Cheng-Kung Cheng
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cheng-Kung Cheng has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jiann-Jong Liau
School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan
2 shared publications Chan-Tsung Yang
National Yang Ming University
1 shared publicationChang-Hung Huang
1 shared publicationChan‐Tsung Yang
Institute of Biomedical Engineering , National Yang‐Ming University , Taipei, Taiwan, 112, R.O.C.
1 shared publication- Chih-Sheng Yu
Instrument Technology Research Center, National Applied Research Laboratories 20, R&D Rd. VI, Hsinchu Science Park, Hsinchu 300, Taiwan
1 shared publication - Chih-Yu Chen
Taipei Medical University
1 shared publication
Latest Publications
- 18 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 44 (1) , 73-78
Wing-augmentation reduces femoral head cutting out of dynamic hip screw
The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus collapse, followed by lag screw cut-out through the femoral head. In this study, a novel-designed DHS with two supplemental horizontal blades was used to improve the fixation stability. In this study, nine convention DHS and 9 Orthopaedic Device Research Center (ODRC) DHSs were tested in this study. Each implant was fixed into cellular polyurethane rigid foam as a surrogate of osteoporotic femoral head. Under biaxial rocking motion, all constructs were loaded to failure point (12mm axial displacement) or up to 20,000 cycles of 1.45kN peak magnitude were achieved, whichever occurred first. The migration kinematics was continuously monitored and recorded. The final tip-to-apex distance, rotational angle and varus deformation were also recorded. The results showed that the ODRC DHS sustained significantly more loading cycles and exhibited less axial migration in comparison to the conventional DHS. The ODRC DHS showed a significantly smaller bending strain and larger torsional strain compared to the conventional DHS. The changes in tip-to-apex distance (TAD), post-study varus angle, post-study rotational angle of the ODRC DHS were all significantly less than that of the conventional DHS (p < 0.05). We concluded that the ODRC DHS augmented with two horizontal wings would increase the bone-implant interface contact surface, dissipate the load to the screw itself, which improves the migration resistance and increases the anti-rotational implant effect. In conclusion, the proposed ODRC DHS demonstrated significantly better migration resistance and anti-rotational effect in comparison to the conventional DHS construct.
- 18 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 44 (1) , 73-78
Wing-augmentation reduces femoral head cutting out of dynamic hip screw
The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus collapse, followed by lag screw cut-out through the femoral head. In this study, a novel-designed DHS with two supplemental horizontal blades was used to improve the fixation stability. In this study, nine convention DHS and 9 Orthopaedic Device Research Center (ODRC) DHSs were tested in this study. Each implant was fixed into cellular polyurethane rigid foam as a surrogate of osteoporotic femoral head. Under biaxial rocking motion, all constructs were loaded to failure point (12mm axial displacement) or up to 20,000 cycles of 1.45kN peak magnitude were achieved, whichever occurred first. The migration kinematics was continuously monitored and recorded. The final tip-to-apex distance, rotational angle and varus deformation were also recorded. The results showed that the ODRC DHS sustained significantly more loading cycles and exhibited less axial migration in comparison to the conventional DHS. The ODRC DHS showed a significantly smaller bending strain and larger torsional strain compared to the conventional DHS. The changes in tip-to-apex distance (TAD), post-study varus angle, post-study rotational angle of the ODRC DHS were all significantly less than that of the conventional DHS (p < 0.05). We concluded that the ODRC DHS augmented with two horizontal wings would increase the bone-implant interface contact surface, dissipate the load to the screw itself, which improves the migration resistance and increases the anti-rotational implant effect. In conclusion, the proposed ODRC DHS demonstrated significantly better migration resistance and anti-rotational effect in comparison to the conventional DHS construct.
- 13 March 2008
- Published by Wiley in Diabetic Medicine
- Vol. 25 (4) , 413-418
Thermoregulatory sudomotor dysfunction and diabetic neuropathy develop in parallel in at‐risk feet
Aims To establish the longitudinal relationship of foot complications to neuropathy based on a 4‐year follow‐up of diabetic patients stratified by sudomotor dysfunctions.Methods One hundred and nineteen Type 2 diabetic patients and 36 non‐diabetic subjects were initially registered in the prospective cohort study. Plantar skin temperature and sympathetic skin response (SSR) were used to monitor sympathetic mediated thermoregulation and sudomotor function. Peripheral somatic and central autonomic functions were studied using clinical, nerve conduction and cardiovascular reflex tests. At enrolment, the diabetic patients were classified into one of three groups by the progressive stages of sudomotor dysfunction: SSR+ (SSR present; 49 patients), SSR− (SSR absent; 41 patients) and at‐risk group (SSR absent but with cracked skin involving partial thickness of the dermis; 29 patients).Results The at‐risk group had 13.4 times (95% confidence interval 1.4–125.7) higher plantar ulceration rates than the other two patient groups during the 4 years. Skin temperature elevation occurred in parallel with development of foot sweating problems. There were no significant differences between the three patient groups in the ratios of abnormal heart rate variation, orthostatic test and clinical neuropathy score at follow‐up. After 4 years of follow‐up, nerve conduction abnormalities were more frequent in the at‐risk and SSR− groups than in the SSR+ group.Conclusions Early deterioration of small sympathetic fibres could not be quantified accurately by the clinical, somatic and autonomic tests. Assessing skin integrity and sudomotor function in at‐risk individuals identifies early peripheral sympathetic neuropathy, even if the patients have no overt clinical symptoms.
- 13 March 2008
- Published by Wiley in Diabetic Medicine
- Vol. 25 (4) , 413-418
Thermoregulatory sudomotor dysfunction and diabetic neuropathy develop in parallel in at‐risk feet
Aims To establish the longitudinal relationship of foot complications to neuropathy based on a 4‐year follow‐up of diabetic patients stratified by sudomotor dysfunctions.Methods One hundred and nineteen Type 2 diabetic patients and 36 non‐diabetic subjects were initially registered in the prospective cohort study. Plantar skin temperature and sympathetic skin response (SSR) were used to monitor sympathetic mediated thermoregulation and sudomotor function. Peripheral somatic and central autonomic functions were studied using clinical, nerve conduction and cardiovascular reflex tests. At enrolment, the diabetic patients were classified into one of three groups by the progressive stages of sudomotor dysfunction: SSR+ (SSR present; 49 patients), SSR− (SSR absent; 41 patients) and at‐risk group (SSR absent but with cracked skin involving partial thickness of the dermis; 29 patients).Results The at‐risk group had 13.4 times (95% confidence interval 1.4–125.7) higher plantar ulceration rates than the other two patient groups during the 4 years. Skin temperature elevation occurred in parallel with development of foot sweating problems. There were no significant differences between the three patient groups in the ratios of abnormal heart rate variation, orthostatic test and clinical neuropathy score at follow‐up. After 4 years of follow‐up, nerve conduction abnormalities were more frequent in the at‐risk and SSR− groups than in the SSR+ group.Conclusions Early deterioration of small sympathetic fibres could not be quantified accurately by the clinical, somatic and autonomic tests. Assessing skin integrity and sudomotor function in at‐risk individuals identifies early peripheral sympathetic neuropathy, even if the patients have no overt clinical symptoms.
- 1 March 2007
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 456, 159-163
The Accuracy of Posterior Condylar Angles Measured by One MR Image
The posterior condylar axis is used to establish femoral rotational alignment during total knee arthroplasty. One magnetic resonance image or computed tomography image often is used to determine the posterior condylar angle. However, the bony landmarks for determining the posterior condylar angle are not always present or obvious. We hypothesized measuring the posterior condylar angle on one slice would be no different when compared with using superimposed images with bony landmarks accurately identified in one or more slices. We analyzed magnetic resonance images of 95 knees without any bone disorders. Only 20 knees had all four bony landmarks apparent on any single slice. We compared the posterior condylar angles measured from one slice in which the medial sulcus, lateral epicondyle, or both posterior condyles were accurately identified with the angle measured from superimposed images. The average posterior condylar angle in the remaining 75 knees measured from superimposed images was 4.27° ± 1.95°, which was similar to the angle measured from one in which the lateral epicondyle was the most accurately identified (3.95° ± 1.93°). However, the largest difference (−3.53° and 4.29°) between three-dimensional and two-dimensional posterior condylar angle measurements in the worse-case scenario was unacceptable in clinical practice. We could not confirm our hypothesis: using one two-dimensional image to measure the posterior condyle angle is not accurate enough to determine its three-dimensional angle.
- 1 March 2007
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 456, 159-163
The Accuracy of Posterior Condylar Angles Measured by One MR Image
The posterior condylar axis is used to establish femoral rotational alignment during total knee arthroplasty. One magnetic resonance image or computed tomography image often is used to determine the posterior condylar angle. However, the bony landmarks for determining the posterior condylar angle are not always present or obvious. We hypothesized measuring the posterior condylar angle on one slice would be no different when compared with using superimposed images with bony landmarks accurately identified in one or more slices. We analyzed magnetic resonance images of 95 knees without any bone disorders. Only 20 knees had all four bony landmarks apparent on any single slice. We compared the posterior condylar angles measured from one slice in which the medial sulcus, lateral epicondyle, or both posterior condyles were accurately identified with the angle measured from superimposed images. The average posterior condylar angle in the remaining 75 knees measured from superimposed images was 4.27° ± 1.95°, which was similar to the angle measured from one in which the lateral epicondyle was the most accurately identified (3.95° ± 1.93°). However, the largest difference (−3.53° and 4.29°) between three-dimensional and two-dimensional posterior condylar angle measurements in the worse-case scenario was unacceptable in clinical practice. We could not confirm our hypothesis: using one two-dimensional image to measure the posterior condyle angle is not accurate enough to determine its three-dimensional angle.
- 1 January 2007
- Published by Springer Nature
- p. 673-690
Mechanical Property of Trabecular Bone of the Femoral Heads from Osteoarthritis and Osteoporosis Patients
- 1 January 2007
- Published by Springer Nature
- p. 673-690
Mechanical Property of Trabecular Bone of the Femoral Heads from Osteoarthritis and Osteoporosis Patients
- 1 September 2003
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 26 (6) , 803-808
A new internal fixation concept for the distal femoral fracture after total knee arthroplasty
A new internal fixation concept for the supracondylar femoral fracture after total knee arthroplasty (TKA) was investigated. In the new design, the intramedullary nail was fixed on the modified femoral component of the total knee prosthesis by a locking screw. The new internal fixator complex should have greater structural stiffness by increasing the structure contact area between bone and implant. To test this improvement, biomechanical tests were conducted to compare the mechanical properties (axial and torsional stiffness) of the fractured femurs that were stabilized by three different fixators (DCS plate, GSH nail and new design fixator). The compressive test and torsional test were done by the MTS Bionix858 to compare the mechanical stability of these fixators. The results showed no significant difference among groups in compressive stiffness, which meant that these three fixators could stabilize the fracture effectively in the longitudinal direction. The torsional stiffness of all three fixation groups were lower than the Intact group with significant difference. But the torsional stiffness of the new designed fixator was higher than the DCS plate and the GSH nail. The results supported the new design concept's practicality. The new design also has better initial stability in the fixation of a supracondylar femoral fracture after TKA.
- 1 September 2003
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 26 (6) , 803-808
A new internal fixation concept for the distal femoral fracture after total knee arthroplasty
A new internal fixation concept for the supracondylar femoral fracture after total knee arthroplasty (TKA) was investigated. In the new design, the intramedullary nail was fixed on the modified femoral component of the total knee prosthesis by a locking screw. The new internal fixator complex should have greater structural stiffness by increasing the structure contact area between bone and implant. To test this improvement, biomechanical tests were conducted to compare the mechanical properties (axial and torsional stiffness) of the fractured femurs that were stabilized by three different fixators (DCS plate, GSH nail and new design fixator). The compressive test and torsional test were done by the MTS Bionix858 to compare the mechanical stability of these fixators. The results showed no significant difference among groups in compressive stiffness, which meant that these three fixators could stabilize the fracture effectively in the longitudinal direction. The torsional stiffness of all three fixation groups were lower than the Intact group with significant difference. But the torsional stiffness of the new designed fixator was higher than the DCS plate and the GSH nail. The results supported the new design concept's practicality. The new design also has better initial stability in the fixation of a supracondylar femoral fracture after TKA.
- 1 March 2003
- Published by Elsevier in Clinical Biomechanics
- Vol. 18 (3) , 231-236
The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses––a biomechanical study
- 1 March 2003
- Published by Elsevier in Clinical Biomechanics
- Vol. 18 (3) , 231-236
The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses––a biomechanical study