Gösta Granström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gösta Granström has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Anders Tjellström
Associate professor, ENT‐Clinic, Sahlgrenska University Hospital, Gothenburg, Sweden
5 shared publicationsHans-Göran Gröndahl
2 shared publicationsCatharina Jacobsson
1 shared publicationJörgen Holmquist
From the Department of Otolaryngology-Head and Neck Surgery, Göteborg University, Gothenburg, Sweden
1 shared publicationKerstin Bergström
Department of Otolaryngology Head and Neck Surgery Göteborg University Gothenburg Sweden
1 shared publicationMarie Odersjö
Department of Otolaryngology Head and Neck Surgery Göteborg University Gothenburg Sweden
1 shared publication
Latest Publications
- 1 February 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (2) , 199-203
Imaging of Osseointegrated Implants in the Temporal Bone by Accuitomo 3-Dimensional Cone Beam Computed Tomography
Follow-ups of osseointegrated implants in the temporal bone have been limited to clinical stability and resonance frequency measurements. Standard computed tomographic scanning is restricted because of the high radiation doses to the brain and the presence of disturbing metal artifacts. The present study was undertaken to evaluate the use of cone beam computed tomography preoperatively and postoperatively. Prospective investigation of patients intended for implant surgery and patients participating in a follow-up protocol. Tertiary referral center. Patients with osseointegrated implants and patients intended for implants in the temporal bone for bone-anchored epistheses and bone conduction hearing devices were investigated by a 3-D Accuitomo cone beam computed tomography machine. Images in sagittal, coronal, and axial planes were obtained and analyzed in a personal computer. Preoperative and postoperative views were analyzed regarding implant integration, bone resorption, anatomic landmarks, and implant failure. Eighteen patients were included in the study. With the used technique, it was easy to detect air cells, the sigmoid sinus, and posterior fossa and to recommend an ideal implant installation site. Bone resorption, bone overgrowth, and implant connex to air cells and dura were easy to detect. Accuitomo cone beam tomography showed to be a reliable method for investigating osseointegrated implants in the temporal bone.
- 1 February 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (2) , 199-203
Imaging of Osseointegrated Implants in the Temporal Bone by Accuitomo 3-Dimensional Cone Beam Computed Tomography
Follow-ups of osseointegrated implants in the temporal bone have been limited to clinical stability and resonance frequency measurements. Standard computed tomographic scanning is restricted because of the high radiation doses to the brain and the presence of disturbing metal artifacts. The present study was undertaken to evaluate the use of cone beam computed tomography preoperatively and postoperatively. Prospective investigation of patients intended for implant surgery and patients participating in a follow-up protocol. Tertiary referral center. Patients with osseointegrated implants and patients intended for implants in the temporal bone for bone-anchored epistheses and bone conduction hearing devices were investigated by a 3-D Accuitomo cone beam computed tomography machine. Images in sagittal, coronal, and axial planes were obtained and analyzed in a personal computer. Preoperative and postoperative views were analyzed regarding implant integration, bone resorption, anatomic landmarks, and implant failure. Eighteen patients were included in the study. With the used technique, it was easy to detect air cells, the sigmoid sinus, and posterior fossa and to recommend an ideal implant installation site. Bone resorption, bone overgrowth, and implant connex to air cells and dura were easy to detect. Accuitomo cone beam tomography showed to be a reliable method for investigating osseointegrated implants in the temporal bone.
- 16 October 2009
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (2) , 236-240
Sleeping Implant in the Temporal Bone: Report of a Case with 20-Year Follow-Up
Background: There is limited knowledge of the long-term fate of “sleeping” or nonloaded implants in the temporal bone.Purpose: This article describes the fate of a fixture installed in the temporal bone that remained unloaded for 20 years.Patient and Methods: A 25-year-old male with hemifacial microsomia had three osseointegrated implants installed for an auricular episthesis and bone-anchored hearing aid (BAHA) in the left temporal bone in 1988. Two of the implants for the ear episthesis were activated the same year, but the fixture for the hearing aid was not uncovered until 2008. When the patient experienced hearing problems at his office, he wanted to reactivate the sleeping implant. An audiogram showed a maximum conductive hearing loss with good preserved cochlear function. Before reactivation, an Accuitomo three-dimensional, cone beam computed tomography was performed. Resonance frequency analysis (RFA) using the Ostell technique was done when the implant was uncovered.Results: Preoperative x-ray investigation showed the sleeping implant to be well integrated in the temporal bone, covered with 1 mm bone, and with no signs of resorption. Geometric measurements correlating to the two loaded implants showed the sleeping implant to be positioned too close to these to be able to anchor a BAHA without interference with the episthesis. Surgical exploration was done to analyze the implant. The clinical status correlated well to that diagnosed from the x-ray investigation. RFA revealed the implant to be well integrated. A new fixture and abutment for BAHA was installed in the temporal line and activated 2 months after surgery. The patient is today supplied with a BAHA.Conclusion: It seems possible to use sleeping implants in the temporal bone even 20 years after installation.
- 16 October 2009
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (2) , 236-240
Sleeping Implant in the Temporal Bone: Report of a Case with 20-Year Follow-Up
Background: There is limited knowledge of the long-term fate of “sleeping” or nonloaded implants in the temporal bone.Purpose: This article describes the fate of a fixture installed in the temporal bone that remained unloaded for 20 years.Patient and Methods: A 25-year-old male with hemifacial microsomia had three osseointegrated implants installed for an auricular episthesis and bone-anchored hearing aid (BAHA) in the left temporal bone in 1988. Two of the implants for the ear episthesis were activated the same year, but the fixture for the hearing aid was not uncovered until 2008. When the patient experienced hearing problems at his office, he wanted to reactivate the sleeping implant. An audiogram showed a maximum conductive hearing loss with good preserved cochlear function. Before reactivation, an Accuitomo three-dimensional, cone beam computed tomography was performed. Resonance frequency analysis (RFA) using the Ostell technique was done when the implant was uncovered.Results: Preoperative x-ray investigation showed the sleeping implant to be well integrated in the temporal bone, covered with 1 mm bone, and with no signs of resorption. Geometric measurements correlating to the two loaded implants showed the sleeping implant to be positioned too close to these to be able to anchor a BAHA without interference with the episthesis. Surgical exploration was done to analyze the implant. The clinical status correlated well to that diagnosed from the x-ray investigation. RFA revealed the implant to be well integrated. A new fixture and abutment for BAHA was installed in the temporal line and activated 2 months after surgery. The patient is today supplied with a BAHA.Conclusion: It seems possible to use sleeping implants in the temporal bone even 20 years after installation.
- 23 May 2007
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 9 (2) , 94-99
High Age at the Time of Implant Installation is Correlated with Increased Loss of Osseointegrated Implants in the Temporal Bone
Background The implant failure rate in temporal bone has been reported to be about 5 to 10% over a 10‐year period. A number of our elderly patients have shown increased failure rates over a long time period, which is the reason for the present study.Purpose The aim of the present study was to find out if age is correlated with implant failure and to measure blood flow in implant sites.Materials and Methods The long‐time survival of 131 osseointegrated implants installed in the temporal bones of 81 patients was correlated with the age of the patient at the time of installation. The blood flow in 37 fixture installation sites in 22 patients was recorded by means of laser Doppler flowmetry.Results The mean implant failure rate in the study group was 9.8% after a mean follow‐up time of 7.6 years. There was a significant increase of implant failure in patients above 60 years of age. There was further a trend that implants used for the bone‐anchored hearing aid were lost to a higher proportion than implants used for bone‐anchored episthesis. There was also a trend that female patients lost fewer implants than males. Blood flow in the temporal bone correlated well with the age of the patient in that the highest values were recorded from the youngest patients.Conclusions Increasing age affects failures of osseointegrated implants in the temporal bone. Blood flow is higher in the child’s temporal bone, a factor that can be of importance to understand why age influences implant survival.
- 23 May 2007
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 9 (2) , 94-99
High Age at the Time of Implant Installation is Correlated with Increased Loss of Osseointegrated Implants in the Temporal Bone
Background The implant failure rate in temporal bone has been reported to be about 5 to 10% over a 10‐year period. A number of our elderly patients have shown increased failure rates over a long time period, which is the reason for the present study.Purpose The aim of the present study was to find out if age is correlated with implant failure and to measure blood flow in implant sites.Materials and Methods The long‐time survival of 131 osseointegrated implants installed in the temporal bones of 81 patients was correlated with the age of the patient at the time of installation. The blood flow in 37 fixture installation sites in 22 patients was recorded by means of laser Doppler flowmetry.Results The mean implant failure rate in the study group was 9.8% after a mean follow‐up time of 7.6 years. There was a significant increase of implant failure in patients above 60 years of age. There was further a trend that implants used for the bone‐anchored hearing aid were lost to a higher proportion than implants used for bone‐anchored episthesis. There was also a trend that female patients lost fewer implants than males. Blood flow in the temporal bone correlated well with the age of the patient in that the highest values were recorded from the youngest patients.Conclusions Increasing age affects failures of osseointegrated implants in the temporal bone. Blood flow is higher in the child’s temporal bone, a factor that can be of importance to understand why age influences implant survival.
- 18 April 2007
- Published by Wiley in Oral Diseases
- Vol. 13 (3) , 261-269
Craniofacial osseointegration
In year 2007, 30 years have elapsed since the first patient was supplied with a craniofacial osseointegrated implant. The reason for implanting in this patient was a severe conductive hearing loss, which necessitated the use of a bone conduction hearing aid. By utilizing the possibility to transmit sound to the cochlea via direct bone conduction, a new era in audiology was established. Further applications of osseointegration in the craniofacial field is related to the rehabilitation of patients with defects from cancer therapy, malformations, traumatic amputations and burns. Specific fields of osseointegration in this respect are due to possible side effects from radiotherapy and chemotherapy that will affect osseointegration negatively. Other aspects are related to osseointegration in children. This review will focus on the knowledge gained during the first 30 years of craniofacial osseointegration.
- 18 April 2007
- Published by Wiley in Oral Diseases
- Vol. 13 (3) , 261-269
Craniofacial osseointegration
In year 2007, 30 years have elapsed since the first patient was supplied with a craniofacial osseointegrated implant. The reason for implanting in this patient was a severe conductive hearing loss, which necessitated the use of a bone conduction hearing aid. By utilizing the possibility to transmit sound to the cochlea via direct bone conduction, a new era in audiology was established. Further applications of osseointegration in the craniofacial field is related to the rehabilitation of patients with defects from cancer therapy, malformations, traumatic amputations and burns. Specific fields of osseointegration in this respect are due to possible side effects from radiotherapy and chemotherapy that will affect osseointegration negatively. Other aspects are related to osseointegration in children. This review will focus on the knowledge gained during the first 30 years of craniofacial osseointegration.
- 11 January 2007
- Vol. 103 (48) , 3798
["Wait-and-see" in acute otitis media. An effective method for antibiotics use reduction--but a follow up is necessary].
- 11 January 2007
- Vol. 103 (48) , 3798
["Wait-and-see" in acute otitis media. An effective method for antibiotics use reduction--but a follow up is necessary].
- 1 May 2006
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 64 (5) , 812-818
Placement of Dental Implants in Irradiated Bone: The Case for Using Hyperbaric Oxygen
- 1 May 2006
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 64 (5) , 812-818
Placement of Dental Implants in Irradiated Bone: The Case for Using Hyperbaric Oxygen
- 1 May 2005
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 63 (5) , 579-585
Osseointegration in Irradiated Cancer Patients: An Analysis With Respect to Implant Failures
- 1 May 2005
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 63 (5) , 579-585
Osseointegration in Irradiated Cancer Patients: An Analysis With Respect to Implant Failures
- Open Access
- 1 July 2001
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 125 (1) , 85-92
Osseointegrated Implants in Children: Experience from Our First 100 Patients
This study was undertaken on 100 children aged 16 years or under intended for installation of osseointegrated implants. Of these, 76 had implants installed for bone‐anchored hearing aids or prostheses. The main indication for implant installation was a bilateral ear malformation. Surgery was generally performed as a two‐stage procedure with a healing time of 3 to 4 months in between. Available bone thickness was on average 2.5 mm, and lack of bone necessitated bone augmentation in 12 patients. Thirty‐nine percent of implants were installed in contact with the dura, sigmoid sinus, or an air cell. Implant failures were 5.8% of 170 inserted fixtures. Adverse skin reactions appeared in 9.1% of patients over a 21‐year follow‐up period. Revision surgery was undertaken in 22% of patients because of appositional growth of the temporal bone. Of the 24 children considered but not found suitable for osseointegration surgery, plastic surgery was considered a better option, or growth of the temporal bone was awaited. It is concluded that the rate of implant failure is lower in children; the frequency of skin reactions is the same as in adults, but revision surgery is more common in young patients because of new bone formation. Our clinical experience supported by the data presented in this article suggests that the concept could be used with good functional and aesthetic results in children.
- 1 July 2001
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 125 (1) , 85-92
Open AccessOsseointegrated Implants in Children: Experience from Our First 100 Patients
This study was undertaken on 100 children aged 16 years or under intended for installation of osseointegrated implants. Of these, 76 had implants installed for bone‐anchored hearing aids or prostheses. The main indication for implant installation was a bilateral ear malformation. Surgery was generally performed as a two‐stage procedure with a healing time of 3 to 4 months in between. Available bone thickness was on average 2.5 mm, and lack of bone necessitated bone augmentation in 12 patients. Thirty‐nine percent of implants were installed in contact with the dura, sigmoid sinus, or an air cell. Implant failures were 5.8% of 170 inserted fixtures. Adverse skin reactions appeared in 9.1% of patients over a 21‐year follow‐up period. Revision surgery was undertaken in 22% of patients because of appositional growth of the temporal bone. Of the 24 children considered but not found suitable for osseointegration surgery, plastic surgery was considered a better option, or growth of the temporal bone was awaited. It is concluded that the rate of implant failure is lower in children; the frequency of skin reactions is the same as in adults, but revision surgery is more common in young patients because of new bone formation. Our clinical experience supported by the data presented in this article suggests that the concept could be used with good functional and aesthetic results in children.
- Open Access
- 1 July 2000
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 79 (7) , 495-498
Facial Nerve Paralysis following Repair of the External Ear Canal with Ionomeric Cement
A 20-year-old man developed a complete facial nerve paralysis following surgical reconstruction of the posterior ear canal with ionomeric cement. The paralysis developed gradually during the second and third postoperative weeks. Six weeks following the complete removal of the cement, the facial nerve recovered completely. The literature contains reports of diffusion of aluminum ions, which can reach toxic levels in tissue fluid and adjacent bone as the cement hardens. This side effect has been reported to cause an inflammatory response in the dura and brain and has led to fatalities. To our knowledge, there has been no other report of an ionomeric cement having a direct toxic effect on peripheral nerve transmission. Because ionomeric cements are used routinely in otosurgery, especially in canal reconstructions where the proximity to the facial nerve is evident, it is important to use caution when introducing ionomeric cements into near-nerve anatomic locations.
- 1 July 2000
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 79 (7) , 495-498
Open AccessFacial Nerve Paralysis following Repair of the External Ear Canal with Ionomeric Cement
A 20-year-old man developed a complete facial nerve paralysis following surgical reconstruction of the posterior ear canal with ionomeric cement. The paralysis developed gradually during the second and third postoperative weeks. Six weeks following the complete removal of the cement, the facial nerve recovered completely. The literature contains reports of diffusion of aluminum ions, which can reach toxic levels in tissue fluid and adjacent bone as the cement hardens. This side effect has been reported to cause an inflammatory response in the dura and brain and has led to fatalities. To our knowledge, there has been no other report of an ionomeric cement having a direct toxic effect on peripheral nerve transmission. Because ionomeric cements are used routinely in otosurgery, especially in canal reconstructions where the proximity to the facial nerve is evident, it is important to use caution when introducing ionomeric cements into near-nerve anatomic locations.
- 1 January 2000
- Vol. 543
Measurement of bone metal contact (BMC) in retrieved maxillofacial osseointegrated implants.
- 1 January 2000
- Vol. 543
Measurement of bone metal contact (BMC) in retrieved maxillofacial osseointegrated implants.