Thomas Stephen Kickler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thomas Stephen Kickler has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Jayesh Jani
Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
3 shared publicationsClifford M. Takemoto
Department of Pediatrics, Johns Hopkins University School of Medicine, Baltimore, MD, USA
2 shared publicationsMichael B. Streiff
Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA
2 shared publicationsDanielle Judge
Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
1 shared publicationElise Gelwan
Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
1 shared publication- Gang Zheng
Division of Laboratory Genetics and Genomics, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota
1 shared publication
Latest Publications
- 4 August 2017
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 24 (5) , 749-754
The Clinical Utility of the Heparin Neutralization Assay in the Diagnosis of Heparin-Induced Thrombocytopenia
Heparin-induced thrombocytopenia (HIT) remains diagnostically challenging. Immunoassays including PF4/heparin enzyme-linked immunosorbent assay (ELISA) have high sensitivity but low specificity. Whether the heparin neutralization assay (HNA) improves the diagnostic accuracy of the PF4/heparin ELISA for HIT is uncertain. In this study, to assess its clinical utility and evaluate whether it improves the diagnostic accuracy for HIT, we implemented HNA in conjunction with PF4/heparin ELISA over a 1-year period. A total of 1194 patient samples were submitted to the laboratory for testing from December 2015 to November 2016. Heparin neutralization assay alone is a poor predictor for HIT, but it has high negative predictive value (NPV): Cases with %inhibition <70% are always negative for serotonin release assay. It improves the diagnostic positive predictive value (PPV) of ELISA without compromising sensitivity: ELISA optical density (OD) ≥1.4 alone has a sensitivity of 88% (14/16) and a PPV of 61% (14/23); with HNA %inhibition ≥70%, the sensitivity remains 88% (14/16) and PPV is 82% (14/17). 4Ts score correlates with ELISA OD and predicts HIT; the predictive accuracy of 4Ts score is further improved by HNA. Interestingly, HNA %inhibition of <70% correlates with low 4Ts scores. Based on its high NPV, HNA has the potential to facilitate more timely and accurate HIT diagnosis.
- 4 August 2017
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 24 (5) , 749-754
The Clinical Utility of the Heparin Neutralization Assay in the Diagnosis of Heparin-Induced Thrombocytopenia
Heparin-induced thrombocytopenia (HIT) remains diagnostically challenging. Immunoassays including PF4/heparin enzyme-linked immunosorbent assay (ELISA) have high sensitivity but low specificity. Whether the heparin neutralization assay (HNA) improves the diagnostic accuracy of the PF4/heparin ELISA for HIT is uncertain. In this study, to assess its clinical utility and evaluate whether it improves the diagnostic accuracy for HIT, we implemented HNA in conjunction with PF4/heparin ELISA over a 1-year period. A total of 1194 patient samples were submitted to the laboratory for testing from December 2015 to November 2016. Heparin neutralization assay alone is a poor predictor for HIT, but it has high negative predictive value (NPV): Cases with %inhibition <70% are always negative for serotonin release assay. It improves the diagnostic positive predictive value (PPV) of ELISA without compromising sensitivity: ELISA optical density (OD) ≥1.4 alone has a sensitivity of 88% (14/16) and a PPV of 61% (14/23); with HNA %inhibition ≥70%, the sensitivity remains 88% (14/16) and PPV is 82% (14/17). 4Ts score correlates with ELISA OD and predicts HIT; the predictive accuracy of 4Ts score is further improved by HNA. Interestingly, HNA %inhibition of <70% correlates with low 4Ts scores. Based on its high NPV, HNA has the potential to facilitate more timely and accurate HIT diagnosis.
- Open Access
- 1 April 2013
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 139 (4) , 450-456
Activated Partial Thromboplastin Time and Anti-Xa Measurements in Heparin Monitoring
We examined the concordance of heparin levels measured by a chromogenic anti-Xa assay and the activated partial thromboplastin time (APTT) during unf
- 1 April 2013
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 139 (4) , 450-456
Open AccessActivated Partial Thromboplastin Time and Anti-Xa Measurements in Heparin Monitoring
We examined the concordance of heparin levels measured by a chromogenic anti-Xa assay and the activated partial thromboplastin time (APTT) during unf
- 1 November 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 161 (2) , 83-87
HIV infection and cocaine use induce endothelial damage and dysfunction in African Americans
- 1 November 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 161 (2) , 83-87
HIV infection and cocaine use induce endothelial damage and dysfunction in African Americans
- 3 June 2009
- Published by American Medical Association (AMA) in JAMA
- Vol. 301 (21) , 2267-2269
Dr William W. Duke: Pioneer in Platelet Research
Opinion from JAMA — Dr William W. Duke — Pioneer in Platelet Research
- 3 June 2009
- Published by American Medical Association (AMA) in JAMA
- Vol. 301 (21) , 2267-2269
Dr William W. Duke: Pioneer in Platelet Research
Opinion from JAMA — Dr William W. Duke — Pioneer in Platelet Research
- 1 June 2006
- Published by Wiley in Transfusion Alternatives in Transfusion Medicine
- Vol. 8 (2) , 79-85
Platelet biology – an overview
SUMMARY: Understanding the biology of platelet is important for one to treat patients with acquired or inherited platelet disorders. Platelets provide primary hemostasis by performing five primary functions: adhesion, aggregation, secretion, and providing procoagulant surface and clot retraction. The elucidation of the molecular mechanisms carrying out these functions has led to a better understanding of the pathophysiology of bleeding and the development of new approaches in treating patients with qualitative and quantitative platelet disorders. The purpose of this review is to provide a foundation for understanding the other papers in this publication on the treatment of platelet disorders.
- 1 June 2006
- Published by Wiley in Transfusion Alternatives in Transfusion Medicine
- Vol. 8 (2) , 79-85
Platelet biology – an overview
SUMMARY: Understanding the biology of platelet is important for one to treat patients with acquired or inherited platelet disorders. Platelets provide primary hemostasis by performing five primary functions: adhesion, aggregation, secretion, and providing procoagulant surface and clot retraction. The elucidation of the molecular mechanisms carrying out these functions has led to a better understanding of the pathophysiology of bleeding and the development of new approaches in treating patients with qualitative and quantitative platelet disorders. The purpose of this review is to provide a foundation for understanding the other papers in this publication on the treatment of platelet disorders.
- Open Access
- 1 June 2006
- Published by Wiley in Transfusion Alternatives in Transfusion Medicine
- Vol. 8 (2) , 127-134
Alternatives to platelet transfusions in the management of platelet dysfunction or thrombocytopenia
- 1 June 2006
- Published by Wiley in Transfusion Alternatives in Transfusion Medicine
- Vol. 8 (2) , 127-134
Open AccessAlternatives to platelet transfusions in the management of platelet dysfunction or thrombocytopenia
- 1 February 2006
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 125 (2) , 282-287
A Clinical Evaluation of High Fluorescent Platelet Fraction Percentage in Thrombocytopenia
We evaluated an automated method (XE-2100 automated blood cell counter equipped with a laser and upgraded software, Sysmex, Kobe, Japan) to quantify the high fluorescent platelet fraction percentage (HFPF%) as an indicator of platelet production. The mean HFPF% value was 3.1 in 80 healthy subjects (95% confidence interval, 2.8%–3.5%). The coefficient of variation was less than 10% for elevated values and 10% to 20% for normal values. Sample stability was up to 48 hours. We tested the HFPF% in 171 patients with thrombocytopenia. The highest values were found in patients with autoimmune thrombocytopenia and disseminated intravascular coagulation, although HFPF% also was increased in patients with regenerating marrows. In other patient groups with decreased platelet production, the HFPF% was within the normal range. The HFPF% was predictive in the evaluation of thrombocytopenia. We found elevated HFPF% values in disorders associated with increased platelet production, particularly associated with platelet destruction, and normal values in disorders associated with decreased platelet production. The results are precise: testing can be performed as readily as a CBC count using an EDTA-anticoagulated blood sample.
- 1 February 2006
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 125 (2) , 282-287
A Clinical Evaluation of High Fluorescent Platelet Fraction Percentage in Thrombocytopenia
We evaluated an automated method (XE-2100 automated blood cell counter equipped with a laser and upgraded software, Sysmex, Kobe, Japan) to quantify the high fluorescent platelet fraction percentage (HFPF%) as an indicator of platelet production. The mean HFPF% value was 3.1 in 80 healthy subjects (95% confidence interval, 2.8%–3.5%). The coefficient of variation was less than 10% for elevated values and 10% to 20% for normal values. Sample stability was up to 48 hours. We tested the HFPF% in 171 patients with thrombocytopenia. The highest values were found in patients with autoimmune thrombocytopenia and disseminated intravascular coagulation, although HFPF% also was increased in patients with regenerating marrows. In other patient groups with decreased platelet production, the HFPF% was within the normal range. The HFPF% was predictive in the evaluation of thrombocytopenia. We found elevated HFPF% values in disorders associated with increased platelet production, particularly associated with platelet destruction, and normal values in disorders associated with decreased platelet production. The results are precise: testing can be performed as readily as a CBC count using an EDTA-anticoagulated blood sample.
- 29 July 2005
- Published by Wiley in Transfusion
- Vol. 45 (s2) , 64S-66S
From an early National Blood Foundation award to our ongoing studies in fetal and neonatal alloimmune thrombocytopenia
- 29 July 2005
- Published by Wiley in Transfusion
- Vol. 45 (s2) , 64S-66S
From an early National Blood Foundation award to our ongoing studies in fetal and neonatal alloimmune thrombocytopenia
- 29 June 2005
- Published by Wiley in Transfusion
- Vol. 45 (7) , 1233
Hematology: Basic Principles and Practice, 4th edition
- 29 June 2005
- Published by Wiley in Transfusion
- Vol. 45 (7) , 1233
Hematology: Basic Principles and Practice, 4th edition
- 1 December 2004
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 26 (6) , 423-427
Ret-Y a measure of reticulocyte size: a sensitive indicator of iron deficiency anemia
In this study the size of reticulocytes was measured, reticulocyte-Y (Ret-Y), to distinguish iron deficiency anemia from the anemia of chronic disease using a Sysmex XE2100 cell counter. We evaluated this parameter prospectively in 100 patients seen for the evaluation of anemia. A clinical diagnosis of iron deficiency anemia or anemia of chronic disease was made on the basis of a complete blood count, examination of the peripheral smear, and serum ferritin along with a history and physical examination. We analyzed the sensitivity and specificity of the Ret-Y in relationship to the clinical diagnosis. We also measured serum transferrin receptor levels to use as the gold standard laboratory test for iron deficiency against which we compared the Ret-Y. In 40 normal individuals with normal serum ferritin and transferrin receptor levels the mean Ret-Y was 1874 +/- 178 (1 SD). The mean Ret-Y in the anemia of chronic disease group (n=62) was 1722 +/- 162, not significantly different from normal. The mean Ret-Y value among iron-deficient patients (n=38), was 1407 +/- 136 (P <0.01 vs. the anemia of chronic disease group's Ret-Y value). Receiver operator curves showed that Ret-Y correlated closely to the serum transferrin receptor and was superior to the mean corpuscular volume, and ferritin level, in differentiating the type of anemia. The Ret-Y parameter has the highest overall sensitivity and specificity of the panel of tests routinely used in differentiating iron deficiency anemia from anemia of chronic disease.
- 1 December 2004
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 26 (6) , 423-427
Ret-Y a measure of reticulocyte size: a sensitive indicator of iron deficiency anemia
In this study the size of reticulocytes was measured, reticulocyte-Y (Ret-Y), to distinguish iron deficiency anemia from the anemia of chronic disease using a Sysmex XE2100 cell counter. We evaluated this parameter prospectively in 100 patients seen for the evaluation of anemia. A clinical diagnosis of iron deficiency anemia or anemia of chronic disease was made on the basis of a complete blood count, examination of the peripheral smear, and serum ferritin along with a history and physical examination. We analyzed the sensitivity and specificity of the Ret-Y in relationship to the clinical diagnosis. We also measured serum transferrin receptor levels to use as the gold standard laboratory test for iron deficiency against which we compared the Ret-Y. In 40 normal individuals with normal serum ferritin and transferrin receptor levels the mean Ret-Y was 1874 +/- 178 (1 SD). The mean Ret-Y in the anemia of chronic disease group (n=62) was 1722 +/- 162, not significantly different from normal. The mean Ret-Y value among iron-deficient patients (n=38), was 1407 +/- 136 (P <0.01 vs. the anemia of chronic disease group's Ret-Y value). Receiver operator curves showed that Ret-Y correlated closely to the serum transferrin receptor and was superior to the mean corpuscular volume, and ferritin level, in differentiating the type of anemia. The Ret-Y parameter has the highest overall sensitivity and specificity of the panel of tests routinely used in differentiating iron deficiency anemia from anemia of chronic disease.