Marco Ridolfi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marco Ridolfi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Piera Raspollini
Istituto di Fisica Applicata “Nello Carrara” del Consiglio Nazionale delle Ricerche, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Italy
4 shared publications - Bianca Maria Dinelli
Institute of Atmospheric Sciences and Climate, National Research Council (ISAC-CNR), Via Piero Gobetti, 101, 40129 Bologna, Italy
2 shared publications - Bruno Carli
Istituto di Ricerca sulle Onde Elettromagnetiche, Firenze, Italy
2 shared publications Massimo Carlotti
Univ. degli Studi di Bologna (Italy)
2 shared publications- Massimo Carlotti
Dipartimento di Chimica Industriale “Toso Montanari”, Università di Bologna, Bologna, Italy
2 shared publications - Anu Dudhia
Atmospheric, Oceanic and Planetary Physics, University of Oxford, Clarendon Laboratory, Parks Road, Oxford OX1 3PU, UK
1 shared publication
Latest Publications
- 4 February 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4539, 369-381
Geo-fit approach to the analysis of limb-scanning satellite measurements
Retrieval methods for limb-scanning measurements usually adopt the assumption of horizontal homogeneity for the parcel of atmosphere sounded by the analyzed observations. For along-track observations from an orbiting platform, the dimension of the probed parcel of atmosphere may approach 2000 km. Horizontal homogeneity assumption in the inversion algorithms induces an error on the retrieved atmospheric parameters. Two questions arise from these considerations: 1) how to characterize these errors, 2) how to avoid this assumption if the size of the induced errors is not acceptable. In order to answer these questions, an innovative forward and retrieval model (geo-fit) was developed which does not use horizontal homogeneity assumption. In this approach the radiative transfer is made through a two-dimensional inhomogeneous atmospheric field. The retrieval algorithm is based on the simultaneous analysis of all the limb-scanning measurements relating to a given orbit. This feature allows to gather information from several contiguous limb-scanning sequences on a target atmospheric parameter at a given location, and therefore to improve the trade-off between accuracy and horizontal resolution. The obtained results show that the horizontal homogeneity assumption induces a significant systematic error on the retrieved atmospheric parameters, especially in the presence of strong horizontal gradients.
- 4 February 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4539, 369-381
Geo-fit approach to the analysis of limb-scanning satellite measurements
Retrieval methods for limb-scanning measurements usually adopt the assumption of horizontal homogeneity for the parcel of atmosphere sounded by the analyzed observations. For along-track observations from an orbiting platform, the dimension of the probed parcel of atmosphere may approach 2000 km. Horizontal homogeneity assumption in the inversion algorithms induces an error on the retrieved atmospheric parameters. Two questions arise from these considerations: 1) how to characterize these errors, 2) how to avoid this assumption if the size of the induced errors is not acceptable. In order to answer these questions, an innovative forward and retrieval model (geo-fit) was developed which does not use horizontal homogeneity assumption. In this approach the radiative transfer is made through a two-dimensional inhomogeneous atmospheric field. The retrieval algorithm is based on the simultaneous analysis of all the limb-scanning measurements relating to a given orbit. This feature allows to gather information from several contiguous limb-scanning sequences on a target atmospheric parameter at a given location, and therefore to improve the trade-off between accuracy and horizontal resolution. The obtained results show that the horizontal homogeneity assumption induces a significant systematic error on the retrieved atmospheric parameters, especially in the presence of strong horizontal gradients.
- 25 January 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4063, 2-17
Recent advances in submillimeter remote sensing of the stratosphere
The capability of remote-sensing measurements of the stratosphere in the submillimetric spectral region is presented. The analysis is discussed of spectra recorder by a balloon-borne Fourier Transform spectrometer that measures the emission of the atmosphere in the submillimetric with the limb-scanning observation technique. Two problems, that have been studied with submillimetric spectroscopy, are presented in detail: the measurement of HBr and the diurnal variability of hydroxyl radical.
- 25 January 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4063, 2-17
Recent advances in submillimeter remote sensing of the stratosphere
The capability of remote-sensing measurements of the stratosphere in the submillimetric spectral region is presented. The analysis is discussed of spectra recorder by a balloon-borne Fourier Transform spectrometer that measures the emission of the atmosphere in the submillimetric with the limb-scanning observation technique. Two problems, that have been studied with submillimetric spectroscopy, are presented in detail: the measurement of HBr and the diurnal variability of hydroxyl radical.
- 1 January 2000
- Published by Springer Nature
- p. 335-347
Performances of the Near Real Time Code for MIPAS Data Analysis
- 1 January 2000
- Published by Springer Nature
- p. 335-347
Performances of the Near Real Time Code for MIPAS Data Analysis
- 20 April 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (12) , 2398-2409
Derivation of temperature and pressure from submillimetric limb observations
We demonstrate the feasibility of retrieval of temperature and pressure profiles from spaceborne limb-sounding spectroscopic measurements in the submillimetric region. Whether these profiles can be retrieved determines whether a submillimetric instrument can be self-sufficient as far as the atmospheric model is concerned or whether complementary sensors in other spectral regions, dedicated to temperature and pressure measurements, are needed. Molecular-oxygen transitions are selected for the purpose of temperature and pressure retrieval on the basis of realistic observational parameters. We use a mathematical model of the retrieval process to evaluate the information content of the spectral features and to study the trade-off between the uncertainty of the retrieved profiles and their vertical resolution. It is shown that, using only one oxygen transition and without any constraint, one can achieve uncertainties of 5% for both temperature and pressure from 10 to ∼40 km of altitude with a vertical resolution of 3 km; above 40 km the vertical resolution needs to be degraded to limit the uncertainties. The possibility of exploiting a priori information is discussed, as well as the effects of external constraints that can be used to improve the quality of the retrieved profiles. The sources of systematic error that need to be considered for the compilation of the total error budget are also evaluated.
- 20 April 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (12) , 2398-2409
Derivation of temperature and pressure from submillimetric limb observations
We demonstrate the feasibility of retrieval of temperature and pressure profiles from spaceborne limb-sounding spectroscopic measurements in the submillimetric region. Whether these profiles can be retrieved determines whether a submillimetric instrument can be self-sufficient as far as the atmospheric model is concerned or whether complementary sensors in other spectral regions, dedicated to temperature and pressure measurements, are needed. Molecular-oxygen transitions are selected for the purpose of temperature and pressure retrieval on the basis of realistic observational parameters. We use a mathematical model of the retrieval process to evaluate the information content of the spectral features and to study the trade-off between the uncertainty of the retrieved profiles and their vertical resolution. It is shown that, using only one oxygen transition and without any constraint, one can achieve uncertainties of 5% for both temperature and pressure from 10 to ∼40 km of altitude with a vertical resolution of 3 km; above 40 km the vertical resolution needs to be degraded to limit the uncertainties. The possibility of exploiting a priori information is discussed, as well as the effects of external constraints that can be used to improve the quality of the retrieved profiles. The sources of systematic error that need to be considered for the compilation of the total error budget are also evaluated.
- 1 January 1998
- Published by SPIE-Intl Soc Optical Eng
Optimized forward and retrieval model for MIPAS near-real-time data processing
- 1 January 1998
- Published by SPIE-Intl Soc Optical Eng
Optimized forward and retrieval model for MIPAS near-real-time data processing
- 15 August 1997
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 24 (16) , 2003-2006
Measurement of the isotopic ratio distribution of HD16O and H216O in the 20–38 km altitude range from far‐infrared spectra
- 15 August 1997
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 24 (16) , 2003-2006
Measurement of the isotopic ratio distribution of HD16O and H216O in the 20–38 km altitude range from far‐infrared spectra