LCLarry A. Chinitz

Larry A. Chinitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Larry A. Chinitz has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Right‐Sided Implantation and Subpectoral Position are Predisposing Factors for Fracture of a 6.6 French ICD Lead

    by Neil E. Bernstein, Edmund T. Karam, Anthony Aizer, Brian C. Wong, Douglas S. Holmes, Scott A. Bernstein, Larry A. Chinitz

    Background: The Medtronic Sprint Fidelis (Medtronic Inc., Minneapolis, MN, USA) lead family is associated with an unacceptable incidence of premature lead failure. There are limited data on risk factors for lead fracture. We hypothesized that factors leading to potential increased forces on the lead related to device implantation or technique may be associated with premature lead failure. Methods: We reviewed the implant data from our group and identified 176 patients who received active fixation Medtronic Fidelis (Model 6931, single coil and Model 6949, dual coil) leads. Implant data, including age, sex, venous access site, implant side, implant location, and number of venous leads were reviewed. Hospital, pacemaker clinic, and Medtronic registration databases were reviewed for evidence of lead failure, replacement, or abandonment. Data was evaluated in univariate and multivariate regression analyses. Results: Of the 176 leads implanted, 10 (5.7%) were noted to develop malfunction. This presented as inappropriate shocks from sensed noise or elevated impedance measurements. Of the above noted implant features, only right‐sided (vs left‐sided) implant (hazard ratio [HR] 18.8, 95% confidence intervals [CI] 3.8, 93.3), and subpectoral implant (vs prepectoral; HR 14.31, 95% CI 3.2, 64.0) were predictive of lead failure in maximally adjusted models. Conclusions: We have identified both right‐sided implantation and subpectoral generator positioning as factors associated with premature lead malfunction in Fidelis active fixation leads. Clinical decisions regarding patient management should incorporate these findings in regard to lead replacement in high‐risk patients. (PACE 2012; 35:659–664)


  • Contact Sensing Provides a Highly Accurate Means to Titrate Radiofrequency Ablation Lesion Depth

    by Douglas Holmes, Jeffrey M. Fish, Israel A. Byrd, Jeremy D. Dando, Steven J. Fowler, Hong Cao, James A. Jensen, Harry A. Puryear, Larry A. Chinitz


  • Cardiac Vein Angioplasty for Biventricular Pacing

    by David A. Sandler, David Y. Feigenblum, Neil E. Bernstein, Douglas S. Holmes, Larry A. Chinitz

    SANDLER, D.A., et al.; Cardiac Vein Angioplasty for Biventricular Pacing. Biventricular pacing for the treatment of congestive heart failure has consistently demonstrated improvement in quality‐of‐life and reduction in heart failure symptoms. Though the over‐the‐wire systems will be helpful in overcoming many existing obstacles to optimal lead placement, anatomic variability will still limit overall success. Cardiac vein angioplasty may be required for deployment of leads into tortuous or obstructed cardiac veins. This case report describes the angioplasty of a focal cardiac vein stenosis allowing for successful implantation of a left ventricular pacing lead. The safety of this procedure is unknown, though the risks may be acceptable in certain patients.