Ganeshram Krishnamoorthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ganeshram Krishnamoorthy has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Albert van Den Berg
BIOS Lab-On-A-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
3 shared publicationsEdwin T. Carlen
BIOS Lab-On-A-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
3 shared publicationsRichard B. M. Schasfoort
BIOS Lab-on-a-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, Enschede, the Netherlands
3 shared publicationsJ. Bianca Beusink
BIOS Lab-on-a-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, Enschede, the Netherlands
2 shared publicationsDaniël Wijnperlé
BIOS Lab-on-a-chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217,Enschede,The Netherlands
1 shared publicationHans L. Deboer
BIOS Lab-on-a-chip Group, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217,Enschede,The Netherlands
1 shared publication
Latest Publications
- 1 July 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 148 (2) , 511-521
Surface plasmon resonance imaging based multiplex biosensor: Integration of biomolecular screening, detection and kinetics estimation
- 1 July 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 148 (2) , 511-521
Surface plasmon resonance imaging based multiplex biosensor: Integration of biomolecular screening, detection and kinetics estimation
- 28 May 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (8) , 1020-1025
High-throughput surface plasmon resonance imaging-based biomolecular kinetic screening analysis
In this paper we show a high-throughput method to screen the kinetics and affinity constants of many biomolecular interactions simultaneously. During the preparation of the sensor chip, ligands were serially diluted and spotted in a 6 × 4 microarray on the sensor surface. A multi-analyte sample was injected and the real-time surface plasmon resonance (SPR) responses of all the 24 microarray spots were obtained using a commercial SPR imaging instrument. The multi responses of the association and dissociation processes obtained from a single analyte injection are sufficient to calculate the rates and affinity constants of the interactions between three interactant antigen-antibody pairs using a simple monophasic kinetic model. The method drastically reduces the measurement time and cost in the benefit of increased throughput.
- 28 May 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (8) , 1020-1025
High-throughput surface plasmon resonance imaging-based biomolecular kinetic screening analysis
In this paper we show a high-throughput method to screen the kinetics and affinity constants of many biomolecular interactions simultaneously. During the preparation of the sensor chip, ligands were serially diluted and spotted in a 6 × 4 microarray on the sensor surface. A multi-analyte sample was injected and the real-time surface plasmon resonance (SPR) responses of all the 24 microarray spots were obtained using a commercial SPR imaging instrument. The multi responses of the association and dissociation processes obtained from a single analyte injection are sufficient to calculate the rates and affinity constants of the interactions between three interactant antigen-antibody pairs using a simple monophasic kinetic model. The method drastically reduces the measurement time and cost in the benefit of increased throughput.
- 1 January 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (8) , 986-990
Electrokinetic label-free screening chip: a marriage of multiplexing and high throughput analysis using surface plasmon resonance imaging
We present an electrokinetic label-free biomolecular screening chip (Glass/PDMS) to screen up to 10 samples simultaneously using surface plasmon resonance imaging (iSPR). This approach reduces the duration of an experiment when compared to conventional experimental methods. This new device offers a high degree of parallelization not only for analyte samples, but also for multiplex analyte interactions where up to 90 ligands are immobilized on the sensing surface. The proof of concept has been demonstrated with well-known biomolecular interactant pairs. The new chip can be used for high throughput screening applications and kinetics parameter extraction, simultaneously, of interactant–protein complex formation.
- 1 January 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (8) , 986-990
Electrokinetic label-free screening chip: a marriage of multiplexing and high throughput analysis using surface plasmon resonance imaging
We present an electrokinetic label-free biomolecular screening chip (Glass/PDMS) to screen up to 10 samples simultaneously using surface plasmon resonance imaging (iSPR). This approach reduces the duration of an experiment when compared to conventional experimental methods. This new device offers a high degree of parallelization not only for analyte samples, but also for multiplex analyte interactions where up to 90 ligands are immobilized on the sensing surface. The proof of concept has been demonstrated with well-known biomolecular interactant pairs. The new chip can be used for high throughput screening applications and kinetics parameter extraction, simultaneously, of interactant–protein complex formation.
- 19 October 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 1 (3) , 162-169
Single injection microarray-based biosensor kinetics
Binding affinity of biomolecular interactions can be directly extracted from measured surface plasmon resonance biosensor sensorgrams by fitting the data to the appropriate model equations. The conventional method for affinity estimation uses a series of analytes and buffers that are injected serially to a single immobilized ligand on the sensing surface, including a regeneration step between each injection, to generate information about the binding behavior. We present an alternative method to estimate the affinity using a single analyte concentration injected to multiple ligand densities in a microarray format. This parameter estimation method eliminates the need for multiple analyte injections and surface regeneration steps, which can be important for applications where there is limited analyte serum, fragile ligand-surface attachment, or the detection of multiple biomolecule interactions. The single analyte injection approach for binding affinity estimation has been demonstrated for two different interactant pairs, β2 microglobulin/anti-β2 microglobulin (β2M) and human IgG/Fab fragments of anti-human IgG (hIgG), where the ligands are printed in a microarray format. Quantitative comparisons between the estimated binding affinities measured with the conventional method are β2M: KD = 1.48 ± 0.28 nM and hIgG: KD = 12.6 ± 0.2 nM and for the single injection method are β2M: KD = 1.52 ± 0.22 nM and hIgG: KD = 12.5 ± 0.6 nM, which are in good agreement in both cases.
- 19 October 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 1 (3) , 162-169
Single injection microarray-based biosensor kinetics
Binding affinity of biomolecular interactions can be directly extracted from measured surface plasmon resonance biosensor sensorgrams by fitting the data to the appropriate model equations. The conventional method for affinity estimation uses a series of analytes and buffers that are injected serially to a single immobilized ligand on the sensing surface, including a regeneration step between each injection, to generate information about the binding behavior. We present an alternative method to estimate the affinity using a single analyte concentration injected to multiple ligand densities in a microarray format. This parameter estimation method eliminates the need for multiple analyte injections and surface regeneration steps, which can be important for applications where there is limited analyte serum, fragile ligand-surface attachment, or the detection of multiple biomolecule interactions. The single analyte injection approach for binding affinity estimation has been demonstrated for two different interactant pairs, β2 microglobulin/anti-β2 microglobulin (β2M) and human IgG/Fab fragments of anti-human IgG (hIgG), where the ligands are printed in a microarray format. Quantitative comparisons between the estimated binding affinities measured with the conventional method are β2M: KD = 1.48 ± 0.28 nM and hIgG: KD = 12.6 ± 0.2 nM and for the single injection method are β2M: KD = 1.52 ± 0.22 nM and hIgG: KD = 12.5 ± 0.6 nM, which are in good agreement in both cases.