Jorge J. Rocca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jorge J. Rocca has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- Carmen S. Menoni
Colorado State University
8 shared publications Mario C. Marconi
Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, USA
8 shared publications- Mark Berrill
Oak Ridge National Laboratory
8 shared publications Y. Wang
NSF ERC for Extreme Ultraviolet Science and Technology, Colorado State University, Fort Collins, Colorado 80523, USA
8 shared publications- David Alessi
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
6 shared publications Jorge Filevich
NSF ERC for Extreme Ultraviolet Science and Technology and Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
6 shared publications
Latest Publications
- Open Access
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (1) , 1-15
Using Temporally Synthesized Laser Pulses to Enhance the Conversion Efficiency of Sn Plasmas for EUV Lithography
We have studied the laser pulse shape dependence of the conversion efficiency of $\lambda = 1.03 \mu m$ laser energy into 13.5 nm extreme ultraviolet (EUV) emission from a Sn laser-produced plasma. Laser pulses of arbitrary temporal shape ranging from hundreds of picoseconds to several nanoseconds were generated using a programmable pulse synthesizer based on a diode-pumped chirped pulse amplification Yb: YAG laser. Measurements show that the conversion efficiency favors the use of nearly square pulses of duration longer than 2 ns, in agreement with hydrodynamic/atomic physics simulations. A 35% increase in conversion efficiency was obtained when Q-switched pulses were substituted by square pulses of a similar duration. Experiments conducted irradiating a Sn target with a sequence of two time-delayed 250 ps pulses showed a 30 percent increase in the EUV yield respect to a single pulse of the same total energy when the pulse separation was optimum at 2.1 ns. This suggests that re-heating of the plasma with delayed laser pulses could be used to improve the EUV yield. The spectroscopic characterization of EUV emission and in-band EUV images that characterize the source size are also presented.- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (1) , 1-15
Open AccessUsing Temporally Synthesized Laser Pulses to Enhance the Conversion Efficiency of Sn Plasmas for EUV Lithography
We have studied the laser pulse shape dependence of the conversion efficiency of $\lambda = 1.03 \mu m$ laser energy into 13.5 nm extreme ultraviolet (EUV) emission from a Sn laser-produced plasma. Laser pulses of arbitrary temporal shape ranging from hundreds of picoseconds to several nanoseconds were generated using a programmable pulse synthesizer based on a diode-pumped chirped pulse amplification Yb: YAG laser. Measurements show that the conversion efficiency favors the use of nearly square pulses of duration longer than 2 ns, in agreement with hydrodynamic/atomic physics simulations. A 35% increase in conversion efficiency was obtained when Q-switched pulses were substituted by square pulses of a similar duration. Experiments conducted irradiating a Sn target with a sequence of two time-delayed 250 ps pulses showed a 30 percent increase in the EUV yield respect to a single pulse of the same total energy when the pulse separation was optimum at 2.1 ns. This suggests that re-heating of the plasma with delayed laser pulses could be used to improve the EUV yield. The spectroscopic characterization of EUV emission and in-band EUV images that characterize the source size are also presented. - 1 January 2018
- Published by Optica Publishing Group
- p. STu3M.1
PW-class Laser Operation at 3.3 Hz and High Contrast Ultra-intense λ=400 nm Beamline
We demonstrated 0.85PW, 30fs pulses at a repetition rate of 3.3Hz from a Ti:Sapphire laser. Ultra-high contrast λ=400 nm fs pulses were generated with > 40% efficiency and focused to an intensity of 6.5×1021W/cm2.
- 1 January 2018
- Published by Optica Publishing Group
- p. STu3M.1
PW-class Laser Operation at 3.3 Hz and High Contrast Ultra-intense λ=400 nm Beamline
We demonstrated 0.85PW, 30fs pulses at a repetition rate of 3.3Hz from a Ti:Sapphire laser. Ultra-high contrast λ=400 nm fs pulses were generated with > 40% efficiency and focused to an intensity of 6.5×1021W/cm2.
- 1 January 2018
- Published by Optica Publishing Group
- p. SM1N.5
In Situ 3-D Temperature Mapping of High Average Power Cryogenic Laser Amplifiers
We demonstrate an accurate, in situ, noninvasive optical technique to generate 2-D and 3-D maps of the temperature profile within cryogenic amplifiers operating at high average power.
- 1 January 2018
- Published by Optica Publishing Group
- p. SM1N.5
In Situ 3-D Temperature Mapping of High Average Power Cryogenic Laser Amplifiers
We demonstrate an accurate, in situ, noninvasive optical technique to generate 2-D and 3-D maps of the temperature profile within cryogenic amplifiers operating at high average power.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTh5C.1
Micro-Scale Fusion in Dense Nanowire Arrays Irradiated by Femtosecond Laser Pulses of Relativistic Intensity
Irradiation of deuterated nanowire arrays with femtosecond pulses of relativistic intensity creates ultra-high energy density plasmas where deuterons are accelerated to MeV energies, efficiently driving D-D fusion reactions with record neutron yield for joule-level lasers.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTh5C.1
Micro-Scale Fusion in Dense Nanowire Arrays Irradiated by Femtosecond Laser Pulses of Relativistic Intensity
Irradiation of deuterated nanowire arrays with femtosecond pulses of relativistic intensity creates ultra-high energy density plasmas where deuterons are accelerated to MeV energies, efficiently driving D-D fusion reactions with record neutron yield for joule-level lasers.
- 1 January 2016
- Published by Optica Publishing Group
- p. ThA.10
High performance interference coatings for 1-2μm high energy lasers
High reflection Ta2O5/SiO2 and HfO2/SiO2 interference coatings that incorporate top thick layers of SiO2 with superior performance are demonstrated for 1-2μm high energy lasers are demonstrated.
- 1 January 2016
- Published by Optica Publishing Group
- p. ThA.10
High performance interference coatings for 1-2μm high energy lasers
High reflection Ta2O5/SiO2 and HfO2/SiO2 interference coatings that incorporate top thick layers of SiO2 with superior performance are demonstrated for 1-2μm high energy lasers are demonstrated.
- Open Access
- 5 January 2015
- Published by Defense Technical Information Center (DTIC)
Ultra-sensitive Absorption Diagnostics of Thin Films for High-power Laser Interference Coatings
The goal of this project was to demonstrate a simple method to measure absorption loss in thin dielectrics films, in particular in multilayer coatings for high power lasers in which very low absorption losses are required. The absorption characterization method is a photo-thermal technique based on thermal lensing. The method measures the defocusing of an incident probe beam caused by a thermal lens generated by absorption of the incident pump beam. The simplicity and versatility of the method allow it to be incorporated into a deposition chamber to measure absorption loss in situ. Excellent results were obtained with both amplitude modulated and pulsed pump laser beams. Results obtained in this project demonstrated the method can measure absorption losses below 10 ppm at 1 m wavelength. Future work consists of the development of a prototype suitable for incorporation into the deposition chamber. Such powerful diagnostics does not presently exist.
- 5 January 2015
- Published by Defense Technical Information Center (DTIC)
Open AccessUltra-sensitive Absorption Diagnostics of Thin Films for High-power Laser Interference Coatings
The goal of this project was to demonstrate a simple method to measure absorption loss in thin dielectrics films, in particular in multilayer coatings for high power lasers in which very low absorption losses are required. The absorption characterization method is a photo-thermal technique based on thermal lensing. The method measures the defocusing of an incident probe beam caused by a thermal lens generated by absorption of the incident pump beam. The simplicity and versatility of the method allow it to be incorporated into a deposition chamber to measure absorption loss in situ. Excellent results were obtained with both amplitude modulated and pulsed pump laser beams. Results obtained in this project demonstrated the method can measure absorption losses below 10 ppm at 1 m wavelength. Future work consists of the development of a prototype suitable for incorporation into the deposition chamber. Such powerful diagnostics does not presently exist.
- 21 November 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (23) , 5004-5007
Single-shot soft x-ray laser linewidth measurement using a grating interferometer
The linewidth of a 14.7 nm wavelength Ni-like Pd soft x-ray laser was measured in a single shot using a soft x-ray diffraction grating interferometer. The instrument uses the time delay introduced by the gratings across the beam to measure the temporal coherence. The spectral linewidth of the Ni-like Pd lasing line was measured to be from the Fourier transform of the fringe visibility. This single shot linewidth measurement technique provides a rapid and accurate way to determine the temporal coherence of soft x-ray lasers that can contribute to the development of femtosecond plasma-based soft x-ray lasers.- 21 November 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (23) , 5004-5007
Single-shot soft x-ray laser linewidth measurement using a grating interferometer
The linewidth of a 14.7 nm wavelength Ni-like Pd soft x-ray laser was measured in a single shot using a soft x-ray diffraction grating interferometer. The instrument uses the time delay introduced by the gratings across the beam to measure the temporal coherence. The spectral linewidth of the Ni-like Pd lasing line was measured to be from the Fourier transform of the fringe visibility. This single shot linewidth measurement technique provides a rapid and accurate way to determine the temporal coherence of soft x-ray lasers that can contribute to the development of femtosecond plasma-based soft x-ray lasers.- 1 January 2013
- Published by Optica Publishing Group
- p. ThB.1
Point Defects in Sc2O3 Thin Films by Ion Beam Sputtering
We show that the concentration of oxygen defects trapped in Sc2O3 films by ion beam sputtering can be controlled by modifying deposition conditions. These defects play a role in the optical and structural properties of the thin film metal-oxides.
- 1 January 2013
- Published by Optica Publishing Group
- p. ThB.1
Point Defects in Sc2O3 Thin Films by Ion Beam Sputtering
We show that the concentration of oxygen defects trapped in Sc2O3 films by ion beam sputtering can be controlled by modifying deposition conditions. These defects play a role in the optical and structural properties of the thin film metal-oxides.
- 1 January 2012
- Published by Optica Publishing Group
- p. QTu3H.6
Demonstration of an 8.85 nm Gain-Saturated Table-Top Soft X-Ray Laser and Lasing down to 7.4 nm
We report the efficient generation of a gain-saturated 8.85 nm wavelength table-top soft x-ray laser operating at 1 Hz repetition rate and the observation of lasing at wavelengths as short as 7.36 nm in lanthanide ions.
- 1 January 2012
- Published by Optica Publishing Group
- p. QTu3H.6
Demonstration of an 8.85 nm Gain-Saturated Table-Top Soft X-Ray Laser and Lasing down to 7.4 nm
We report the efficient generation of a gain-saturated 8.85 nm wavelength table-top soft x-ray laser operating at 1 Hz repetition rate and the observation of lasing at wavelengths as short as 7.36 nm in lanthanide ions.