-type predictive models. RMS errors for the time average model approach the theoretical limit of the HMM, and predicted state sequences are well correlated with sequences known to fit the data.