Norman T. O'NEill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Norman T. O'NEill has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Seyed Ali Sayedain
Centre d’Applications et de Recherches en Télédétection, Université de Sherbrooke, Sherbrooke, QC, Canada
7 shared publications - Keyvan Ranjbar
Flight Research Laboratory, National Research Council Canada, Ottawa, Ontario, Canada
6 shared publications - Liviu Ivănescu
Metrology Research Centre, National Research Council Canada, Ottawa, Canada
6 shared publications - Yann Blanchard
ESCER Centre Department of Earth and Atmospheric Sciences University of Québec at Montréal Montréal QC Canada
6 shared publications Yasmin AboEl-Fetouh
Institute of Meteorology and Climate Research, Karlsruhe Institute of Technology, Karlsruhe, Germany
6 shared publicationsJ. S. Reid
3 shared publications
Latest Publications
- Open Access
- 12 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Reply on RC2
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 12 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Open AccessReply on RC2
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 12 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Reply on RC1
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 12 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Open AccessReply on RC1
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 19 August 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Comment on egusphere-2024-1057
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 19 August 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Open AccessComment on egusphere-2024-1057
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 20 July 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Reply on RC1
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 20 July 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Open AccessReply on RC1
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 14 July 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Comment on egusphere-2024-1057
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 14 July 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-22
Open AccessComment on egusphere-2024-1057
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 31 May 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Remote Sensing detectability of airborne Arctic dust
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- 31 May 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Open AccessRemote Sensing detectability of airborne Arctic dust
Remote sensing (RS) based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness-temperature differences at 11 and 12 µm (BTD11-12) has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD11-12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One, much more likely contributor would be water plumes in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD11-12 values would however only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced INP (Ice Nucleating Particle) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can be readily detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate sensitive region.
- Open Access
- 12 September 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (17) , 4115-4135
Detection and analysis of Lhù'ààn Mân' (Kluane Lake) dust plumes using passive and active ground-based remote sensing supported by physical surface measurements
There is growing recognition that high-latitude dust (HLD), originating from local drainage-basin flows, is the dominant source for certain important phenomena such as particle deposition on snow/ice. The analysis of such local plumes (including a better exploitation of remote sensing data) has been targeted as a key aerosol issue by the HLD community. The sub-Arctic Lhù'ààn Mân' (Kluane Lake) region in the Canadian Yukon is subject to regular drainage-basin, wind-induced dust plumes. This dust emission site is one of many current and potential proglacial dust sources in the Canadian north. In situ ground-based measurements are, due to constraints in accessing these types of regions, rare. Ground- and satellite-based remote sensing accordingly play an important role in helping to characterize local dust sources in the Arctic and sub-Arctic. We compared ground-based passive and active remote sensing springtime (May 2019) retrievals with microphysical surface-based measurements in the Lhù'ààn Mân' region in order to better understand the potential for ground- and satellite-based remote sensing of HLD plumes. This included correlation analyses between ground-based coarse mode (CM) aerosol optical depth (AOD) retrievals from AERONET AOD spectra, CM AODs derived from co-located Doppler lidar profiles, and OPS (optical particle sizer) surface measurements of CM particle-volume concentration (vc(0)). An automated dust classification scheme was developed to objectively identify local dust events. The classification process helped distinguish lidar-derived CM AODs which covaried with vdust(0) (during recognized dust events) and those that varied at the same columnar scale as AERONET-derived CM AOD (and thus could be remotely sensed). False positive cloud events for dust-induced, high-frequency variations in lidar-derived CM AODs in cloudless atmospheres indicated that the AERONET cloud-screening process was rejecting CM dust AODs. The persistence of a positive lidar ratio bias in comparing the CIMEL/lidar-derived value with a prescribed value obtained from OPS-derived particle sizes coupled with dust-speciation-derived refractive indices led to the suggestion that the prescribed value could be increased to optically derived values of 20 sr by the presence of optically significant dust particles at an effective radius of 11–12 µm. Bimodal CM PSDs (see Appendix B for a glossary) from full-fledged AERONET inversions (the combination of AOD spectra and almucantar radiances) also showed CM peaks at ∼ 1.3 and 5–6.6 µm radius: this, we argue, was associated with springtime Asian dust and Lhù'ààn Mân' dust, respectively. Correlations between the CIMEL-derived fine mode (FM) AOD and FM OPS-derived particle-volume concentrations suggest that remote sensing techniques can be employed to monitor FM dust (which is arguably a better indicator of the long-distance transport of HLD).
- 12 September 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (17) , 4115-4135
Open AccessDetection and analysis of Lhù'ààn Mân' (Kluane Lake) dust plumes using passive and active ground-based remote sensing supported by physical surface measurements
There is growing recognition that high-latitude dust (HLD), originating from local drainage-basin flows, is the dominant source for certain important phenomena such as particle deposition on snow/ice. The analysis of such local plumes (including a better exploitation of remote sensing data) has been targeted as a key aerosol issue by the HLD community. The sub-Arctic Lhù'ààn Mân' (Kluane Lake) region in the Canadian Yukon is subject to regular drainage-basin, wind-induced dust plumes. This dust emission site is one of many current and potential proglacial dust sources in the Canadian north. In situ ground-based measurements are, due to constraints in accessing these types of regions, rare. Ground- and satellite-based remote sensing accordingly play an important role in helping to characterize local dust sources in the Arctic and sub-Arctic. We compared ground-based passive and active remote sensing springtime (May 2019) retrievals with microphysical surface-based measurements in the Lhù'ààn Mân' region in order to better understand the potential for ground- and satellite-based remote sensing of HLD plumes. This included correlation analyses between ground-based coarse mode (CM) aerosol optical depth (AOD) retrievals from AERONET AOD spectra, CM AODs derived from co-located Doppler lidar profiles, and OPS (optical particle sizer) surface measurements of CM particle-volume concentration (vc(0)). An automated dust classification scheme was developed to objectively identify local dust events. The classification process helped distinguish lidar-derived CM AODs which covaried with vdust(0) (during recognized dust events) and those that varied at the same columnar scale as AERONET-derived CM AOD (and thus could be remotely sensed). False positive cloud events for dust-induced, high-frequency variations in lidar-derived CM AODs in cloudless atmospheres indicated that the AERONET cloud-screening process was rejecting CM dust AODs. The persistence of a positive lidar ratio bias in comparing the CIMEL/lidar-derived value with a prescribed value obtained from OPS-derived particle sizes coupled with dust-speciation-derived refractive indices led to the suggestion that the prescribed value could be increased to optically derived values of 20 sr by the presence of optically significant dust particles at an effective radius of 11–12 µm. Bimodal CM PSDs (see Appendix B for a glossary) from full-fledged AERONET inversions (the combination of AOD spectra and almucantar radiances) also showed CM peaks at ∼ 1.3 and 5–6.6 µm radius: this, we argue, was associated with springtime Asian dust and Lhù'ààn Mân' dust, respectively. Correlations between the CIMEL-derived fine mode (FM) AOD and FM OPS-derived particle-volume concentrations suggest that remote sensing techniques can be employed to monitor FM dust (which is arguably a better indicator of the long-distance transport of HLD).
- 17 February 2012
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 117 (D4)
Properties of Sarychev sulphate aerosols over the Arctic
Aerosols from the Sarychev Peak volcano entered the Arctic region less than a week after the strongest SO2eruption on June 15 and 16, 2009 and had, by the first week in July, spread out over the entire Arctic region. These predominantly stratospheric aerosols were determined to be sub‐micron in size and inferred to be composed of sulphates produced from the condensation of SO2gases emitted during the eruption. Average (500 nm) Sarychev‐induced stratospheric optical depths (SOD) over the Polar Environmental Atmospheric Research Laboratory (PEARL) at Eureka (Nunavut, Canada) were found to be between 0.03 and 0.05 during the months of July and August, 2009. This estimate, derived from sunphotometry and integrated lidar backscatter profiles was consistent with averages derived from lidar estimates over Ny‐Ålesund (Spitsbergen). The Sarychev SOD e‐folding time at Eureka, deduced from lidar profiles, was found to be approximately 4 months relative to a regression start date of July 27. These profiles initially revealed the presence of multiple Sarychev plumes between the tropopause and about 17 km altitude. After about two months, the complex vertical plume structures had collapsed into fewer, more homogeneous plumes located near the tropopause. It was found that the noisy character of daytime backscatter returns induced an artifactual minimum in the temporal, pan‐Arctic, CALIOP SOD response to Sarychev sulphates. A depolarization ratio discrimination criterion was used to separate the CALIOP stratospheric layer class into a low depolarization subclass which was more representative of Sarychev sulphates. Post‐SAT (post Sarychev Arrival Time) retrievals of the fine mode effective radius (reff,f) and the logarithmic standard deviation for two Eureka sites and Thule (Greenland) were all close to 0.25 μm and 1.6 respectively. The stratospheric analogue to the columnar reff,f average was estimated to be reff,f(+) = 0.29 μm for Eureka data. Stratospheric, Raman lidar retrievals at Ny‐Ålesund, yielded a post‐SAT average of reff,f(+) = 0.27 μm. These results are ∼50% larger than the background stratospheric‐aerosol value. They are also about a factor of two larger than modeling values used in recent publications or about a factor of five larger in terms of (per particle) backscatter cross section.
- 17 February 2012
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 117 (D4)
Properties of Sarychev sulphate aerosols over the Arctic
Aerosols from the Sarychev Peak volcano entered the Arctic region less than a week after the strongest SO2eruption on June 15 and 16, 2009 and had, by the first week in July, spread out over the entire Arctic region. These predominantly stratospheric aerosols were determined to be sub‐micron in size and inferred to be composed of sulphates produced from the condensation of SO2gases emitted during the eruption. Average (500 nm) Sarychev‐induced stratospheric optical depths (SOD) over the Polar Environmental Atmospheric Research Laboratory (PEARL) at Eureka (Nunavut, Canada) were found to be between 0.03 and 0.05 during the months of July and August, 2009. This estimate, derived from sunphotometry and integrated lidar backscatter profiles was consistent with averages derived from lidar estimates over Ny‐Ålesund (Spitsbergen). The Sarychev SOD e‐folding time at Eureka, deduced from lidar profiles, was found to be approximately 4 months relative to a regression start date of July 27. These profiles initially revealed the presence of multiple Sarychev plumes between the tropopause and about 17 km altitude. After about two months, the complex vertical plume structures had collapsed into fewer, more homogeneous plumes located near the tropopause. It was found that the noisy character of daytime backscatter returns induced an artifactual minimum in the temporal, pan‐Arctic, CALIOP SOD response to Sarychev sulphates. A depolarization ratio discrimination criterion was used to separate the CALIOP stratospheric layer class into a low depolarization subclass which was more representative of Sarychev sulphates. Post‐SAT (post Sarychev Arrival Time) retrievals of the fine mode effective radius (reff,f) and the logarithmic standard deviation for two Eureka sites and Thule (Greenland) were all close to 0.25 μm and 1.6 respectively. The stratospheric analogue to the columnar reff,f average was estimated to be reff,f(+) = 0.29 μm for Eureka data. Stratospheric, Raman lidar retrievals at Ny‐Ålesund, yielded a post‐SAT average of reff,f(+) = 0.27 μm. These results are ∼50% larger than the background stratospheric‐aerosol value. They are also about a factor of two larger than modeling values used in recent publications or about a factor of five larger in terms of (per particle) backscatter cross section.
- Open Access
- 25 October 2010
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 10 (20) , 10017-10019
Comment on "Classification of aerosol properties derived from AERONET direct sun data" by Gobbi et al. (2007)
It is pointed out that the graphical, aerosol classification method of Gobbi et al. (2007) can be interpreted as a manifestation of fundamental analytical relations whose existance depends on the simple assumption that the optical effects of aerosols are essentially bimodal in nature. The families of contour lines in their "Ada" curvature space are essentially empirical and discretized illustrations of analytical parabolic forms in (α, α') space (the space formed by the continuously differentiable Angstrom exponent and its spectral derivative).
- 25 October 2010
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 10 (20) , 10017-10019
Open AccessComment on "Classification of aerosol properties derived from AERONET direct sun data" by Gobbi et al. (2007)
It is pointed out that the graphical, aerosol classification method of Gobbi et al. (2007) can be interpreted as a manifestation of fundamental analytical relations whose existance depends on the simple assumption that the optical effects of aerosols are essentially bimodal in nature. The families of contour lines in their "Ada" curvature space are essentially empirical and discretized illustrations of analytical parabolic forms in (α, α') space (the space formed by the continuously differentiable Angstrom exponent and its spectral derivative).
- 18 December 2008
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 113 (D24)
Correction to “Robust optical features of fine mode size distributions: Application to the Québec smoke event of 2002”
- 18 December 2008
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 113 (D24)
Correction to “Robust optical features of fine mode size distributions: Application to the Québec smoke event of 2002”