MTMarc Thomsen

Marc Thomsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marc Thomsen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fixierte hintere Subluxations- und Außenrotationsfehlstellung des Kniegelenks bei angeborener Patellaluxation und Aplasie des hinteren Kreuzbandes

    by B. G. Ochs, N. Schmelzer-Schmied, C. Carstens, M. Thomsen

    Die kongenitale Patellaluxation ist eine sehr seltene Anomalie. Hierbei steht die Patella seitlich der lateralen Femurkondyle und ist manuell nicht reponierbar. Die Diagnose wird oftmals erst durch einen verzögerten Laufbeginn oder durch ein verändertes Gangbild gestellt. Vorgestellt wird der Fall eines Mädchens mit einer fixierten hinteren Subluxations- und Außenrotationsfehlstellung eines Kniegelenks aufgrund einer angeborenen Patellaluxation und einer gleichzeitigen Aplasie des hinteren Kreuzbandes (HKB), bei der die komplexe Fehlstellung des Kniegelenks stufenweise korrigiert wurde. Hierfür erfolgte zum einen die akute offene Rezentrierung der Patella und zum anderen die schrittweise Distraktion der verkürzten ischiokruralen Muskulatur und der hinteren Kapsel-Band-Strukturen. Unseres Wissens nach handelt es sich hier um die erstmalige Beschreibung einer angeborenen Patellaluxation kombiniert mit einer Aplasie des HKB. Congenital dislocation of the patella is very rare. In this anomaly, the patella is dislocated to the side of the lateral femoral condylus and cannot be repositioned manually. Diagnosis is often made by clinical examination and observation of an abnormal gait. We describe the long-term course of treatment in a young girl with fixed posterior subluxation with lateral rotation of the knee joint caused by congenital dislocation of the patella in combination with aplasia of the posterior cruciate ligament. These anomalies of the knee joint were corrected incrementally. First, recentralisation of the patella was performed by open surgery. Subsequently, distraction of the shortened ischiocrural muscles and the posterior capsules and ligaments was conducted. This is the first case to be described, to the best of our knowledge, of a patient with congenital dislocation of the patella in combination with aplasia of the posterior cruciate ligament. We describe the successful treatment of such a fixed posterior subluxation and lateral rotation of the knee joint.


  • Posttraumatische Schulterinstabilit t im Wachstumsalter

    by B. G. Ochs, M. Rickert, N. Schmelzer-Schmied, M. Loew, M. Thomsen

    Traumatische Schulterluxationen im Wachstumsalter sind ein seltenes Ereignis. Ein hoher Anteil der Jugendlichen entwickelt im weiteren Verlauf eine rezidivierende unidirektionale Schulterinstabilität.


  • Von Abrieb, Korrosion und Reibung...

    by M. Thomsen, V. Ewerbeck

  • Polyethylen als Implantatwerkstoff

    by R.M. Streicher, M. Thomsen

    UHMW-Polyethylen ist seit Anfang der 60er Jahre eines der meistverwendeten Materialien in der Gelenkersatzchirurgie, das mit großem Erfolg eingesetzt wird. Im Laufe des klinischen Einsatzes traten jedoch auch Schwachstellen dieses Werkstoffs zutage, so etwa der relativ hohe Verschleiß und die Alterung. Als Folge umfangreicher Forschungsarbeiten an diesem Polymer wurden zahlreiche Verbesserungen in der Qualität des Ausgangsmaterials, der Verarbeitung und der Sterilisation eingeführt. Diese Verbesserungen, gepaart mit Erkenntnissen über das viskoelastische Verhalten von ultrahochmolekularem Polyethylen (UHMWPE), haben zu verbesserten werkstoffgerechten Designs von Implantatkomponenten geführt,welche sich in der klinischen Praxis bewährt haben. In den 90er Jahren wurde die gezielte Beeinflussung der molekularen Struktur durch Bestrahlung zur Verbesserung der Eigenschaften von UHMWPE eingehender untersucht. Während die Strahlensterilisation in Luft zur Reduktion des für das tribologische Verhalten wichtigen Molekulargewichts durch Oxidation und einer beschleunigten und verstärkten Alterung dieses Werkstoffs führt, können durch die Anwendung einer Stickstoffatmosphäre während der Bestrahlung und der Lagerung die positiven Effekte der Strahlensterilisation vorteilhaft zur Vernetzung von Polyethylen verwendet werden. Dieser Effekt kann durch erhöhte Bestrahlungsdosis deutlich erhöht werden. Derart hochvernetzte (highly cross linked) Polyethylene zeigen im Labor eine extreme Reduktion der Abriebwerte. Gleichzeitig werden aber die mechanischen Eigenschaften modifiziert. Erste Beobachtungen über Rissbildungen (Werkstoffermüdung) einer speziellen hochvernetzten Version solcher XLPE-Explantate zeigen einmal mehr, dass nur klinische Langzeituntersuchungen eine abschließende Beurteilung dieser Polyethylene ermöglichen. Since the early 1960s, ultrahigh-molecularweight polyethylene (UHMWPE) has been one of the most frequently and successfully used materials in total joint replacement. However, in the course of clinical usage, various weaknesses of the material became apparent including wear and aging properties. As a result of research on this polymer, several improvements in the quality of the raw material, the processing, and the sterilization have been introduced.These changes paired with an improved knowledge of the viscoelastic behavior of UHMWPE have led to an improved design of the components to meet the requirements of the given material characteristics and in turn to better clinical results. In the 1990s, investigations focused on the influence of radiation on the molecular structures of polyethylene.Gamma radiation treatment in air leads to an important decrease in the molecular weight with reduced tribological behavior and accelerated aging. In contrast, a nitrogen atmosphere during irradiation and storage can improve the linkage of the polyethylene and promote the positive effects of radiation treatment.This effect can be further intensified by increased radiation levels.Such highly cross-linked polyethylenes demonstrate extremely low wear rates in vitro;however, other material properties are also changed.First reports on fissures in highly cross-linked polyethylene explants demonstrate that only long-term clinical trials can allow a final verdict on the clinical potential of highly cross-linked polyethylenes.


  • Entwicklungen in der Hemi-Hüftarthroplastik und die Theorie des überschlagenen dimeren Kugelgelenks

    by M. Thomsen, S. J. Breusch, U. Schneider, D. Kubein-Meesenburg, H. Nägerl

    In der Arbeit wird die Entwicklung der Hemiarthroplastik von der monozentrischen Kopfprothese zur bizentrischen Duokopfprothese nachgezeichnet. Eine empirische Entwicklung, die sich an den klinischen (Miss-) Erfolgen orientierte. Mit Hilfe des 1990 von Nägerl beschriebenen Konzeptes des überschlagenen dimeren Kugelgelenks, wird der Mechanismus von 19 Duokopfprothesen physikalisch analysiert und erklärt. Klinische, in der Literatur angegebene Beobachtungen über das varische Einstellen und die Luxationen der monozentrischen Bipolarköpfe werden in diesem physikalisch, biomechanischen Kontext ebenso diskutiert und aufgelöst, wie die Valguspositionierung und das “selbstzentrierende, intelligente” Moment der bizentrischen Bipolarprothesen. Die Hemiarthroplastik hat über die Methode Versuch und Irrtum im exzentrischen Duokopf das Prinzip des überschlagenen dimeren Kugelgelenks bzw. der überschlagenen dimeren Gelenkkette evolutioniert. Nach diesem Prinzip funktionieren heute elf der sechzehn auf dem Markt verbliebenen untersuchten Systeme. Aim of the study was to analyze the developments of hemiarthroplasties from the femur prosthesis to the bicentric bipolar prosthesis of today. Using the theories published 1990 by Nägerl about “dimeric link chains”, nineteen bipolar-head systems were analyzed and biomechanically explained. Clinical findings, such as the problems of luxation and varus positioning of the monocentric bipolars, as well as the valgus, “self-centric” positioning of the bicentric prosthesis are discussed and explaned correctly by physics. The hemiarthoplasty with the bicentric bipolar system of today has realized the principles of the dimeric link chains and is superior concept. Eleven of the sixteen today available systems work like this concept which was reached by try and error. The function of a bicentric system is solved now and explained by physics.


  • Kinematics and biomechanics of the elbow

    by M. Thomsen, M. Loew, H. Nägerl


  • Results of Kyphectomy with the Technique of Warner and Fackler in Children with Myelodysplasia

    by Marc Thomsen, Claus Carstens

    Summary: Pathological lumbar kyphosis occurs in approximately 8% to 20% of patients with myelomeningocele. During the past 4 years, nine patients with an average preoperative kyphosis of 152° were surgically corrected. They had a short fusion and a long stabilization with Luque rod instrumentation using a technique described by Warner and Fackler (1993). The average degree of correction was 104° and, on average, 2.5 vertebrae were resected. The average surgical time was 225 minutes, and blood loss averaged 635 ml. We saw two complications: one penetration of the distal part of the rod through the sacrum after 32 months, and a dislocation of the rods out of the first sacral foramen after 33 months. From our experience, this procedure is highly demanding, but effective. It should be limited to patients below the weight of 30 kg. Address correspondence and reprint requests to Dr Marc Thomsen, Stiftung Orthopädische Universitätsklinik, Schlierbacher Landstraβe 200a, D-69118 Heidelberg, Germany. Copyright © 2000 Wolters Kluwer Health, Inc. All rights reserved.