Livia Nagy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Livia Nagy has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Géza Nagy
Department for General and Physical Chemistry, University of Pécs, Ifjúság u. 6. H-7601, Hungary
3 shared publications- Géza Nagy
Department of Physical Chemistry , University of La Laguna , La Laguna, Tenerife, Spain
2 shared publications - András Kiss
Department of Physical Chemistry and Materials Science, Faculty of Sciences, University of Pécs, Ifjúság útja 6, H-7624 Pécs, Hungary
1 shared publication - Anton Alexandru Ciucu
Department of Analytical Chemistry and Physical Chemistry, University of Bucharest, 90–92 Panduri Av., District 5, 050663 Bucharest, Romania
1 shared publication - Bibiana María Fernández-Pérez
Physics and Astronomy Department, University of Padova, Via Marzolo 8, Padova I-35131, Italy
1 shared publication - Constantin Mihailciuc
University of Bucharest
1 shared publication
Latest Publications
- Open Access
Contributions of Microelectrochemical Scanning Techniques for the Efficient Detection of Localized Corrosion Processes at the Cut Edges of Polymer-Coated Galvanized Steel
Spatially resolved information on corrosion reactions operating at the cut edges of coated metals can be obtained using microelectrochemical scanning techniques using a suitable selection of operation modes and scanning probes. The scanning vibrating electrode technique (SVET) provides current density maps with a spatial resolution of the order of the dimensions of the sample, which allows the temporal evolution of the corrosion reactions to be followed over time. This leads to the identification and localization of cathodic and anodic sites, although the technique lacks chemical specificity for the unequivocal identification of the reactive species. The application of scanning electrochemical microscopy (SECM) was previously limited to image cathodic reaction sites, either due to oxygen consumption in the amperometric operation or by the alkalinisation of the electrolyte in potentiometric operation. However, it is shown that anodic sites can be effectively monitored using an ion-selective microelectrode (ISME) as a probe. The ISME probes detected differences in the local concentrations of Zn2+ and OH− ions from the cut edges of a complete coil coating system compared to the same system after the polymeric layers were removed. In this way, it has been shown that the inhibitor loading in the polymer layers effectively contributes to reducing the corrosion rates at the cut edge, thus helping to extend the useful life of the sacrificial galvanized layer bonded directly to the steel matrix. Additionally, these two probe configurations can be integrated into a multi-electrode tip for potentiometric operation to simultaneously monitor localized changes in pH values and metal ion dissolution in a single scan. Spatial and temporal distributions were further investigated using different rastering procedures, and the potential of constructing pseudomaps for 2D-imaging is described.
Open AccessContributions of Microelectrochemical Scanning Techniques for the Efficient Detection of Localized Corrosion Processes at the Cut Edges of Polymer-Coated Galvanized Steel
Spatially resolved information on corrosion reactions operating at the cut edges of coated metals can be obtained using microelectrochemical scanning techniques using a suitable selection of operation modes and scanning probes. The scanning vibrating electrode technique (SVET) provides current density maps with a spatial resolution of the order of the dimensions of the sample, which allows the temporal evolution of the corrosion reactions to be followed over time. This leads to the identification and localization of cathodic and anodic sites, although the technique lacks chemical specificity for the unequivocal identification of the reactive species. The application of scanning electrochemical microscopy (SECM) was previously limited to image cathodic reaction sites, either due to oxygen consumption in the amperometric operation or by the alkalinisation of the electrolyte in potentiometric operation. However, it is shown that anodic sites can be effectively monitored using an ion-selective microelectrode (ISME) as a probe. The ISME probes detected differences in the local concentrations of Zn2+ and OH− ions from the cut edges of a complete coil coating system compared to the same system after the polymeric layers were removed. In this way, it has been shown that the inhibitor loading in the polymer layers effectively contributes to reducing the corrosion rates at the cut edge, thus helping to extend the useful life of the sacrificial galvanized layer bonded directly to the steel matrix. Additionally, these two probe configurations can be integrated into a multi-electrode tip for potentiometric operation to simultaneously monitor localized changes in pH values and metal ion dissolution in a single scan. Spatial and temporal distributions were further investigated using different rastering procedures, and the potential of constructing pseudomaps for 2D-imaging is described.
- 18 September 2019
- Published by Wiley in European Journal of Inorganic Chemistry
- Vol. 2019 (38) , 4095-4104
Molecular Recognition of Strong Acids by Using a 2‐Ureido‐4‐Ferrocenyl Pyrimidine Receptor
The properties of a ferrocenyl ureidopyrimidine derivative, a potential electrochemical sensor for trifluoromethanesulfonic acid and trifluoroacetic acid, were investigated using UV/Vis, NMR, and CV measurements. Upon protonation, a structural change was found to take place leading to the formation of a proper binding site for the anion of the acid. Anion binding has been proved for both CF3SO3– and CF3CO2–as well as for the BF4– anion by 1H NMR measurements. Moreover, titration experiments carried out with CF3SO3H and CF3CO2H resulted in different responses in the NMR spectra of the pyrimidine host. Cyclic voltammetry was found to be suitable to follow the addition of the acids to the host molecule. DFT calculations and X‐ray diffraction were used to explore the properties of anion binding.
- 18 September 2019
- Published by Wiley in European Journal of Inorganic Chemistry
- Vol. 2019 (38) , 4095-4104
Molecular Recognition of Strong Acids by Using a 2‐Ureido‐4‐Ferrocenyl Pyrimidine Receptor
The properties of a ferrocenyl ureidopyrimidine derivative, a potential electrochemical sensor for trifluoromethanesulfonic acid and trifluoroacetic acid, were investigated using UV/Vis, NMR, and CV measurements. Upon protonation, a structural change was found to take place leading to the formation of a proper binding site for the anion of the acid. Anion binding has been proved for both CF3SO3– and CF3CO2–as well as for the BF4– anion by 1H NMR measurements. Moreover, titration experiments carried out with CF3SO3H and CF3CO2H resulted in different responses in the NMR spectra of the pyrimidine host. Cyclic voltammetry was found to be suitable to follow the addition of the acids to the host molecule. DFT calculations and X‐ray diffraction were used to explore the properties of anion binding.
- 1 January 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 190, 149-156
Sensitivity enhancement of a “bananatrode” biosensor for dopamine based on SECM studies inside its reaction layer
- 1 January 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 190, 149-156
Sensitivity enhancement of a “bananatrode” biosensor for dopamine based on SECM studies inside its reaction layer
- 4 May 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (7-8) , 1411-1426
Application of Copper Electrode Based Amperometric Detector Cell for LC Analysis of Main Sugar Component of Honey and Nectar
A method for quantification of the main sugar components of honey and nectars are worked out and investigated. The method employs IC separation on CarboPac PA1 column with sodium hydroxide eluent and home made, electrochemical detector cells that contain copper working electrode. The detector cells operate in amperometric mode. The electrochemical oxidation of the sugar components was studied, estimating the number of electrons exchanged, the rate constant of the electrode reaction. The electrode processes showed electrocatalytic character with formate ions as main product of oxidation. Real samples of honey and nectar taken from different plants were analyzed with the method proposed.
- 4 May 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (7-8) , 1411-1426
Application of Copper Electrode Based Amperometric Detector Cell for LC Analysis of Main Sugar Component of Honey and Nectar
A method for quantification of the main sugar components of honey and nectars are worked out and investigated. The method employs IC separation on CarboPac PA1 column with sodium hydroxide eluent and home made, electrochemical detector cells that contain copper working electrode. The detector cells operate in amperometric mode. The electrochemical oxidation of the sugar components was studied, estimating the number of electrons exchanged, the rate constant of the electrode reaction. The electrode processes showed electrocatalytic character with formate ions as main product of oxidation. Real samples of honey and nectar taken from different plants were analyzed with the method proposed.
- 1 November 2006
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 69 (1-2) , 121-132
Electrochemical behavior of ferrocene in ionic liquid media
- 1 November 2006
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 69 (1-2) , 121-132
Electrochemical behavior of ferrocene in ionic liquid media
- 1 November 2006
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 69 (1-2) , 133-141
Periodically interrupted amperometry. A way of improving analytical performance of membrane coated electrodes
- 1 November 2006
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 69 (1-2) , 133-141
Periodically interrupted amperometry. A way of improving analytical performance of membrane coated electrodes
- 1 June 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 76 (1-3) , 494-499
Copper electrode based amperometric detector cell for sugar and organic acid measurements
- 1 June 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 76 (1-3) , 494-499
Copper electrode based amperometric detector cell for sugar and organic acid measurements