Stefan H. Hohnloser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan H. Hohnloser has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Carsten W. Israel
From the Department of Medicine, Division of Cardiology, Section Clinical Electrophysiology, J. W. Goethe University, Frankfurt, Germany
11 shared publicationsGerian Grönefeld
Department of Medicine, Division of Cardiology, J.W. Goethe‐University, Frankfurt, Germany
7 shared publicationsYi‐Gang Li
Department of Medicine, Division of Cardiology, J.W. Goethe-University, Frankfurt, Germany
7 shared publicationsGabor Z. Duray
Department of Cardiology, Division of Clinical Electrophysiology, J.W. Goethe University, Frankfurt, Germany
4 shared publicationsGerian C. Grönefeld
University Hospital Frankfurt, Frankfurt, Germany
4 shared publicationsThomas Klingenheben
Division of Clinical Electrophysiology, Department of Cardiology, J.W. Goethe University, D-60590 Frankfurt, Germany
4 shared publications
Latest Publications
- 1 April 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (9) , 1018-1022
Insulation Defects of Thin High-Voltage ICD Leads:
Long-term lead failure is a known complication of ICD therapy. The precise incidence and sequelae of insulation defects at the tricuspid level, however, are not well characterized. This study determined the risk of lead failure, with particular emphasis on insulation defects at the level of the tricuspid valve, in a large series of consecutive ICD recipients. Data from 357 consecutive patients, who had received transvenous 7 and 8 French ICD-leads (St. Jude Medical, Riata family) and were followed at our center, formed the basis of this study. During a mean follow-up of 42 ± 24 months, 30 of 357 (8%) patients required surgical intervention due to lead failure. For overall lead defects, lead access via the subclavian vein and subpectoral device placement were independent predictors of overall lead failure (OR 3.47, 95% CI 1.38-8.72, P = 0.013 and OR 3.83, 95% CI 1.77-8.27, P = 0.001, respectively). Lead insulation defects at the level of the tricuspid valve accounted for 20% of all lead failures. Diagnosis of this specific insulation defect could only be established by fluoroscopy, while electrical parameters were within normal limits in all of these patients. On univariate but not on multivariate analysis the presence of nonischemic cardiomyopathy was a predictor of this lead complication (OR 8.2, CI 1.5-46.1, P = 0.02). Insulation defects of 7 and 8 French ICD leads at the tricuspid level represent an important complication of device therapy. Even moderate changes in lead impedance within the normal limits at follow-up should prompt careful fluoroscopic evaluation to avoid spurious shocks.
- 1 April 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (9) , 1018-1022
Insulation Defects of Thin High-Voltage ICD Leads:
Long-term lead failure is a known complication of ICD therapy. The precise incidence and sequelae of insulation defects at the tricuspid level, however, are not well characterized. This study determined the risk of lead failure, with particular emphasis on insulation defects at the level of the tricuspid valve, in a large series of consecutive ICD recipients. Data from 357 consecutive patients, who had received transvenous 7 and 8 French ICD-leads (St. Jude Medical, Riata family) and were followed at our center, formed the basis of this study. During a mean follow-up of 42 ± 24 months, 30 of 357 (8%) patients required surgical intervention due to lead failure. For overall lead defects, lead access via the subclavian vein and subpectoral device placement were independent predictors of overall lead failure (OR 3.47, 95% CI 1.38-8.72, P = 0.013 and OR 3.83, 95% CI 1.77-8.27, P = 0.001, respectively). Lead insulation defects at the level of the tricuspid valve accounted for 20% of all lead failures. Diagnosis of this specific insulation defect could only be established by fluoroscopy, while electrical parameters were within normal limits in all of these patients. On univariate but not on multivariate analysis the presence of nonischemic cardiomyopathy was a predictor of this lead complication (OR 8.2, CI 1.5-46.1, P = 0.02). Insulation defects of 7 and 8 French ICD leads at the tricuspid level represent an important complication of device therapy. Even moderate changes in lead impedance within the normal limits at follow-up should prompt careful fluoroscopic evaluation to avoid spurious shocks.
- 2 February 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (7) , 770-776
Effects of Dronedarone on Clinical Outcomes in Patients with Lone Atrial Fibrillation: Pooled Post Hoc Analysis from the ATHENA/EURIDIS/ADONIS Studies
Dronedarone has been shown to reduce cardiovascular hospitalizations or death in patients with atrial fibrillation (AF) and additional risk factors. This post hoc exploratory analysis examines its effects in the subgroup of lone AF patients. Individual data from patients with lone AF enrolled in the EURIDIS, ADONIS, and ATHENA trials were entered in a central database. The effects of dronedarone compared to placebo on the composite endpoint of cardiovascular hospitalizations or death, and their individual components, were evaluated. A total of 432 (192 placebo and 240 dronedarone) patients (7% of the total population) were classified as having lone AF (69.4% male patients, mean age 64 ± 13 years). The patients were followed for 13.8 ± 7.2 months. The risk for first cardiovascular hospitalizations or death from any cause in the placebo group after 1 year was 25% in the lone AF group compared to 29% the rest of the population. For patients with lone AF, dronedarone led to a 44% reduction of cardiovascular hospitalizations or death (hazard ratio (HR) 0.56; 95%CI 0.36-0.88, P = 0.004) and to a 46% reduction in cardiovascular hospitalizations alone (HR 0.54; 95%CI 0.34-0.87, P = 0.004) compared to placebo. HR for all-cause mortality was 1.02 (95%CI 0.31-3.34, P = 0.885). All findings were homogeneous across the 3 studies and similar to those observed in the overall population. According to this post hoc analysis, patients with lone AF have a high risk for cardiovascular hospitalization within 1 year. Dronedarone when added to standard of care reduces the risk of cardiovascular hospitalizations in this population.
- 2 February 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (7) , 770-776
Effects of Dronedarone on Clinical Outcomes in Patients with Lone Atrial Fibrillation: Pooled Post Hoc Analysis from the ATHENA/EURIDIS/ADONIS Studies
Dronedarone has been shown to reduce cardiovascular hospitalizations or death in patients with atrial fibrillation (AF) and additional risk factors. This post hoc exploratory analysis examines its effects in the subgroup of lone AF patients. Individual data from patients with lone AF enrolled in the EURIDIS, ADONIS, and ATHENA trials were entered in a central database. The effects of dronedarone compared to placebo on the composite endpoint of cardiovascular hospitalizations or death, and their individual components, were evaluated. A total of 432 (192 placebo and 240 dronedarone) patients (7% of the total population) were classified as having lone AF (69.4% male patients, mean age 64 ± 13 years). The patients were followed for 13.8 ± 7.2 months. The risk for first cardiovascular hospitalizations or death from any cause in the placebo group after 1 year was 25% in the lone AF group compared to 29% the rest of the population. For patients with lone AF, dronedarone led to a 44% reduction of cardiovascular hospitalizations or death (hazard ratio (HR) 0.56; 95%CI 0.36-0.88, P = 0.004) and to a 46% reduction in cardiovascular hospitalizations alone (HR 0.54; 95%CI 0.34-0.87, P = 0.004) compared to placebo. HR for all-cause mortality was 1.02 (95%CI 0.31-3.34, P = 0.885). All findings were homogeneous across the 3 studies and similar to those observed in the overall population. According to this post hoc analysis, patients with lone AF have a high risk for cardiovascular hospitalization within 1 year. Dronedarone when added to standard of care reduces the risk of cardiovascular hospitalizations in this population.
- 26 January 2010
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 21 (2) , 183-185
Defibrillation Testing: The Need for a Definitive Trial
- 26 January 2010
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 21 (2) , 183-185
Defibrillation Testing: The Need for a Definitive Trial
- 20 September 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (10) , 1043-1044
Risk Stratification Using T‐Wave Alternans: More Questions Waiting to be Answered
- 20 September 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (10) , 1043-1044
Risk Stratification Using T‐Wave Alternans: More Questions Waiting to be Answered
- 1 May 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (5) , 489-494
Coronary Sinus Side Branches for Cardiac Resynchronization Therapy: Prospective Evaluation of Availability, Implant Success, and Procedural Determinants
There are only sparse data concerning individual coronary side branch (CS-SB) anatomy with respect to LV lead implantation for cardiac resynchronization therapy (CRT). In patients (pts) undergoing CRT device implantation, a detailed venogram was obtained, and the CS-SB of first, second, third, and fourth choices for CS-lead implantation was defined. Study endpoints included successful LV lead implantation in the first choice CS-SB, number of CS-SB potentially available, implantation success in selected CS-SB, procedural variables, and 6-month response to CRT. CRT defibrillator implantation was attempted in 77 pts. Only 1 suitable CS-SB was present in 3 (4%), 2 in 20 (26%), 3 in 36 (47%), and 4 CS-SB in 18 patients (23%). The LV lead was implanted in the first choice CS-SB in 71% of patients, in the second choice in 16%, in the third choice in 3%. In 4 patients (5%) no LV lead could be implanted. Implant success was similar for different CS-SB regions (P = ns). Successful LV lead implantation in the CS-SB of first choice was associated with median fluoroscopy and procedure times of 20 +/- 13 and 143 +/- 41 minutes. Corresponding times for the CS-SB of >or= second choice were 38 +/- 21 (P = 0.002) and 179 +/- 47 minutes (P = 0.002). Response rate at 6 months was 64% for patients with LV leads in the first target CS-SB. In 70% of patients undergoing CRT device implantation, at least three suitable CS-SBs are available. Implant success in the CS-SB of first choice is 71% without significant differences for any particular CS-SB region.
- 1 May 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (5) , 489-494
Coronary Sinus Side Branches for Cardiac Resynchronization Therapy: Prospective Evaluation of Availability, Implant Success, and Procedural Determinants
There are only sparse data concerning individual coronary side branch (CS-SB) anatomy with respect to LV lead implantation for cardiac resynchronization therapy (CRT). In patients (pts) undergoing CRT device implantation, a detailed venogram was obtained, and the CS-SB of first, second, third, and fourth choices for CS-lead implantation was defined. Study endpoints included successful LV lead implantation in the first choice CS-SB, number of CS-SB potentially available, implantation success in selected CS-SB, procedural variables, and 6-month response to CRT. CRT defibrillator implantation was attempted in 77 pts. Only 1 suitable CS-SB was present in 3 (4%), 2 in 20 (26%), 3 in 36 (47%), and 4 CS-SB in 18 patients (23%). The LV lead was implanted in the first choice CS-SB in 71% of patients, in the second choice in 16%, in the third choice in 3%. In 4 patients (5%) no LV lead could be implanted. Implant success was similar for different CS-SB regions (P = ns). Successful LV lead implantation in the CS-SB of first choice was associated with median fluoroscopy and procedure times of 20 +/- 13 and 143 +/- 41 minutes. Corresponding times for the CS-SB of >or= second choice were 38 +/- 21 (P = 0.002) and 179 +/- 47 minutes (P = 0.002). Response rate at 6 months was 64% for patients with LV leads in the first target CS-SB. In 70% of patients undergoing CRT device implantation, at least three suitable CS-SBs are available. Implant success in the CS-SB of first choice is 71% without significant differences for any particular CS-SB region.
- 3 August 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (s2) , S17-S20
Dronedarone: An Emerging Agent with Rhythm‐ and Rate‐Controlling Effects
Of current antiarrhythmic agents, amiodarone is among the most effective with the additional advantage of having little proarrhythmic potential. However, it can cause potentially serious extracardiac side effects, stimulating the search for safer derivatives. Dronedarone, a new antiarrhythmic drug that is structurally related to amiodarone, lacks an iodine moiety and, thus, amiodarone's iodine‐related organ toxicity, while its methane sulfonyl group decreases lipophilicity so shortening half‐life and decreasing tissue accumulation. Electrophysiological studies show that dronedarone shares amiodarone's multichannel blocking effects, inhibiting transmembrane Na+, K+, Ca2+, and slow L‐type calcium channels, as well as its antiadrenergic effects. Unlike amiodarone, it has little effect at thyroid receptors. Possessing both rate‐ and rhythm‐control properties, dronedarone has proved safe and effective in preventing recurrence of atrial fibrillation (AF) in patients with persistent AF in the Dronedarone Atrial Fibrillation Study After Electrical Cardioversion (DAFNE) trial, the first prospective randomized trial to evaluate its efficacy and safety. Dronedarone has since undergone further extensive evaluation in three pivotal phase III trials. In two sister studies, the European Trial in Atrial Fibrillation or Flutter Patients Receiving Dronedarone for the Maintenance of Sinus Rhythm (EURIDIS) and American–Australian–African Trial with Dronedarone in Atrial Fibrillation/Flutter Patients for the Maintenance of Sinus Rhythm (ADONIS), dronedarone 400 mg b.i.d. showed significant efficacy against placebo in prevention of AF recurrence. Additionally, in patients with permanent AF, dronedarone was highly effective at controlling ventricular rate on top of standard rate‐controlling therapies in the Efficacy and Safety of Dronedarone for the Control of Ventricular Rate during Atrial Fibrillation (ERATO) study.
- 3 August 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (s2) , S17-S20
Dronedarone: An Emerging Agent with Rhythm‐ and Rate‐Controlling Effects
Of current antiarrhythmic agents, amiodarone is among the most effective with the additional advantage of having little proarrhythmic potential. However, it can cause potentially serious extracardiac side effects, stimulating the search for safer derivatives. Dronedarone, a new antiarrhythmic drug that is structurally related to amiodarone, lacks an iodine moiety and, thus, amiodarone's iodine‐related organ toxicity, while its methane sulfonyl group decreases lipophilicity so shortening half‐life and decreasing tissue accumulation. Electrophysiological studies show that dronedarone shares amiodarone's multichannel blocking effects, inhibiting transmembrane Na+, K+, Ca2+, and slow L‐type calcium channels, as well as its antiadrenergic effects. Unlike amiodarone, it has little effect at thyroid receptors. Possessing both rate‐ and rhythm‐control properties, dronedarone has proved safe and effective in preventing recurrence of atrial fibrillation (AF) in patients with persistent AF in the Dronedarone Atrial Fibrillation Study After Electrical Cardioversion (DAFNE) trial, the first prospective randomized trial to evaluate its efficacy and safety. Dronedarone has since undergone further extensive evaluation in three pivotal phase III trials. In two sister studies, the European Trial in Atrial Fibrillation or Flutter Patients Receiving Dronedarone for the Maintenance of Sinus Rhythm (EURIDIS) and American–Australian–African Trial with Dronedarone in Atrial Fibrillation/Flutter Patients for the Maintenance of Sinus Rhythm (ADONIS), dronedarone 400 mg b.i.d. showed significant efficacy against placebo in prevention of AF recurrence. Additionally, in patients with permanent AF, dronedarone was highly effective at controlling ventricular rate on top of standard rate‐controlling therapies in the Efficacy and Safety of Dronedarone for the Control of Ventricular Rate during Atrial Fibrillation (ERATO) study.
- 13 June 2006
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 29 (6) , 582-588
Incidence of Atrial Tachyarrhythmias in Pacemaker Patients: Results from the Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated Patients (BEATS) Study
Objectives: The prospective Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated patients (BEATS) study compared atrial tachyarrhythmia (AT) detection by means of serial ECG recordings versus device detection. Background: The annual incidence of AT in patients with dual‐chamber pacemakers may be significantly underestimated based on ECG and Holter recordings. Methods: A DDD(R) device capable of AT‐triggered dual‐channel electrogram (EGM) storage was implanted in 254 patients (70 ± 11 years, 159 men) with a class I pacing indication. Patients were seen at 6, 26, and 52 weeks after pacemaker implantation. At all visits, symptoms were checked, surface ECGs were recorded including a 24‐hour Holter recording at 6 weeks, and the pacemakers were interrogated. Primary study endpoint was AT documentation by surface ECG/Holter versus stored EGMs. Secondary endpoints consisted of the association between patients' symptoms and AT documentation, and of the AT incidence depending on pacing indication and a history of AT. Results: ATs were documented by ECG/Holter recordings in 37 patients (15%) and by stored EGMs in 137 patients (54%) (P < 0.0001). Symptoms were absent in 108 of 137 patients (79%) with device‐documented AT but present in 70 of 117 patients (60%) without AT documentation. AT documentation was more frequent in patients with a history of AT but not in patients with sinus node compared to AV node disease. Conclusion: ATs occur in pacemaker patients significantly more frequently than estimated by ECG/Holter recordings. Only the analysis of device‐stored EGMs allows reliable assessment of the AT burden.
- 13 June 2006
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 29 (6) , 582-588
Incidence of Atrial Tachyarrhythmias in Pacemaker Patients: Results from the Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated Patients (BEATS) Study
Objectives: The prospective Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated patients (BEATS) study compared atrial tachyarrhythmia (AT) detection by means of serial ECG recordings versus device detection. Background: The annual incidence of AT in patients with dual‐chamber pacemakers may be significantly underestimated based on ECG and Holter recordings. Methods: A DDD(R) device capable of AT‐triggered dual‐channel electrogram (EGM) storage was implanted in 254 patients (70 ± 11 years, 159 men) with a class I pacing indication. Patients were seen at 6, 26, and 52 weeks after pacemaker implantation. At all visits, symptoms were checked, surface ECGs were recorded including a 24‐hour Holter recording at 6 weeks, and the pacemakers were interrogated. Primary study endpoint was AT documentation by surface ECG/Holter versus stored EGMs. Secondary endpoints consisted of the association between patients' symptoms and AT documentation, and of the AT incidence depending on pacing indication and a history of AT. Results: ATs were documented by ECG/Holter recordings in 37 patients (15%) and by stored EGMs in 137 patients (54%) (P < 0.0001). Symptoms were absent in 108 of 137 patients (79%) with device‐documented AT but present in 70 of 117 patients (60%) without AT documentation. AT documentation was more frequent in patients with a history of AT but not in patients with sinus node compared to AV node disease. Conclusion: ATs occur in pacemaker patients significantly more frequently than estimated by ECG/Holter recordings. Only the analysis of device‐stored EGMs allows reliable assessment of the AT burden.
- 12 December 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (12) , 1317-1319
Beat-to-Beat Cycle Length Variation During Narrow QRS Complex Tachycardia: What Is the Mechanism?
- 12 December 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (12) , 1317-1319
Beat-to-Beat Cycle Length Variation During Narrow QRS Complex Tachycardia: What Is the Mechanism?
- 12 April 2005
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (6) , 620-624
Quantitative Assessment of Microvolt T‐Wave Alternans in Patients with Congestive Heart Failure
Introduction: T‐wave alternans has been shown to be linked to the genesis of ventricular tachyarrhythmias. Currently, only qualitative assessment of microvolt T‐wave alternans (MTWA) is recommended in clinical practise. Whether quantitave assessment of MTWA yields complementary information is unknown. Methods and Results: Noninvasive MTWA determination was performed in 204 consecutive patients with ischemic or nonischemic cardiomyopathy. Of those, 100 tested MTWA positive. In these recordings, MTWA magnitude was quantitatively assessed (alternans voltage, Valt). Patients were followed for a mean of 17 months. Ventricular tachyarrhythmic events constituted the study endpoint. Patients with nonischemic cardiomyopathy had a higher Valt than patients with ischemic cardiomyopathy (10.3 ± 9.2 [median 7.2] vs 6.2 ± 3.2 [median 4.6]μV; P = 0.007). The number of MTWA‐positive ECG leads was also higher in patients nonischemic cardiomyopathy (7.3 ± 2.4 [median 8] vs 6.0 ± 2.5 [median 6]; P = 0.016). Patients who suffered an arrhythmic event during follow‐up had higher MTWA voltages (10.8 ± 10.0 [median 8.8] vs 7.4 ± 5.7 [median 6.4]μV; P = 0.05) a higher number of MTWA‐positive ECG leads (7.6 ± 2.4 [median 8] vs 6.4 ± 2.5 [median 6]; P = 0.05) compared to patients with an uncomplicated course. Conclusion: Patients with nonischemic cardiomyopathy and patients with tachyarrhythmic complications have more extensive MTWA possibly reflecting more extensive myocardial damage and a higher arrhythmia propensity.
- 12 April 2005
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (6) , 620-624
Quantitative Assessment of Microvolt T‐Wave Alternans in Patients with Congestive Heart Failure
Introduction: T‐wave alternans has been shown to be linked to the genesis of ventricular tachyarrhythmias. Currently, only qualitative assessment of microvolt T‐wave alternans (MTWA) is recommended in clinical practise. Whether quantitave assessment of MTWA yields complementary information is unknown. Methods and Results: Noninvasive MTWA determination was performed in 204 consecutive patients with ischemic or nonischemic cardiomyopathy. Of those, 100 tested MTWA positive. In these recordings, MTWA magnitude was quantitatively assessed (alternans voltage, Valt). Patients were followed for a mean of 17 months. Ventricular tachyarrhythmic events constituted the study endpoint. Patients with nonischemic cardiomyopathy had a higher Valt than patients with ischemic cardiomyopathy (10.3 ± 9.2 [median 7.2] vs 6.2 ± 3.2 [median 4.6]μV; P = 0.007). The number of MTWA‐positive ECG leads was also higher in patients nonischemic cardiomyopathy (7.3 ± 2.4 [median 8] vs 6.0 ± 2.5 [median 6]; P = 0.016). Patients who suffered an arrhythmic event during follow‐up had higher MTWA voltages (10.8 ± 10.0 [median 8.8] vs 7.4 ± 5.7 [median 6.4]μV; P = 0.05) a higher number of MTWA‐positive ECG leads (7.6 ± 2.4 [median 8] vs 6.4 ± 2.5 [median 6]; P = 0.05) compared to patients with an uncomplicated course. Conclusion: Patients with nonischemic cardiomyopathy and patients with tachyarrhythmic complications have more extensive MTWA possibly reflecting more extensive myocardial damage and a higher arrhythmia propensity.
- 26 January 2004
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 15 (1) , 90-93
Catheter Ablation of Frequently Recurring Ventricular Fibrillation in a Patient after Aortic Valve Repair
It has been demonstrated that idiopathic ventricular fibrillation (VF) can be triggered by ventricular premature beats (VPBs) arising from the Purkinje fibers. Eliminating these VPBs by radiofrequency catheter ablation prevented VF recurrences. Whether the same pathophysiology and the same treatment option exist in patients with structural heart disease is unknown. Recurrent VF was observed in a 17-year-old patient after aortic valve repair of a perforated noncoronary cusp with resulting severe aortic regurgitation. VF recurred despite therapy with various antiarrhythmic drugs. A maximum of 14 external defibrillations was necessary during a 24-hour period to stabilize the patient. Due to increasing hemodynamic instability as a result of this electrical storm, the patient was referred for invasive diagnostics. During electrophysiologic study, frequent short runs of VF initiated by VPB with a narrow QRS complex were observed. After extensive mapping of the right and left ventricles, two distinct sources of VPBs originating from anteroseptal and inferoseptal areas of the left ventricle could be successfully ablated. VPBs were preceded by distinct Purkinje potentials with intervals from the Purkinje potential to QRS onset of VPB of 68 ms and 30 ms at effective sites, respectively. During short-term follow-up of 2 months, there was no VF recurrence. VPB originating from the Purkinje system may be one possibility for VF initiation in patients with structural heart disease. Eliminating these sources of VPBs by catheter ablation can prevent recurrent VF in such patients.
- 26 January 2004
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 15 (1) , 90-93
Catheter Ablation of Frequently Recurring Ventricular Fibrillation in a Patient after Aortic Valve Repair
It has been demonstrated that idiopathic ventricular fibrillation (VF) can be triggered by ventricular premature beats (VPBs) arising from the Purkinje fibers. Eliminating these VPBs by radiofrequency catheter ablation prevented VF recurrences. Whether the same pathophysiology and the same treatment option exist in patients with structural heart disease is unknown. Recurrent VF was observed in a 17-year-old patient after aortic valve repair of a perforated noncoronary cusp with resulting severe aortic regurgitation. VF recurred despite therapy with various antiarrhythmic drugs. A maximum of 14 external defibrillations was necessary during a 24-hour period to stabilize the patient. Due to increasing hemodynamic instability as a result of this electrical storm, the patient was referred for invasive diagnostics. During electrophysiologic study, frequent short runs of VF initiated by VPB with a narrow QRS complex were observed. After extensive mapping of the right and left ventricles, two distinct sources of VPBs originating from anteroseptal and inferoseptal areas of the left ventricle could be successfully ablated. VPBs were preceded by distinct Purkinje potentials with intervals from the Purkinje potential to QRS onset of VPB of 68 ms and 30 ms at effective sites, respectively. During short-term follow-up of 2 months, there was no VF recurrence. VPB originating from the Purkinje system may be one possibility for VF initiation in patients with structural heart disease. Eliminating these sources of VPBs by catheter ablation can prevent recurrent VF in such patients.