  • Digital holography microscopy (DHM) operating in pulsed stroboscopic mode: a versatile metrology instrument for micro and nano technology

    by Frédéric Montfort, François Marquet, Etienne Cuche, Nicolas Aspert, Eduardo Solanas, Yves Emery, Christian Depeursinge

    Process engineering and failure analysis of MEMS and MOEMS require static and dynamical characterization of both their in-plane and out of plane response to an excitation. A remarkable characteristic of Digital Holography Microscopes (DHM) is the extremely short acquisition time required to grab the whole information necessary to provide 3D optical topography of the sample: a unique frame grab, without any vertical or lateral scan provides the information over the full field of view. First, it ensures DHM measurements to be insensitive to vibrations. Second, it opens the door to fast dynamical characterization of micro-systems. For periodic movement analysis, DHM can operate in two stroboscopic modes with standard cameras. The first one enables precise characterization up to excitation frequencies of 100 kHz with recovery cycle of 10% simply by triggering properly the camera. The second one uses a pulsed source for investigation of higher excitation frequencies. For non periodic movement analysis fast acquisition cameras and postponed treatment are used. DHM are therefore unique and very efficient tool for dynamical characterization of in‐plane and out-of-plane response. In this paper we illustrate the two stroboscopic modes with an example of a high frequency micro mirror.


  • Submicrometer optical tomography by multiple-wavelength digital holographic microscopy

    by Frédéric Montfort, Tristan Colomb, Florian Charrière, Jonas Kühn, Pierre Marquet, Etienne Cuche, Sylvain Herminjard, Christian Depeursinge

    We present a method for submicrometer tomographic imaging using multiple wavelengths in digital holographic microscopy. This method is based on the recording, at different wavelengths equally separated in the k domain, in off-axis geometry, of the interference between a reference wave and an object wave reflected by a microscopic specimen and magnified by a microscope objective. A CCD camera records the holograms consecutively, which are then numerically reconstructed following the convolution formulation to obtain each corresponding complex object wavefront. Their relative phases are adjusted to be equal in a given plane of interest and the resulting complex wavefronts are summed. The result of this operation is a constructive addition of complex waves in the selected plane and destructive addition in the others. Tomography is thus obtained by the attenuation of the amplitude out of the plane of interest. Numerical variation of the plane of interest enables one to scan the object in depth. For the presented simulations and experiments, 20 wavelengths are used in the 480–700  nm range. The result is a sectioning of the object in slices 725  nm thick.


  • Purely numerical compensation for microscope objective phase curvature in digital holographic microscopy: influence of digital phase mask position

    by Frédéric Montfort, Florian Charrière, Tristan Colomb, Etienne Cuche, Pierre Marquet, Christian Depeursinge

    Introducing a microscope objective in an interferometric setup induces a phase curvature on the resulting wavefront. In digital holography, the compensation of this curvature is often done by introducing an identical curvature in the reference arm and the hologram is then processed using a plane wave in the reconstruction. This physical compensation can be avoided, and several numerical methods exist to retrieve phase contrast images in which the microscope curvature is compensated. Usually, a digital array of complex numbers is introduced in the reconstruction process to perform this curvature correction. Different corrections are discussed in terms of their influence on the reconstructed image size and location in space. The results are presented according to two different expressions of the Fresnel transform, the single Fourier transform and convolution approaches, used to propagate the reconstructed wavefront from the hologram plane to the final image plane.


  • Shot noise perturbations in digital holographic microscopy phase images

    by Florian Charrière, Frederic Montfort, Etienne Cuche, Christian D. Depeursinge

    In digital holographic microscopy, shot noise is an intrinsic part of the recording process with a digital camera. We present a study based on simulations describing how shot noise influences the quality of the reconstructed phase images under different beams intensities configurations. A model for image quality estimation based on the decision statistical theory proposed by Wagner and Brown (R.F. Wagner and D.G. Brown, "Unified SNR Analysis of Medical Imaging-Systems," Phys. Med. Biol. 30, 489-518 (1985)) will be presented. A simulation will depict the variations of the reconstructed phase images SNR for different distributions of the total intensity between the reference and the object beam.


  • Measurements of corner cubes microstructures by high-magnification digital holographic microscopy

    by Jonas Kühn, Etienne Cuche, Yves Emery, Tristan Colomb, Florian Charrière, Frédéric Montfort, Mikhail Botkine, Nicolas Aspert, Christian Depeursinge

    This paper presents Digital Holographic Microscopy (DHM) quantitative measurements of transparent high aspect-ratio microstructures. Our experiment was performed using a digital holographic microscope in transmission configuration with a 60x magnification 1.3 NA oil immersion microscope objective, with a diode laser source at 664 nm. We used a calculation model based on the use of two immersion liquids for the experiment, the first one to resolve the phase jumps by using a refractive index liquid close to the sample index, in combination with a second one to retrieve the sample topology from the optical path length information. Such a model makes absolute topographic measurements of high aspect ratio transparent samples achievable by DHM. The model is then applied to measure 25 and 50 m transparent micro-corner cubes arrays, which exhibit up to 1:1,4 aspect ratio with theoretical slopes up to about 55 degrees. Thanks to our phase measurement precision down to 1°, we found possible to measure accurately the slopes of each face of the microstructures under investigation, and this with a good theoretical agreement.


  • Tomography using multiple wavelengths in digital holography: method, simulations, and experiments

    by Frédéric Montfort, Florian Charrière, Tristan Colomb, Jonas Kuehn, Etienne Cuche, Christian Depeursinge

    In this paper we present a method for tomographic imaging using multiple wavelengths in digital holographic microscopy. This method is based on the recording at different wavelengths equally separated in the k-domain, in off-axis geometry, of the interference between a reference wave and an object wave reflected by a microscopic sample and magnified by a microscope objective. A couple charged device (CCD) camera records consecutively the resulting holograms, which are then numerically reconstructed to obtain their resulting wavefront. Those wavefronts are then summed. The result of this operation is a constructive addition of complex waves in the selected plane and destructive addition in the others. Varying the plane of interest enables the scan the object in depth. For the presented simulations and experiments, twenty wavelengths are used in the 480-700 nm range. An object consisting of irregularly stairs with heights of 375, 525, 975, 1200 and 1275 nm is reconstructed. Its lateral dimensions are 250 × 250 microns. The results show clearly a 3D imaging technique with axial resolution under the micron.


  • Digital holography microscopy (DHM): fast and robust systems for industrial inspection with interferometer resolution

    by Yves Emery, Etienne Cuche, Francois Marquet, Nicolas Aspert, Pierre Marquet, Jonas Kuhn, Mikhail Botkine, Tristan Colomb, Frederic Montfort, Florian Charriere, et al.

    With the recent technological advances, there is an increasing need for measurement systems providing interferometer resolution for inspection of large quantities of individual samples in manufacturing environments.. Such applications require high measurement rates, robustness, ease of use, and non-contact systems. We show here that Digital Holographic Microscopy (DHM), a new method that implements digitally the principle of holography, is particularly well suited for such industrial applications. With the present computers power and the developments of digital cameras, holograms can be numerically interpreted within a tenth of second to provide simultaneously: the phase information, which reveals object surface with vertical resolution at the nanometer scale along the optical axis, and intensity images, as obtained by conventional optical microscope. The strength of DHM lies in particular on the use of the so-called off-axis configuration, which enables to capture the whole information by a single image acquisition, i.e. typically during a few ten of microseconds. These extremely short acquisition times make DHM systems insensitive to vibrations. These instruments can operate without vibration insulation means, making them a cost effective solution not only for R&D, but also especially for an implementation on production lines. Numerous application examples are presented in this paper such as shape and surface characterization of high aspect ratio micro-optics, surface nanostructures, and surface roughness.


  • Digital Holographic Microscopy for Study Cellular Dynamics

    by Pierre M. Marquet, Benjamin Rappaz, Pierre J. Magistretti, Etienne Cuche, Yves Emery, Tristan Colomb, Frédéric Montfort, Florian Charrière, Marian Anca, Christian Depeursinge

    Based on an original numerical reconstruction algorithm (E. Cuche et al. Appl. Opt. 38, 6994 1999), we have developed a Digital Holographic Microscope (DHM), in a transmission mode, allowing to investigate cellular structures and dynamics.

  • Digital holographic microscopy applied to metrology

    by Christian D. Depeursinge, Florian Charriere, Anca M. Marian, Frederic Montfort, Tristan Colomb, Jonas Kuhn, Etienne Cuche, Yves Emery, Pierre Marquet, Pierre J. Magistretti

    We report on a method called Digital Holographic Microscopy (DHM) for the numerical reconstruction of digital holograms taken with a microscope. It allows for simultaneous amplitude and quantitative phase contrast imaging. The reconstruction method computes the propagation of the complex optical wavefront diffracted by the object and is used to determine the refractive index and/or shape of the object with an accuracy in the nanometer range along the optical axis. A single hologram is needed for reconstruction. The method requires the adjustment of several reconstruction parameters. The adjustment is performed automatically by using a suitable algorithm. The method has been applied to the measurement of several integrated optics devices, MOEMS, and integrated micro-optical components: microlenses.