NHN. D. Harris

N. D. Harris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


N. D. Harris has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Measurement of high resolution ECG QT interval during controlled euglycaemia and hypoglycaemia

    by R H Ireland, R T C E Robinson, S R Heller, J L B Marques, N D Harris

    During hypoglycaemia, typically there is a change in the surface ECG characterized by a flattened and prolonged T wave, often accompanied by a fused U wave. The QT interval is a useful parameter for quantifying the ECG morphology. However, reliable measurement of QT is not straightforward, particularly for hypoglycaemic ECG morphology. The objective of this study was to compare the ability of two methods of QT measurement to distinguish between ECGs recorded during euglycaemia and hypoglycaemia. The first method involves manually setting the intersection of the isoelectric line and the T wave or, where this is not possible, the nadir between the T and U wave. The second method is semi-automatic and fits a tangent to the point of maximum gradient on the downward slope of the T wave. Two independent observers used both methods to measure the QT for high resolution ECG data recorded during a study of 17 non-diabetic subjects undergoing controlled euglycaemia and hypoglycaemia. Using the mean results of the two observers, the mean +/- SD increase in heart rate corrected QT, QTc, for ECGs recorded during euglycaemia and hypoglycaemia was 32 +/- 25 ms for the non-tangent method and 60 +/- 24 ms for the tangent method. Therefore, the tangent method provides greater distinction between ECGs recorded during euglycaemia and hypoglycaemia than the non-tangent method. A potential clinical application could be the non-invasive detection of impending hypoglycaemia at night, which would be of significant benefit to adults and young children with diabetes.


  • A portable system for monitoring physiological responses to hypoglycaemia

    by N. D. Harris, S. B. Baykouchev, J. L. B. Marques, T. Cochrane, E. George, S. R. Heller, J. D. Ward

    Hypoglycaemia is the most common complication affecting people with Type 1 insulin dependent diabetes mellitus. Its onset is characterized by symptoms which include sweating, tremor, palpitations, loss of concentration and tiredness. As part of a research project to investigate the mechanisms of hypoglycaemia we have developed an ambulatory system to monitor and. record pulsatile changes in blood flow, pulse internal, body temperature and skin impedance. The system uses a pocket computer (Atari Portfolio) to collect and store the data on a memory card. The analogue system consists of two thermocouples, an infrared photoplethysmograph and skin impedance monitoring circuit. To conserve power the system is programmed to make measurements for 2 min every 10 min; using this regimen over 16 h of data can be stored. Data collected during a spontaneous overnight hypoglycaemic episode are presented and also a comparison between continuous and intermittent data collection during a period of induced hypoglycaemia. The system is being used to investigate the physiological responses to hypoglycaemia but could easily be adapted for monitoring other physiological signals.