David J. Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David J. Williams has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Amit Chandra
Centre for Biological Engineering, Loughborough University, Loughborough, LE11 3TU, UK.
2 shared publications Paul Hourd
Loughborough University, Centre for Biological Engineering, Holywell Park, Loughborough LE11 3TU, UK
2 shared publicationsAlison Wilson
CellData Services, 3 Burgate Court, York, YO43 4TZ, UK
1 shared publicationAnne L Plant
NIST, Material Measurement Laboratory, NIST, Gaithersburg, MD 20899, USA
1 shared publicationChris Leidel
FloDesign Sonics Inc., 380 Main St, Wilbraham, MA 01095, USA
1 shared publication- Conor J. McCann
University College London
1 shared publication
Latest Publications
- Open Access
- 12 July 2016
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 11 (5) , 483-492
Comparability: Manufacturing, Characterization and Controls, Report of a UK Regenerative Medicine Platform Pluripotent Stem Cell Platform Workshop, Trinity Hall, Cambridge, 14–15 September 2015
This paper summarizes the proceedings of a workshop held at Trinity Hall, Cambridge to discuss comparability and includes additional information and references to related information added subsequently to the workshop. Comparability is the need to demonstrate equivalence of product after a process change; a recent publication states that this ‘may be difficult for cell-based medicinal products’. Therefore a well-managed change process is required which needs access to good science and regulatory advice and developers are encouraged to seek help early. The workshop shared current thinking and best practice and allowed the definition of key research questions. The intent of this report is to summarize the key issues and the consensus reached on each of these by the expert delegates.
- 12 July 2016
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 11 (5) , 483-492
Open AccessComparability: Manufacturing, Characterization and Controls, Report of a UK Regenerative Medicine Platform Pluripotent Stem Cell Platform Workshop, Trinity Hall, Cambridge, 14–15 September 2015
This paper summarizes the proceedings of a workshop held at Trinity Hall, Cambridge to discuss comparability and includes additional information and references to related information added subsequently to the workshop. Comparability is the need to demonstrate equivalence of product after a process change; a recent publication states that this ‘may be difficult for cell-based medicinal products’. Therefore a well-managed change process is required which needs access to good science and regulatory advice and developers are encouraged to seek help early. The workshop shared current thinking and best practice and allowed the definition of key research questions. The intent of this report is to summarize the key issues and the consensus reached on each of these by the expert delegates.
- 14 October 2011
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 6 (sup6) , 67-69
Overcoming Manufacturing and Scale-Up Challenges
- 14 October 2011
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 6 (sup6) , 67-69
Overcoming Manufacturing and Scale-Up Challenges
- Open Access
- 1 January 2009
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 4 (1) , 45-54
Human cell culture process capability: a comparison of manual and automated production
Cell culture is one of the critical bioprocessing steps required to generate sufficient human‐derived cellular material for most cell‐based therapeutic applications in regenerative medicine. Automated cell expansion is fundamental to the development of scaled, robust and cost effective commercial production processes for cell‐based therapeutic products. This paper describes the first application of process capability analysis to establish and compare the short‐term process capability of manual and automated processes for the in vitro expansion of a selected anchorage‐dependent cell line. Estimates of the process capability indices (Cp, Cpk) have been used to assess the ability of both processes to consistently meet the requirements for a selected productivity output and to direct process improvement activities. Point estimates of Cp and Cpk show that the manual process has poor capability (Cp = 0.55, Cpk = 0.26) compared to the automated process (Cp = 1.32, Cpk = 0.25), resulting from excess variability. Comparison of point estimates, which shows that Cpk < Cp, indicates that the automated process mean was off‐centre and that intervention is required to adjust the location of the process mean. A process improvement strategy involving an adjustment to the automated process settings has demonstrated in principle that the process mean can be shifted closer to the centre of the specification to achieve an estimated seven‐fold improvement in process performance. In practice, the 90% confidence bound estimate of Cp (Cp = 0.90) indicates that that once the process is centred within the specification, a further reduction of process variation is required to attain an automated process with the desired minimum capability requirement. Copyright © 2009 John Wiley & Sons, Ltd.
- 1 January 2009
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 4 (1) , 45-54
Open AccessHuman cell culture process capability: a comparison of manual and automated production
Cell culture is one of the critical bioprocessing steps required to generate sufficient human‐derived cellular material for most cell‐based therapeutic applications in regenerative medicine. Automated cell expansion is fundamental to the development of scaled, robust and cost effective commercial production processes for cell‐based therapeutic products. This paper describes the first application of process capability analysis to establish and compare the short‐term process capability of manual and automated processes for the in vitro expansion of a selected anchorage‐dependent cell line. Estimates of the process capability indices (Cp, Cpk) have been used to assess the ability of both processes to consistently meet the requirements for a selected productivity output and to direct process improvement activities. Point estimates of Cp and Cpk show that the manual process has poor capability (Cp = 0.55, Cpk = 0.26) compared to the automated process (Cp = 1.32, Cpk = 0.25), resulting from excess variability. Comparison of point estimates, which shows that Cpk < Cp, indicates that the automated process mean was off‐centre and that intervention is required to adjust the location of the process mean. A process improvement strategy involving an adjustment to the automated process settings has demonstrated in principle that the process mean can be shifted closer to the centre of the specification to achieve an estimated seven‐fold improvement in process performance. In practice, the 90% confidence bound estimate of Cp (Cp = 0.90) indicates that that once the process is centred within the specification, a further reduction of process variation is required to attain an automated process with the desired minimum capability requirement. Copyright © 2009 John Wiley & Sons, Ltd.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6400-6405
Current Developments in Tissue Engineering of Nucleus Pulposus for the Treatment of Intervertebral Disc Degeneration
The main cause for back pain is considered to be the degenerative changes in the intervertebral disc (IVD). Some evidence indicates that IVD degeneration originates from the nucleus pulposus (NP). The IVD does not possess self repair capacity. Current treatment options range from pain management to invasive procedures. The science of disc cell transplantation is still in its infancy. Advancement in bioengineering based upon tissue engineering techniques may offer the possibility of repairing damaged disc, if an engineered NP with the appropriate functional properties can be generated to augment the degenerated disc. This is likely to require tri-axial stimulation of tissue engineering constructs.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6400-6405
Current Developments in Tissue Engineering of Nucleus Pulposus for the Treatment of Intervertebral Disc Degeneration
The main cause for back pain is considered to be the degenerative changes in the intervertebral disc (IVD). Some evidence indicates that IVD degeneration originates from the nucleus pulposus (NP). The IVD does not possess self repair capacity. Current treatment options range from pain management to invasive procedures. The science of disc cell transplantation is still in its infancy. Advancement in bioengineering based upon tissue engineering techniques may offer the possibility of repairing damaged disc, if an engineered NP with the appropriate functional properties can be generated to augment the degenerated disc. This is likely to require tri-axial stimulation of tissue engineering constructs.
- 11 May 2007
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 98 (5) , 939-955
Studies on aerosol delivery of plasmid DNA using a mesh nebulizer
Aerosol delivery of plasmid DNA therapeutic solutions is promising for the treatment of respiratory diseases. However, it poses challenges, most significantly the need to protect the delicate supercoiled (sc) structure of plasmid during aerosolization. Nebulizers for liquid aerosolization using meshes appear a better method for delivery than conventional jet and ultrasonic nebulizers. This paper explores their application to the delivery of plasmid DNA. A computational fluid dynamics model of the dynamics of fluid flow through the nozzle of the MicroAIR® mesh nebulizer indicated high strain rates (>105 s−1) near the nozzle exit capable of causing damage to the shear‐sensitive plasmid DNA. Knowledge of the strain rates predicted using CFD and molecule size determined using atomic force microscopy (AFM) enabled estimation of the hydrodynamic force and whether damage of shear‐sensitive therapeutics was likely. Plasmids of size 5.7 and 20 kb were aerosolized in the mesh nebulizer. The sc structure of the 5.7‐kb plasmid was successfully delivered without damage, while aerosolization of the 20‐kb plasmid led to disintegration of the pDNA sc structure as observed in AFM. Subsequent formulation of the sc 20‐kb plasmid with PEI resulted in successful aerosol delivery. The maximum hydrodynamic forces computed for the aerosolization of structures of the size of 5.7‐kb and PEI formulated 20‐kb plasmids were less than the forces reported to damage the structure of double‐stranded DNA. A combination of CFD analysis and structure analysis may be used to predict successful aerosol delivery in such a mesh nebulizer. Biotechnol. Bioeng. 2007;98: 939–955.
- 11 May 2007
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 98 (5) , 939-955
Studies on aerosol delivery of plasmid DNA using a mesh nebulizer
Aerosol delivery of plasmid DNA therapeutic solutions is promising for the treatment of respiratory diseases. However, it poses challenges, most significantly the need to protect the delicate supercoiled (sc) structure of plasmid during aerosolization. Nebulizers for liquid aerosolization using meshes appear a better method for delivery than conventional jet and ultrasonic nebulizers. This paper explores their application to the delivery of plasmid DNA. A computational fluid dynamics model of the dynamics of fluid flow through the nozzle of the MicroAIR® mesh nebulizer indicated high strain rates (>105 s−1) near the nozzle exit capable of causing damage to the shear‐sensitive plasmid DNA. Knowledge of the strain rates predicted using CFD and molecule size determined using atomic force microscopy (AFM) enabled estimation of the hydrodynamic force and whether damage of shear‐sensitive therapeutics was likely. Plasmids of size 5.7 and 20 kb were aerosolized in the mesh nebulizer. The sc structure of the 5.7‐kb plasmid was successfully delivered without damage, while aerosolization of the 20‐kb plasmid led to disintegration of the pDNA sc structure as observed in AFM. Subsequent formulation of the sc 20‐kb plasmid with PEI resulted in successful aerosol delivery. The maximum hydrodynamic forces computed for the aerosolization of structures of the size of 5.7‐kb and PEI formulated 20‐kb plasmids were less than the forces reported to damage the structure of double‐stranded DNA. A combination of CFD analysis and structure analysis may be used to predict successful aerosol delivery in such a mesh nebulizer. Biotechnol. Bioeng. 2007;98: 939–955.
- 1 January 2005
- Published by Institution of Engineering and Technology (IET) in IEE Proceedings - Nanobiotechnology
- Vol. 152 (6) , 207-10
Tissue engineering and regenerative medicine: manufacturing challenges
Tissue engineering and regenerative medicine are interdisciplinary fields that apply principles of engineering and life sciences to develop biological substitutes, typically composed of biological and synthetic components, that restore, maintain or improve tissue function. Many tissue engineering technologies are still at a laboratory or pre-commercial scale. The short review paper describes the most significant manufacturing and bio-process challenges inherent in the commercialisation and exploitation of the exciting results emerging from the biological and clinical laboratories exploring tissue engineering and regenerative medicine. A three-generation road map of the industry has been used to structure a view of these challenges and to define where the manufacturing community can contribute to the commercial success of the products from these emerging fields. The first-generation industry is characterised by its demonstrated clinical applications and products in the marketplace, the second is characterised by emerging clinical applications, and the third generation is characterised by aspirational clinical applications. The paper focuses on the cost reduction requirement of the first generation of the industry to allow more market penetration and consequent patient impact. It indicates the technological requirements, for instance the creation of three-dimensional tissue structures, and value chain issues in the second generation of the industry. The third-generation industry challenges lie in fundamental biological and clinical science. The paper sets out a road map of these generations to identify areas for research.
- 1 January 2005
- Published by Institution of Engineering and Technology (IET) in IEE Proceedings - Nanobiotechnology
- Vol. 152 (6) , 207-10
Tissue engineering and regenerative medicine: manufacturing challenges
Tissue engineering and regenerative medicine are interdisciplinary fields that apply principles of engineering and life sciences to develop biological substitutes, typically composed of biological and synthetic components, that restore, maintain or improve tissue function. Many tissue engineering technologies are still at a laboratory or pre-commercial scale. The short review paper describes the most significant manufacturing and bio-process challenges inherent in the commercialisation and exploitation of the exciting results emerging from the biological and clinical laboratories exploring tissue engineering and regenerative medicine. A three-generation road map of the industry has been used to structure a view of these challenges and to define where the manufacturing community can contribute to the commercial success of the products from these emerging fields. The first-generation industry is characterised by its demonstrated clinical applications and products in the marketplace, the second is characterised by emerging clinical applications, and the third generation is characterised by aspirational clinical applications. The paper focuses on the cost reduction requirement of the first generation of the industry to allow more market penetration and consequent patient impact. It indicates the technological requirements, for instance the creation of three-dimensional tissue structures, and value chain issues in the second generation of the industry. The third-generation industry challenges lie in fundamental biological and clinical science. The paper sets out a road map of these generations to identify areas for research.