Hirotaka Obana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hirotaka Obana has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Shinjiro Hori
Osaka Prefectural Institute of Public Health, 1-3-69, Nakamichi, Higashinari, Osaka, 5370025, Japan
5 shared publications- Kazuhiko Akutsu
Osaka Institute of Public Health
4 shared publications Masahiro Okihashi
Osaka Prefectural Institute of Public Health, 1-3-69, Nakamichi, Higashinari, Osaka, 5370025, Japan
4 shared publicationsS Hori
3 shared publicationsT Kashimoto
3 shared publicationsYoko Kitagawa
Osaka Prefectural Institute of Public Health, 1-3-69, Nakamichi, Higashinari, Osaka, 5370025, Japan
2 shared publications
Latest Publications
- 19 July 2005
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 53 (17) , 6603-6608
Analysis of 2-Alkylcyclobutanones with Accelerated Solvent Extraction To Detect Irradiated Meat and Fish
A new analytical procedure has been developed to analyze 2-alkylcyclobutanones to detect gamma-ray-irradiated fat-containing foodstuffs. Samples were extracted with an accelerated solvent extraction system via hot and pressurized ethyl acetate in cells. A large amount of fat in the extract was precipitated and removed with filtration by standing at -20 degrees C after the addition of acetonitrile. The extract was further cleaned with a 1 g silica gel mini column, and the radiolytic compounds of 2-docecylcyclobutanone (2-DCB) and 2-tetradecylcyclobutanone (2-TCB) were determined with gas chromatography with mass spectrometry (GC/MS). Sample preparation time before GC/MS was 7-8 h. At first, the procedure was evaluated with a recovery test in eight samples spiked with 2-DCB and 2-TCB at 20 ng/g, resulting in 70-105% recoveries with mostly less than 10% relative standard deviations. The procedure was further evaluated with beef, pork, chicken, and salmon samples irradiated with gamma-rays from 0.7 to 7.0 kGy at -19 degrees C. Both 2-DCB and 2-TCB in most samples were detected with good dose-response relations at all doses, while salmon was detected more than 2 kGy irradiation. The amounts of 2-alkylcyclobutanones produced reflected precursor fatty acids levels in samples, especially for the combination of 2-TCB and stearic acid. The results indicated that the production rate of 2-TCB to stearic acid was more obvious than that of 2-DCB to palmitic acid in frozen samples with gamma-ray irradiation.
- 19 July 2005
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 53 (17) , 6603-6608
Analysis of 2-Alkylcyclobutanones with Accelerated Solvent Extraction To Detect Irradiated Meat and Fish
A new analytical procedure has been developed to analyze 2-alkylcyclobutanones to detect gamma-ray-irradiated fat-containing foodstuffs. Samples were extracted with an accelerated solvent extraction system via hot and pressurized ethyl acetate in cells. A large amount of fat in the extract was precipitated and removed with filtration by standing at -20 degrees C after the addition of acetonitrile. The extract was further cleaned with a 1 g silica gel mini column, and the radiolytic compounds of 2-docecylcyclobutanone (2-DCB) and 2-tetradecylcyclobutanone (2-TCB) were determined with gas chromatography with mass spectrometry (GC/MS). Sample preparation time before GC/MS was 7-8 h. At first, the procedure was evaluated with a recovery test in eight samples spiked with 2-DCB and 2-TCB at 20 ng/g, resulting in 70-105% recoveries with mostly less than 10% relative standard deviations. The procedure was further evaluated with beef, pork, chicken, and salmon samples irradiated with gamma-rays from 0.7 to 7.0 kGy at -19 degrees C. Both 2-DCB and 2-TCB in most samples were detected with good dose-response relations at all doses, while salmon was detected more than 2 kGy irradiation. The amounts of 2-alkylcyclobutanones produced reflected precursor fatty acids levels in samples, especially for the combination of 2-TCB and stearic acid. The results indicated that the production rate of 2-TCB to stearic acid was more obvious than that of 2-DCB to palmitic acid in frozen samples with gamma-ray irradiation.
- 22 March 2003
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 51 (9) , 2501-2505
Determination of Neonicotinoid Pesticide Residues in Vegetables and Fruits with Solid Phase Extraction and Liquid Chromatography Mass Spectrometry
A rapid and simple extraction method for the simultaneous analysis of five neonicotinoid insecticides has been developed. Twelve different fruit and vegetable matrixes were extracted with methanol and cleaned up using a graphitized carbon solid phase extraction cartridge loading with a 20% methanol solution. The concentrated eluate after methanol elution was then analyzed for pesticide residues by liquid chromatography/mass spectrometry in the APCI positive mode. The five pesticides including nitenpyram, thiamethoxam, imidacloprid, acetamiprid, and thiacloprid were recovered at 70−95% at spike levels of 0.1 and 1 mg/kg in bell pepper, cucumber, eggplant, grape, grapefruit, Japanese radish, peach, pear, potato, rice, and tomato. Relative standard deviations were less than 10% for all of the recovery tests. The proposed method is fast, easy to perform, and could be utilized for regular monitoring of pesticide residues. Keywords: Neonicotinoid; pesticide; insecticide; nitenpyram; thiamethoxam; imidacloprid; acetamiprid; thiacloprid; LC-MS; food
- 22 March 2003
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 51 (9) , 2501-2505
Determination of Neonicotinoid Pesticide Residues in Vegetables and Fruits with Solid Phase Extraction and Liquid Chromatography Mass Spectrometry
A rapid and simple extraction method for the simultaneous analysis of five neonicotinoid insecticides has been developed. Twelve different fruit and vegetable matrixes were extracted with methanol and cleaned up using a graphitized carbon solid phase extraction cartridge loading with a 20% methanol solution. The concentrated eluate after methanol elution was then analyzed for pesticide residues by liquid chromatography/mass spectrometry in the APCI positive mode. The five pesticides including nitenpyram, thiamethoxam, imidacloprid, acetamiprid, and thiacloprid were recovered at 70−95% at spike levels of 0.1 and 1 mg/kg in bell pepper, cucumber, eggplant, grape, grapefruit, Japanese radish, peach, pear, potato, rice, and tomato. Relative standard deviations were less than 10% for all of the recovery tests. The proposed method is fast, easy to perform, and could be utilized for regular monitoring of pesticide residues. Keywords: Neonicotinoid; pesticide; insecticide; nitenpyram; thiamethoxam; imidacloprid; acetamiprid; thiacloprid; LC-MS; food
- 25 June 2002
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 50 (16) , 4464-4467
Determination of Acetamiprid, Imidacloprid, and Nitenpyram Residues in Vegetables and Fruits by High-Performance Liquid Chromatography with Diode-Array Detection
Determination of 3 neonicotinoid insecticides, nitenpyram, imidacloprid, and acetamiprid, was studied. Vegetables and fruits were extracted with acetonitrile. The crude extract was passed through a weak anion-exchange cartridge (PSA). The effluent was subjected to silica gel cartridge. Imidacloprid and acetamiprid were eluted with 10 mL of 4:6 (v/v) acetone/hexane, followed by nitenpyram with acetone (20 mL). Pesticides were determined by HPLC with a C-18 column and diode-array detection system. Imidacloprid and acetamiprid were recovered at about 90% at the spike levels with 0.2 and 2 mg/kg in cucumber, potato, tomato, eggplant, Japanese radish, and grape. Nitenpyram was recovered at 64−80%. Relative standard deviations were less than 10% throughout all the recovery tests. In the residue analysis, agriculturally incurred pesticides at 0.08−0.14 mg/kg were designated with UV spectra compared with respective reference standards. Keywords: Neonicotinoid; insecticides; nitenpyram; imidacloprid; acetamiprid; HPLC; diode-array; pesticide; food
- 25 June 2002
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 50 (16) , 4464-4467
Determination of Acetamiprid, Imidacloprid, and Nitenpyram Residues in Vegetables and Fruits by High-Performance Liquid Chromatography with Diode-Array Detection
Determination of 3 neonicotinoid insecticides, nitenpyram, imidacloprid, and acetamiprid, was studied. Vegetables and fruits were extracted with acetonitrile. The crude extract was passed through a weak anion-exchange cartridge (PSA). The effluent was subjected to silica gel cartridge. Imidacloprid and acetamiprid were eluted with 10 mL of 4:6 (v/v) acetone/hexane, followed by nitenpyram with acetone (20 mL). Pesticides were determined by HPLC with a C-18 column and diode-array detection system. Imidacloprid and acetamiprid were recovered at about 90% at the spike levels with 0.2 and 2 mg/kg in cucumber, potato, tomato, eggplant, Japanese radish, and grape. Nitenpyram was recovered at 64−80%. Relative standard deviations were less than 10% throughout all the recovery tests. In the residue analysis, agriculturally incurred pesticides at 0.08−0.14 mg/kg were designated with UV spectra compared with respective reference standards. Keywords: Neonicotinoid; insecticides; nitenpyram; imidacloprid; acetamiprid; HPLC; diode-array; pesticide; food
- 15 August 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (9) , 1529-1534
Multiresidue analysis of pesticides in vegetables and fruits using two-layered column with graphitized carbon and water absorbent polymer
A high-throughput multiresidue analysis of pesticides in non-fatty vegetables and fruits was developed. The method consisted of a single extraction and a single clean-up procedure. Food samples were extracted with ethyl acetate and the mixture of extract and food dregs were poured directly into the clean-up column. The clean-up column consisted of two layers of water-absorbent polymer (upper) and graphitized carbon (lower), which were packed in a reservoir (75 ml ) of a cartridge column. The polymer removed water in the extract while the carbon performed clean-up. In a recovery test, 110 pesticides were spiked and average recoveries were more than 95% from spinach and orange. Most pesticides were recovered in the range 70–115% with RSD usually <10% for five experiments. The residue analyses were performed by the extraction of 12 pesticides from 13 samples. The two methods resulted in similar residue levels except chlorothalonil in celery, for which the result was lower with the proposed method. The results confirmed that the proposed method could be applied to monitoring of pesticide residue in foods.
- 15 August 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (9) , 1529-1534
Multiresidue analysis of pesticides in vegetables and fruits using two-layered column with graphitized carbon and water absorbent polymer
A high-throughput multiresidue analysis of pesticides in non-fatty vegetables and fruits was developed. The method consisted of a single extraction and a single clean-up procedure. Food samples were extracted with ethyl acetate and the mixture of extract and food dregs were poured directly into the clean-up column. The clean-up column consisted of two layers of water-absorbent polymer (upper) and graphitized carbon (lower), which were packed in a reservoir (75 ml ) of a cartridge column. The polymer removed water in the extract while the carbon performed clean-up. In a recovery test, 110 pesticides were spiked and average recoveries were more than 95% from spinach and orange. Most pesticides were recovered in the range 70–115% with RSD usually <10% for five experiments. The residue analyses were performed by the extraction of 12 pesticides from 13 samples. The two methods resulted in similar residue levels except chlorothalonil in celery, for which the result was lower with the proposed method. The results confirmed that the proposed method could be applied to monitoring of pesticide residue in foods.
- 1 January 1999
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 124 (8) , 1159-1165
Multiresidue analysis of pesticides in vegetables and fruits using a high capacity absorbent polymer for water
A single extraction and a single clean-up procedure was developed for multi-residue analysis of pesticides in non-fatty vegetables and fruits. The method involves the use of a high capacity absorbent polymer for water as a drying agent in extraction from wet food samples and of a graphitized carbon column for clean-up. A homogeneously chopped food sample (20 g) and polymer (3 g) were mixed to absorb water from the sample and then 10 min later the mixture was vigorously extracted with ethyl acetate (100 ml). The extract (50 ml), separated by filtration, was loaded on a graphitized carbon column without concentration. Additional ethyl acetate (50 ml) was also eluted and both eluates were concentrated to 5 ml for analysis. The procedure for sample preparation was completed within 2 h. In a recovery test, 107 pesticides were spiked and average recoveries were more than 80% from asparagus, orange, potato and strawberry. Most pesticides were recovered in the range 70–120% with usually less than a 10% RSD for six experiments. The results indicated that a single extraction with ethyl acetate in the presence of polymer can be applied to the monitoring of pesticide residues in foods.
- 1 January 1999
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 124 (8) , 1159-1165
Multiresidue analysis of pesticides in vegetables and fruits using a high capacity absorbent polymer for water
A single extraction and a single clean-up procedure was developed for multi-residue analysis of pesticides in non-fatty vegetables and fruits. The method involves the use of a high capacity absorbent polymer for water as a drying agent in extraction from wet food samples and of a graphitized carbon column for clean-up. A homogeneously chopped food sample (20 g) and polymer (3 g) were mixed to absorb water from the sample and then 10 min later the mixture was vigorously extracted with ethyl acetate (100 ml). The extract (50 ml), separated by filtration, was loaded on a graphitized carbon column without concentration. Additional ethyl acetate (50 ml) was also eluted and both eluates were concentrated to 5 ml for analysis. The procedure for sample preparation was completed within 2 h. In a recovery test, 107 pesticides were spiked and average recoveries were more than 80% from asparagus, orange, potato and strawberry. Most pesticides were recovered in the range 70–120% with usually less than a 10% RSD for six experiments. The results indicated that a single extraction with ethyl acetate in the presence of polymer can be applied to the monitoring of pesticide residues in foods.
- 1 January 1997
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 122 (3) , 217-220
Determination of Organophosphorus Pesticides in Foods Using an Accelerated Solvent Extraction System
Residual organophosphorus pesticides in foods were determined by accelerated solvent extraction (ASE), gel permeation chromatography and GC–FPD. Pesticides were extracted at 100 °C under 1500 psi pressure in less than 20 min. Wet samples were extracted after mixing with Extrelut drying agent. Four foods were spiked with 19 pesticides at 0.1 ppm or less. The average recoveries of these pesticides were 80–90% and the precision was <10%. Both methamidophos and acephate gave 37–50% recoveries and 6–40% precision. These results suggested that ASE can be used to extract residues of organophosphorus pesticides in foods.
- 1 January 1997
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 122 (3) , 217-220
Determination of Organophosphorus Pesticides in Foods Using an Accelerated Solvent Extraction System
Residual organophosphorus pesticides in foods were determined by accelerated solvent extraction (ASE), gel permeation chromatography and GC–FPD. Pesticides were extracted at 100 °C under 1500 psi pressure in less than 20 min. Wet samples were extracted after mixing with Extrelut drying agent. Four foods were spiked with 19 pesticides at 0.1 ppm or less. The average recoveries of these pesticides were 80–90% and the precision was <10%. Both methamidophos and acephate gave 37–50% recoveries and 6–40% precision. These results suggested that ASE can be used to extract residues of organophosphorus pesticides in foods.
- 1 May 1987
- Vol. 78 (5) , 281-5
[Studies on the therapeutic effect of squalane on symptoms of PCDFs poisoning in monkeys].
- 1 May 1987
- Vol. 78 (5) , 281-5
[Studies on the therapeutic effect of squalane on symptoms of PCDFs poisoning in monkeys].
- 1 May 1985
- Vol. 76 (5) , 190-5
[Studies on therapeutic effect of 13-cis retinoic acid and squalene on symptoms of PCDFs poisoning in monkeys].
- 1 May 1985
- Vol. 76 (5) , 190-5
[Studies on therapeutic effect of 13-cis retinoic acid and squalene on symptoms of PCDFs poisoning in monkeys].