James Parker MD McCulley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Parker MD McCulley has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Ward E. Shine
5 shared publicationsH Dwight Cavanagh
3 shared publicationsIgor A. Butovich
From the Department of Ophthalmology, The University of Texas Southwestern Medical Center at Dallas, TX
3 shared publicationsShady T. Awwad
Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX 75390-9057, USA
3 shared publicationsXiaohong Wang
Department of Ophthalmology, The University of Texas Southwestern Medical Center at Dallas, 75390-9057, USA
3 shared publicationsEduardo Uchiyama
Department of Ophthalmology, The University of Texas Southwestern Medical Center at Dallas, TX, USA
2 shared publications
Latest Publications
- 1 June 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38 (3) , 228-231
Ocular surface involvements in ectrodactyly-ectodermal dysplasia-cleft syndrome
- 1 June 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38 (3) , 228-231
Ocular surface involvements in ectrodactyly-ectodermal dysplasia-cleft syndrome
- 1 May 2013
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 39 (3) , 220-227
The Accuracy of the Double-K Adjustment for Third-Generation Intraocular Lens Calculation Formulas in Previous Keratorefractive Surgery Eyes
Purpose: To evaluate the effect of the double-K (DK) modification on third-generation formulas. Methods: Thirty-eight previously myopic and 24 previously hyperopic eyes that underwent phacoemulsification with intraocular lens (IOL) insertion after Laser in situ keratomileusis (LASIK) were evaluated. Pre-LASIK refraction and keratometry, post-LASIK topography, axial length (AL), IOL type and power, and 1-month postphacoemulsification refraction were recorded spherical equivalent after phacoemulsification (SEpostphaco). Measured corneal power was adjusted using published and validated methods for postmyopic and posthyperopic LASIK. For each eye, and using SEpostphaco, different DK-IOL formulas were used to calculate the corresponding IOL power, the outcome measure, which was compared with the implanted IOL. Results: DK-Holladay 1 yielded the highest Pearson correlation coefficient (PCC), 0.955 for myopes and 0.943 for high myopes (AL>26 mm). Mean error (ME) and mean absolute error (MAE) for myopes for DK Sanders-Retzlaff-Kraff theoretical formula [DK-SRK/T] were 0.44±0.84 D and 0.75±0.61 D for DK-SRK/T compared with −0.04±0.67 D and 0.52±0.40 D for DK-Holladay 1 (PP=0.016, respectively), and 0.03±0.88 and 0.64±0.58 for DK-Hoffer Q. For high myopes, ME and MAE were 0.75±0.81 D and 0.84±0.69 D for DK-SRK/T, and −0.05±0.74 D (P1.5 D, compared with 0% for DK-Holladay 1 and 14% for DK-Hoffer-Q. Eyes with previous hyperopic LASIK faired similarly for all formulas, with similar PCCs, and only 8% in each category with MAE>1.5 D. Conclusions: DK-SRK/T overestimates IOL power in eyes with large AL, especially with concomitant steep pre-lasik keratometry. Among third-generation formulas, DK-Holladay 1 seems more accurate to use in postmyopic LASIK eyes.
- 1 May 2013
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 39 (3) , 220-227
The Accuracy of the Double-K Adjustment for Third-Generation Intraocular Lens Calculation Formulas in Previous Keratorefractive Surgery Eyes
Purpose: To evaluate the effect of the double-K (DK) modification on third-generation formulas. Methods: Thirty-eight previously myopic and 24 previously hyperopic eyes that underwent phacoemulsification with intraocular lens (IOL) insertion after Laser in situ keratomileusis (LASIK) were evaluated. Pre-LASIK refraction and keratometry, post-LASIK topography, axial length (AL), IOL type and power, and 1-month postphacoemulsification refraction were recorded spherical equivalent after phacoemulsification (SEpostphaco). Measured corneal power was adjusted using published and validated methods for postmyopic and posthyperopic LASIK. For each eye, and using SEpostphaco, different DK-IOL formulas were used to calculate the corresponding IOL power, the outcome measure, which was compared with the implanted IOL. Results: DK-Holladay 1 yielded the highest Pearson correlation coefficient (PCC), 0.955 for myopes and 0.943 for high myopes (AL>26 mm). Mean error (ME) and mean absolute error (MAE) for myopes for DK Sanders-Retzlaff-Kraff theoretical formula [DK-SRK/T] were 0.44±0.84 D and 0.75±0.61 D for DK-SRK/T compared with −0.04±0.67 D and 0.52±0.40 D for DK-Holladay 1 (PP=0.016, respectively), and 0.03±0.88 and 0.64±0.58 for DK-Hoffer Q. For high myopes, ME and MAE were 0.75±0.81 D and 0.84±0.69 D for DK-SRK/T, and −0.05±0.74 D (P1.5 D, compared with 0% for DK-Holladay 1 and 14% for DK-Hoffer-Q. Eyes with previous hyperopic LASIK faired similarly for all formulas, with similar PCCs, and only 8% in each category with MAE>1.5 D. Conclusions: DK-SRK/T overestimates IOL power in eyes with large AL, especially with concomitant steep pre-lasik keratometry. Among third-generation formulas, DK-Holladay 1 seems more accurate to use in postmyopic LASIK eyes.
- 1 August 2011
- Published by Wolters Kluwer Health in Cornea
- Vol. 30 (8) , 843-847
Changes in the Evaporation Rate of Tear Film After Digital Expression of Meibomian Glands in Patients With and Without Dry Eye
Purpose: To evaluate the effect of excess meibum on tear evaporation rate in patients with and without dry eye. Methods: Eleven healthy subjects and 16 patients with dry eye were tested. The dry eye group was divided into 2 subgroups: classic keratoconjunctivitis sicca (KCS) with clear and easily expressed meibum and KCS with meibomian gland dysfunction (MGD) with turbid secretions and difficult-to-express meibum. Evaporative measurements were performed at baseline and after digital expression of meibomian glands at 12, 24, 36, and 48 minutes. Two ranges of relative humidity were used, 25% to 35% and 35% to 45%. The data were expressed as microliters per square centimeter per minute. Results: An increase in the evaporation rate of the tear film was noted for all measurements at both relative humidities in the classic KCS and KCS with MGD groups compared with healthy subjects (P < 0.05). The average evaporation rates at relative humidities of 25% to 35% and 35% to 45% were 0.056 ± 0.016 and 0.040 ± 0.008 for the classic KCS group; 0.055 ± 0.026 and 0.037 ± 0.019 for the KCS with MGD group and 0.033 ± 0.012 and 0.023 ± 0.008 for the healthy group. Also, a decrease in the evaporation rate was observed in the healthy and KCS with MGD groups between baseline and the first measurement after digital expression for both relative humidities (P < 0.05). The classic KCS group did not show any changes after expression. Conclusions: Classic KCS and KCS with MGD groups showed an increase in tear evaporation rates compared with the healthy group. Aqueous tear evaporation diminished in the healthy and KCS with MGD groups after expression of meibomian glands. However, this effect was transient and negligible after the second measurement.
- 1 August 2011
- Published by Wolters Kluwer Health in Cornea
- Vol. 30 (8) , 843-847
Changes in the Evaporation Rate of Tear Film After Digital Expression of Meibomian Glands in Patients With and Without Dry Eye
Purpose: To evaluate the effect of excess meibum on tear evaporation rate in patients with and without dry eye. Methods: Eleven healthy subjects and 16 patients with dry eye were tested. The dry eye group was divided into 2 subgroups: classic keratoconjunctivitis sicca (KCS) with clear and easily expressed meibum and KCS with meibomian gland dysfunction (MGD) with turbid secretions and difficult-to-express meibum. Evaporative measurements were performed at baseline and after digital expression of meibomian glands at 12, 24, 36, and 48 minutes. Two ranges of relative humidity were used, 25% to 35% and 35% to 45%. The data were expressed as microliters per square centimeter per minute. Results: An increase in the evaporation rate of the tear film was noted for all measurements at both relative humidities in the classic KCS and KCS with MGD groups compared with healthy subjects (P < 0.05). The average evaporation rates at relative humidities of 25% to 35% and 35% to 45% were 0.056 ± 0.016 and 0.040 ± 0.008 for the classic KCS group; 0.055 ± 0.026 and 0.037 ± 0.019 for the KCS with MGD group and 0.033 ± 0.012 and 0.023 ± 0.008 for the healthy group. Also, a decrease in the evaporation rate was observed in the healthy and KCS with MGD groups between baseline and the first measurement after digital expression for both relative humidities (P < 0.05). The classic KCS group did not show any changes after expression. Conclusions: Classic KCS and KCS with MGD groups showed an increase in tear evaporation rates compared with the healthy group. Aqueous tear evaporation diminished in the healthy and KCS with MGD groups after expression of meibomian glands. However, this effect was transient and negligible after the second measurement.
- 1 November 2009
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 35 (6) , 297-301
Corneal Thickness Association With Ocular and Corneal High-Order Aberrations
Purpose: To investigate the association among central corneal thickness, peripheral corneal thickness (PCT), and wavefront aberrations in the anterior cornea, posterior cornea and the whole eye in myopia. Methods: Sixty-four eyes of 64 myopic subjects were evaluated with a Pentacam rotating Scheimpflug camera (Oculus, Inc., WA) corneal topographer for: (1) wavefront aberrations from the anterior and posterior corneal surface, (2) corneal thickness (central and peripheral), and (3) with a wavefront aberration-supported cornea ablation wavefront analyzer (Wavescan, Visx, Inc., Santa Clara, CA) for wavefront aberrations generated in the whole eye. Relationships between the wavefront aberrations and corneal thickness were analyzed. Results: The mean age of subjects was 34.75 ± 10.08 years. The central corneal thickness was 550.5 ± 28.459 μm. The mean peripheral thickness was 629.9 ± 32.1 μm. Central and PCTs were not significantly correlated with corneal or ocular high-order aberrations. Intraocular pressure was significantly correlated with ocular trefoil (r = −0.307, P=0.001). Conclusions: Central and PCT were not significantly associated with either anterior or posterior corneal Zernike aberrations; in addition, no association with the whole ocular wavefront aberrations was found.
- 1 November 2009
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 35 (6) , 297-301
Corneal Thickness Association With Ocular and Corneal High-Order Aberrations
Purpose: To investigate the association among central corneal thickness, peripheral corneal thickness (PCT), and wavefront aberrations in the anterior cornea, posterior cornea and the whole eye in myopia. Methods: Sixty-four eyes of 64 myopic subjects were evaluated with a Pentacam rotating Scheimpflug camera (Oculus, Inc., WA) corneal topographer for: (1) wavefront aberrations from the anterior and posterior corneal surface, (2) corneal thickness (central and peripheral), and (3) with a wavefront aberration-supported cornea ablation wavefront analyzer (Wavescan, Visx, Inc., Santa Clara, CA) for wavefront aberrations generated in the whole eye. Relationships between the wavefront aberrations and corneal thickness were analyzed. Results: The mean age of subjects was 34.75 ± 10.08 years. The central corneal thickness was 550.5 ± 28.459 μm. The mean peripheral thickness was 629.9 ± 32.1 μm. Central and PCTs were not significantly correlated with corneal or ocular high-order aberrations. Intraocular pressure was significantly correlated with ocular trefoil (r = −0.307, P=0.001). Conclusions: Central and PCT were not significantly associated with either anterior or posterior corneal Zernike aberrations; in addition, no association with the whole ocular wavefront aberrations was found.
- 1 May 2009
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 35 (3) , 117-119
Assessment and Impact of the Time of Day on Aqueous Tear Evaporation in Normal Subjects
Objectives To determine the impact of the time of day on aqueous tear (AT) evaporation in normal subjects on two consecutive days. Methods In a controlled laboratory setting, morning and afternoon AT evaporation was tested in 19 normal subjects, at the same time of day on two consecutive days. Evaporometry was used at two ranges of relative humidity (RH) 25% to 35% and 35% to 45%. Results Mean AT evaporation rates were 0.069 ± 0.024 for 25% to 35% RH and 0.049 ± 0.018 for 35% to 45% (P = 0.001). There were significant differences for both RH between time of day (P < 0.05) on day 1, but not observed on day 2. Variation between days showed no difference for RH during the afternoon, but there was a difference during the morning (P = 0.042). Conclusions The data are remarkably consistent between study days, but there is more fluctuation during the morning than in the afternoon. Therefore, to further standardize AT evaporation study protocol, we recommend perform evaporometry measurements during the afternoon rather than the morning, because our results showed less variability during the afternoon test between days.
- 1 May 2009
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 35 (3) , 117-119
Assessment and Impact of the Time of Day on Aqueous Tear Evaporation in Normal Subjects
Objectives To determine the impact of the time of day on aqueous tear (AT) evaporation in normal subjects on two consecutive days. Methods In a controlled laboratory setting, morning and afternoon AT evaporation was tested in 19 normal subjects, at the same time of day on two consecutive days. Evaporometry was used at two ranges of relative humidity (RH) 25% to 35% and 35% to 45%. Results Mean AT evaporation rates were 0.069 ± 0.024 for 25% to 35% RH and 0.049 ± 0.018 for 35% to 45% (P = 0.001). There were significant differences for both RH between time of day (P < 0.05) on day 1, but not observed on day 2. Variation between days showed no difference for RH during the afternoon, but there was a difference during the morning (P = 0.042). Conclusions The data are remarkably consistent between study days, but there is more fluctuation during the morning than in the afternoon. Therefore, to further standardize AT evaporation study protocol, we recommend perform evaporometry measurements during the afternoon rather than the morning, because our results showed less variability during the afternoon test between days.
- 1 February 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (2) , 201-209
Ocular Aberrations Measured by the Fourier-based WaveScan and Zernike-based LADARWave Hartmann-Shack Aberrometers
Purpose: To evaluate agreements in lower and higher order aberration measurements by two Hartmann-Shack wavefront-sensing devices. Methods: Using the VISX WaveScan and Alcon LADARWave aberrometers, ocular aberrations at a fixed optical zone of 6 mm were measured on 36 eyes of 18 patients. A tunable light intensity source was used to control pupil size, which was checked using infrared pupillometry. Repeatability of measurements was evaluated using the intra-class correlation coefficient with 3 consecutive measurements on each aberrometer. Results: Mean absolute defocus for WaveScan and LADARWave was 2.82±2.69 and 2.93±3.24 root-mean-square (RMS) µm, whereas astigmatism was 0.81±0.49 and 0.87±0.57 µm, respectively. Pearson correlation coefficients between the two aberrometers were 0.908 and 0.870 for defocus and astigmatism, respectively, whereas higher order aberration correlation was less tight (Pearson correlation coefficient=0.596 for coma, 0.746 for trefoil, 0.836 for spherical aberration, 0.637 for secondary astigmatism, and 0.963 for quadrafoil [ P <.001 for all]). The LADARWave had a tendency to display more spherical aberration than the WaveScan, especially at high aberration values, with mean absolute difference in measurement of 0.12±0.08 µm, and only 44% of eyes having less than ±0.10 RMS µm of difference. The mean total higher order aberration absolute difference was 0.14±0.14 µm, with only 50% of eyes within ±0.1 RMS of agreement. Vector analysis revealed appreciable discrepancies in third- and fourth-order directional Zernike components, while showing similar values for fifth-order components. Intra-class correlation coeffi-cient values for both aberrometers over different aberration orders showed excellent repeatability. Conclusions: The WaveScan and LADARWave share similar lower order aberration measurements, but display significantly different higher order aberration values. [ J Refract Surg . 2009;25:201–209.]
- 1 February 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (2) , 201-209
Ocular Aberrations Measured by the Fourier-based WaveScan and Zernike-based LADARWave Hartmann-Shack Aberrometers
Purpose: To evaluate agreements in lower and higher order aberration measurements by two Hartmann-Shack wavefront-sensing devices. Methods: Using the VISX WaveScan and Alcon LADARWave aberrometers, ocular aberrations at a fixed optical zone of 6 mm were measured on 36 eyes of 18 patients. A tunable light intensity source was used to control pupil size, which was checked using infrared pupillometry. Repeatability of measurements was evaluated using the intra-class correlation coefficient with 3 consecutive measurements on each aberrometer. Results: Mean absolute defocus for WaveScan and LADARWave was 2.82±2.69 and 2.93±3.24 root-mean-square (RMS) µm, whereas astigmatism was 0.81±0.49 and 0.87±0.57 µm, respectively. Pearson correlation coefficients between the two aberrometers were 0.908 and 0.870 for defocus and astigmatism, respectively, whereas higher order aberration correlation was less tight (Pearson correlation coefficient=0.596 for coma, 0.746 for trefoil, 0.836 for spherical aberration, 0.637 for secondary astigmatism, and 0.963 for quadrafoil [ P <.001 for all]). The LADARWave had a tendency to display more spherical aberration than the WaveScan, especially at high aberration values, with mean absolute difference in measurement of 0.12±0.08 µm, and only 44% of eyes having less than ±0.10 RMS µm of difference. The mean total higher order aberration absolute difference was 0.14±0.14 µm, with only 50% of eyes within ±0.1 RMS of agreement. Vector analysis revealed appreciable discrepancies in third- and fourth-order directional Zernike components, while showing similar values for fifth-order components. Intra-class correlation coeffi-cient values for both aberrometers over different aberration orders showed excellent repeatability. Conclusions: The WaveScan and LADARWave share similar lower order aberration measurements, but display significantly different higher order aberration values. [ J Refract Surg . 2009;25:201–209.]
- 1 November 2008
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 34 (6) , 331-334
Impact on Ocular Surface Evaporation of an Artificial Tear Solution Containing Hydroxypropyl Guar
Objective. To determine whether any acute effects on evaporative parameters are produced when using a solution containing Hydroxypropyl (HP) (Systane) versus normal saline solution in the eyes of patients with Keratoconjunctivis Sicca at 30 and 60 minutes postinstillation. Methods. Randomized double-blinded placebo-control 2-period cross-over clinical trial. Twelve patients with a clinical diagnosis of Keratoconjunctivis Sicca were enrolled in this study. Aqueous tear evaporation was measured at baseline, i.e., before the application of drops on the eye, and at 30 and 60 minutes after instillation of one 40 μL drop of either the HP-Guar containing drop or normal saline on two separate days. Statistical analysis included descriptive data analysis and paired t test. Results. Hydroxypropyl-Guar resulted in a decrease in aqueous tear evaporation at 30 minutes postinstillation under 25% to 35% relative humidity (RH) (13.2% reduction, P=0.044) and 35% to 45% RH (10% reduction, P=0.028) conditions. The effect of HP-Guar at 60 minutes postinstillation also decreased aqueous tear evaporation but to a lesser degree. Normal saline solution produced no statistically significant increases and decreases of evaporation. Conclusions. Aqueous tear evaporation contributes significantly to aqueous tear loss and is humidity dependent. An HP-guar containing solution decreased aqueous tear evaporation 30 and 60 minutes after application. The use of topical medication with known antievaporative effect may be beneficial in dry eye therapy. This effect may also be achieved in normal eyes or sub-clinical dry eyes when in low RH environments.
- 1 November 2008
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 34 (6) , 331-334
Impact on Ocular Surface Evaporation of an Artificial Tear Solution Containing Hydroxypropyl Guar
Objective. To determine whether any acute effects on evaporative parameters are produced when using a solution containing Hydroxypropyl (HP) (Systane) versus normal saline solution in the eyes of patients with Keratoconjunctivis Sicca at 30 and 60 minutes postinstillation. Methods. Randomized double-blinded placebo-control 2-period cross-over clinical trial. Twelve patients with a clinical diagnosis of Keratoconjunctivis Sicca were enrolled in this study. Aqueous tear evaporation was measured at baseline, i.e., before the application of drops on the eye, and at 30 and 60 minutes after instillation of one 40 μL drop of either the HP-Guar containing drop or normal saline on two separate days. Statistical analysis included descriptive data analysis and paired t test. Results. Hydroxypropyl-Guar resulted in a decrease in aqueous tear evaporation at 30 minutes postinstillation under 25% to 35% relative humidity (RH) (13.2% reduction, P=0.044) and 35% to 45% RH (10% reduction, P=0.028) conditions. The effect of HP-Guar at 60 minutes postinstillation also decreased aqueous tear evaporation but to a lesser degree. Normal saline solution produced no statistically significant increases and decreases of evaporation. Conclusions. Aqueous tear evaporation contributes significantly to aqueous tear loss and is humidity dependent. An HP-guar containing solution decreased aqueous tear evaporation 30 and 60 minutes after application. The use of topical medication with known antievaporative effect may be beneficial in dry eye therapy. This effect may also be achieved in normal eyes or sub-clinical dry eyes when in low RH environments.
- 1 June 2008
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 24 (6) , 619-625
Contrast Sensitivity and Higher Order Aberrations in Eyes Implanted With AcrySof IQ SN60WF and AcrySof SN60AT Intraocular Lenses
Purpose: To evaluate the efficacy of the aspheric optic of the AcrySof IQ SN60WF intraocular lens (IOL) in decreasing spherical and total higher order aberrations and improving contrast sensitivity after cataract surgery compared to the spheric AcrySof SN60AT. Methods: Fifty-two eyes of 36 patients were evaluated at the University of Texas Southwestern Medical Center at Dallas 3 to 6 months after phacoemulsification with implantation of the AcrySof IQ SN60WF (27 eyes) or AcrySof SN60AT (25 eyes) IOL. Eyes with previous surgery or ocular pathology were excluded. Results: Eyes implanted with the AcrySof IQ SN60WF had less total higher order and spherical aberrations than AcrySof SN60AT-implanted eyes at pupils of 4 mm (0.14±60.06 vs 0.18±0.04 µ m and −0.01±0.03 vs 0.09±0.03 µ m, respectively), 5 mm (0.24±0.07 vs 0.34±0.08 µ m and 0.03±0.02 vs 0.23±0.08 µ m, respectively), and 6 mm (0.42±0.13 vs 0.67±0.12 µ m and 0.08±0.04 and 0.46±0.09 µ m, respectively), ( P <.05 for all), with similar mean coma, trefoil, and 5th order aberrations. AcrySof SN60WF eyes showed better contrast sensitivity than AcrySof SN60AT eyes at 12 and 18 cycles per degree (cpd) under mesopic conditions (1.65±0.23 vs 1.51±0.25 and 1.22±0.21 vs 1.01±0.19, respectively), and at 18 cpd under glare (1.12±0.30 vs 0.87±0.31, respectively) ( P <.05). Photopic contrast sensitivity was similar in both groups. The two groups had comparable mean age, axial length, IOL power, and postoperative mesopic and photopic pupil sizes. Conclusions: Compared to a spheric optic, the aspheric design of the AcrySof IQ SN60WF reduces spherical aberration, especially under larger pupil sizes, and improves mesopic contrast sensitivity at higher frequencies with and without glare. [ J Refract Surg. 2008;24:619–625.]
- 1 June 2008
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 24 (6) , 619-625
Contrast Sensitivity and Higher Order Aberrations in Eyes Implanted With AcrySof IQ SN60WF and AcrySof SN60AT Intraocular Lenses
Purpose: To evaluate the efficacy of the aspheric optic of the AcrySof IQ SN60WF intraocular lens (IOL) in decreasing spherical and total higher order aberrations and improving contrast sensitivity after cataract surgery compared to the spheric AcrySof SN60AT. Methods: Fifty-two eyes of 36 patients were evaluated at the University of Texas Southwestern Medical Center at Dallas 3 to 6 months after phacoemulsification with implantation of the AcrySof IQ SN60WF (27 eyes) or AcrySof SN60AT (25 eyes) IOL. Eyes with previous surgery or ocular pathology were excluded. Results: Eyes implanted with the AcrySof IQ SN60WF had less total higher order and spherical aberrations than AcrySof SN60AT-implanted eyes at pupils of 4 mm (0.14±60.06 vs 0.18±0.04 µ m and −0.01±0.03 vs 0.09±0.03 µ m, respectively), 5 mm (0.24±0.07 vs 0.34±0.08 µ m and 0.03±0.02 vs 0.23±0.08 µ m, respectively), and 6 mm (0.42±0.13 vs 0.67±0.12 µ m and 0.08±0.04 and 0.46±0.09 µ m, respectively), ( P <.05 for all), with similar mean coma, trefoil, and 5th order aberrations. AcrySof SN60WF eyes showed better contrast sensitivity than AcrySof SN60AT eyes at 12 and 18 cycles per degree (cpd) under mesopic conditions (1.65±0.23 vs 1.51±0.25 and 1.22±0.21 vs 1.01±0.19, respectively), and at 18 cpd under glare (1.12±0.30 vs 0.87±0.31, respectively) ( P <.05). Photopic contrast sensitivity was similar in both groups. The two groups had comparable mean age, axial length, IOL power, and postoperative mesopic and photopic pupil sizes. Conclusions: Compared to a spheric optic, the aspheric design of the AcrySof IQ SN60WF reduces spherical aberration, especially under larger pupil sizes, and improves mesopic contrast sensitivity at higher frequencies with and without glare. [ J Refract Surg. 2008;24:619–625.]
- 1 July 2007
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 33 (4) , 177-179
Pattern of Vital Staining and Its Correlation With Aqueous Tear Deficiency and Meibomian Gland Dropout
Purpose. To assess the relationship between the degree and anatomic location of ocular surface vital staining and the degree of aqueous tear deficiency in patients with dry eye, as measured by the Schirmer test, and the presence of meibomian gland dropout. Methods. Twenty-two patients with dry eye (nine men and 13 women; mean age, 60 years) were prospectively enrolled in the study. Eleven subjects with no ocular disease were considered control subjects. Lissamine green vital staining, Schirmer test, and meibomian gland dropout were evaluated. Results. Patients were stratified based on their vital staining pattern (presence or absence of corneal staining). A progressive decrease in the Schirmer test result was found when the vital staining score increased (r = –0.655; PP≤0.001). Conclusions. The presence of corneal vital staining correlates with a more severe dry eye as shown by the Schirmer test. Patients with dry eye have an increased meibomian gland dropout. The degree and pattern of vital staining correlate with the severity of dry eye.
- 1 July 2007
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 33 (4) , 177-179
Pattern of Vital Staining and Its Correlation With Aqueous Tear Deficiency and Meibomian Gland Dropout
Purpose. To assess the relationship between the degree and anatomic location of ocular surface vital staining and the degree of aqueous tear deficiency in patients with dry eye, as measured by the Schirmer test, and the presence of meibomian gland dropout. Methods. Twenty-two patients with dry eye (nine men and 13 women; mean age, 60 years) were prospectively enrolled in the study. Eleven subjects with no ocular disease were considered control subjects. Lissamine green vital staining, Schirmer test, and meibomian gland dropout were evaluated. Results. Patients were stratified based on their vital staining pattern (presence or absence of corneal staining). A progressive decrease in the Schirmer test result was found when the vital staining score increased (r = –0.655; PP≤0.001). Conclusions. The presence of corneal vital staining correlates with a more severe dry eye as shown by the Schirmer test. Patients with dry eye have an increased meibomian gland dropout. The degree and pattern of vital staining correlate with the severity of dry eye.
- 1 June 2006
- Published by Elsevier in Ophthalmology
- Vol. 113 (6) , 955-959
Fourth-Generation Fluoroquinolone Penetration into the Aqueous Humor in Humans
- 1 June 2006
- Published by Elsevier in Ophthalmology
- Vol. 113 (6) , 955-959
Fourth-Generation Fluoroquinolone Penetration into the Aqueous Humor in Humans