Renata Jasionowska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Renata Jasionowska has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Francesca Buiarelli
Department of Chemistry, “Sapienza” University of Rome, P.le Aldo Moro, 5, 00185 Rome, Italy
3 shared publications Franco Coccioli
Department of Chemistry, University “La Sapienza”, Rome, Italy
3 shared publicationsAlessandro Terracciano
Department of Chemistry, University “La Sapienza”, Rome, Italy
1 shared publicationGiampaolo Cartoni
Dipartimento di Chimica, Università “La Sapienza”, P. le A. Moro 5, 00185 Roma, Italy; Fax: +39 06 490631
1 shared publication- Mario Vincenzo Russo
Department of Agriculture, Environmental and Food Sciences, University of Molise, via De Sanctis, I-86100 Campobasso, Italy
1 shared publication Sonia di Berardino
Dipartimento di Chimica, Università “La Sapienza”, P. le A. Moro 5, 00185 Roma, Italy
1 shared publication
Latest Publications
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3519-3523
Development and validation of an MEKC method for determination of nitrogen‐containing drugs in pharmaceutical preparations
A fast and accurate micellar electrokinetic capillary chromatography method was developed for quality control of pharmaceutical preparations containing cold remedies as acetaminophen, salicylamide, caffeine, phenylephrine, pseudoephedrine, norephedrine and chlorpheniramine. The method optimization was realized on a Beckman P/ACE System MDQ instrument. The baseline separation of seven analytes was performed in an uncoated fused silica capillary internal diameter (ID)=50 µm using tris‐borate (20 mM, pH=8.5) containing sodium dodecyl sulphate 30 mM BGE. On line‐UV detection at 214 nm was performed and the applied voltage was 10 kV. The operating temperature was 25°C. After experimental conditions optimization, the proposed method was validated. The evaluated parameters were: precision of migration time and of corrected peak area ratio, linearity range, limit of detection, limit of quantification, accuracy (recovery), ruggedness and applicability. The method was then successfully applied for the analysis of three pharmaceutical preparations containing some of the analytes listed before.
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3519-3523
Development and validation of an MEKC method for determination of nitrogen‐containing drugs in pharmaceutical preparations
A fast and accurate micellar electrokinetic capillary chromatography method was developed for quality control of pharmaceutical preparations containing cold remedies as acetaminophen, salicylamide, caffeine, phenylephrine, pseudoephedrine, norephedrine and chlorpheniramine. The method optimization was realized on a Beckman P/ACE System MDQ instrument. The baseline separation of seven analytes was performed in an uncoated fused silica capillary internal diameter (ID)=50 µm using tris‐borate (20 mM, pH=8.5) containing sodium dodecyl sulphate 30 mM BGE. On line‐UV detection at 214 nm was performed and the applied voltage was 10 kV. The operating temperature was 25°C. After experimental conditions optimization, the proposed method was validated. The evaluated parameters were: precision of migration time and of corrected peak area ratio, linearity range, limit of detection, limit of quantification, accuracy (recovery), ruggedness and applicability. The method was then successfully applied for the analysis of three pharmaceutical preparations containing some of the analytes listed before.
- 9 September 2004
- Published by Wiley in Annali di Chimica
- Vol. 94 (9-10) , 699-706
Determination of Phenolic Acids in Olive Oil by Capillary Electrophoresis
A CZE method for the separation and quantitation of phenolic acids (cinnamic, syringic, p—coumaric, vanillic, caffeic, 3, 4—dihydroxyphenylacetic, protocatechuic), extracted from extra virgin olive oil, was developed. The sample preparation involved the LLE and SPE extraction methods. CE separation was performed in a fused silica capillary of I. D. = 50μm using as a BGE 40 mM borate buffer at pH = 9.2. The separation voltage was 18kV with corresponding current of 2728 μA. Detection was accomplished with UV—detector at λ = 200nm. The proposed method was fully validated. A good repeatability of migration time (RSD% ranged from 0.81 to 1.63) and of corrected peak area ( RSD% from 2.89 to 5.77) was obtained. The linearity of detector response in the range from 5 to 50 ppm was checked, obtaining the correlation coefficient R2 values in the range: 0.9919—0.9997. Some phenolic acids in real oil samples were detected and quantified with the proposed method.
- 9 September 2004
- Published by Wiley in Annali di Chimica
- Vol. 94 (9-10) , 699-706
Determination of Phenolic Acids in Olive Oil by Capillary Electrophoresis
A CZE method for the separation and quantitation of phenolic acids (cinnamic, syringic, p—coumaric, vanillic, caffeic, 3, 4—dihydroxyphenylacetic, protocatechuic), extracted from extra virgin olive oil, was developed. The sample preparation involved the LLE and SPE extraction methods. CE separation was performed in a fused silica capillary of I. D. = 50μm using as a BGE 40 mM borate buffer at pH = 9.2. The separation voltage was 18kV with corresponding current of 2728 μA. Detection was accomplished with UV—detector at λ = 200nm. The proposed method was fully validated. A good repeatability of migration time (RSD% ranged from 0.81 to 1.63) and of corrected peak area ( RSD% from 2.89 to 5.77) was obtained. The linearity of detector response in the range from 5 to 50 ppm was checked, obtaining the correlation coefficient R2 values in the range: 0.9919—0.9997. Some phenolic acids in real oil samples were detected and quantified with the proposed method.
- 2 April 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (5) , 425-428
Capillary Zone Electrophoresis of some organic acids in milk whey
This paper describes a method for analysing some acids of milk whey by Capillary Zone Electrophoresis. After eliminating the whey proteins by ultrafiltration, the whey underwent electrophoretic separation in the presence of anodic electroosmotic flow. The following analytes were detected: citric, orotic, uric, and hippuric acids. A procedure is described for sample preparation and the operating conditions for electrophoretic capillary separation established. Finally, orotic acid is quantitatively determined.
- 2 April 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (5) , 425-428
Capillary Zone Electrophoresis of some organic acids in milk whey
This paper describes a method for analysing some acids of milk whey by Capillary Zone Electrophoresis. After eliminating the whey proteins by ultrafiltration, the whey underwent electrophoretic separation in the presence of anodic electroosmotic flow. The following analytes were detected: citric, orotic, uric, and hippuric acids. A procedure is described for sample preparation and the operating conditions for electrophoretic capillary separation established. Finally, orotic acid is quantitatively determined.